• Title/Summary/Keyword: Bias detection

Search Result 243, Processing Time 0.029 seconds

Design of a Diode Detector Using Ultra-Wideband Transitions (초광대역 전이 구조를 이용한 다이오드 검파기 설계)

  • Kim, In-Bok;Kim, Young-Gon;Kim, Tae-Gyu;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.814-819
    • /
    • 2008
  • In this paper, a design of broadband detectors utilizing two ultra-wideband transitions is described for the first time, and the implementation method and measurement results of the detectors are provided. Two ultra-wideband transitions are used for input/output matching circuits for the diode detectors. Two detectors have been implemented using general Schottky diodes and zero-bias Schottky diodes. With general Schottky diodes, the fabricated detector provides less than 10 dB return loss from 11 GHz to 20 GHz, and the detector sensitivity is 30 mV/mW. The detector with zero-bias Schottky diodes shows significantly higher detection sensitivity(300 mV/mW).

UDRE Monitoring Analysis of Korean Satellite Navigation System (한국형 위성항법시스템의 UDRE 모니터링 분석)

  • Park, Jong-Geun;Ahn, Jongsun;Heo, Moon-Beom;Joo, Jung Min;Lee, Kihoon;Sung, Sangkyung;Lee, Young Jae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.2
    • /
    • pp.125-132
    • /
    • 2015
  • This paper is about analysis of UDRE monitoring method for Korean Satellite navigation system, which is the correction parameter of satellite measurements. New receiver clock bias and tropospheric delay error estimation method to make pseudo-range residual for UDRE monitoring is proposed. Saastamoinen model and Neill mapping function are used for estimate the tropospheric delay and EKF is used for estimgate the receiver clock bias. Through the satellite measurements and regional weather data received directly from the domestic is using for UDRE monitoring analysis, more suitable UDRE monitoring threshold can be deducted and it is expected to be utilized for fault detection technique of Korean Satellite Navigation System.

Detection and Manipulation of Spin state of Single Molecule Magnet: Kondo resonance and ESR-STM

  • Komeda, T.;Isshiki, H.;Zhang, Y.F.;Katoh, K.;Yoshida, Y.;Yamashita, M.;Miyasaka, H.;Breedlove, B.K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.16-17
    • /
    • 2010
  • Molecular spintronics has attracted attentions, which combines molecular electronics with the spin degree of freedom in electron transport. Among various molecules as candidates of the molecular spintronics, single molecule magnet (SMM) is one of the most promising material. SMM molecules show a ferromagnetic behavior even as a single molecule and hold the spin information even after the magnetic field is turned off. Here in this report, we show the spin behavior of SMM molecules adsorbed on the Au surface by combining the observation of Kondo peak in the STS and ESR-STM measurement. Kondo resonance state is formed near the Fermi level when degenerated spin state interacts with conduction electrons. ESR-STM detects the Larmor frequency of the spin in the presence of a magnet field. The sample include $MPc_2$ and $M_2Pc_3$ molecules ($M\;=\;Tb^{3+}$, $Dy^{3+}$, and $Y^{3+}$ Pc=phthalocyanine) whose critical temperature as a ferromagnet reaches 40 K. A clear Kondo peak was observed which is originated from an unpaired electron in the ligand of the molecule, which is the first demonstration of the Kondo peak originated from electron observed in the STS measurement. We also observed corresponding peaks in ESR-STM spectra. [1] In addition we found that the Kondo peak intensity shows a clear variation with the conformational change of the molecule; namely the azimuthal rotational angle of the Pc planes. This indicates that the Kondo resonance is correlated with the molecule electronic state. We examined this phenomena by using STM manipulation technique, where pulse bias application can rotate the relative azimuthal angle of the Pc planes. The result indicates that an application of ~1V pulse to the bias voltage can rotate the Pc plane and the Kondo peaks shows a clear variation in intensity by the molecule's conformational change.

  • PDF

Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis

  • Chagas, Mariana Murai;Kobayashi-Velasco, Solange;Gimenez, Thais;Cavalcanti, Marcelo Gusmao Paraiso
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.363-372
    • /
    • 2021
  • Purpose: This systematic review and meta-analysis assessed the diagnostic accuracy of imaging examinations for the detection of peri-implant bone defects and compared the diagnostic accuracy between titanium (Ti) and zirconium dioxide (ZrO2) implants. Materials and Methods: Six online databases were searched, and studies were selected based on eligibility criteria. The studies included in the systematic review underwent bias and applicability assessment using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool and a random-effect meta-analysis. Summary receiver operating characteristic (sROC) curves were constructed to compare the effect of methodological differences in relation to the variables of each group. Results: The search strategy yielded 719 articles. Titles and abstracts were read and 61 studies were selected for full-text reading. Among them, 24 studies were included in this systematic review. Most included studies had a low risk of bias (QUADAS-2). Cone-beam computed tomography (CBCT) presented sufficient data for quantitative analysis in ZrO2 and Ti implants. The meta-analysis revealed high levels of inconsistency in the latter group. Regarding sROC curves, the area under the curve (AUC) was larger for the overall Ti group (AUC=0.79) than for the overall ZrO2 group (AUC=0.69), but without a statistically significant difference between them. In Ti implants, the AUCs for dehiscence defects(0.73) and fenestration defects(0.87) showed a statistically significant difference. Conclusion: The diagnostic accuracy of CBCT imaging in the assessment of peri-implant bone defects was similar between Ti and ZrO2 implants, and fenestration was more accurately diagnosed than dehiscence in Ti implants.

A Systematic Review on the Treatment of Post-Stroke Patients Based on Sasang Constitutional Medicine (사상의학적 중풍 후유증 치료에 대한 체계적 문헌 고찰)

  • Oh, Hyunjoo;Lee, Jeongyun;Lee, Hyeri;Lee, Junhee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.34 no.2
    • /
    • pp.48-64
    • /
    • 2022
  • Objectives The purpose of this study was to review and evaluate the clinical evidence of the efficacy and safety of treatment based on Sasang constitutional medicine (SCM) for post-stroke patients by systematic review and meta-analysis. Methods Randomized controlled trials (RCTs), published in 10 electronic databases up to December 2020, were searched. For the included studies, Cochrane's risk of bias assessment was performed to analyze the methodological quality. The strength of evidence was evaluated using the grading of recommendations assessment, development, and evaluation system based on the results of analyses. All review processes were performed by two independent researchers. Results Five RCTs were finally included. All included RCTs were conducted for one month on post-stroke patients in 60-80s, four studies on Tae-Eum patients and one study on So-Yang patients. Four types of constitution-specific herbal medicine (Chungpyesagan-tang, Cheongsimsanyak-tang, Yeoldahanso-tang, and Yangkyuksanhwa-tang) and constitution-specific acupuncture therapy were identified as interventions. More than half of the included studies were evaluated as low quality due to the high-risk of bias in selection, performance, and detection. The combination of constitution-specific herbal medicine, acupuncture, and conventional treatment was more effective in improving the patients' motor impairment, dysphagia, aphasia, and depression than conventional treatment alone. No serious adverse events by SCM treatment were reported. Conclusions SCM treatment may improve the sequelae of post-stroke patients safely in combination with conventional treatment. Since the quality of clinical evidence included in this study was low, higher quality clinical evidence obtained in well-designed clinical studies will be needed.

Diagnostic accuracy of clinical tests to rule out elbow fracture: a systematic review

  • Giorgio Breda;Gianluca De Marco;Pierfranco Cesaraccio;Paolo Pillastrini
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.2
    • /
    • pp.182-190
    • /
    • 2023
  • Elbow traumas represent a relatively common condition in clinical practice. However, there is a lack of evidence regarding the most accurate tests for screening these potentially serious conditions and excluding elbow fractures. The purpose of this investigation was to analyze the literature concerning the diagnostic accuracy of clinical tests for the detection or exclusion of suspected elbow fractures. A systematic review was performed using the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines. Literature databases including PubMed, Cumulative Index to Nursing and Allied Health Literature, Diagnostic Test Accuracy, Cochrane Library, the Web of Science, and ScienceDirect were searched for diagnostic accuracy studies of subjects with suspected traumatic elbow fracture investigating clinical tests compared to imaging reference tests. The risk of bias in each study was assessed independently by two reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 checklist. Twelve studies (4,485 patients) were included. Three different types of index tests were extracted. In adults, these tests were very sensitive, with values up to 98.6% (95% confidence interval [CI], 95.0%-99.8%). The specificity was very variable, ranging from 24.0% (95% CI, 19.0%-30.0%) to 69.4% (95% CI, 57.3%-79.5%). The applicability of these tests was very high, while overall studies showed a medium risk of bias. Elbow full range of motion test, elbow extension test, and elbow extension and point tenderness test appear to be useful in the presence of a negative test to exclude fracture in a majority of cases. The specificity of all tests, however, does not allow us to draw useful conclusions because there was a great variability of results obtained.

Improvement of precipitation forecasting skill of ECMWF data using multi-layer perceptron technique (다층퍼셉트론 기법을 이용한 ECMWF 예측자료의 강수예측 정확도 향상)

  • Lee, Seungsoo;Kim, Gayoung;Yoon, Soonjo;An, Hyunuk
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.7
    • /
    • pp.475-482
    • /
    • 2019
  • Subseasonal-to-Seasonal (S2S) prediction information which have 2 weeks to 2 months lead time are expected to be used through many parts of industry fields, but utilizability is not reached to expectation because of lower predictability than weather forecast and mid- /long-term forecast. In this study, we used multi-layer perceptron (MLP) which is one of machine learning technique that was built for regression training in order to improve predictability of S2S precipitation data at South Korea through post-processing. Hindcast information of ECMWF was used for MLP training and the original data were compared with trained outputs based on dichotomous forecast technique. As a result, Bias score, accuracy, and Critical Success Index (CSI) of trained output were improved on average by 59.7%, 124.3% and 88.5%, respectively. Probability of detection (POD) score was decreased on average by 9.5% and the reason was analyzed that ECMWF's model excessively predicted precipitation days. In this study, we confirmed that predictability of ECMWF's S2S information can be improved by post-processing using MLP even the predictability of original data was low. The results of this study can be used to increase the capability of S2S information in water resource and agricultural fields.

Backpack- and UAV-based Laser Scanning Application for Estimating Overstory and Understory Biomass of Forest Stands (임분 상하층의 바이오매스 조사를 위한 백팩형 라이다와 드론 라이다의 적용성 평가)

  • Heejae Lee;Seunguk Kim;Hyeyeong Choe
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.3
    • /
    • pp.363-373
    • /
    • 2023
  • Forest biomass surveys are regularly conducted to assess and manage forests as carbon sinks. LiDAR (Light Detection and Ranging), a remote sensing technology, has attracted considerable attention, as it allows for objective acquisition of forest structure information with minimal labor. In this study, we propose a method for estimating overstory and understory biomass in forest stands using backpack laser scanning (BPLS) and unmanned aerial vehicle laser scanning (UAV-LS), and assessed its accuracy. For overstory biomass, we analyzed the accuracy of BPLS and UAV-LS in estimating diameter at breast height (DBH) and tree height. For understory biomass, we developed a multiple regression model for estimating understory biomass using the best combination of vertical structure metrics extracted from the BPLS data. The results indicated that BPLS provided accurate estimations of DBH (R2 =0.92), but underestimated tree height (R2 =0.63, bias=-5.56 m), whereas UAV-LS showed strong performance in estimating tree height (R2 =0.91). For understory biomass, metrics representing the mean height of the points and the point density of the fourth layer were selected to develop the model. The cross-validation result of the understory biomass estimation model showed a coefficient of determination of 0.68. The study findings suggest that the proposed overstory and understory biomass survey methods using BPLS and UAV-LS can effectively replace traditional biomass survey methods.

nBn Based InAs/GaSb Type II Superlattice Detectors with an N-type Barrier Doping for the Long Wave Infrared Detection (InAs/GaSb 제2형 응력 초격자 nBn 장적외선 검출소자 설계, 제작 및 특성평가)

  • Kim, Ha Sul;Lee, Hun;Klein, Brianna;Gautam, Nutan;Plis, Elena A.;Myers, Stephen;Krishna, Sanjay
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.6
    • /
    • pp.327-334
    • /
    • 2013
  • Long-wave infrared detectors using the type-II InAs/GaSb strained superlattice (T2SL) material system with the nBn structure were designed and fabricated. The band gap energy of the T2SL material was calculated as a function of the thickness of the InAs and GaSb layers by the Kronig-Penney model. Growth of the barrier material ($Al_{0.2}Ga_{0.8}Sb$) incorporated Te doping to reduce the dark current. The full width at half maximum (FWHM) of the $1^{st}$ satellite superlattice peak from the X-ray diffraction was around 45 arcsec. The cutoff wavelength of the fabricated device was ${\sim}10.2{\mu}m$ (0.12 eV) at 80 K while under an applied bias of -1.4 V. The measured activation energy of the device was ~0.128 eV. The dark current density was shown to be $1.0{\times}10^{-2}A/cm^2$ at 80 K and with a bias -1.5 V. The responsivity was 0.58 A/W at $7.5{\mu}m$ at 80 K and with a bias of -1.5 V.

Improvement of PCR Amplification Bias for Community Structure Analysis of Soil Bacteria by Denaturing Gradient Gel Electrophoresis

  • Ahn, Jae-Hyung;Kim, Min-Cheol;Shin, Hye-Chul;Choi, Min-Kyeong;Yoon, Sang-Seek;Kim, Tae-Sung;Song, Hong-Gyu;Lee, Geon-Hyoung;Ka, Jong-Ok
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.10
    • /
    • pp.1561-1569
    • /
    • 2006
  • Denaturing gradient gel electrophoresis (DGGE) is one of the most frequently used methods for analysis of soil microbial community structure. Unbiased PCR amplification of target DNA templates is crucial for efficient detection of multiple microbial populations mixed in soil. In this study, DGGE profiles were compared using different pairs of primers targeting different hypervariable regions of thirteen representative soil bacteria and clones. The primer set (1070f-1392r) for the E. coli numbering 1,071-1,391 region could not resolve all the 16S rDNA fragments of the representative bacteria and clones, and moreover, yielded spurious bands in DGGE profiles. For the E. coli numbering 353-514 region, various forward primers were designed to investigate the efficiency of PCR amplification. A degenerate forward primer (F357IW) often yielded multiple bands for a certain single 16S rDNA fragment in DGGE analysis, whereas nondegenerate primers (338f, F338T2, F338I2) differentially amplified each of the fragments in the mixture according to the position and the number of primer-template mismatches. A forward primer (F352T) designed to have one internal mismatch commonly with all the thirteen 16S rDNA fragments efficiently produced and separated all the target DNA bands with similar intensities in the DGGE profiles. This primer set F352T-519r consistently yielded the best DGGE banding profiles when tested with various soil samples. Touchdown PCR intensified the uneven amplification, and lowering the annealing temperature had no significant effect on the DGGE profiles. These results showed that PCR amplification bias could be much improved by properly designing primers for use in fingerprinting soil bacterial communities with the DGGE technique.