• Title/Summary/Keyword: Between-Group Analysis

Search Result 11,009, Processing Time 0.039 seconds

The Kinematic Analysis of Kasamatus in Vault (도마종목의 Kasamatsu 기술동작 분석)

  • Lee, Soon-Ho;Back, Jin-Ho;Kim, Young-Sun;Kong, Tae-Ung
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.1-11
    • /
    • 2005
  • The study were to assess technical factors between the high score group and the low score group, from the subjects of 8 male national gymnasts, and to analyze the kinematical characteristic and main technical cause on technique of Kasamatsu movement on Vault. The result of this study is this. In case of horse contact time the high score group was swifter than low score group, and there was significant difference between the high score group and the low score group(<.01). On high score group the time of taking on from horse showed shorter than that of taking off from horse, while of the low score group the time of taking on the horse was similar to that of taking off from horse on the average. And in time of pre-flight the high score group on average the was 0.16sec shorter times than the low score group, and so there was significantly difference between groups(<.05). Also It is a characteristic that the high score group was short in horse contact time and longer in post-flight. In the horizontal distance of post-flight, the high score group was 0.11m longer than the low score group and there was significantly statistic difference between groups(<.05). In the vertical height of the cog in Post-flight's phrase, the high score group was 0.15m higher than the low score group and there was significantly statistic difference between groups(.<01). The horizontal velocity and vertical velocity in the event of taking on and off Beat board and Vault weren't significantly statistic differences between two groups. In the slow-down of average horizontal velocity during keeping contact with the beat board, the high score group was larger than the low score group. And in an increased average vertical velocity during keeping contact with the beat board, the high score group was even larger than the low score group. In the projectile angle of cog in taking off the beat board, 40.2deg., the angle of low score group and 39.5deg., the angle of high score group are nearly alike. In the projectile angle of cog in taking off the beat, the high score group showed 1.6Wt larger on average than the low score group. However the average reaction force on the board and Vault wasn't almost different between two groups, showed 0.3~0.6Wt larger in the high score group.

A Analysis of Isotonic Torque of Shoulder Joint for Overthrow Pitcher of Professional Baseball Player (프로야구 오버드로우 투수의 견관절 등속성 토크에 관한 분석)

  • So, Jae-Moo;Kim, Young-Il;Kim, Hyo-Eun
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.295-306
    • /
    • 2002
  • The purpose of this study was analysis inter relative the ball velocity and isotonic torque of shoulder joint. The subject were twelve overthrow pitcher of professional baseball player. The measurement was used Cybex 6000. The results of this study were as follows : 1. As the siting position of maximal adduction torque of dominant, A group was higher than B group. As the non-dominant, B group was higher than A group for improved angular velocity. There is no significance difference between group. 2. As the siting position of maximal abduction torque of dominant and non-dominant, B group was higher than A group for all measurement. There is no significance difference between group. 3. As the layed position of maximal internal torque of dominant, A group was higher than B group. As the non-dominant was just higher at $180_{\circ}$/sec than B group, B group was higher at $60_{\circ}$/sec and $300_{\circ}$/sec than A group. There is no significance difference between group. 4. As the layed position of maximal external torque of dominant and non-dominant, A group was more higher than B group for all measurement. There is no significance difference between group. 5. As the standing position of maximal internal torque of dominant, A group was just higher at $60_{\circ}$/sec than B group, B group was higher at $180_{\circ}$/sec and $300_{\circ}$/sec than A group. As the non-dominant, B group was higher than A group. There is no significance difference between group. 6. As the standing position of maximal external torque of dominant, A group was higher $60_{\circ}$/sec and $180_{\circ}$/sec than B group. But B group was higher $300_{\circ}$/sec than A group. As the non-dominant, B group was higher than A group. There is no significance difference between group.

A Cepstral Analysis of Breathy Voice with Vocal Fold Paralysis (성대마비로 인한 기식 음성에 대한 Cepstral 분석)

  • Kang, Young-Ae;Seong, Cheol-Jae
    • Phonetics and Speech Sciences
    • /
    • v.4 no.2
    • /
    • pp.89-94
    • /
    • 2012
  • The aim of this study is to investigate the usefulness of the parameter CPP (cepstral peak prominence) and LTAS (long term average spectrum) band energy for an analysis of breathy voice with vocal fold paralysis. Thirty-four female subjects who have vocal paralysis after thyroidectomy participated in this study. According to the perceptual judgements by three speech pathologists and one phonetic scholar, subjects were divided into two groups: breathy voice group (n = 21) and non-breathy voice group (n = 13). Maximum sustained phonation task was measured for acoustic analysis. CPP-related (i.e. mean F0, mean CPP, and mean CPPs) and LTAS-related (i.e. minimum, maximum, and mean) parameters were used. Independent samples t-test was conducted. Regarding CPP, there are significant differences in mean CPP and mean CPPs between groups. The values of mean CPP and CPPs in the non-breathy voice group are higher than those in the breathy voice group. The CPP could be regarded as the useful parameter for breathy voice analysis in the clinic. When it comes to LTAS, energy from 0 to 2 kHz are significantly different between groups. The minimum value of non-breathy group is lower than that of breathy group, whereas the maximum value of non-breathy group is higher. The frequency band below 2 kHz seems to be related to breathy voice.

Analysis on job specification characteristics of dietitians in self - operated vs. contracted employee foodservice (직영 및 위탁 사업체 급식소 영양사 직무 명세 특성 분석)

  • Yang, Il-Seon;Cha, Jin-A
    • Journal of the Korean Dietetic Association
    • /
    • v.3 no.2
    • /
    • pp.141-158
    • /
    • 1997
  • The purpose of this study were to investigate the job analysis questionnaire was mailed to 250 dietitians who are members of The Korean dietetic association practice group in self-operated foodservices(hereafter group A)and 250 dietitians who are employed in contracted foodservice companies(hereafter group B). Completed questionnaires were received from 285 dietitians(121 in self-operated, 164 in contracted) ; a response rate of 57%. Statistical data analysis was completed using the SAS/win packages for descriptive analysis, t-test, $x^2$-test, The results of this study can be summarized as follows. 1. The dietetic training or internship experiences were significantly different between the two sample group(p<.001), but the perceptions of needs for training or internship were not different between and they thought one to six month training would be needed for the job. 2. The question about the time needed in order to perform an expert job was answered significantly differently(p<.001) 3. Group A usually took part in obligatory continuing education and short-term training courses, and group B usually took part in obligatory continuing education and on-the-job trainings, respectively. However both group perceived all three types of educations would be needed for performing the job better. 4. As for the physical demands of the job, a certain degree of accuracy and dexterity for physical tasks and equipment operations was needed for the job. Concerning the mental demands, they answered that their job needs considerable creativity and judgement for planning and performing their tasks was needed. 5. As for responsibilities, group B's responsibilities were heavier than group A’s(p<.001) and need for confidentiality was also greater for group B than for group A(p<.001). 6. As for the supervising role differences, group A rarely received supervision from others and they were given directions only in essential situations, whereas group B was usually supervised when planning and performing their job and tasks, showing significant difference in positions between the two sample groups(p<.001). But each group supervised co-workers and employees in their department. 7. With regard to personal contact, both groups frequently contacted people in their department and other departments at the company and sometimes people outside the company. 8. Concerning the work environment, there were some risks and discomforts in the physical environment and there was no significant difference between the two sample groups.

  • PDF

The Relationship between Consumption Value of Preschooler Clothing, Purchase Satisfaction and Brand Loyalty according to the Moderating Effects of Mother's Preschooler Clothing Involvement (어머니의 유아복 관여도 조절효과에 따른 유아복 소비가치, 구매만족, 브랜드 충성도의 관계연구)

  • Lee, Joo-Yun;Rhee, Young-Ju
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.15 no.3
    • /
    • pp.119-135
    • /
    • 2013
  • The purpose of this study was to investigate the relationship between consumption values of preschooler clothing and purchasing satisfaction, company brand loyalty and involvement of preschooler clothing with the mothers of preschoolers. An online survey was adapted as methodology of this study. The collected 323 questionnaires were collected and statistically analyzed. The nine consumption value of preschooler clothing(vicarious satisfaction value, social value, functional value, convenient value, economic value, coordination value, aesthetic value, distinctive value, and fashionable value) resulted from the analysis of survey. Purchasing satisfaction, company brand loyalty, involvement of preschooler clothing was Uni-dimensional. Statistical analysis was performed with frequency analysis, descriptive statistics, exploratory factor analysis, multi-group analysis, confirmatory factor analysis, bivariate correlation analysis, distribution, structural equation, cluster analysis, independent sample t-test, one-way analysis of variance. The results of this study are as follows. In the consumption value of preschooler clothing influencing on the purchasing satisfaction was evaluated depending on the involvement of preschooler clothing group (high-involvement group, low-involvement group). In the low-involvement group, the most significant consumption value of preschooler clothing are economic value, convenient value, social value in order of importance; though in the high-involvement group, aesthetic value, social value, economic value in order of importance. Also the brand royalty was more affected by the purchasing satisfaction in the high-involvement group than in the low-involvement group. In conclusion, the relations of consumption value of preschooler clothing with purchasing satisfaction, company brand loyalty, involvement of preschooler clothing was established in study. The significances of this study is to provide the market segmentation strategy depending on the characteristics of preschooler clothing consumers and establish the information and direction to increase the company brand royalty and purchasing satisfaction.

  • PDF

Quantitative Analysis of Thyroid Blood Flow and Static Imaging in the Differential Diagnosis of Thyroid Nodules

  • Song, Li-Ping;Zhang, Wen-Hong;Xiang, Yang;Zhao, Na
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6331-6335
    • /
    • 2013
  • Objective:To evaluate the performance of combined quantitative analysis of thyroid blood flow and static imaging data in the differential diagnosis of thyroid nodules. Method: Thyroid blood flow and static imaging were performed in 165 patients with thyroid nodules. Patients were divided into a benign thyroid nodule group (BTN, n=135) and a malignant thyroid nodule group (MTN, n=30) based on the results of post-surgical pathologic examination. Carotid artery thyroid transit times (CTTT), perfusion ratio of thyroid nodule blood/thyroid blood (TNB/TB), and perfusion ratio of thyroid nodule blood/carotid artery blood (TNB/CAB) were measured using thyroid blood flow imaging. The ratios between thyroid nodule and ipsilateral submandibular gland (TN/SG) and thyroid nodule and normal thyroid tissue (TN/T) were measured from thyroid static imaging. The differences between the BTN and MTN groups were compared. Results: 1) CTTT was markedly lower in the MTN group than the BTN group, the difference being statistically significant. 2) TNB/TB and TNB/CAB were both significantly higher in MTN than BTN groups. 3) TN/T was significantly lower in MTN group than BTN group. 4) TN/SG was lower in MTN group than BTN group, but the difference was not statistically significant. 5) Using the combination of CTTT and TN/T, the sensitivity, specificity and accuracy were 93.1%, 95.3% and 94.9% respectively for the diagnosis of MTN. Using the combination of CTTT, TNB/TB and TN/T, the sensitivity, specificity and accuracy changed to 89.7%, 100%, and 98.1% respectively. 6) Correlation analysis demonstrated a significant correlation between TN/T and TNB/TB (r=-0.384, P=0.036) and TNB/CAB (r=-0.466, P=0.009) in the MTN group. Conclusion: The combination of quantitative markers from thyroid blood flow and thyroid static imaging had high specificity and accuracy in differential diagnosis of benign and malignant thyroid nodules, thus providing an important imaging diagnostic approach.

Comparative study of new bone formation capability of zirconia bone graft material in rabbit calvarial

  • Kim, Ik-Jung;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.167-176
    • /
    • 2018
  • PURPOSE. The purpose of this study was to compare the new bone formation capability of zirconia with those of other synthetic bone grafts. MATERIALS AND METHODS. Twelve rabbits were used and four 6-mm diameter transcortical defects were formed on each calvaria. Each defect was filled with Osteon II (Os), Tigran PTG (Ti), and zirconia (Zi) bone grafts. For the control group, the defects were left unfilled. The rabbits were sacrificed at 2, 4, and 8 weeks. Specimens were analyzed through micro computed tomography (CT) and histomorphometric analysis. RESULTS. The Ti and Zi groups showed significant differences in the amount of newly formed bone between 2 and 4 weeks and between 2 and 8 weeks (P<.05). The measurements of total bone using micro CT showed significant differences between the Os and Ti groups and between the Os and Zi groups at 2 and 8 weeks (P<.05). Comparing by week in each group, the Ti group showed a significant difference between 4 and 8 weeks. Histomorphometric analysis also showed significant differences in new bone formation between the control group and the experimental groups at 2, 4, and 8 weeks (P<.05). In the comparison of newly formed bone, significant differences were observed between 2 and 4 weeks and between 2 and 8 weeks (P<.05) in all groups. CONCLUSION. Zirconia bone graft material showed satisfactory results in new bone formation and zirconia could be used as a new synthetic bone graft material.

CEPHALOMETRIC CHARACTERISTICS OF OPEN-BITE CASES WITH DEGENERATIVE JOINT DISEASE(DJD) OF TMJ

  • Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.25 no.6 s.53
    • /
    • pp.665-674
    • /
    • 1995
  • The purpose of this study is to investigate the cephalometric characteristics of the open-bite patients with DJD of TMJ. The DJD open-bite cases were compared with normal samples and Class II open-bite cases with normal TMJ respectively. Twenty three open-bite patients with bilateral DJD of TMJ($13.9\~35.3$ yens old, Group I) were selected from the Department of Orthodontics, SNUDH. Group ll consisted of thirteen Class II open-bite cases($13.2\~27.4$ years old) with no TMD signs/symtoms and good condylar shapes. Group III samples were the forty eight healthy dental students who have Class I molar relationships with no history of orthodontic treatment, good facial balance and no TMD symptoms($20.0\~26.8$ years old). First, sixty measurements in the lateral cephalometric radiographs and analysis of variance(P<0.05, Scheffe) were used to compare these three groups. The seven measurements showed significant difference(p<0.05) between Group I and Group II. After analysis of variance, six of them were used for the discriminant analysis(Wilks' stepwise analysis) and the discrminant function for Group I/Group II was obtained. The results and conclusions were as follows : In most of the measurments, Group I and Group II showed the same skeletal and dental characteristics. But seven of the sixty measurements(FH-PP angle, SNB, FH-ArGo angle, articulare angle, genial angle, upper gonial angle and Ar-Go length) were significantly different(p<0.05) between Group I and Group II. These differences may be explained by the fact that in DJD cases the mandible rotated backward due to the shortening of the ramus following the degenerative destruction of condylar head and its surrounding structures. The resulting discriminant function was : $D={-0.120X}_1+{0.066X}_2+{0.144X}_3-{0.058X}_4+2000,\;where\;X_1=ArGo\;length(mm),\;X_2=SArGo\;angle(degree),\;X_3=FH-PP\;angle(degree),\;X_4=Gonial\;angle(degree)$. Mean of the group centroids was -0.555 and percent of the 'grouped' cases correctly classified was $88.89\%$.

  • PDF

Mechanical Response of Changes in Design of Compression Hip Screws with Biomechanical Analysis (생체 역학적 분석에 의한 Compression Hip Screw의 디자인 요소에 대한 평가)

  • 문수정;이희성;권순영;이성재;안세영;이훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1172-1175
    • /
    • 2004
  • At present, CHS(Compression Hip Screw) is one of the best prosthesis for the intertrochanteric fracture. There is nothing to evaluate the CHS itself with the finite element analysis and mechanical tests. They have same ways of the experimental test of the ASTM standards. The purpose of this study is to evaluate the existing CHS and the new CHS which have transformational design factors with finite element analysis and mechanical tests. The mechanical tests are divided into compression tests and fatigue test for evaluating the failure load, strength and fatigue life. This finite element method is same as the experimental test of the ASTM standards. Under 300N of compression load at the lag screw head. There are less differences between Group (5H, basic type) and Group which has 8 screw holes. However, there are lots of big differences between Group and Group which is reinforced about thickness of the neck range. Moreover, the comparison of Group and Group shows similar tendency of the comparison of Group and Group . The Group is reinforced the neck range from Group. After the experimental tests and the finite element analysis, the most effective design factor of the compression hip screws is the reinforcement of the thickness, even though, there are lots of design factors. Moreover, to unite the lag screw with the plate and to analyze by static analysis, the result of this method can be used with experimental test or instead of it.

  • PDF

Diagnostic performance of dental students in identifying mandibular condyle fractures by panoramic radiography and the usefulness of reference images

  • Cho, Bong-Hae
    • Imaging Science in Dentistry
    • /
    • v.41 no.2
    • /
    • pp.53-57
    • /
    • 2011
  • Purpose : The purpose of this study was to evaluate the diagnostic performance of dental students in detection of mandibular condyle fractures and the effectiveness of reference panoramic images. Materials and Methods : Forty-six undergraduates evaluated 25 panoramic radiographs for condylar fractures and the data were analyzed through receiver operating characteristic (ROC) analysis. After a month, they were divided into two homogeneous groups based on the first results and re-evaluated the images with (group A) or without (group B) reference images. Eight reference images included indications showing either typical condylar fractures or anatomic structures which could be confused with fractures. Paired t-test was used for statistical analysis of the difference between the first and the second evaluations for each group, and student�fs t-test was used between the two groups in the second evaluation. The intra- and inter-observer agreements were evaluated with Kappa statistics. Results : Intra- and inter-observer agreements were substantial (k=0.66) and moderate (k=0.53), respectively. The area under the ROC curve (Az) in the first evaluation was 0.802. In the second evaluation, it was increased to 0.823 for group A and 0.814 for group B. The difference between the first and second evaluations for group A was statistically significant (p<0.05), however there was no statistically significant difference between the two groups in the second evaluation. Conclusion : Providing reference images to less experienced clinicians would be a good way to improve the diagnostic ability in detecting condylar fracture.