• 제목/요약/키워드: Bend loss

검색결과 46건 처리시간 0.027초

동축-원추-방사형 전력분할/합성기의 중심부 높이에 따른 최적설계와 아이솔레이션 특성 향상 (On the Optimization of the Coaxial-Conical-Radial Type Power Divider/Combiner and the Improvement of Isolation Characteristics)

  • 최영규
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1727-1732
    • /
    • 2011
  • In order to realize a high performance(low loss, high isolation) microwave power divider/combiner, we have designed the power combiner/divider precisely in accordance with the different hight of central part. In the case of the high central part of the hight of $h_r$=10.2, a compensating part of the conical line is inserted in the conical conversion transmission line, and in the case of low central part of the hight of $h_r$=5.0, the conical conversion transmission line is remodeled into the 2-stage bend structure. In both case, the reflection characteristics are improved to 30dB over the operating frequency range of 5GHz bandwidth. A resistance is inserted between the peripheral ports so as to try to improve the isolation characteristics of the device. For the 16-divider/combiner, the isolation characteristics are improved to 10dB over the operating frequency range of 5GHz bandwidth.

핵연료 봉다발내 비틀린 혼합날개의 형상최적설계 (Shape Optimization of A Twist Mixing Vane in Nuclear Fuel Assembly)

  • 정상호;김광용
    • 한국유체기계학회 논문집
    • /
    • 제12권4호
    • /
    • pp.7-13
    • /
    • 2009
  • The purposes of present work are to analyze the convective heat transfer with three-dimensional Reynolds-averaged Navier-Stokes analysis, and to optimize shape of the mixing vane using the analysis results. Response surface method is employed as an optimization technique. The objective function is defined as a combination of inverse of heat transfer rate and friction loss. Two bend angles of mixing vane are selected as design variables. Thermal-hydraulic performances have been discussed and optimum shape has been obtained as a function of weighting factor in the objective function. The results show that the optimized geometry improves the heat transfer performance far downstream of the mixing vane.

SEM Observations on the Perithecia of Phyllactinia corylea Causing Powdery Mildew Disease in Mulberry

  • Kumar, Vineet;Dhar, Anil;Gupta, V.P.;Babu, A.M.;Sarkar, A.;Datta, R.K.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제3권1호
    • /
    • pp.63-67
    • /
    • 2001
  • Surface morphology of perithecia of the powdery mildew fungus of mulberry, Phyllactinia corylea is described under scanning electron microscope. The perithecia have penicellate cells on the upper surface and at an average 17 acicular appendages towards the lower surface each emerging from a bulbous base. Many perithecial walls towards the base have shrunken walls. When the perithecia dry out they are pushed above the leaf surface by the acicular append-ages which then bend at the base. The bending of the appendages may be attributed to the shrinkage of lower wall cells due to loss of water.

  • PDF

상악견치 후방견인시 저항원 조절을 위한 MAS(Molar Anchoring Spring)의 초기 응력분포에 관한 광탄성학적 연구 (A PHOTOELASTIC STUDY ON THE INITIAL STRESS DISTRIBUTION OF THE MOLAR ANCHORING SPRING(MAS) DURING RETRACTION OF THE MAXILLARY CANINE)

  • 전윤식
    • 대한치과교정학회지
    • /
    • 제26권4호
    • /
    • pp.341-348
    • /
    • 1996
  • 저자는 마찰견인법으로 상악견치 후방견인시 저항원상실을 최소화하기 위해 근심 경사된 구치를 직립시키는 Molar Uprighting Spring의 작용기전을 응용하고 마찰견인법의 장점을 이용하여 임상적으로 사용이 용이하며 저항원상실이나 견치의 조절되지 못한 경사이동(uncontrolled tipping)등의 부작용을 최소화 할 수 있는 장치인 Molar Anchoring Spring(MAS)을 고안하였다. MAS를 임상에 적용한 결과 비교적 만족스러운 결과를 얻어 이에 장치를 소개하며 MAS의 저항원 조절능력과 견치의 이동양상을 평가하기 위하여 광탄성 모형을 제작한 후 주호선에 diameter 0.009" lumen size 0.030" NiTi closed coil spring만을 장착하여 250gm의 견인력이 발생하도록 한 경우와, 같은 NiTi closed coil spring으로 동일한 견인력 이 발생하도록 하고 .017" X .025" TMA wire로 $60^{\circ}$의 tip-back bend를 부여하여 수직교정력이 60-70gm이 되도록 제작한 MAS를 제1대구치 auxiliary tube에 삽입하고 견치 전방에 걸어준 경우를 비교실험 하여 견치견인시 초기응력분포를 관찰한 결과 다음과 같은 결과를 얻었다. 1. 주호선(main arch wire)에 저항원 조절을 위한 조치없이 견치에 수평견인력만을 가했을 때 구치부에 심한 저항원상실은 물론 견치의 원심이동양상도 조절되지 못한 경사이동(uncontrolled tipping)으로 나타났다. 2. 구치부의 저항원 조절을 위해 사용한 MAS는 견치의 원심이동 초기에 구치부 저항원 조절효과와 견치의 정출없는 조절된 경사이동(controlled tipping)을 유도할 수 있는 장치로 나타났다.

  • PDF

과부하 4방향 합류맨홀에서의 손실계수 산정을 위한 실험 연구 (An experimental study for estimation of head loss coefficients at surcharged four-way combining manholes)

  • 류택희;김정수;윤세의
    • 한국수자원학회논문집
    • /
    • 제49권12호
    • /
    • pp.1015-1025
    • /
    • 2016
  • 일반적으로 도심지 배수시설로 설치되는 맨홀은 중간맨홀, $90^{\circ}$ 접합맨홀, 3방향 합류맨홀 및 4방향 합류맨홀 등 다양한 접합 형태를 가지고 있다. 특히 도시유역의 중․하류부에 주로 설치되는 4방향 합류맨홀에서의 과부하흐름은 에너지 손실을 발생시켜 도심지의 침수피해를 가중시키는 주요 원인이다. 그러므로 과부하 4방향 합류맨홀에서의 흐름특성 분석 및 손실계수의 산정이 필요하다. 본 연구에서는 현황조사 결과를 고려하여 수리실험 장치를 제작하였으며, 맨홀 및 관경은 하수도 시설기준을 준용하여 1/5로 축소 제작하였다. 선정된 실험조건인 맨홀 형상 조건(사각형, 원형), 유출유량($Q_{out}$)에 대한 측면유입유량($Q_{lat}$)의 비($Q_{lat}/Q_{out}$) 및 실험 유량(2.0, 3.0, 4.0, $4.8{\ell}/sec$)을 변화시키면서 실험을 실시하였다. 실험결과 측면유량비가 증가할수록 손실계수는 증가하였으며, 사각형 맨홀보다 원형 맨홀에서의 손실계수가 다소 낮게 산정되었다. 그러나 유출유량 변화에 따른 손실계수의 변화는 미미하였다. 측면유량비에 따른 과부하 4방향 합류맨홀의 손실계수는 0.4~0.8로 산정되었다. 또한, 측면유량비 변화를 고려한 4방향 합류맨홀에서의 손실계수 산정식을 제시하였다.

Glass ionomer cement 표면의 산부식 효과에 관한 연구 (THE EFFECT OF ACID ETCHING ON GLASS IONOMER CEMENT SURFACES)

  • 한승원;박상진;민병순;최호영;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.1-26
    • /
    • 1993
  • The purpose of this study was to investigate the effect of acid etching on the surface appearance and fracture toughness of five glass ionomer cements. Five kinds of commercially available glass ionomer cements including chemical curing filling type, chemical curing lining type, chemical curing metal reinforced type, light curing tilling type and light curing lining type were used for this study. The specimens for SEM study were fabricated by treating each glass ionomer cement with either visible light curing or self curing after being inserted into a rubber mold (diameter 4mm, depth 1mm). Some of the specimens were etched with 37% phosphoric acid for 0, 15, 30, 60, go seconds, at 5 minutes, 1 hour and 1 day after mixing of powder and liquid. Unetched ones comprised the control group and the others were the experimental groups. The surface texture was examined by using scanning electron microscope at 20 kV. (S-2300, Hitachi Co., Japan). The specimens for fracture toughness were fabricated by curing of each glass ionomer cement previously inserted into a metal mold for the single edge notch specimen according to the ASTME399. They were subjected to a three-point bend test after etching for 0, 30, 60, and 90 seconds at 5 minutes-, 1 hour-and 1 day-lapse after the fabrication of the specimens. The plane strain fracture toughness ($K_{IC}$) was determined by three-point bend test which was conducted with cross-head speed of 0.5 mm/min using Instron universal testing machine (Model No. 1122) following seven days storage of the etched specimens under $37^{\circ}C$, 100% humidity condition. Following conclusions were drawn. 1. In unetched control group, crack was present, but the surface was generally smooth. 2. Deterioration of the surface appearance such as serious dissolving of gel matrix and loss of glass particles occured as the etching time was increased beyond 15 s following Immediate etching of chemical curing type of glass ionomer cements. 3. Etching after 1 h, and 1 d reduced surface damage, 15 s, and 30s etch gave rough surface appearance without loss of glass particle of chemical curing type of glass ionomer cements. 4. Light curing type glass ionomer cement was etched by acid, but there was no difference in surface appearances according to various waiting periods. 5. It was found that the value of plane stram fracture toughness of glass ionomer cements was highest in the light curing filling type as $1.79\;MNm^{-1.5}$ followed by the light curing lining type, chemical curing metal reinforced type, chemical curing filling type and chemical curing lining type. 6. The value of plane stram fracture toughness of the chemical curing lining type glass ionomer cement etched after 5 minutes was lower than those of the cement etched after 1 hour or day or unetched (P < 0.05). 7. Light curing glass ionomer cement showed Irregular fractured surface and chemical curing cement showed smooth fractured surface.

  • PDF

이악물기 치아접촉시 편측 구치 상실을 지닌 두개골의 부하분석 (Analysis of functional load on the dentated skull with unilateral molar loss during simulated bilateral clenching clenching)

  • 정석조;정승미;강동완
    • 구강회복응용과학지
    • /
    • 제17권4호
    • /
    • pp.245-256
    • /
    • 2001
  • The purpose of this study is to analyze the mechanical stress and displacement on the jaws during the simulated bilateral clenching task on the three-dimensional finite element model of the dentated skull with unilateral molar loss. For this study, the computed tomography(G.E.8800 Quick, USA) was used to scan the total length of human skull in the frontal plane at 2.0mm intervals. The fully assembled finite element model consists of the articular disc, maxilla, mandible, teeth, periodontal ligament and cranium. The FE model was used to simulate the bilateral clenching in intercuspal position. The loading condition was the force of the masseter muscle exerted on the mandible as reported by Korioth et al. degrees of freedom of the zygomatic region where the masseter muscle is attached were fixed as restraints. In order to reflect the actual action of the muscles force, the displacement of the region was attached where the muscle is connected to the temporal bone and restraint conditions were given values identical to values at the attachment region of the masticatory muscle but with the opposite direction of the reaction from when the muscle force is acted on the mandible. Although the mandible generally has higher displacement and von Mises stress than the maxilla, its mandibular corpus on the molar-loss side has a higher stress and displacement than the molar-presence side. Because the displacement and von Mises Stress was the highest on the lateral surface of mandibular corpus with molar loss, the stress level of the condyle on the molar-loss side is greater than that of the molar-presence side, which in turn caused the symphysis of the mandible to bend. In conclusion, the unilateral posterior bite collapse with molar loss under para-functional activities such as bruxism and clenching can affect the stress concentration on the condyle and mandibular corpus. It is therefore necessary to consider the biomechanical function of dento-skeleton under masticatory force while designing the occlusal scheme of restoration on alveolar bone with the posterior collapse.

  • PDF

운전자 졸음 방지용 플라스틱 광섬유 센서 (Plastic Optical Fiber Sensor for an Anti-Drowsy Driving)

  • 엄원대;여상두;박재희
    • 한국ITS학회 논문지
    • /
    • 제7권6호
    • /
    • pp.133-139
    • /
    • 2008
  • 본 논문에서는 플라스틱 광섬유 센서가 운전자의 졸음 방지용 센서로서 응용 가능한 지에 관하여 논의된다. 졸음방지용 플라스틱 광섬유 센서는 광섬유의 구부림이 잘 유도될 수 있도록 소프트한 물질로 덮개를 씌운 핸들에 플라스틱 광섬유가 감겨져 여는 구조로 되어져 있다. 운전자가 핸들을 잡을 때 운전자가 핸들에 힘을 가하게 되고 이 힘이 플라스틱 광섬유의 구부림을 유도하여 플라스틱 광섬유 내부를 진행하는 빛의 양을 감소시킨다. 실험 결과로부터 핸들에 가해지는 힘이 크면 클수록 검출되는 광량이 적어짐을 보여주어 졸음 방지용 센서로서의 사용할 수 있음을 검증해 보인다.

  • PDF

An Experimental Study of Reinforced Concrete Beams with Closely-Spaced Headed Bars

  • Lam, Kah Mun;Kim, Woo-Suk;Van Zandt, Michael;Kang, Thomas H.K.
    • International Journal of Concrete Structures and Materials
    • /
    • 제5권2호
    • /
    • pp.77-85
    • /
    • 2011
  • The use of headed bars as opposed to standard 90- or 180-degree hooked bars in beam ends, beam-column joints or other steel congested areas for anchorage and bond has become more favorable due to the fact that steel congestion is often created by large bend diameters or crossties. This research mainly focuses on evaluating the code provisions regarding the use of headed bars. Nine simply supported rectangular concrete beams with headed longitudinal reinforcement were tested under a four-point monotonic loading system. The design clear spacing, which varies from 1.5 to 4.25 times the bar diameter, was the only parameter for the experimental investigation. The test results showed that the closely-spaced headed bars were capable of developing to full yield strength without any severe brittle concrete breakout cone or pullout failure. Bond along the bar was not sufficient due to the early loss of concrete integrity. However, the headed bars were effective for anchorage with no excessive moment capacity reduction. This implies that the clear spacing of about 2 times the bar diameter for headed bars may be reasonable to ensure the development of specified yield strength of headed bars and corresponding member design strength.

Stress Analysis Using Finite Element Modeling of a Novel RF Microelectromechanical System Shunt Switch Designed on Quartz Substrate for Low-voltage Applications

  • Singh, Tejinder;Khaira, Navjot K.;Sengar, Jitendra S.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권5호
    • /
    • pp.225-230
    • /
    • 2013
  • This paper presents a novel shunt radio frequency microelectromechanical system switch on a quartz substrate with stiff ribs around the membrane. The buckling effects in the switch membrane and stiction problem are the primary concerns with RF MEMS switches. These effects can be reduced by the proposed design approach due to the stiffness of the ribs around the membrane. A lower mass of the beam and a reduction in the squeeze film damping is achieved due to the slots and holes in the membrane, which further aid in attaining high switching speeds. The proposed switch is optimized to operate in the k-band, which results in a high isolation of -40 dB and low insertion loss of -0.047 dB at 21 GHz, with a low actuation voltage of only 14.6 V needed for the operation the switch. The membrane does not bend with this membrane design approach. Finite element modeling is used to analyze the stress and pull-in voltage.