DOI QR코드

DOI QR Code

An Experimental Study of Reinforced Concrete Beams with Closely-Spaced Headed Bars

  • Lam, Kah Mun (School of Civil Engineering and Environmental Science, University of Oklahoma) ;
  • Kim, Woo-Suk (KCI Member, School of Architecture and Civil Engineering, Kyungpook National University) ;
  • Van Zandt, Michael (School of Civil Engineering and Environmental Science, University of Oklahoma) ;
  • Kang, Thomas H.K. (KCI Member, Dept. of Architecture and Architectural Engineering, Seoul National University)
  • 투고 : 2011.01.31
  • 심사 : 2011.10.07
  • 발행 : 2011.12.30

초록

The use of headed bars as opposed to standard 90- or 180-degree hooked bars in beam ends, beam-column joints or other steel congested areas for anchorage and bond has become more favorable due to the fact that steel congestion is often created by large bend diameters or crossties. This research mainly focuses on evaluating the code provisions regarding the use of headed bars. Nine simply supported rectangular concrete beams with headed longitudinal reinforcement were tested under a four-point monotonic loading system. The design clear spacing, which varies from 1.5 to 4.25 times the bar diameter, was the only parameter for the experimental investigation. The test results showed that the closely-spaced headed bars were capable of developing to full yield strength without any severe brittle concrete breakout cone or pullout failure. Bond along the bar was not sufficient due to the early loss of concrete integrity. However, the headed bars were effective for anchorage with no excessive moment capacity reduction. This implies that the clear spacing of about 2 times the bar diameter for headed bars may be reasonable to ensure the development of specified yield strength of headed bars and corresponding member design strength.

키워드

참고문헌

  1. ACI Committee 318, "Building Code Requirements for Reinforced Concrete (ACI 318-71)," American Concrete Institute, Detroit, MI, 1971, 78 pp.
  2. ACI Committee 318, "Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary," American Concrete Institute, Farmington Hills, MI, 2008, 473 pp.
  3. ASTM A970/A 970M-04a, "Standard Specification for Headed Steel Bars for Concrete Reinforcement," ASTM International, West Conshohocken, PA, 2004, 8 pp.
  4. Joint ACI-ASCE Committee 352, "Recommendations for Design of Beam-Column Connections in Monolithic Reinforced Concrete Structures (ACI 352R-02)," American Concrete Institute, Farmington Hills, MI, 2002, 37 pp.
  5. DeVries, R. A., Jirsa, J. O. and Bashandy, T., "Effects of Transverse Reinforcement and Bonded Length on the Side-Blowout Capacity of Headed Reinforcement," ACI Structural Journal Special Publication, Vol. 180, Oct. 1998, pp. 367-389.
  6. Ferguson, P. M., Breen, J. E., and Jirsa, J. O., Reinforced Concrete Fundamentals, 5th Edition, John Wiley & Sons, Inc., New York, N.Y., 1988, 746 pp.
  7. Hong, S.-G., Chun, S.-C., Lee, S.-H., and Oh, B., "Strutand-Tie Model for Development of Headed Bars in Exterior Beam-Column Joint," ACI Structural Journal, Vol. 104, No. 5, Sept.-Oct. 2007, pp. 590-600.
  8. Kang, T. H.-K., Ha, S.-S., and Choi, D.-U., "Bar Pullout Tests and Seismic Tests of Small-Headed Bars in Beam-Column Joints," ACI Structural Journal, Vol. 107, No. 1, Jan.-Feb. 2010, pp. 32-42.
  9. Mains, R. M., "Measurement of the Distribution of Tensile and Bond Stresses along Reinforcing Bars," ACI Structural Journal, Vol. 48, No. 11, Nov. 1951, pp. 225-252.
  10. Minor, J. and Jirsa, J. O., "Behavior of Bent Bar Anchorages," ACI Structural Journal, Vol. 72, No. 4, April 1975, pp. 141-149.

피인용 문헌

  1. Seismic behavior evaluation of exterior beam-column joints with headed or hooked bars using nonlinear finite element analysis vol.7, pp.5, 2014, https://doi.org/10.12989/eas.2014.7.5.861