• 제목/요약/키워드: Beam-Column Joints

검색결과 411건 처리시간 0.02초

철근콘크리트 보-기둥 접합부의 전단강도 평가 (Shear Strength Estimate of Reinforced Concrete Beam-Column Joints)

  • 채희대;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.389-392
    • /
    • 2004
  • An accurate and rational analytical proposal for determining the shear strengths of interior beam-column joints is presented in this paper. The proposed equation is derived using a compatiblity aided truss model theory. The accuracy of the proposed equation was checked by comparing calculated shear strength of joints with experimental results reported papers in literature. The comparison showed that the proposed equation predicted the experimental shear strength of joints with reasonable agreement.

  • PDF

Interaction of internal forces of exterior beam-column joints of reinforced concrete frames under seismic action

  • Zhou, Hua;Zhang, Zhisheng
    • Structural Engineering and Mechanics
    • /
    • 제44권2호
    • /
    • pp.197-217
    • /
    • 2012
  • Detailed analysis of internal forces of exterior beam-column joints of RC frames under seismic action is reported in this paper. A formula is derived for calculating the average joint shear from the column shears, and a formula is proposed to estimate torque in eccentric joints induced by seismic action. Average joint shear stress and strain are defined consistently for exterior joints, which can be used to establish joint shear constitutive relationship. Numerical results of shear, bending moment and torque in joints induced by seismic action are presented for a pair of concentric and eccentric exterior connections extracted from a seismically designed RC frame, and two sections located at the levels of beam bottom and top reinforcement, respectively, are identified as the critical joint sections for evaluating seismic joint behavior. A simplified analysis of the effects of joint shear and torque on the flexural strengths of the critical joint sections is made for the two connections extracted from the frame, and the results indicate that joint shear and torque induced by a strong earthquake may lead to "joint-hinging" mechanism of seismically designed RC frames.

관통형 연결재로 연결된 PC 보-기둥 맞댐 접합의 내진성능에 관한 실험적 연구 (Seismic Performance of Precast Beam-Column Joints with Thru-Connectors)

  • 박순규;김민희
    • 콘크리트학회논문집
    • /
    • 제22권4호
    • /
    • pp.441-450
    • /
    • 2010
  • 건식공법이 가능하도록 기존의 접합 방식과 차별화 되는 PC 보-기둥 접합부를 개발하여 실용화하기 위한 기초 연구이다. 연속된 PC 기둥 양편에 위치한 보의 접합 단부를 고강도 관통형 연결재로 긴장하여 연결하는 'PC 보-기둥 맞댐 접합(BCJ_TB : precast beam column joints connected with thru-connects)'을 고안하고 실험적 연구를 수행하여 강도저하, 초기강성, 강성저하, 에너지소산능력 등의 내진성능을 분석하였다. 실험 결과에 기둥에서는 손상이 발생하지 않고 보 단부에서 압축파괴가 발생하는데, 이는 비부착 연결재의 초기긴장과 비부착 효과에 의하여 보 단부 콘크리트에 압축응력이 증가하기 때문인 것으로 분석되었다. 보 접합 단부에 CFRP로 구속 효과를 준 접합부의 성능이 상대적으로 우수하였고 네오프렌 패드로 보 기둥 접합면을 연결한 것이 다른 것에 비하여 초기강성을 제외하고는 우수한 내진성능을 보이는 것으로 분석되었다. 비부착 연결재를 사용한 접합부의 파괴모드를 개선하기 위하여 보 단부 콘크리트의 압축 성능을 향상시키고, 연결재의 변위를 적절히 조절할 수 있는 방법이 요구된다.

고강도 철근 및 고강도 콘크리트를 사용한 보-기둥 접합부의 연성거동 (Ductile Behavior of High Strength Reinforced Concrete Beam-Column Joint)

  • 이정한;유영찬;이원호;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.537-540
    • /
    • 1999
  • The primary objective of this study is to make a contribution to the construction of 40~60 story R/C high rise building by developing the reinforcing details which can improve the seismic performance of high-strength (f'c=700kg/$\textrm{cm}^2$, fy=4000, 8000kg/$\textrm{cm}^2$) R/C beam-column joints. And the purpose of this study is to investigate experimentally the effect of load history on the total energy dissipation capacity of reinforced concrete flexural members. The reinforcing details which can make beam plastic hinging zones moved and spreaded from the column face is proposed to insure the ductile behavior of high-strength RC beam-column joints. The intermediate reinforcement which is horizontally anchored by interlinking each intermediate reinforcements is proposed and tested to examine the mechanical performance of proposed details. Main variables are the shape of the intermediate reinforcements and yield strength of rebars. From the test results, the newly proposed intermediate reinforcement details can move and spread the beam plastic hinging zone about 1.0d from the column face.

  • PDF

고강도 철근 및 고강도 콘크리트를 사용한 보-기둥 접합의 비선형 거동 (Inelastic Behavior of High Strength Reinforced Concrete Beam-Column Joint)

  • 이정한;조중현;유영찬;이원호;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.547-552
    • /
    • 1999
  • The purpose of this study is to make a contribution to the construction of 40∼60 story R/C high rise building by developing the reinforcing details which can improve the seismic performance of high-strength (f'c=700㎏/㎠, fy=4000, 8000㎏/㎠) R/C beam-column joints. The reinforcing details which can make beam plastic hinging zones moved and spreaded from the column face is proposed to insure the ductile behavior of high-strength RC beam-column joints. The intermediate reinforcement which is vertically anchored by interlinking each intermediate reinforcements is proposed and tested to examine the mechanical performance of proposed details. Main variables are the shape of the intermediate reinforcements and yield strength of rebars. From the test results, the newly proposed intermediate reinforcement details can move and spread the beam plastic hinging zone about 1.0d from the column face.

  • PDF

Influence of exterior joint effect on the inter-story pounding interaction of structures

  • Favvata, Maria J.;Karayannis, Chris G.;Liolios, Asterios A.
    • Structural Engineering and Mechanics
    • /
    • 제33권2호
    • /
    • pp.113-136
    • /
    • 2009
  • The seismic induced interaction between multistory structures with unequal story heights (inter-story pounding) is studied taking into account the local response of the exterior beam-column joints. Although several parameters that influence the structural pounding have been studied sofar, the role of the joints local inelastic behaviour has not been yet investigated in the literature as key parameter for the pounding problem. Moreover, the influence of the infill panels as an additional parameter for the local damage effect of the joints on the inter-story pounding phenomenon is examined. Thirty six interaction cases between a multistory frame structure and an adjacent shorter and stiffer structure are studied for two different seismic excitations. The results are focused: (a) on the local response of the critical external column of the multistory structure that suffers the hit from the slab of the adjacent shorter structure, and (b) on the local response of the exterior beam-column joints of the multistory structure. Results of this investigation demonstrate that the possible local inelastic response of the exterior joints may be in some cases beneficial for the seismic behaviour of the critical column that suffers the impact. However, in all the examined cases the developing demands for deformation of the exterior joints are substantially increased and severe damages can be observed due to the pounding effect. The presence of the masonry infill panels has also been proved as an important parameter for the response of the exterior beam-column joints and thus for the safety of the building. Nevertheless, in all the examined inter-story pounding cases the presence of the infills was not enough for the total amelioration of the excessive demands for shear and ductility of the column that suffers the impact.

Reliability based calibration of the capacity design rule of reinforced concrete beam-column joints

  • Thomos, George C.;Trezos, Constantin G.
    • Computers and Concrete
    • /
    • 제8권6호
    • /
    • pp.631-645
    • /
    • 2011
  • The capacity design rule for beam-column joints, as adopted by the EC8, forces the formation of the plastic hinges to be developed in beams rather than in columns. This is achieved by deriving the design moments of the columns of a joint from equilibrium conditions, assuming that plastic hinges with their possible overstrengths have been developed in the adjacent beams of the joint. In this equilibrium the parameters (dimensions, material properties, axial forces etc) are, in general, random variables. Hence, the capacity design is associated with a probability of non-compliance (probability of failure). In the present study the probability of non-compliance of the capacity design rule of joints is being calculated by assuming the basic variables as random variables. Parameters affecting this probability are examined and a modification of the capacity design rule for beam-column joints is proposed, in order to achieve uniformity of the safety level.

Experimental behaviour of extended end-plate composite beam-to-column joints subjected to reversal of loading

  • Hu, Xiamin;Zheng, Desheng;Yang, Li
    • Structural Engineering and Mechanics
    • /
    • 제24권3호
    • /
    • pp.307-321
    • /
    • 2006
  • This paper is concerned with the behaviour of steel and concrete composite joints subjected to reversal of loading. Three cruciform composite joint specimens and one bare steel joint specimen were tested so that one side of the beam-to-column connection was under negative moment and another side under positive moment. The steelwork beam-to-column connections were made of bolted end plate with an extended haunch section. Composite slabs employing metal decking were used for all the composite joint specimens. The moment-rotation relationships for the joints were obtained experimentally. Details of the experimental observations and results were reported.

철근콘크리트 보-기둥 접합부의 비선형 전단거동예측 (Prediction of Nonlinear Shear Behavior of Reinforced Concrete Beam-Column Joints)

  • 조창근;우성우
    • 한국지진공학회논문집
    • /
    • 제13권2호
    • /
    • pp.29-36
    • /
    • 2009
  • 본 연구는 철근콘크리트 내부 보-기둥 접합부의 전단거동 예측에 관한 비선형 모델을 제안한 것이다. 보-기둥 접합부 패널존에서의 전단거동 모델을 위하여 면내전단 예측을 위한 연화트러스모델 이론을 수정한 이론을 적용하였다. 이로부터 접합부에서의 평형조건에 의한 등가 모멘트 및 회전 관계를 이용하여 접합부에서의 전단변형 관계를 접합부의 회전스프링의 특성관계로 변환하여 고려토록 하였다. 소개된 해석모델을 축력 및 전단을 받는 내부 철근콘크리트 보-기둥 접합부의 실험과 비교하였으며, 제시된 모델은 접합부에서의 전단력 뿐만 아니라 전단변형의 예측에도 유효한 것으로 판단되었다.

철근콘크리트 보-기둥 접합부의 내진성능 개선 보강 신기술 (New Technique on the Improvement of Earthquake-Resistant Performance for the Retrofitting of Existing Reinforced Concrete Beam-Column Joints)

  • 하기주
    • 한국지진공학회논문집
    • /
    • 제8권2호
    • /
    • pp.73-81
    • /
    • 2004
  • 본 연구에서는 기존 철근콘크리트건물 보-기둥 접합부의 내진 성능을 개선하기 위하여 탄소섬유를 사용하여 구조물을 보강한 후 실험을 수행하였다. 이를 위하여 6개의 철근콘크리트 보-기둥 접합부를 제작하였으며, 지진하중과 같은 반복하중이 작용할 때 보강재료 및 보강영역 등을 변수로 하여 실험을 수행하여 각 보강변수에 따른 보강효과를 평가하였다. 본 실험을 통하여 구조물의 내진 성능 및 연성능력을 증진시킬 목적으로 새로운 보강재료(탄소섬유판, 탄소섬유봉, 탄소섬유쉬트)로 설계된 보강 실험체(RPC-CP2, RPC-CR, RJC-CP, RJC-CR)들은 내력증진은 물론이고 안정적인 이력거동을 확보할 수 있었다.