• Title/Summary/Keyword: Beam Radiation

Search Result 1,746, Processing Time 0.031 seconds

Comparing the dosimetric impact of fiducial marker according to density override method : Planning study (양성자 치료계획에서 fiducial marker의 density override 방법에 따른 선량변화 비교 : Planning study)

  • Sung, Doo Young;Park, Seyjoon;Park, Ji Hyun;Park, Yong Chul;Park, Hee Chul;Choi, Byoung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.19-26
    • /
    • 2017
  • Purpose: The application of density override is very important to minimize dose calculation errors by fiducial markers of metal material in proton treatment plan. However, density override with actual material of the fiducial marker could make problem such as inaccurate target contouring and compensator fabrication. Therefore, we perform density override with surrounding material instead of actual material and we intend to evaluate the usefulness of density override with surrounding material of the fiducial marker by analyzing the dose distribution according to the position, material of the fiducial marker and number of beams. Materials and Method: We supposed that the fiducial marker of gold, steel, titanium is located in 1.5, 2.5, 4.0, 6.0 cm from the proton beam's end of range using water phantom. Treatment plans were created by applying density override with the surrounding material and actual material of the fiducial marker. Also, a liver cancer patient who received proton therapy was selected. We located the fiducial marker of gold, steel, titanium in 0, 1.5, 3.5 cm from the proton beam's end of range and the treatment plans were created by same method with water phantom. Homogeneity Index(HI), Conformity Index(CI) and maximum dose of Organ At Risk(OAR) in Planning Target Volume(PTV) as the evaluation index were compared according to the material, position of the fiducial marker and number of beam. Results: The HI value was more decreased when density override with surrounding material of the fiducial marker was performed comparing with density override with actual material. Especially the HI value was increased when the fiducial marker was located farther from the proton beam's end of the range for a single beam and the fiducial marker's position was closer to isocenter for two or more beams. The CI value was close to 1 and OAR maximum dose was greatly reduced when density override with surrounding material of the fiducial marker was performed comparing with density override with actual material. Conclusion: Density override with surrounding material can be expected to achieve more precise proton therapy than density override with actual material of the fiducial marker and could increase the dose uniformity and target coverage and reduce the dose to surrounding normal tissues for the small fiducial markers used in clinical practice. Most of all, it is desirable to plan the treatment by avoiding the fiducial marker of metal material as much as possible. However, if the fiducial marker have on the beam path, density override of the surrounding material can be expected to achieve more precise proton therapy.

  • PDF

Consideration of the Effect according to Variation of Material and Respiration in Cone-Beam CT (Cone-Beam CT에서 물질 및 호흡 변화가 영상에 미치는 영향에 대한 고찰)

  • Na, Jun-Young;Kim, Jung-Mi;Kim, Dae-Sup;Kang, Tae-Young;Baek, Geum-Mun;Kwon, Gyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.15-21
    • /
    • 2012
  • Purpose: Image Guided Radiation Therapy (IGRT) has been carried out using On-Board Imager system (OBI) in Asan Medical Center. For this reason, This study was to analyze and evaluate the impact on Cone-Beam CT according to variation of material and respiration. Materials and Methods: This study was to acquire and analyze Cone-Beam CT three times for two material: Cylider acryl (lung equvalent material, diameter 3 cm), Fiducial Marker (using clinic) under Motion Phantom able to adjust respiration pattern randomly was varying period, amplitude and baseline vis-a-vis reference respiration pattern. Results: First, According to a kind of material, when being showed 100% in the acryl and 120% in the Fiducial Marker under the condition of same movement of the motion phantom. Second, According to the respiratory alteration, when being showed 1.13 in the baseline shift 1.8 mm and 1.27 in the baseline shift 3.3 mm for acryl. when being showed 1.01 in 1 sec of period and 1.045 in 2.5 sec of period for acryl. When being showed 0.86 in 0.7 times the standard of amplitude and 1.43 in 1.7 times the standard of amplitude for acryl. when being showed 1.18 in the baseline shift 1.8 mm and 1.34 in the baseline shift 3.3 mm for Fiducial Marker. when being showed 1.0 in 1 sec of period and 1.0 in 2.5 sec of period for Fiducial Marker. When being showed 0.99 in 0.7 times the standard of amplitude and 1.66 in 1.7 times the standard of amplitude for Fiducial Marker. Conclusion: The effect of image size of CBCT was 20% in the case of Fiducial marker. The impact of changes in breathing pattern was minimum 13% - maximum 43% for Arcyl, min. 18% - max. 66% for Fiducial marker. This difference makes serious uncertainty. So, Must be stabilized breathing of patient before acquiring CBCT. also must be monitored breathing of patient in the middle of acquire. If you observe considerable change of breathing when acquiring CBCT. After Image Guided, must be need to check treatment site using fluoroscopy. If a change is too big, re-acquiring CBCT.

  • PDF

Fluoroscopic Radiation Exposure during Percutaneous Kyphoplasty

  • Choi, Hyun-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.1
    • /
    • pp.37-42
    • /
    • 2011
  • Objective: The author measured levels of fluoroscopic radiation exposure to the surgeon's body based on the different beam directions during kyphoplasty. Methods: This is an observational study. A series of 84 patients (96 vertebral bodies) were treated with kyphoplasty over one year. The patients were divided into four groups based on the horizontal and vertical directions of the X-Ray beams. We measured radiation exposure with the seven dosimetry badges which were worn by the surgeon in each group (total of 28 badges). Twenty-four procedures were measured in each group. Cumulative dose and dose rates were compared between groups. Results: Fluoroscopic radiation is received by the operator in real-time for approximately 50% (half) of the operation time. Thyroid protectors and lead aprons can block radiation almost completely. The largest dose was received in the chest irrespective of beam directions. The lowest level of radiation were received when X-ray tube was away from the surgeon and beneath the bed (dose rate of head, neck, chest, abdomen and knee: 0.2986, 0.2828, 0.9711, 0.8977, 0.8168 mSv, respectively). The radiation differences between each group were approximately 2.7-10 folds. Conclusion: When fluoroscopic guided-KP is performed, the X-Ray tube should be positioned on the opposite side of the operator and below the table, otherwise the received radiation to the surgeon's body would be 2.7-10 times higher than such condition.

Effects of radiation on wall-friction and heat-transfer in a convergent- divergent nozzle (복사가 수축 확대 노즐의 벽면에서 열전달과 벽마찰에 미치는 효과)

  • 강신형;이준식;김성훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1639-1644
    • /
    • 1990
  • Effects of radiation on the wall-friction and heat transfer in the convergent and divergent nozzle of a rocket motor are investigated in the present paper. Radiative heat transfer cools down the core gas, and the decrease in the gas temperature reduces the convective heat transfer on the wall. Radiation heat transfer is estimated by using mean-beam-length approach and core flow is assumed to be one-dimensional isentropic. The compressible thermal boundary layer is solved by a finite difference method. The Cebeci-Smith eddy viscosity model is adopted for the present study. Convective heat transfer is reduced at the throat of the nozzle and is almost compensated with an increase in radiative transfer. In the sequel total heat transfer rate is slightly reduced. However, radiation heat transfer is dominant in the converging part of the nozzle.

Modeling of Radiation Beams from Ultrasonic Transducers in a Single Medium (단일 매체에서의 평면 초음파 탐촉자의 방사 음장 모델링 기법)

  • Song, Sung-Jin;Kim, Hak-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.2
    • /
    • pp.91-101
    • /
    • 2000
  • Modeling of radiation beam from ultrasonic transducers has been investigated extensively, since it is one of the most important, fundamental issues that have great influence on the accuracy of an ultrasonic measurement model. Here, three popular radiation models, namely the Rayleigh-Sommerfeld integral model, the boundary diffraction wave model and the edge element model, are discussed briefly, and the radiation beam fields from ultrasonic transducers with planar, circular and rectangular cross-sections are calculated using these three models. Then, the accuracy and the time-efficiency of these methods are compared based on the calculation results.

  • PDF

A study on the dependance of substrate material and the properties of electron beam radiation in plasma polymerized films (플라즈마 중합막의 기판재질 의존성과 전자선 조사 특성에 대한 연구)

  • 김종택;박수홍;김형권;김병수;이덕출
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.4
    • /
    • pp.410-414
    • /
    • 1998
  • The dependence of substrate material and electrode position were studied by radiation analysis of Ar discharge, and electron beam radiation was applied to confirm the crosslinked structure of the film. Comparing the conductor substrate with the insulator substrate, the former had lager peak density of radiation spectrum than latter. From the result of peak density of metastable state and ion, it was confirmed that the peak density of ion was falling to the down limit with increasing the distance of electrode by analyzing the radiation spectrum of polymerized films. When the polymerized styrene films was exposed to electron beam, it was possible to form a pattern with the insulator substrate.

  • PDF

Electrochemical Study on PVDF-HFP/Silylated Al2O3-coated PE Separators using the Electron Beam Irradiation for Lithium Secondary Battery (전자선을 이용한 PVDF-HFP/Silylated Al2O3가 코팅된 리튬 이차 전지용 폴리에틸렌 분리막의 전기화학적 특성 연구)

  • Sohn, Joon-Yong;Shin, Junhwa;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.4 no.4
    • /
    • pp.359-364
    • /
    • 2010
  • PVDF-HFP (binder)/silylated alumina (inorganic particle)-coated PE (polyethylene) separators were with various compositions of binder and inorganic particle were prepared by a dip-coating process with humidity control (R.H. 25% and 50%) using electron beam irradiation. The morphology of the coated PVDF-$HFP/Al_2O_3$ layer with various compositions of PVDF-HFP and $Al_2O_3$, and humidity condition was found to be an important factor in determining ionic conductivity of the prepared separators. The PVDF-$HFP/Al_2O_3$ (5/5)-coated PE separator prepared at R.H. 50% followed by electron beam irradiation at 200 kGy was applied for lithium-ion polymer battery and the cell test results showed improved high-rate discharge performance and better cyclic stability compared to the cells with the bare PE and the PVDF-HFP-coated PE separators.

Effect of Proton Beam Radiation on Bulbil Yield and Gibberellins of Chinese Yam (Dioscorea opposita Thunb.)

  • Kim, Sang-Kuk;Choi, Hong-Jib;Kim, Kye-Ryung;Lee, In-Jung;Kim, Hak-Yoon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.56 no.3
    • /
    • pp.250-254
    • /
    • 2011
  • The study was carried out to evaluate the affect of proton beam radiation on production of bulbil and tuber including change of endogenous gibberellins, of Dioscorea opposita Thunb. The yield of bulbils and tubers from non- and irradiated D. opposita Thunb at doses of 5, 10, 15 and 20 Gy were determined. Endogenous gibberellins were also quantified by GC/MS analysis. D. opposita tubers irradiated at 15 Gy produced higher bulbil production than non-irradiated plants. Enlarged bulbil (above size diameter 4 mm) was significantly increased at 15 Gy. Bioactive endogenous $GA_4$ was dominant in bulbils and tubers irradiated with proton beam rather than $GA_1$. Major gibberellins biosynthetic pathways in bulbils and tubers of D. opposita plants were non C-13 hydroxylation route. From the results of this study, 15 Gy proton beam radiation was suggested as an optimal dose that can produce high amounts of bulbil for mass production of D. opposita plant.

The Comparison of a Conformational Alteration of Ovalbumin Irradiated with Radiation of Gamma and Electron Beam (감마선 및 전자선 조사에 따른 Ovalbumin의 구조 변화 비교)

  • 변명우;서지현;김재훈;김미리;오남순;이주운
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.7
    • /
    • pp.1169-1174
    • /
    • 2004
  • This study was carried out to assess the effects of electron beam (EB) radiation on the conformational changes of ovalbumin (OVA), based on the early works using gamma irradiation. The applied doses of OVA used were 3,5,7, and 10 kGy, respectively. The conformational alterations were measured with SDS-PAGE, GPC-HPLC, and competitive indirect enzyme-linked immunosorbent assay (Ci-ELISA) using monoclonal anti-OVA IgG antibody. Irradiation caused a degradation and/or an aggregation of OVA molecule. Immunochemical structures of irradiated OVA were altered by irradiation. Effects of gamma and electron beam radiation were similar at the same absorbed doses. These results may be used for inhibition of food allergy and development of immunogen with EB radiation.

Germination and Seedling Growth in Response to Ionizing Radiation in Creeping Bentgrass (Agrostis palustris Huds.)

  • Lee, Yong Jin;Hong, Min Jeong;Kim, Dae Yeon;Lee, Tong Geon;Kim, Dong Sub;Kim, Jin Baek;Lee, Byung Cheol;Han, Young Hwan;Seo, Yong Weon
    • Korean Journal of Breeding Science
    • /
    • v.40 no.1
    • /
    • pp.15-21
    • /
    • 2008
  • It was previously pointed out that mutation is the ultimate source of variation. Adequate variation is needed for plant breeding if there is a limitation in natural genetic resources. When the ionizing radiation has been known to cause chromosomal and genomic alternations, it is widely used for inducing mutagenesis. The electron beam as an ionizing radiation is the principal physical mutagens that induces mutation and effectively used in plant breeding. Since dose-response relationships of electron beam in plant species are rarely known, we investigated the seed germination rate and early seedling growth of irradiated seeds of creeping bentgrass (Agrostis palustris Huds., cv Penn-A1) with various electron beam irradiating conditions (1, 1.3, 2 MeV at both 0.03 mA and 0.06 mA with dose of 100 Gy (Gray) and 0.03, 1, 1.3, 2 MeV at 0.03 mA with dose of 200 Gy, respectively) using electron accelerator at Korea Atomic Energy Research Institute. The growth parameters in terms of shoot length, primary root length, and secondary root length showed similar response between 0.06 / 1 (mA / MeV) at 100 Gy and 0.03 / 0.3 (mA / MeV) at 200 Gy. Bentgrass seed germination was mainly affected by the intensity of irradiated dose (Gray). Germination rate was lowered as the irradiated dose increased. On the other hand, early seedling growth was mainly governed not by the dose of radiation but by voltage.