• Title/Summary/Keyword: Bay Controller

Search Result 10, Processing Time 0.034 seconds

A Study on the Design of the Bay Controller for Generator Protection and Control (발전기 보호제어를 위한 Bay Controller 설계에 관한 연구)

  • Jang, Nak-Won;Woo, Chun-Hee;Lee, Sung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.46-55
    • /
    • 2008
  • In this paper, we designed the bay control unit that is based on the microprocessors and integrates with the new technology of electrical, electronic, and mechanical fields. Nowadays the customers have required much more integrated multi-protection relay, monitoring, control devices and power management for better and easier maintenance, performance, electrical system analysis and communication according to new trend of switchboard This bay controller supplies those requirements of customers with easy handling and operation. This bay controller provides a graphic display with rear-lit liquid crystal LCD and push buttons as kinds of HMI(Human Machine Interface). This bay controller provides the parameter setting program, control setting program, various editors and fault recording and analysis program on Windows/95/98/NT/2000/XP for HMI. In addition, this bay controller can be set manually and this manual setting function helps user to interface easily.

A Design of the Multifunction Bay Controller (다기능 Bay Controller 설계)

  • Lee, Sung-Hwan;Jang, Nak-Won;Woo, Chun-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.146-148
    • /
    • 2007
  • In this paper, we designed the bay control unit that is based on the microprocessors and integrates with the new technology of electrical, electronic, and mechanical fields. Nowadays the customers have required much more integrates multi protection relay, monitoring, control devices and power management for better and easier maintenance, performance, electrical system analysis and communication according to new trend of switchboard. This bay controller supplies those requirements of customers with easy handling and operation. This bay controller provides a graphic display with rear-lit liquid crystal LCD and push buttons as kinds of HMI. This bay controller provides the parameter setting program, various editors and fault recording and analysis program on Windows/95/98/NT/2000/XP for HMI. In addition, this bay controller can be set manually and this manual setting function helps user to interface easily.

  • PDF

The Implementation of Bay Controller for High-voltage GIS based on IEC61850 (IEC61850 기반 GIS용 Bay Controller의 시제품 제작)

  • Woo, Chun-Hee;Lee, Bo-In;Ahn, Hyeong-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.341-342
    • /
    • 2008
  • 기존의 디지털 보호 계전기는 인입용, 피더용 보호계 전기로 분류되어 각각 계통을 보호하는 방식을 취하고 있으나, 다수의 계전기를 Bay 레벨에서 통합하고, Bay 레벨의 모니터링과 컨트롤 기능과 같은 새로운 기능들을 요구하는 추세이다. 국내 계통 보호협조를 원활히 수행하고 기능 연계를 통한 전력 공급의 안정을 도모하기 위해서는 국내 기술진에 의해 개발된 Bay Controller의 설치 운영은 필수적이라 생각되며, 또한 유지보수 관리 및 시스템 분석 기능을 부가적으로 제공함으로서, 사용자가 손쉽게 시스템을 운영할 수 있도록 개발하였다.

  • PDF

The Development and the Performance Test of Bay Controller for the High-Voltage Gas Insulated Switchgear (초고압 가스절연개폐기의 베이 컨트롤러 개발 및 성능시험)

  • Woo, Chun-Hee;Lee, Bo-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.179-184
    • /
    • 2010
  • The digital substation automation system has contributed hugely to increasing the stability of power systems by providing not only protection and control of power systems but diagnostic features alongside them. Digital substation automation systems in the scale of substations consist of integrated operation systems and intelligent electronic devices. The main intelligent electronic devices currently in use are digital protection relays and the bay controllers in Gas insulated switchgears. Proficiently accomplishing the coordination of protection within the power system as a means of ensuring reliability and contriving for the stability of power supply through connection of function, the application of bay controllers is crucial, which collectively manage the protection relay at the bay level in order to achieve both. In this research, the bay controllers to be used in high-voltage Gas insulated switchgear has been localized, and in particular, the logic function and editor required in order to minimize the complicated hardware-like cable connections in the local panel have been developed. In addition, to ensure the strength and reliability of the bay controller hardware developed herein, the type tests from KERI have been successfully completed.

Development of Bay Controller for 170kV GIS (170kV GIS용 Bay Controller 개발)

  • Kim, Min-Soo;Jung, Jung-Ryong;Kim, Jung-Bae;Lee, Hahk-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1324-1325
    • /
    • 2008
  • 근래 선진 중전기 메이커에서는 차단기, GIS 등의 전통적인 단품 위주에서 탈피하여 전력 IT 기술을 접목한 전력기기/변전소 자동화를 강력하게 추진하고 있다. 특히 전체 변전소를 감시, 제어, 계측, 보호할 수 있도록 전력 IT 기술을 기반으로 한 IEC 61850 적용 변전소 종합 자동화 시스템 개발에 역량을 집중하고 있다. 본 논문에서는 당사에서 개발한 최신 IT 기술을 적용한 IEC 61850 기반 170㎸ GIS용 Bay Controller 관련 구성, 기능, 성능시험 결과에 대해 기술하며, 변전소 내 노이즈로 인해 유발될 수 있는 전자장치 오동작 등을 보증하기 위해 실시한 전자파 장해시험 결과와 GIS와 동일한 환경에 설치되므로 온/습도, 진동/충격시험을 관련 국제규격인 IEC 60255-6, IEC 60255-21-1, 2, 3에 의거하여 실시한 내용을 기술하도록 한다.

  • PDF

A study on The Fuzzy Based PID Position controller for Step Motor Drives

  • Kim, Seung-Cheol;Cho, Yong-Sung;Park, Jae-Hyung;Kang, Shin-Chul;Bay, Gyu-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1496-1499
    • /
    • 2005
  • In this paper, we applied step motor drive using a fuzzy logic control based on PID controller. A designed this controller's purpose is improved robust and autonomous characteristic in which the variation of external load affects plant parameter. Therefore, in this paper, using a fuzzy logic control based on PID controller of two fuzzy-PI and fuzzy-D is obtained decremental overshoot and a special response quality.

  • PDF

Automatic Berthing Control of Ship Using Adaptive Neural Networks

  • Nguyen, Phung-Hung;Jung, Yun-Chul
    • Journal of Navigation and Port Research
    • /
    • v.31 no.7
    • /
    • pp.563-568
    • /
    • 2007
  • In this paper, an adaptive neural network controller and its application to automatic berthing control of ship is presented. The neural network controller is trained online using adaptive interaction technique without any teaching data and off-line training phase. Firstly, the neural networks used to control rudder and propeller during automatic berthing process are presented. Secondly, computer simulations of automatic ship berthing are carried out in Pusan bay to verify the proposed controller under the influence of wind disturbance and measurement noise. The results of simulation show good performance of the developed berthing control system.

245kV Motor-drive type high-voltage Gas Insulated Switchgear(GIS) based on IT technology (IT 기술 기반 245kV Motor-drive형 초고압 GIS 개발)

  • Seo, Kyung-Bo;Yeo, Chang-Ho;Kim, Jung-Bea;Song, Won-Pyo;Lee, Hak-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.368-369
    • /
    • 2008
  • 현재 국내 중전기 시장은 시장규모에 비해 다수의 기업이 참여하고 있기 때문에, 국내 중전기 업체간 정쟁은 더욱 심화되고 있다. 따라서 국내 중전기 업체가 더욱 발전해 나아가기 위해서는 해외시장 진출 확대를 위한 수출용 전적기기의 개발이 시급하고, WTO 체제하의 시장 개방화 정책에 따른 국내외시장에서의 User의 요구에 부응하는 전력기기 개발이 절실히 요구되어 당사에서는 국책과제로써 IT 기술을 기반으로 하는 245kV Motor-drive형 초고압 GIS를 개발하게 되었다. 금번에 개발된 절연개폐장치는 변전소 자동화라는 세계적 추세에 맞추어 Bay Controller 및 전자식 변성기(NCIT)를 적용하였고, 자체 참고시험을 통해 확보된 피시품을 가지고 국제공인인증기관인 한국전기연구원(KERI)에서 IEC 국제규격에 준하여 그 성능을 검증하였다.

  • PDF

The Development of Dual Structured Power Management System (이중화 구조를 가진 변전소자동화시스템의 개발)

  • Woo, Chun-Hee;Lee, Bo-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.275-288
    • /
    • 2010
  • In order to improve the quality of electricity in large scale power systems, stability of power system has to be achieved. This can be done by the means of preventative diagnosis of power equipments and protection, monitoring and control of the power system. Since the recent adoption of digital controllers, an improvement in stability was observed; in particular, IED, which contained self-diagnostic abilities such as fault tolerance, allowed for automatic recovery via redundancy or switching-over functions should there be faults with the equipments. Furthermore, communication lines have been hugely simplified, thus adding to the improvement in stability significantly. Taking these error reports and forecasting emergency reports and by effectively responding to them in the overiding controlling systems, high levels of system stability can be obtained. Power Management System that is being applied to automated power sub-stations, takes the IEC61850 international standard as its specification. In this paper, additional research into achieving stability of already developed PMS system and also the stability of the overall system was carried out, and the results of development of communication servers, which play a pivotal role in connecting systems, are stated.

Analysis on the volume variation of bag-net in set-net by acoustic telemetry (음향 텔레메트리에 의한 정치망 원통의 체적 변화 해석)

  • Tae, Jong-Wan;Shin, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.2
    • /
    • pp.115-125
    • /
    • 2004
  • An experiment to measure the volume variation of bag net in a set-net by acoustic telemetry system was conducted in Jaran Bay, Gosung, Korea on 10 April to 23 April 2003. The long baseline telemetry system consists of three radio-acoustic linked positioning (RAP) buoys, a time controller with a personal computer and seven pingers. Six pingers were attached on the bottom of the bag-net and the other one was fixed on the sea bed. The results obtained are summarized as follows : 1. The average RAP buoy fixing errors of x-axis, y-axis, and z-axis were 0.2m, 0.4m, and 0.1m, respectively. 2. In the neap tide the minimum and maximum volume of the bag-net on 11 April 2003 were 4,173$m^3$(17:00) and 4,757$m^3$(12:00), respectively. The average current direction and speed at those times were 99.9$^{\circ}$, 12.9cm/s and 104.0$^{\circ}$, 2.4cm/s, respectively. 3. In the spring tide on 17 April 2003, the minimum and maximum volume were 2,016$m^3$(18:30) and 4,454$m^3$(15:00), respectively. The average current direction and speed at those times were 315.6$^{\circ}$, 16.1cm/s and 289.0$^{\circ}$, 5.7cm/s, respectively. 4. In conclusion the maximum variation of the volume on 17 April to 20 April 2003 was 3,552$m^3$ and it was larger 1.4 times than time on 11 April to 16 April 2003.