• Title/Summary/Keyword: Battery.

Search Result 5,917, Processing Time 0.036 seconds

The change of validity of blood zinc protoporphyrin test by different cut-off level in lead workers (연취급 근로자들의 혈중 ZPP 농도 선별기준에 따른 정확도의 변화)

  • Kim, Yong-Bae;Ahn, Hyun-Cheol;HwangBo, Young;Lee, Gap-Soo;Lee, Sung-Soo;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.741-751
    • /
    • 1997
  • Measurement of blood lead (PbB) and blood zinc protoporphyrin (ZPP) are most common biological indices to identify the individual at risk for excess or the health sequences by lead exposure. Because PbB is known most important and reliable index of lead exposure, PbB is often regarded as a gold standard to detect lead exposure. But in Korea PbB is a secondary test item of detailed health check-up with positive finding of screening test in most occasion. Our lead standard requires all lead workers to take annual heath-check twice a year for investigation of their health effect due to lead exposure. Blood ZPP is one of most important index to detect high lead absorption in lead workers as a screening test. Measurement of blood ZPP is known ,well to correlate with PbB in steady state of exposure in most lead workers and is often used as a primary screening test to detect high lead absorption of lead workers with the advantage of simplicity, easiness, portability and low cost. The current cut-off criteria of blood ZPP for further detailed health check-up is $100{\mu}g/d\ell$ which is supposed to match the level of $40{\mu}g/d\ell$ of PbB according to our standard. Authors tried to investigate the validity of current criteria of cut-off level $(100{\mu}g/d\ell)$ of blood ZPP and possible another better cut-off level of it to detect the lead workers whose PbB level over $40{\mu}g/d\ell$. The subjects in our study were 212 male workers in three small scale storage battery industries. Blood ZPP, PbB and hemoglobin (Hb) were selected as the indices of lead exposure. The results were as follows. 1. The mean of blood ZPP, PbB and Hb in lead workers were $79.5{\pm}46.7{\mu}g/d\ell,\;38.7{\pm}15.1{\mu}g/d\ell,\;and\;14.8{\pm}1.2g/d\ell$, respectively. There were significant differences in blood ZPP, PbB and Hb by industry (P<0.01). 2. The percents of lead workers whose blood ZPP were above $100{\mu}g/d\ell$ in the group of work duration below 1, 1-4, 5-9 and above 10 years were 8.6%, 17.2%, 47.6%, and 50.0%, respectively. The percents of lead workers whose PbB were above $40{\mu}g/d\ell$ in those were 31.4%, 40.4%, 71.4%, and 86.4%, respectively. 3. The percents of lead workers whose PbB were below $40{\mu}g/d\ell$, $40-59{\mu}g/d\ell$ and above $60{\mu}g/d\ell$ were 54.7%, 34.9% and 10.4%, respectively. Those of lead workers whose blood ZPP were below $100{\mu}g/d\ell$, $100-149{\mu}g/d\ell$ and above $150{\mu}g/d\ell$ were 79.2%, 13.7% and 7.1%, respectively. 4. Simple linear regression of PbB on blood ZPP was statistically significant (P<0.01) and as PbB was $40{\mu}g/d\ell$, blood ZPP was $82.1{\mu}g/d\ell$. 5. While the highest sensitivity and specificity of blood ZPP test to detect lead workers with PbB eve. $40{\mu}g/d\ell$ were observed in the cut-off level of $50{\mu}g/d\ell$ and $100{\mu}g/d\ell$ of blood ZPP, respectively, the highest validity (sensitivity+specificity) of blood ZPP to detect lead workers with PbB over $40{\mu}g/d\ell$ was observed in the cut-off level of around $70{\mu}g/d\ell$ of blood ZPP. But even with optimal cut-off level of around $70{\mu}g/d\ell$ of blood ZPP, still 25.0% of false negative and 20.7% false positive lead workers were found. As the result of this study, it was suggested that reconsideration of current blood ZPP cut-off of our lead standard from $100{\mu}g/d\ell$ to somewhat lower level such as around $70{\mu}g/d\ell$ and the inclusion of PbB measurement as a primary screening test for lead workers was highly recommended for the effective prevention of lead workers.

  • PDF

Studies on the Anticoccidial Efficacy of an Unique Polyether Ionophorous Antibiotic, Maduramicin Ammonium in Comparison with Salinomycin Sodium and Monensin Sodium for Broiler Chicks (폴리에텔계 항생제인 Maduramicin ammonium, Salinomycin sodium 및 Monensin sodium이 육계에 있어서 항콕시듐 효능과 증체에 미치는 영향에 관한 연구)

  • 장두환;조영웅;윤희정;강세원
    • Korean Journal of Poultry Science
    • /
    • v.12 no.2
    • /
    • pp.127-134
    • /
    • 1985
  • Battery trial with 240 broiler chicks of Hubbard strain was conducted for a period of 2 weeks in order to compare the anticoccidical efficacy of polyether ionophorous antibiotics ; Maduramicin ammonium, Monensin and Salinomyc in sodium. The criteria used in these anticoccidial efficacy studies were anticoccidial index, growth rate, feed efficiency, mortality, lesion score and the number of oocysts produced after artificial inoculation with 70,000 sporulated oocysts of Eimeria tenella(90%) and E.necatrix (10%) to each bird. The result obtained are summarized as follow: 1. All groups medicated anticoccidial feed additives improved body weight gain and feed efficiency. However, it was found that the group medicated with Maduramicin showed better body weight gain (352.5 and 648.8 g) and feed efficiency(1.603 and 1.680) during the first and the second week experiments, 2. The mortality rate(4.2%) and lesion scores (1.72) of Maduramicin medicated group, from artificial coccidiosis were comparatively lower than those of other two medicated groups, 3. It was also found that oocyst output (0.25 ${\times}$ 10$^4$) in Maduramicin medicated group were lower than those of other two groups. 4. Anticoccidial indexes during the first week were 177.9 in Maduramicin medica-group, 158.7 in Salinomycin medicated group, 141.6 in Monensin medicated group and 78.0 in infected, nonmedicated group as compared with 200.0 in noninfected, nonmedicated group (NNC) 5. Anticoccidial indexes during the second week were 201.1 in Maduramicin group 184.0 in infected, nonmedicated group as compared with 200.0 in noninfected, nonmedicated group (NNC).

  • PDF

Analyses of the Studies on Cancer-Related Quality of Life Published in Korea (암 환자 삶의 질에 대한 국내 연구논문 분석)

  • Lee Eun-Hyun;Park Hee Boong;Kim Myung Wook;Kang Sunghee;Lee Hye-Jin;Lee Won-Hee;Chun Mison
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.359-366
    • /
    • 2002
  • Purpose : The purpose of the present study was to analyze and evaluate prior studies published in Korea on the cancer-related quality of life, in order to make recommendations for further research. Materials and Methods : A total of 31 studies were selected from three different databases. The selected studies were analyzed according to 11 criteria, such as site of cancer, domain, independent variable, research design, self/proxy rating, single/battery instrument, translation/back translation, reliability, validity, scoring, and findings. Results : Of the 31 studies, approximately half of them were conducted using a mixed cancer group of patients. Many of the studies asserted that the concept of quality of life had a multidimensional attribute. Approximately 30% were longitudinal design studies giving information about the changes in quality of life. In all studies, except one, patients directly rated their level of quality of life. With respect to the questionnaires used for measuring the quality of life, most studies did not consider whether or not their reliability and validity had been established. In addition, when using questionnaires developed in other languages, no studies employed a translation/ back-translation technique. All studies used sum or total scoring methods when calculating the level of quality of life. The types of variables tested for their influence on qualify of life were quite limited. Conclusion : It is recommended that longitudinal design studies be peformed, using methods of data collection whose validity and reliability has been confirmed, and that studies be conducted to identify new variables having an influence on the quality of life.

Wearable Computers

  • Cho, Gil-Soo;Barfield, Woodrow;Baird, Kevin
    • Fiber Technology and Industry
    • /
    • v.2 no.4
    • /
    • pp.490-508
    • /
    • 1998
  • One of the latest fields of research in the area of output devices is tactual display devices [13,31]. These tactual or haptic devices allow the user to receive haptic feedback output from a variety of sources. This allows the user to actually feel virtual objects and manipulate them by touch. This is an emerging technology and will be instrumental in enhancing the realism of wearable augmented environments for certain applications. Tactual displays have previously been used for scientific visualization in virtual environments by chemists and engineers to improve perception and understanding of force fields and of world models populated with the impenetrable. In addition to tactual displays, the use of wearable audio displays that allow sound to be spatialized are being developed. With wearable computers, designers will soon be able to pair spatialized sound to virtual representations of objects when appropriate to make the wearable computer experience even more realistic to the user. Furthermore, as the number and complexity of wearable computing applications continues to grow, there will be increasing needs for systems that are faster, lighter, and have higher resolution displays. Better networking technology will also need to be developed to allow all users of wearable computers to have high bandwidth connections for real time information gathering and collaboration. In addition to the technology advances that make users need to wear computers in everyday life, there is also the desire to have users want to wear their computers. In order to do this, wearable computing needs to be unobtrusive and socially acceptable. By making wearables smaller and lighter, or actually embedding them in clothing, users can conceal them easily and wear them comfortably. The military is currently working on the development of the Personal Information Carrier (PIC) or digital dog tag. The PIC is a small electronic storage device containing medical information about the wearer. While old military dog tags contained only 5 lines of information, the digital tags may contain volumes of multi-media information including medical history, X-rays, and cardiograms. Using hand held devices in the field, medics would be able to call this information up in real time for better treatment. A fully functional transmittable device is still years off, but this technology once developed in the military, could be adapted tp civilian users and provide ant information, medical or otherwise, in a portable, not obstructive, and fashionable way. Another future device that could increase safety and well being of its users is the nose on-a-chip developed by the Oak Ridge National Lab in Tennessee. This tiny digital silicon chip about the size of a dime, is capable of 'smelling' natural gas leaks in stoves, heaters, and other appliances. It can also detect dangerous levels of carbon monoxide. This device can also be configured to notify the fire department when a leak is detected. This nose chip should be commercially available within 2 years, and is inexpensive, requires low power, and is very sensitive. Along with gas detection capabilities, this device may someday also be configured to detect smoke and other harmful gases. By embedding this chip into workers uniforms, name tags, etc., this could be a lifesaving computational accessory. In addition to the future safety technology soon to be available as accessories are devices that are for entertainment and security. The LCI computer group is developing a Smartpen, that electronically verifies a user's signature. With the increase in credit card use and the rise in forgeries, is the need for commercial industries to constantly verify signatures. This Smartpen writes like a normal pen but uses sensors to detect the motion of the pen as the user signs their name to authenticate the signature. This computational accessory should be available in 1999, and would bring increased peace of mind to consumers and vendors alike. In the entertainment domain, Panasonic is creating the first portable hand-held DVD player. This device weight less than 3 pounds and has a screen about 6' across. The color LCD has the same 16:9 aspect ratio of a cinema screen and supports a high resolution of 280,000 pixels and stereo sound. The player can play standard DVD movies and has a hour battery life for mobile use. To summarize, in this paper we presented concepts related to the design and use of wearable computers with extensions to smart spaces. For some time, researchers in telerobotics have used computer graphics to enhance remote scenes. Recent advances in augmented reality displays make it possible to enhance the user's local environment with 'information'. As shown in this paper, there are many application areas for this technology such as medicine, manufacturing, training, and recreation. Wearable computers allow a much closer association of information with the user. By embedding sensors in the wearable to allow it to see what the user sees, hear what the user hears, sense the user's physical state, and analyze what the user is typing, an intelligent agent may be able to analyze what the user is doing and try to predict the resources he will need next or in the near future. Using this information, the agent may download files, reserve communications bandwidth, post reminders, or automatically send updates to colleagues to help facilitate the user's daily interactions. This intelligent wearable computer would be able to act as a personal assistant, who is always around, knows the user's personal preferences and tastes, and tries to streamline interactions with the rest of the world.

  • PDF

CNT-Ni-Fabric Flexible Substrate with High Mechanical and Electrical Properties for Next-generation Wearable Devices (차세대 웨어러블 디바이스를 위한 높은 기계적/전기적 특성을 갖는 CNT-Ni-Fabric 유연기판)

  • Kim, Hyung Gu;Rho, Ho Kyun;Cha, Anna;Lee, Min Jung;Ha, Jun-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.2
    • /
    • pp.39-44
    • /
    • 2020
  • Recently, numerous researches are being conducted in flexible substrate to apply to wearable devices. Particularly, Conductive substrate researches that can implement the wearable devices on clothing are massive. In this study, we formed fiber substrate spraying CNT and Pd mixed solution on it and plated metal layer with electroless plating. Used SEM equipment and EDS analysis to analysis structure of the plated fiber substrate and discovered Ni layer was created. For check electrical properties, mapping was performed to check surface resistance and distribution of resistance of electroless plated fiber substrate with 4-point probe. It was confirmed that conductivity was improved as the duration of electroless plating was increased, and it was found that distribution of resistance by surface location was uniform. Changes in resistance due to mechanical stress were measured through tensile, bending, and twisting tests. As a result, it was confirmed that resistance change of flexible substrate gradually disappeared as plating time increased. Using UTM (Universal testing machine), it was analyzed mechanical properties of the electroless plated substrate with respect to changes in plating time were improved. In the case of conductive fiber substrate in which electroless plating was performed for 2 hours, tensile strength was increased by 16 MPa than fiber substrate. Based on these results, we found that Ni-CNT-Fabric flexible substrate is adequate for clothing-intergrated conductive substrate and we positively expect that this experiment shows flexible substrate can adapt to and develop not only a wearable device technology but also other fields needing flexibility such as battery, catalyst and solar cell.

Relationship between Sleep Disturbances and Cognitive Impairments in Older Adults with Depression (노인성 우울증 환자에서 수면 장애와 인지기능 저하의 관련성)

  • Lee, Hyuk Joo;Lee, Jung Suk;Kim, Tae;Yoon, In-Young
    • Sleep Medicine and Psychophysiology
    • /
    • v.21 no.1
    • /
    • pp.5-13
    • /
    • 2014
  • Objectives: Depression, sleep complaints and cognitive impairments are commonly observed in the elderly. Elderly subjects with depressive symptoms have been found to show both poor cognitive performances and sleep disturbances. However, the relationship between sleep complaints and cognitive dysfunction in elderly depression is not clear. The aim of this study is to identify the association between sleep disturbances and cognitive decline in late-life depression. Methods: A total of 282 elderly people who underwent nocturnal polysomnography in a sleep laboratory were enrolled in the study. The Korean version of the Neuropsychological Assessment Battery developed by the Consortium to Establish a Registry for Alzheimer's Disease (CERAD-K) was applied to evaluate cognitive function. Depressive symptoms were assessed with the geriatric depression scale (GDS) and subjective sleep quality was measured using the Pittsburg sleep quality index (PSQI). Results: The control group ($GDS{\leq}9$) when compared with mild ($10{\leq}GDS{\leq}16$) and severe ($17{\leq}GDS$) depression groups, had significantly different scores in the Trail making test part B (TMT-B), Benton visual retention test part A (BVRT-A), and Stroop color and word test (SCWT)(all tests p<0.05). The PSQI score, REM sleep duration, apnea-hypopnea index and oxygen desaturation index were significantly different across the three groups (all indices, p<0.05). A stepwise multiple regression model showed that educational level, age and GDS score were predictive for both TMT-B time (adjusted $R^2$=35.6%, p<0.001) and BVRT-A score (adjusted $R^2$=28.3%, p<0.001). SCWT score was predicted by educational level, age, apnea-hypopnea index (AHI) and GDS score (adjusted $R^2$=20.6%, p<0.001). Poor sleep quality and sleep structure alterations observed in depression did not have any significant effects on cognitive deterioration. Conclusion: Older adults with depressive symptoms showed mild sleep alterations and poor cognitive performances. However, we found no association between sleep disturbances (except sleep apnea) and cognitive difficulties in elderly subjects with depressive symptoms. It is possible that the impact of sleep disruptions on cognitive abilities was hindered by the confounding effect of age, education and depressive symptoms.

Study on LiFePO4 Composite Cathode Materials to Enhance Thermal Stability of Hybrid Capacitor (하이브리드 커패시터의 열안정성 개선을 위한 LiFePO4 복합양극 소재에 관한 연구)

  • Kwon, Tae-Soon;Park, Ji-Hyun;Kang, Seok-Won;Jeong, Rag-Gyo;Han, Sang-Jin
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.242-246
    • /
    • 2017
  • The application of composite cathode materials including $LiFePO_4$ (lithium iron phosphate) of olivine crystal structure, which has high thermal stability, were investigated as alternatives for hybrid battery-capacitors with a $LiMn_2O_4$ (spinel crystal structure) cathode, which exhibits decreased performance at high temperatures due to Mn-dissolution. However, these composite cathode materials have been shown to have a reduction in capacity by conducting life cycle experiments in which a $LiFePO_4$/activated carbon cell was charged and discharged between 1.0 V and 2.3 V at two temperatures, $25^{\circ}C$ and $60^{\circ}C$, which caused a degradation of the anode due to the lowered voltage in the anode. To avoid the degradation of the anode, composite cathodes of $LiFePO_4/LiMn_2O_4$ (50:50 wt%), $LiFePO_4$/activated carbon (50:50 wt%) and $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ (50:50 wt%) were prepared and the life cycle experiments were conducted on these cells. The composite cathode including $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ of layered crystal structure showed stable voltage behavior. The discharge capacity retention ratio of $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ was about twice as high as that of a $LiFePO_4/LiMn_2O_4$ cell at thermal stability experiment for a duration of 1,000 hours charged at 2.3 V and a temperature of $80^{\circ}C$.

Analysis on the Cooling Efficiency of High-Performance Multicore Processors according to Cooling Methods (기계식 쿨링 기법에 따른 고성능 멀티코어 프로세서의 냉각 효율성 분석)

  • Kang, Seung-Gu;Choi, Hong-Jun;Ahn, Jin-Woo;Park, Jae-Hyung;Kim, Jong-Myon;Kim, Cheol-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.7
    • /
    • pp.1-11
    • /
    • 2011
  • Many researchers have studied on the methods to improve the processor performance. However, high integrated semiconductor technology for improving the processor performance causes many problems such as battery life, high power density, hotspot, etc. Especially, as hotspot has critical impact on the reliability of chip, thermal problems should be considered together with performance and power consumption when designing high-performance processors. To alleviate the thermal problems of processors, there have been various researches. In the past, mechanical cooling methods have been used to control the temperature of processors. However, up-to-date microprocessors causes severe thermal problems, resulting in increased cooling cost. Therefore, recent studies have focused on architecture-level thermal-aware design techniques than mechanical cooling methods. Even though architecture-level thermal-aware design techniques are efficient for reducing the temperature of processors, they cause performance degradation inevitably. Therefore, if the mechanical cooling methods can manage the thermal problems of processors efficiently, the performance can be improved by reducing the performance degradation due to architecture-level thermal-aware design techniques such as dynamic thermal management. In this paper, we analyze the cooling efficiency of high-performance multicore processors according to mechanical cooling methods. According to our experiments using air cooler and liquid cooler, the liquid cooler consumes more power than the air cooler whereas it reduces the temperature more efficiently. Especially, the cost for reducing $1^{\circ}C$ is varied by the environments. Therefore, if the mechanical cooling methods can be used appropriately, the temperature of high-performance processors can be managed more efficiently.

The Clinical Aspects of Wild Plant Poisoning (야생식물 중독의 임상 양상)

  • Ok, Taek-Gun;Park,, Chan-Woo;Cho, Jun-Hwi;Cheon, Seung-Whan;Lee, Seung-Young;Kim,, Sung-Eun;Choi, Ki-Hoon;Bae, Ji-Hoon;Seo, Jeong-Yeul;Ahn, Hee-Cheol;Ahn, Moo-Eob;Cho, Byung-Ryul;Kim,, Yong-Hoon
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.3 no.2
    • /
    • pp.79-85
    • /
    • 2005
  • Purpose: With the recent boom in 'eating healthy', many adults are interested in dieting to prevent future diseases. However only well trained experts can distinguish between what are edible vegetables and herbs from their poisonous look-alikes. In cases where a patient unknowingly ingests a poisonous herb, is caught off guard by the poisonous side effects that occur because of their lack of knowledge of what they have ingested. This paper will focus on the need to educate the public about the risks involved with ingesting wild vegetables and herbs and study the emergency diagnosis and treatment of poisoned patients that enter the emergency room. Method: This study was done in the spring of 2004 (from March to May) in the Kangwon Young-Seo districts of Korea. 15 subjects used in this study, entered the emergency room showing signs of toxic symptoms. Data was collected by examining subject's records. Additional data was collected by collaborating with physicians in the hospital that diagnosed and treated the subjects. Identifying the poisonous vegetable or herb is the first step to proper diagnosis and treatment. Subjects admitted to the emergency room, underwent a battery of tests: laboratory examination, ECG, radiological exam and etc. Results: The demographics of the study encompassed subjects with the average age of $50{\pm}19$ years old. There were 10 men and 5 women. Common symptoms of this study included; gastrointestinal symptoms such as nausea, vomiting, epigastric pain and so on. In the case of Caltha palustris ingestion, additional symptoms were present; bradycardia and hypotension which lasted for a long time. While cases that ingested Scopolia parviflora had little effect on vital signs but manic episodes lasted for about three days. Veratrum patulum ingestion showed signs of bradycardia and hypotension but contrary to Caltha palustris recovery was shorten by treating with dopamine. However, dizziness, headache and paresthesia of the extremities continued for a long time. Finally Sium ninsi ingestion showed visual disturbance, paresthesia of the extremities, dizziness as their initial symptoms. Conclusion: The risks involved with ingesting wild plants without the proper knowledge can lead to serious side effects and steps need to be taken to educate the public. In addition, all emergency physicians need to have a working knowledge of the symptoms and signs associated with ingesting toxic wild plants and need to treat accordingly.

  • PDF

Synthesis and Electrochemical Properties of Carbon Coated Li4Ti5O12 using PVC (PVC를 원료로 탄소코팅한 Li4Ti5O12의 합성 및 전기화학적 특성)

  • Hyun, Si-Cheol;Na, Byung-Ki
    • Clean Technology
    • /
    • v.24 no.1
    • /
    • pp.77-84
    • /
    • 2018
  • In this study, $Li_4Ti_5O_{12}$ anode materials for lithium ion battery were synthesized by dry ball-mill method. Polyvinyl chloride (PVC) as a carbon source was added to improve electrochemical properties. When the PVC was added after $Li_4Ti_5O_{12}$ formation, the spinel structure was well synthesized and it was confirmed by X-ray diffraction (XRD) experiments. When the carbon material was added before the synthesis and the heat treatment was performed, it was confirmed that a material having a different crystal structure was synthesized even when a small amount of carbon material was added. In the case of $Li_4Ti_5O_{12}$ without the carbon material, the electrical conductivity value was about $10{\mu}S\;m^{-1}$, which was very small and similar to that of the nonconductor. As the carbon was added, the electrical conductivity was greatly improved and increased up to 10,000 times. Electrochemical impedance spectroscopy (EIS) analysis showed that the size of semicircle corresponding to the resistance decreased with the carbon addition. This indicates that the resistance inside the electrode is reduced. According to the Cyclic voltammetry (CV) analysis, the potential difference between the oxidation peak and the reduction peak was reduced with carbon addition. This means that the rate of lithium ion insertion and deinsertion was increased. $Li_4Ti_5O_{12}$ with 9.5 wt% PVC added sample showed the best properties in rate capabilities of $180mA\;h\;g^{-1}$ at 0.2 C-rate, $165mA\;h\;g^{-1}$ at 0.5 C-rate, and $95.8mA\;h\;g^{-1}$ at 5 C-rate.