• Title/Summary/Keyword: Baths

Search Result 175, Processing Time 0.023 seconds

GOLD WIRE BONDABILITY OF ELECTROLESS GOLD PLATING USING DISULFITEAURATE COMPLEX

  • Abe, Shinji;Watanabe, Hideto;Igarashi, Yasushi;Honma, Hideo
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.714-719
    • /
    • 1996
  • For the fabrication of the circuits, contact or terminal areas are usually coated with nickel and gold. Usually, diluted palladium solution is applied to initiate electroless nickel plating on the copper circuits. However, the trace amounts of palladium remains on the resin and it causes the extraneous deposition. We confirmed that selectivity was greatly improved by the treatment with the strong reducing agents such as SBH or DMAB. Bondability was greatly influenced by the contents of phosphorus in the deposited nickel. Stabilizers in the electroless gold plating were also influenced the bonding strength. The baths containing cupferron or potassium nickel cyanide as a stabilizer showed superior bondability. The gold deposits having strong orientation with Au(220) and Au(311) showed good bond ability.

  • PDF

Waterborne Pathogens Identification in Public Bathroom by PCR-Reverse Blot Hybridization Assay

  • Choi, Seung-Gu;Song, Woon-Heung;Lee, Jae-Sang;Yang, Byoung-Seon;Choi, Myeong-Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.43 no.3
    • /
    • pp.120-123
    • /
    • 2011
  • A total of 30 water samples were collected from 30 different public baths in Seoul, Korea. Contamination of public bath water by waterborne pathogens can cause disease outbreaks and contribute to increase background rates of disease. Pathogens in water was filtered by nitrocellulose membrane with $0.45{\mu}m$ pore size. The membrane filters were analyzed by both cultivation and polymerase chain reaction (PCR) amplification of partial 16S rRNA gene. Various microorganisms including 4 Escherichia coli/Shigella spp. 1 Salmonella spp. 3 Pseudomonas aeruginosa and 2 Mycobacterium spp. were identified by reverse blot hybridization assay (REBA). PCR-REBA was able to identify many bacterial genera in one assay. Our results suggest that appropriate hygiene practice and continuous monitoring is needed for reducing health risk associated with public bath houses.

  • PDF

Computer Simulation of Hardenability Characteristics of Alloy Steel for Structural Purposes (컴퓨터 시뮬레이션에 의한 구조용 합금강의 경화능특성 해석)

  • Kim, K.S.;Hong, C.P.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.2 no.2
    • /
    • pp.1-10
    • /
    • 1989
  • In this study, the specimens of SCM 22 H steel were quenched in oil and water baths at various agitation conditions in order to investigate the effects of quenchants and agitation conditions on the quench-hardening. A multi-channel temperature measurement apparatus was employed to obtain the cooling curves at several predetermined positions of specimens. Microstructural observation and hardness test were also carried out. Computer simulation of heat treating process was carried out using the modified finite difference method. Prediction of thermal history and hardness distribution by 2-dimensional computer analysis was in good agreement with the experimental results. It was found that the quantitative design of heat treating process can be made by the computer aided heat-treating analysis.

  • PDF

Electroless Ni-P layer Characteristics in accordance with the plating process conditions (무전해 Ni-P 도금의 공정조건에 따른 도금피막 특성변화)

  • Lee Hong-Kee;Jeon Jun-Mi;Park Hae-Duck
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.3
    • /
    • pp.263-271
    • /
    • 2003
  • Optimal conditions of electroless nickel plating in acid baths has been studied for industrial applications of a developed EN solution. The phosphorus content in the deposition ranges from 8 to $12\;wt.\%$. The investigated EN plating parameters are ion concentrations of nickel and hypophosphite, concentration of reducing and complexing agent, temperature, and pH. The average plating rate of Ni-P deposition was ca. $14{\mu}m/h$. The EN solution used shows a deposition rate of $10{\mu}m/h$ up to seven metal turnovers.

Electrodeposition of GMR Ni/Cu Multilayers in a Recirculating Electrochemical Flow Reactor

  • Rheem, Young-Woo
    • Korean Journal of Materials Research
    • /
    • v.20 no.2
    • /
    • pp.90-96
    • /
    • 2010
  • The recirculating electrochemical flow reactor developed at UCLA has been employed to fabricate nanostructured GMR multilayers. For comparison, Ni/Cu multilayers have been electrodeposited from a single bath, from dual baths and from the recirculating electrochemical flow reactor. For a magnetic field of 1.5 kOe, higher GMR (Max. -5%) Ni/Cu multilayers with low electrical resistivity (< $10\;{\mu}{\Omega}{\cdot}cm$) were achieved by the electrochemical flow reactor system than by the dual bath (Max. GMR = -4.2% and < $20\;{\mu}{\Omega}{\cdot}cm$) or the single bath (Max. GMR = -2.1% and < $90\;{\mu}{\Omega}{\cdot}cm$) techniques. Higher GMR effects have been obtained by producing smoother, contiguous layers at lower current densities and by the elimination of oxide film formation by conducting deposition under an inert gas environment. Our preliminary GMR measurements of Ni/Cu multilayers from the electrochemical flow reactor obtained at low magnetic field of 0.15 T, which may approach or exceed the highest reported results (-7% GMR) at magnetic fields > 5 kOe.

Astudy on the chromium plating from low concentrate bath (저농도 크롬도금에 관한 연구)

  • Lee, Kyung-Jin;Park, Kwang-Ja;Lee, Sung-Joo;Lee, Jong-Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.10 no.2
    • /
    • pp.1-18
    • /
    • 1977
  • In decorative chromium plating, highly concentrated conventionl baths ($CrO_3$ 150~400g/l) have been used. Because of the problems of heavy metal pollution and the saving of raw materials, chromium plating from dilute bath has been developed recently. The present study was performed to determine the effects of all the variables in the low concentrated chromium plating bath, such as brightness, appearence, current efficiency, and plating rate with regard to the bath composition and plating conditions.

  • PDF

Magnetic Properties of Electrodeposited Co-Ni-P Alloys (Co-Ni-P합금도금층의 자기적 성질에 관한 연구)

  • Paik, M. S.;Kim, Y. K.;Kang, T.;Sohn, H. J.
    • Journal of the Korean institute of surface engineering
    • /
    • v.24 no.2
    • /
    • pp.96-102
    • /
    • 1991
  • Co-Ni-P alloys were electrodeposited from NH4Cl-sulfate-hypophosphite baths under various plating conditions. Their effective anisotropic magnetic field which is one of the important properties for magnetic recording materials were investigated as the function of alloy compositions and c-axis orientation. The preferred orientation and the contents of Ni and P depend on the pH of solutions and also on the current density. It was found that the alloy films deposited from the solutions of pH4 at high current density had c-axis orientation parallel to the growth direction and the effective anisotropic fields sufficient for perpendicular magnetic recording application.

  • PDF

The Relationship between Bathing and Health Status (목욕행위와 건강상태와의 관계 - 도시지역에 거주하는 여성을 대상으로 -)

  • 최희정;이은옥
    • Journal of Korean Academy of Nursing
    • /
    • v.32 no.4
    • /
    • pp.519-528
    • /
    • 2002
  • The purpose of this study was to test the relationship between health status and bathing. Method: The population of this study consisted of females, above age 20 in urban areas in order to control the effects of extraneous variables, resident areas, gender, and age. Four hundred and twenty-eight (428) women were interviewed with a structured questionnaire. Medical Outcomes Study Short Form (SF)-36 Health Survey assessed individual health status. Bathingbehavior and attitudes toward bath have been measured with questionnaires designed by the authors. Result: The most popular bathing type was shower (46.8%). The preferred type of bath was related to health status. A common purpose of the tub-bath was relieving fatigue and hygiene, but the other purposes were different on the subjects health status. Persons with low health status took frequently tub-baths for health. Attitudes toward bath were related to health status. Women with low scores in physical health recognized more physical effects of bath than psychological effects or hygenic effects. Conclusion: Bathing included physical and psychological dimensions and was related to health status.

Effect of Electrodeposition Condition on GMR Co/Cu Multilayers

  • Rheem, Young-Woo;Yoo, Bong-Young
    • Journal of Magnetics
    • /
    • v.12 no.3
    • /
    • pp.124-128
    • /
    • 2007
  • Co/Cu GMR multilayers were electrodeposited from various electrolytes using the dual bath technique to achieve high sensitive GMR multilayers. GMR ratio and sensitivity were strongly influenced by solution compositions and electrodeposition parameters where GMR and sensitivity of 12% and 0.052%/Oe were achieved from pyrophosphate baths. The effect of plating conditions on properties of Co/Cu multilayers may be attributed to crystallinity and grain size of deposits, and the ability of plating solutions to deposit contiguous films at lower nano thicknesses.

Preferred Orientation, Microstructure, Surface Morphology and Mechanical Properties of Electrodeposited Copper Foils (電解銅薄의 優先方位, 斷面組織, 表面形態 및 機械的 性質)

  • Kim, Yoon-Keun;Lee, Dong-Nyung
    • Journal of the Korean institute of surface engineering
    • /
    • v.18 no.3
    • /
    • pp.95-104
    • /
    • 1985
  • A study has been made of preferred orientation, crose sectional microstructure, surface morphology and mechanical properties of copper foils fabricated by electrodeposition on 304 stainless steel plate from copper sulfate baths for high speed plating. The preferred orientation of the copper foils changed from the [110] to the [111] to ture with decreasing bath temperature and increasing cathode current density. The foils with the [110] texture had the field oriented texture type structure and the surface of many asperities grooved approximately perpendicular to the subtrate. A specimen with the [111]+[311] texture had the lower strength than one with the [10] texture, if they were obtained under similar electrolysis conditions.

  • PDF