• 제목/요약/키워드: Base plate

Search Result 614, Processing Time 0.022 seconds

A Study on Transferred Load Reduction on Paved Track Roadbed with Low Elastic Base Plate Pad (저탄성 베이스플레이트 패드 적용에 따른 포장궤도 노반에서의 전달하중 저감에 관한 연구)

  • Lee, Il-Wha;Kang, Yun-Suk;Lee, Hee-Up
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3D
    • /
    • pp.399-405
    • /
    • 2008
  • Development of the paved track is required as a low-maintenance of conventional line. The paved tracks are one of the types of the ballast reinforced tracks those are manufactured by adopting the prepacked concrete technique. The main elements of this tracks are large sleeper, low elastic pad, fastener, cement mortar, geotextile and recycled ballast. Low elastic pad is the most effective element of such tracks on the basis of stress-displacement characteristics, dynamic response and fatigue characteristics. The stiffness of the pad determine the stiffness of the track. Consequently, it is more important in case of concrete track structure such as paved track because application of low elastic pad seriously effect the durability and stability of the track. The main objective of this study is to confirm the reduction of train load, which transfer to roadbed through various pad effects. To achieve this task static, numerical analysis and real scale repeated loading test was performed while load reduction effect of low elastic pad was analyzed by using displacement, stress and strain ratio characteristics of the paved track.

EFFECT OF INSTRUMENT COMPLIANCE ON THE POLYMERIZATION SHRINKAGE STRESS MEASUREMENTS OF DENTAL RESIN COMPOSITES (측정장치의 compliance 유무가 복합레진의 중합수축음력의 측정에 미치는 영향)

  • Seo, Deog-Gyu;Min, Sun-Hong;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.145-153
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of instrument compliance on the polymerization shrinkage stress measurements of dental composites. The contraction strain and stress of composites during light curing were measured by a custom made stress-strain analyzer, which consisted of a displacement sensor, a cantilever load cell and a negative feedback mechanism. The instrument can measure the polymerization stress by two modes: with compliance mode in which the instrument compliance is allowed, or without compliance mode in which the instrument compliance is not allowed. A flowable (Filtek Flow: FF) and two universal hybrid (Z100: Z1 and Z250: Z2) composites were studied. A silane treated metal rod with a diameter of 3.0 mm was fixed at free end of the load cell, and other metal rod was fixed on the base plate. Composite of 1.0 mm thickness was placed between the two rods and light cured. The axial shrinkage strain and stress of the composite were recorded for 10 minutes during polymerization. and the tensile modulus of the materials was also determined with the instrument. The statistical analysis was conducted by ANOVA. paired t-test and Tukey's test (${\alpha}<0.05$). There were significant differences between the two measurement modes and among materials. With compliance mode, the contraction stress of FF was the highest: 3.11 (0.13). followed by Z1: 2.91 (0.10) and Z2: 1.94 (0.09) MPa. When the instrument compliance is not allowed, the contraction stress of Z1 was the highest: 17.08 (0.89), followed by FF: 10.11 (0.29) and Z2: 9.46 (1.63) MPa. The tensile modulus for Z1, Z2 and FF was 2.31 (0.18), 2.05 (0.20), 1.41 (0.11) GPa, respectively. With compliance mode. the measured stress correlated with the axial shrinkage strain of composite: while without compliance the elastic modulus of materials played a significant role in the stress measurement.

Effect of Aging at Low Temperature on Storage Stability of Seasoned Pork (저온 숙성이 양념돈육의 저장 안정성에 미치는 영향)

  • Hah Kyoung-Hee;Ahn Chong-Nam;Joo Seon-Tea;Park Gu-Boo;Park Ki-Hoon;Kim Il-Suk;Jin Sang-Keun
    • Food Science of Animal Resources
    • /
    • v.26 no.1
    • /
    • pp.85-91
    • /
    • 2006
  • This study was investigated the effect of aging at low temperature of seasoned pork with Korean traditional sauces. The samples, pork loins were cut by the shape of cube ($5{\times}15{\times}5\;cm$) and porks were seasoned with Korean tradition sauce such as soy sauce base (T1), red pepper sauce base (T2), and soybean sauce base (T3) in the same proportion of meat seasonings, respectively. The seasoned samples were stored, at $1{\pm}1^{\circ}C$ during 28 days. Surface meat color of seasoned pork was affected by the kind of sauces. Lightness of seasoned pork with soy sauce was decreased with increased in periods while red pepper sauce made it more red and soybean sauce produced a light seasoned pork, Lightness of inner meat color of seasoned pork was decreased with increased aging periods, and seasoned pork with soy sauce was lower compared to other treatments. TBARS of seasoned pork with soy sauce was lower compared to other treatments, and increased TBARS in all treatments with aging period. Total plate counts were increased with aging period, and those of seasoned pork with soy sauce were lower compared to other treatments. The microbial counts of Escherichia coli levels in all treatments was higher at the first day of aging periods. However Escherichia coli levels were decreased with increasing the aging period. Lactobacilli spp. of seasoned pork with soy sauce was not increased during aging periods, whereas other treatments were increased with aging period increased.

Surface roughness and $Candida$ $albicans$ adhesion to flexible denture base according to various polishing methods (연마방법에 따른 탄성의치의 표면거칠기와 $Candida$ $albicans$의 부착율 변화)

  • Oh, Ju-Won;Seo, Jae-Min;Ahn, Seung-Keun;Park, Ju-Mi;Kang, Cheol-Kyun;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.106-111
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the effect of 3 chairside polishing methods and laboratory polishing methods on surface roughness and $C.$ $albicans$ adhesion of polyamide denture base. Materials and methods: Using contact profilometer, the surface of polyamide specimens ($25{\times}15{\times}2mm$) was studied after conventional polishing without finishing and after chiarside polishing with 2 chiarside polishing kits and chairside-pumice polishing following finishing with tungsten carbide bur. To evaluate the adhesion of $C.$ $albicans$, $C.$ $albicans$ suspension was overlayed on the test specimen. And the specimens were incubated for 2 hours. Imprint culture method was achieved and counted the colony on the agar plate. Polished polyamide were evaluated using a scanning electron microscope. The statistics were conducted using one-way ANOVA and in case of difference, Scheffe test and Tamhane's T2 test were used. Results: Surface roughness (Ra) of surfaces polished with 2 chairside polishing kits had higher than conventional polishing and pumice polishing. The highest roughness value was $0.32{\pm}0.10{\mu}m$, and the lowest was $0.02{\pm}0.00{\mu}m$. The adhesion of $C.$ $albicans$ on the specimens polished with chairside polishing group and pumice polishing group were increased than conventional polishing group ($P$<.01). Conclusion: Conventional laboratory polishing was found to produce the smoothest surface and the lowest adhesion of $C.$ $albicans$. Two groups polished with Chairside polishing kits were similar with respect to surface roughness. Surface of the specimen polished with pumice is significantly smoother than 2 chairside polishing groups, but the result of $C.$ $albicans$ adhesion is that group polished with pumice was similar with 2 chairside polishing groups ($P$>.01).

An Experimental and Analytical Studies on the Mechanical Behavior of High Tension Bolted Joints with Oversize Hole (과대공을 갖는 고장력 볼트 이음부의 역학적 거동에 관한 실험 및 해석적 연구)

  • Lee, Seung Yong;Park, Young Hoon;Cho, Sun Kyu;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.3 s.36
    • /
    • pp.355-367
    • /
    • 1998
  • To evaluate the mechanical behavior and the compressive stress distribution in high tension bolted joints according to the size of bolt hole, the experimental and analytical studies are performed with enlarging bolt hole size. In experimental study, the static test is performed to measure the slip coefficient, and the fatigue test is also performed to evaluate the fatigue strength and failure pattern of fatigue crack. In analytical study, the compressive stress distribution is investigated by using the finite element analysis. From the result of experimental study, the slip coefficient and fatigue strength of the high tension bolted joints with oversize hole are not much different but somewhat it has decreased. These are because the size of bolt hole is larger than the holes of nominal size, therefore the width of clamping force is decreased and the compressive stress distribution area is smaller, this is certificated in the finite element analysis. In addition, the origin of fatigue crack in the oversize holes is closer to the hole than in the holes of nominal size, consequently it is investigated that the origin of fatigue crack is intimately associated with the compressive stress distribution which is formulated by the clamping force in both base metal and splice plate.

  • PDF

Analysis of the Organochlorine Pesticides in the Water and Soil (물 및 토양 중 유기염소계 농약의 분석)

  • 김정호
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1315-1320
    • /
    • 2003
  • To obtain the residual organochlorine pesticides in the coastal environment, the methods of analysis for BHC's isomer, Kelthane, Orthocide and Endrin by GC-ECD are surveyed. The relative retention time for ${\alpha}$-BHC, ${\beta}$-BHC, (equation omitted)-BHC and $\delta$-BHC is 1.00, 1.18, 1.24, 1.31 and it's of Kelthane, Orthocide, Endrin is 1.56, 1.70, and 2.02, respectively. The BHC isomers Kelthane, Orthocide and Endrin are separated on the base line. The plate height(H) for ${\alpha}$-BHC, ${\beta}$-BHC, (equction omitted)-BHC and $\delta$-BHC is 50mm, 35mm, 32mm and 29mm, and it's of Kelthane, Orthocide, Endrin is 81mm, 68mm and 48mm, respectively. The qualified defection concentration for ${\alpha}$-BHC, ${\beta}$-BHC, (equation omitted)-BHC and $\delta$-BHC is 0.26, 0.36, 0.37 and 0.39ng/g and it's of Kelthane, Orthocide, Endrin is 0.55, 1.39 and 0.56ng/g, respectively, BHC's isomer, Kelthane, Orthocide and Endrin are not detected in soil environment on South Cheju Island. Also residual organochlorine pesticides are not detected in the sea water and sediment in the ocean environment.

Inactivation of Candida albicans Biofilm by Radachlorin-Mediated Photodynamic Therapy (라다클로린으로 매개된 광역학치료에 의한 백색 캔디다 바이오필름의 비활성)

  • Kwon, Pil Seung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.4
    • /
    • pp.273-278
    • /
    • 2015
  • The purpose of this study was to evaluate the in-vitro efficacy of PDT using red light emitting diode (LED) with Radachlorin for biofilm inhibition of clinical Candida albicans isolates. The suspensions containing C. albicans at $9{\times}10^8CFU/mL$ were prepared on yeast nitrogen base containing 5% glucose. The biofilm formation was grown for 3 h after seeding suspensions each 100 ul on a 96-well plate and then supernatant was discarded. Each well was treated with $0.39{\mu}g/mL$ from $50{\mu}g/mL$ concentrations of Radachlorin on adherent biofilm. After a 30-minute incubation, light was irradiated for 30, 60, or 90 minutes using the following light source of wavelength 630 nm LED, at energy densities of 14, 29, and $43J/cm^2$. Afterwards, all supernatant was removed and dried. Adherent cells were stained with safranin O and dried. The cell viability was measured using a microplate reader at 490 nm. Also, a fluorescent signal on C. albicans was observed by saturation of a photosensitizer. In conclusion, a significant inhibition of 72.5% was observed to C. albicans on biofilm at the Radachlorin dose of $50{\mu}g/mL$ with 630 nm LED. The Photosensitizer (Radachlorin) was adequate at 30 minuttes for C. albicans. Overall, the results showed that inhibition of biofilm formation was Radachlorine dose-dependent. The results suggest that PDT, using Radachlorin with 630 nm LED, is able to decrease biofilm formation of C. albicans.

Light and Scanning Electron Microscopy of Tetragomphius procyonis (Ancylostomatoidea) from Wild Badger (한국산 야생 오소리에서 분리한 오소리구충 (Tetragomphius procyonis)의 광학 및 주사전자현미경 소견)

  • Son, Hwa-Young;Oh, Yoon-Hee;Kim, Hyeon-Cheol;Park, Bae-Keun
    • Journal of Veterinary Clinics
    • /
    • v.26 no.4
    • /
    • pp.379-385
    • /
    • 2009
  • Tetragomphius procyonis Baylis & Daubney, 1923 were obtained from the pancreatic duct of a naturally infected Eurasian badger, Meles meles, which was submitted to animal hospital for parasitic diagnosis from Gyeryongsan National Park in Korea. The hookworms were examined by light and scanning electron microscope. The length of body measured male 15.0-18.8 mm, female 21.5-25.5 mm, respectively. In both sex, the ventral cutting plates of oral margin are much reduced and elongated latero-dorsally, the dorsal cutting plate is located long follow doral margin of the oral opening. The buccal capsule is cup-shaped and thicken with four cusped tooth at its base. The copulatory bursa has elongated ventral lobes and their large rays are parallel, while the dorsal lobe with its supporting rays is slightly split in two. The slender spicules are filariform and very long (8.7-9.3 mm), and their tips are fused together. The hookworm has following characters: dorsal cone on the both sex, gubernaculum on the male and terminal spine on the female tail absent; vulva is opening in the juction of the fourths and fifths of the body; dorsal ray with two long stems. The eggs from the uterus are 16 cell stages and those from the rectal feces, 32 cell stages. The size of eggs is 77.48-83.45 ${\times}$ 50.75-63.38 ${\mu}m$.

Microanatomy of Philtral ridge (인중의 미세해부학적 고찰)

  • Lee, Jong-Ho;Jeon, Se-Il;Myung, Hoon;Lim, Koo-Young;Seo, Byung-Moo;Choi, Jin-Young;Choung, Pill-Hoon;Kim, Myung-Jin;Hong, Sam-Pyo;Lee, Jae-Il;Lim, Chang-Yun
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.3 no.1
    • /
    • pp.11-16
    • /
    • 2000
  • Many efforts are made to achieve satisfactory cosmetic and functional result in the repair of cleft lip. However, repair may be complicated in many cases by distortion of the vermilion border, obliteration of the normal contour of the philtrum, and eclabium in spite of many methods used in these days. To achieve better results in cleft lip repair, thorough understandings of the relationship between the surface morphology of the upper and lower lip and the underlying musculature is necessary but reports about this topic is rare. So, our studies were performed on the full-thickness upper lips containing both philtral ridge up to columelar base and lower lip, 4 post-mortem specimens of 2 females and 2 males aged from 16 to 42, using serial histological sections taken in the transverse and vertical planes under light microscopy. Thorough understanding of the anatomical relationships is established and on the basis of our findings, we can postulate some criteria to create a normal and natural philtrum in a patient with a cleft lip, it would be necessary to restore the normal deep muscle attachments and superficial dermal attachments of the orbicularis muscle, to close the lip without tension, to restore thickness of the philtral ridge, and to minimise nonelastic scar tissue.

  • PDF

Flexural Tensile Strength of CJP Groove Welded Joints Connecting Thick HSA800 Plates (HSA800 후판재의 완전용입 맞댐용접부 휨-인장강도 실험)

  • Lee, Cheol Ho;Kim, Dae Kyung;Han, Kyu Hong;Park, Chang Hee;Kim, Jin Ho;Lee, Seung Eun;Kim, Do Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.407-418
    • /
    • 2014
  • As a continuing work of previously conducted standard tension tests, full-scale flexural tests were conducted in this study to assess the structural performance the CJP groove welded joints connecting thick HSA800 plates. Two welding electrodes were available at the time of this experimental research; one was GMAW-based electrode A and the other FCAW-based electrode B. Three full-scale box-type beam specimens with single bevel- and V-groove CJP welded joints were fabricated from 60mm and 25mm thick HSA800 plates according to the AWS-prequalified groove welded joint details. In designing the specimens, all possible limit states like local and lateral torsional buckling were carefully controlled in order to induce flexural plastic yielding or eventual joint fracture. All the CJP joints made by both welding electrodes showed satisfactory performance and were able to transfer the tensile flange forces higher than that corresponding to the measured tensile strength of HSA800 flange plates. However, it should be noted that, during fabrication, serious concerns about the welding efficiency and workability of the GMAW-based electrode were raised by a certified welder. The fracture occurred at the unbeveled (or vertical) interface between the weldment and the base metal when the GMAW-based electrode was used in the single-bevel joint, implying the possibility of insufficient melting. Thus, the FCAW-based electrode B is again recommended as the choice of welding electrode for HSA800 plates. The limited test data of this study implies that the V-groove CJP joint should be used in favor of the single bevel CJP joint, if possible.