• Title/Summary/Keyword: Bare Cell

Search Result 70, Processing Time 0.024 seconds

The Study on Thermal Shock Test Characteristics of Solar Cell for Long-term Reliability Test (장기 신뢰성 평가를 위한 태양전지의 열충격 시험 특성에 관한 연구)

  • Kang, Min-Soo;Kim, Do-Seok;Jeon, Yu-Jae;Shin, Young-Eui
    • Journal of Energy Engineering
    • /
    • v.21 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • This study has been performed Thermal Shock test for analyze the cause of Power drop in PV(Photovoltaic) Module. Thermal Shock test condition was performed with temperature range from $-40^{\circ}C{\sim}85^{\circ}C$. One cycle time is 30min. which are consist of low and high temperature 15min. each other. The test was performed with total 500cycles. EL, I-V were conducted every 100cycle up to 500cycles. Mono Cell resulted in 8% Power drop rates in Bare Cell and 9% in Solar Cell. In the case of Multi Cell resulted in 6% Power drop rates in Bare Cell and 13% in Solar Cell. After Thermal Shock test, Solar Cell's Power drop resulted from surface damages, but in the case of Bare Cell's Power drop had no surface damages. Therefore, Bare Cell's Power drop was confirmed as according to leakage current increase by analysis of Fill Factor after Thermal Shock test. Also, Solar Cell's Power drop rates are higher than that of Bare Cell because of surface damages and consuming electric power increase. From now on, it should be considered that analyzed the reasons of Fill Factor decrease and irregular Power drop in PV module and Cell level using cross section, various conditions and test methods.

Research on the Power Drop of Photovoltaic Module’s Aging Through the Thermal Shock Test

  • Kang, MinSoo;Jeon, YuJae;Kim, DoSeok;Shin, YoungEui
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.5
    • /
    • pp.268-273
    • /
    • 2015
  • While analyzing the specimens before and after the thermal shock test, we found that the power drop rate of the bare cell was 5.08%, while the power drop rate of the ribboned cell was 16.49%. In comparative terms, the efficiency was lower at the ribboned cell than at the bare cell. While analyzing through EL (Electroluminescence) shots and cross sections, we tried to decipher the exact cause of the power drop. Although mere color change of the cell was observed at the surface of the bare cell, no abnormality could be found inside the cell. On the surface of the ribboned cell, the short circuit of gridfinger extended from the front part of the front electrode of the ribboned cells. Therefore, cracks occurred on the surface of the cell. Cracks also appeared inside the cell. While analyzing the I-V curve, we determined an increase in the leakage current and an increase of resistances in series in the bare cell. In the ribboned cell, the resistances in parallel reduced remarkably. An increase of resistances in series could also be verified. Conclusively, we deduced that the power drop rate in the bare cell is a life span of the cell itself; aging is the cause of power drop rate in cells. In case of ribboned cell, the power drop rate was directly influenced by internal cracks and an intermetallic compound layer joining the ribbon at the front electrode.

Solar Module with a Glass Surface of AG (Anti-Glare) Structure (연요철(Anti-Glare) 구조의 표면 유리 기판을 가지는 고효율 태양전지 모듈)

  • Kong, Dae-Young;Kim, Dong-Hyun;Yun, Sung-Ho;Bae, Young-Ho;Yu, In-Sik;Cho, Chan-Seob;Lee, Jong-Hyun
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.3
    • /
    • pp.233-241
    • /
    • 2011
  • Currently, solar module is using the two methods such as a glass-filled method or a super-straight method. The common point of these methods is to use glass structure on the front of solar module. However, the reflectance of the solar module is high depending on the height of the incident sunlight due to the flat surface of the module front glass. Purposed to solve these problems, AG (anti-glare) structures were formed on the glass surface. Next is fabrication methods of AG structure. First, uneven structure made by micro blaster equipment was dipped in Hydro-fluidic acid (HF) acid. HF acid process was carried out to remove particles and to make high transmittance. The reflectance and transmittance of the anti-glare glass was compared to those of the bare glass. The reflectance of anti-glare glass decreased approximately 1% compared with bare glass. The transmittance of anti-glare glass was similar to bare glass. According to the sample angle, the difference of the reflectance between bare glass and the anti-glare glass was about 19%. Isc and efficiency value of anti-glare glass on bare solar cell appeared about 3.01 mA and 0.228% difference compared with bare glass. Anti-glare glass on textured solar cell appeared about 9.46 mA and 0.741% difference compared with bare glass. As a result, the role of anti-glare in the substrate is to reduces the loss of sunlight reflected from the surface. In this study, therefore, AG structure on the solar cell was used to improve the efficiency of solar cell.

Reduction of Methanol Crossover in a Direct Methanol Fuel Cell by Using the Pt-Coated Electrolyte Membrane

  • Jung, Eun-Mi;Rhee, Young-Woo;Peck, Dong-Hyun;Lee, Byoung-Rok;Kim, Sang-Kyung;Jung, Doo-Hwan
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • A Pt-layer was deposited on the anode side of a Nafion membrane via a sputtering method in order to reduce methanol crossover in a direct methanol fuel cell (DMFC). The methanol permeation and the proton conductivity through the modified membranes were investigated. The performances of the direct methanol fuel cell were also tested using single cells with a Nafion membrane and the modified membranes. The Pt-layers on the membrane blocked both methanol crossover and proton transport through the membranes. Methanol permeability and proton conductivity decreased with an increase of the platinum layer thickness. At methanol concentration of 2 M, the DMFC employing the modified membrane with a platinum layer of 66 nm-thickness showed similar performance to that of a DMFC with a bare Nafion membrane in spite of the lower proton conductivity of the former. The maximum power density of the cell using the modified membrane with a platinum layer of 66 nm-thickness increased slightly while that of the cell with the bare membrane decreased abruptly when a methanol solution of 6M was supplied.

A Development of Device for Measurement of Vertical Ground Reaction Force(II) (수직 반작용력 측정 장치 개발(II))

  • Park, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.341-354
    • /
    • 2003
  • The purpose of this study was to develop the uniaxial force plate system which is measured by the vertical force. The VGRF(vertical ground reaction force) 1.0 was composed of 2 bath digital scales, 2 indicaters, and analyzing software. This system was newly renovated to VGRF 2,0 which are 2 industrial digital scales, 2 adjustable indicators, and enforced analyzing software. Changes of the new system were as follows. First, the height of the plate was 75% lower than before. Second, sensing ability of the load cell was changed from 90 - 0.05kg to 300 - 0.1kg. Third, the speed of data processing was changed from 17 per second to 60 per second. Fourth, analyzing software was enforced to develop and calculate the data. For the test of the system, two different types(bare foot, high-heeled shoes) gait was adopted. highly skilled female walker(23yrs, height 165cm, body mass 46.8kg) participated for the experimental study. During the dynamic performance(gait analysis), the data of each load cell were very similar to the previous studies. Specifically, bare foot walking had less vertical force than high-heeled shoes. Consequently, VGRF 2.0 can sense the general dynamic movements as well as static load conditions.

A Study on Ozone Micro Bubble Effects for Solar Cell Wafer Cleaning (신개념 태양전지 세정용 오존마이크로 버블에 관한 연구)

  • Yoon, Jong-Kuk;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.94-98
    • /
    • 2012
  • The behavior of ozone micro bubble cleaning system was investigated to evaluate the solution as a new method of solar cell wafer cleaning in comparison with former conventional RCA cleaning. We have developed the ozone dissolution system in the ozonated water for more efficient cleaning conditions. The optimized cleaning conditions for solar cell wafer process were 10 ppm of ozone concentration and 12 minutes in cleaning periods, respectively. We have confirmed the cleaning reliability and cell efficiencies after ozone micro bubble cleaning. Using this new cleaning technology, it was possible to obtain higher efficiency, higher productivity, and fast tact time for applying cleaning in the fields on bare ingot wafer, LED wafers as well as the solar cell wafer.

Numerical Prediction of Turbulent Flow in Bare Rod Bundles Using Control Volume Based Finite Element Method

  • Im, In-Young;Cheong, Jong-Sik
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.480-486
    • /
    • 1995
  • Turbulent flow field in a subchannel of bare rod bundles has been numerically simulated using the control volume based finite element method. Launder & Ying model of Reynolds stress and Lam & Bremhorst low-Reynolds number model are implemented in k-$\varepsilon$ equations and momentum equations. Secondary flows are simulated using the stream function and vorticity approach. The control volume based finite element method enable to use the upwind scheme (donor cell scheme). Sensitivity of the constants in the models are studied, and proper values are found to get the close result to the measured flow distributions.

  • PDF

Effect of Pretreatments on Graphene Coated Bipolar Plate of PEMFC on Electrochemical (전처리가 그래핀을 코팅한 고체고분자 연료전지 분리판의 전기화학적 특성에 미치는 영향)

  • Cha, Seong-Yun;Lee, Jae-Bong
    • Corrosion Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.224-232
    • /
    • 2014
  • Effect of pretreatments on the graphene coated bipolar plate of proton exchange membrane fuel cell(PEMFC) was investigated in simulated environments for PEMFC by using electrochemical measurement techniques. Interfacial contact resistance(ICR) between the graphene coated bipolar plate and the gas diffusion layer(GDL) was measured. The value of ICR decreased with an increase in compaction stress($20N/cm^2{\sim}220N/cm^2$). ICR of graphene coated bipolar plate was higher than that of bare 316L stainless steel. However, Potentiodynamic measurement results showed that the corrosion resistance of graphene coated bipolar plate was higher than that of bare 316L stainless steel. $H_2SO_4$ acid pretreatment was the most effective among various pretreatments. The lowest ICR and the corrosion current density were obtained when using $H_2SO_4$ solution pretreatment.

Electrochemical Properties of NiO-YSZ Thin Films on 316 Stainless Steel Bipolar Plates Under a Simulated PEMFC Environment

  • Lee, W.G.;Jang, H.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.1177-1182
    • /
    • 2012
  • The corrosion resistance of 316L stainless steel coated with NiO-YSZ (Ni added yttria stabilized zirconia) was examined in a proton exchange membrane fuel cell (PEMFC) environment. The NiO-YSZ coating was carried out using a sol-gel dip coating method, and the corrosion resistance and interfacial contact resistance (ICR) were determined by the composition and morphology of the NiO-YSZ film. The corrosion resistance increased with increasing Ni content in the NiO-YSZ film, but rapid corrosion was observed when the YSZ film contained more than 15 wt % Ni due to surface cracks. The polarization resistance was improved by several orders of magnitude when 316L stainless steel was coated with a 15 wt % NiO-YSZ film compared to bare 316L. The ICR of the NiO-YSZ film was decreased to that of bare 316L when the YSZ film contained 25 wt % NiO, suggesting the possible application of NiO-YSZ coated stainless steel for a bipolar plate.

Cellular Adhesion and Growth on the Vertically Aligned Silicon Nanowire Arrays

  • Yun, Seo-Yeong;Park, Lee-Seul;Lee, Jin-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.266.2-266.2
    • /
    • 2013
  • According to advanced nanotechnology, the nanostructured materials with various kinds and shape are synthesized easily or produced by process. Recently, researches about interaction between the nanostructured materials and biological system have been progressed actively. The surface topography may influence cellular responses, for example cell adhesion, cell morphology. In this work, we synthesized vertically aligned silicon nanowires (SiNWs) on the Au-covered Si(111) wafer by chemical vapor deposition (CVD) method. We accomplished to control of the SiNWs diameter by regulating thickness of Au film such as 1 nm and 10 nm. These substrates did not isolate cells and just provided surface topography for cell culture. Human Embryonic Kidney 293T cells (HEK 293T cells) were cultured on these substrates for 2 days. We studied the nanotopographical effects on cell morphology, adhesion, and growth which are evaluated on each SiNWs substrate comparing bare glass as control.

  • PDF