• Title/Summary/Keyword: Band fault model

Search Result 4, Processing Time 0.019 seconds

Band Fault Modelling Based on specification for the Time Domain Test of RFIC (RF 집적회로의 시간영역 테스팅을 위한 사양기반 구간고장모델링)

  • Kim, Kang-Chul;Han, Seok-Bung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.2
    • /
    • pp.299-308
    • /
    • 2008
  • This paper proposes a new design specification-based band fault modelling technique that can test design specification in a time domain. The band fault model is defined and the conditions of band fault model are gained as normal operation regions are defined. And the conditions of band fault model are used in a 5.25GHz low noise amplifier, then 9 band fault models that can detect hard and parametric faults of active and passive devices are obtained.

The time domain testing technique of RFIC based on specifications (설계사양기반 RF 집적회로의 시간영역 테스팅 기법)

  • Han Seok-Bung;Baek Han-Suk;Kim Kang-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.5 s.347
    • /
    • pp.34-47
    • /
    • 2006
  • In this paper, a new testing technique for core components of wireless transceiver was proposed. That was, band fault models (including the information of specifications in the analogue and RF IC) and methods which can test specifications in the time domain easily by observing a variation of band fault models in the circuit output were proposed and developed. This technique had an advantage over testing technique in frequency domain because it didn't need expensive test equipments and could reduce the time required. Test technique proposed in this paper was adapted to the test of 5.25 GHz low noise amplifier and proved that this testing technique was efficient in RF IC including low noise amplifier.

The Study of Predictive Diagnosis Technology Development Status and Promotion Plan for Reactor Coolant Pump (원자로냉각재펌프 예측진단 기술개발 현황 및 추진방안)

  • Hee Chan Kim
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.1
    • /
    • pp.44-51
    • /
    • 2023
  • The RCP is one of the main components in nuclear power plants and plays an important role in circulating coolant to the RCS system. Currently, nuclear plants are monitored using various monitoring systems. However, since they operate independently according to their functional purpose, it is not able to analyze vibration and operation/performance information comprehensively, and thus failure diagnosis accuracy is limited. In addition, these systems do not provide some important information (such as fault type, parts and cause) necessary for emergency actions, but provide only alarm information. To improve these technical problems, this study proposes a diagnosis technique (M/L, Rule-based model, Data-driven model, Narrow band model) and methodology for comprehensive analysis.

UHF Electromagnetic Perturbation due to the fluctuation of Conductivity in a Fault Zone (단층대의 전기전도도 변동에 의한 UHF 전자기장 교란)

  • Lee Choon-Ki;Lee Heuisoon;Kwon Byung-Doo;Oh SeokHoon;Lee Duk Kee
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.2
    • /
    • pp.87-94
    • /
    • 2003
  • ULF geomagnetic field anomalies related to earthquakes have been reported and a mechnism that magnetic field variations could be generated by the induced telluric current due to the high frequency fluctuation of conductivity in a fault Bone have been proposed. In this study, we calculated electromagnetic anomalies using a simple fault model and investigated the possibility of significant perturbation. Since low frequency electromagnetic fields are modulated by the high frequency oscillation of conductivity and the modulated fields are concentrated in a narrow ULF band, the electromagnetic fields in ULF band could be perturbed significantly. The amplitude of electromagnetic field anomaly depends on various factors: the geometry and conductivity of fault zone, the magnitude and frequency of conductivity fluctuation, the resistivity structure of crust or mantle, the frequency bandwidth of observational data and so on. Therefore, it is strongly required to reveal the deep resistivity structure of crust a.: well ah the structure of fault zone and to ,select the optimal observation frequency band for the observation of electromagnetic activities related with earthquakes.