• 제목/요약/키워드: Balanced operation

검색결과 267건 처리시간 0.025초

Three-Level SEPIC with Improved Efficiency and Balanced Capacitor Voltages

  • Choi, Woo-Young;Lee, Seung-Jae
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.447-454
    • /
    • 2016
  • A single-ended primary-inductor converter (SEPIC) features low input current ripple and output voltage up/down capability. However, the switching devices in a two-level SEPIC suffer from high voltage stresses and switching losses. To cope with this drawback, this study proposes a three-level SEPIC that uses a low voltage-rated switch and thus achieves better switching performance compared with the two-level SEPIC. The three-level SEPIC can reduce switch voltage stresses and switching losses. The converter operation and control method are described in this work. The experimental results for a 500 W prototype converter are also discussed. Experimental results show that unlike the two-level SEPIC, the three-level SEPIC achieves improved power efficiency with balanced capacitor voltages.

전력계통의 중성선에 적용된 초전도한류기의 대칭고장전류 저감방안 분석 (Analysis on Reduction Method of Symmetrical Fault Current in a Power System with a SFCL applied into Neutral Line)

  • 임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제23권2호
    • /
    • pp.148-152
    • /
    • 2010
  • The superconducting fault current limiter (SFCL) applied into the neural line of a power system, which can limit the unsymmetrical fault current from the single-line ground fault or the double-line ground fault, was reported to be the effective application location of the SFCL in a power system. However, the limiting operation for the symmetrical fault current like the triple line-ground fault is not effective because of properties of the balanced three-phase system. In this paper, the limiting method of the symmetrical fault current in a power system with a SFCL applied into neutral line was suggested. Through the short-circuit experiments of the three-phase fault types for the suggested method, the fault current limiting and recovery characteristics of the SFCL in the neutral line were analyzed and the effectiveness of the suggested method was described.

공정한 MAC 프로토콜을 위해 순환서비스시스템을 적용한 평형 DQDB (Balanced DQDB Applying the System with Cyclic Service for a Fair MAC Procotol)

  • 류희삼;강준길
    • 한국통신학회논문지
    • /
    • 제18권12호
    • /
    • pp.1919-1927
    • /
    • 1993
  • 본 논문은 표준 DQDB에서 문제가 되고 있는 불공정성 문제를 경감한 새로운 MAC프로토콜을 제안하고 분석하였다. DQDB MAC프로토콜은 처리율, 메시지 지연 등에서 불공정한 면이 있으며, 대역폭은 슬롯재사용 혹은 파일의 긴 전송 동안 더욱 불균등하게 배분될 수 있다. 본 연구에서 제안한 새로운 프로토콜을 평형(Balanced) DQDB 프로토콜이라 부르기도 하며, 이 새로운 엑세스 프로토콜은 이중 비스 네트워크 프로토콜의 한 비트를 이용하여 대역폭 분할에 공정성 보장 및 DQDB의 모든 특징을 유지한다. 또한, 슬로의 순차적 균등 배분을 해석하기 위하여 Wen Jing 등이 제시한 DQDB분석 모델을 고려하였다. 즉 한 버스상에서 비지 비트의 발생 확률을 예측하고, 마코프 체인을 사용하여 제안한 프로토콜에서의 처리율과 전송 확율에 대하겨 연구하였다. 그리고 시뮬레이션을 통하여 각 노드에서 RQ나 CD계수기가 동적으로 변화하는 상태에서 평형 DQDB와 표준 DQDB, BWB 구조를 비교하였다. 그 결과, 평형 DQDB가 동상위 노드에서에서 처리율이 감소하지만, 전체 노드의 약 70~80% 정도가 처리율 0.9 이상으로 나타났으며, 이러한 특징들은 수치적 분석 모델과 유사한 결과를 나타냄을 확인하였다.

  • PDF

CRLH 전송 선로 리키 웨이브 안테나를 이용한 평형 믹서 (Balanced Mixer Based on Composite Right/Left-Handed Transmission Line Leaky-Wave Antenna)

  • 김영
    • 한국전자파학회논문지
    • /
    • 제19권9호
    • /
    • pp.985-991
    • /
    • 2008
  • 본 논문은 차동과 공통 모드로 동작하는 메타 재질 구조를 바탕으로 평형 믹서 수신기를 제안한 것이다. 이 메타 재질 구조는 리키 웨이브 안테나로 동작하며, 순수 공통 모드는 억압한다. 이러한 특성은 낮은 LO 누설전력과 높은 RF-LO 고립도를 갖고 있어 LO과 RF 경로에 추가적인 여파기가 필요로 하지 않는다. 이 메타 재질은 차동 모드 동작에서는 Composite Right/Left-Handed(CRLH) 메타 재질처럼 동작하고, 공통 모드에서는 차단되는 성질을 갖는 단위 셀을 기초로 설계하였다. 제안된 메타 재질의 차동과 공통 모드 특성은 실험 결과를 통하여 증명하였다. 메타 재질을 이용한 수신기는 $1.96{\sim}2.40$ GHz의 주파수 범위에서 동작하는 안테나와 평형 믹서를 집적화시켜 제작하였고, 2.4 GHz에서 21.1 dB의 믹서의 변환 손실을 얻었다.

무선 센서 네트워크에서 에너지 효율적 패킷 전송을 위한 부하 균형 클러스터링 모델 (A Load Balanced Clustering Model for Energy Efficient Packet Transmission in Wireless Sensor Networks)

  • 이재희;김병기;강승호
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제4권12호
    • /
    • pp.409-414
    • /
    • 2015
  • 제한된 에너지 자원으로 동작하는 무선 센서 네트워크에서는 에너지 소비를 최소화하여 통신하는 방법이 중요한 연구 주제이다. 클러스터 헤드를 가진 구분되는 클러스터 안에 센서 노드를 그룹으로 묶는 클러스터링은 에너지 절약에 가장 효과적인 기술로 알려져 있다. 그러나 클러스터 기반 무선 센서 네트워크에서 클러스터 헤드나 게이트웨이는 수집된 정보를 싱크로 보내는 역할 등을 수행하기 때문에 더 많은 에너지를 소비하게 된다. 부적절한 클러스터의 구성은 게이트웨이에 오버로드를 가중시켜 전체 네트워크의 성능을 저하시킨다. 본 논문에서는 에너지 효율을 높이고 네트워크 수명을 향상시키기 위하여 새로운 부하 균형 클러스터링 모델을 제시하고 이를 분기한정 알고리즘과 다중시작 지역탐색 알고리즘을 설계하여 기존에 제시된 부하 균형 클러스터링 모델과 비교한 후 성능 측정 실험 후 결과를 제시한다.

기준전류추정형 인버어터에 의한 2 권선전동기의 2 상운전특성 (Characteristics of Two Phase Operation of Two Winding Motor Driven by Reference Current Adaptive Inverter)

  • 원종수;정의상
    • 대한전기학회논문지
    • /
    • 제33권8호
    • /
    • pp.289-298
    • /
    • 1984
  • The single phase induction motor is recently requested to meet a broad speed control and smooth forward and reverse operation due to the multifarious usages. This paper deals with two phase operation of a two winding motor by reference current adaptive inverter which can supply the currents to satisfy the balanced oeration into the main and auxiliary winding through the entire operational region. According to the roposed system, the starting, forward and reverse and variable speed control of a two winding motor eliminated the capacitor from the capacitor-run motor is also possible. The formation and its principle of the reference current adaptive inverter and characteristic analysis of the motor fed by this apparatus are described in this paper. Excellent agreement with the measured results and calculated values by computer simulation is obtained.

  • PDF

고조파 성분이 포함된 전압 불평형 운전시 유도전동기의 동작 특성 해석 (Analysis on the Operation Characteristics of Induction Motor Operated by Unbalanced Voltage with Harmonics Components)

  • 김종겸;박영진;이은웅
    • 전기학회논문지P
    • /
    • 제54권3호
    • /
    • pp.134-140
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are usually balanced and connected to three power systems. However, in the user power distribution systems, partial loads are single & three phase and unbalanced, generating voltage unbalance by the impedance mismatching. Voltage unbalance has detrimental effects on three-phase induction motors, including over heating, line-current unbalance, derating, torque pulsation, low efficiency, etc. This paper presents a scheme on operation states of a three-phase induction motor under the unbalanced voltages with harmonics components. Three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting not only fundamental but also harmonics components. Harmonic components at the voltage unbalanced factor(VUF) of the three-phase source voltages can then be examined the different values of VUF on machine's operation characteristics.

A design of a floating point unit with 3 stages for a 3D graphics shader engine

  • Lee, Kwang-Yeob
    • 전기전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.358-363
    • /
    • 2007
  • This paper presents a floating point unit(FPU) with 3 stages for a 3D graphics shader engine. It targeted to accelerate 3D graphics in portable device environments. In order to design a balanced architecture for a shader engine, we analyzed shader assembly instructions and estimated the performance of FPU with the method we propose. The proposed unit handles 4-dimensional data through separated two paths that are lead to general operation module and special function module. The proposed FPU is compiled as a form of the cascade FPU with 3 stages to efficiently handle a matrix operation with relatively low hardware overhead. Except some complex instructions that are executed using macro instructions, all instructions complete an operation in a single instruction cycle at 100MHz frequency. A special function module performs all operations in a single clock cycle using the Newton Raphson method with the look-up table.

  • PDF

불평형 전압 운전시의 역률보상용 커패시터 특성 연구 (A Study on the Characteristics for Power Capacitor under the Voltage Unbalance Operation)

  • 김일중;김종겸
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.36-40
    • /
    • 2008
  • Most of the low-voltage feeder are designed with approximately balanced and connected at the three phase four wire systems. However, Most of the power distribution systems' load which is composed of single or three phase are unbalanced by generating load unbalance. Unbalanced current will draw a highly unbalanced voltage. The power factor of an induction motor at rated operation is between 25 and 90%, depending on the size and speed of the motor. However, many induction motors operate below the nominal rating, resulting in poor power factor. This condition needs power factor improvement. Addition of power capacitor at the motor terminal may draw to stress due to voltage unbalance. This paper presents operation characteristics on steady states of a three-phase induction motor under unbalanced voltages with power capacitor. The existence of voltage unbalance have an effect on stress of power capacitor.

온라인 무정전전원장치의 병렬운전 제어기술 (Parallel Operation Control Technique of On-line UPS System)

  • 조준석;강병희;고재석;최규하;김진홍;정석언
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.501-505
    • /
    • 2001
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.

  • PDF