• Title/Summary/Keyword: Balanced operation

Search Result 267, Processing Time 0.03 seconds

A Study on Balanced Operation for Efficiency Improvement of Single Phase Induction Motor (단상유도전동기의 효율개선을 위한 평형운전에 관한 연구)

  • Baek, Soo-Whang;Kim, Byung-Taek;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.143-145
    • /
    • 2006
  • In this paper, single phase induction motor achieved improvement in efficiency by adapting the condition of Balanced operation and Quasi-balanced operation. Also, the process of efficiency improvement to find the optimum point of secondary resistance and running capacitor for working single phase induction motor is performed in order to attain the conclusion to put out the maximum efficiency at the rated operation point with meeting the starting torque.

  • PDF

Parallel Operation of Three-Phase Four wire UPS using Droop Control (Droop Control을 이용한 3상 4선식 UPS의 병렬운전)

  • Kim, Hyunseob;Han, Jungho;Song, Joong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.88-95
    • /
    • 2013
  • A new droop control method which can be applied to 3-phase 4-wire uninterruptible power supply is proposed in this paper. The droop control method for parallel operation is very attractive one as UPS parallel operation can be carried out without any data communication devices provided among UPS systems connected, but it reportedly shows a PnP(plug-and-play) problem. A basic reason why a circulating current could flow among parallel-connected UPS systems is clearly investigated as well when droop-controlled-ups systems are operated in the manner of PnP. The proposed algorithm is deduced from the investigated result and is basically structured to keep a balanced frequency and balanced voltage profile against power variation. This paper shows that balanced parallel operation of droop control method can be obtained under unbalanced load as well as balanced load conditions when PnP operation is needed and load change occurs.

Practical Optimum Design of Single-phase Induction Motor Based on Balanced Operation Theory (평형운전에 기초한 단상 유도전동기의 실용적인 설계)

  • Baek, Soo-Whang;Kim, Byung-Taek;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.129-131
    • /
    • 2007
  • In this paper, we research improvement in efficiency of single-phase induction motor by adapting the condition of the balanced and quasi-balanced operation. we maintain turns of auxiliary winding of the motor and adjust resistance and reactance. In this condition, resistance value and copper loss are much gloater. Namely, this is the condition only for balancing MMF without consideration of copper loss of stator winding. To make more practical design, therefore, we will perform winding design which is based on balanced operation condition and applies copper loss minimum. The problem of deterioration of starting torque is completed by rotor bar shape design.

  • PDF

콘덴서 런 단상유도전동기의 설계적 고찰

  • 원종수
    • 전기의세계
    • /
    • v.31 no.2
    • /
    • pp.132-140
    • /
    • 1982
  • Designing the capacitor-run motor for balanced operation is accompanied with the excessive capacitor value and low capacitor terminal voltage of condenser. As a solution for this problems, It was reported the design by equal volt-ampere method. The running characteristics of capacitor-run motor by this method due to the balancing point selection, however, has a room to be studied further. This paper deals with the determination of the winding ratio and capacitor value of a permarient-split capacitor motor by balanced operation and equal volt-ampere method at the different load points. The analysis of the running characteristics of a motor and its designing method also presented for both cases. It concluded that the running characteristics due to the equal volt-ampere operation are very close to the balanced operation.

  • PDF

Evaluating Green IT Initiatives Using the Sustainability Balanced Scorecard (지속가능한 BSC를 사용한 그린 IT 전략 실행과제들의 평가)

  • Park, Jeong-Sun
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.3
    • /
    • pp.81-87
    • /
    • 2017
  • Performance evaluation has been done using financial indices which are generally regarded as inappropriate for the organizations which are innovative and progressive. Thus, the Balanced Scorecard(BSC) was developed considering long term performance and invisible performance. This BSC has four perspectives of finance, customer, internal operation, and learning. Based on the BSC, a new BSC has been derived with a fifth view of environmental and social perspective, which is now called as a Sustainability BSC. In this study, we evaluated Green IT initiatives using the Sustainability BSC. The initiatives are categorized as RFID, telepresence, paperless office, logistics management etc. The initiatives were evaluated from the view of five perspectives, resulting in high cor relationships among finance, internal operation, and environmental and social perspectives. Namely, good initiatives from the view of environmental/social perspective are also evaluated as good from the view of finance and internal operation perspectives. In this study, we recommend organizations to introduce Green IT initiatives by showing how Green IT initiatives have contributed to the organizations.

Rural Water Supply from the Irrigation Reservoir

  • 김대철;박성기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.E
    • /
    • pp.47-54
    • /
    • 1995
  • Irrigation water has been mainly used for paddy rice. Irrigated paddy land tends to be recently converted to land for green house, farm house, and rural-industrial complex. Consequently, demand of water for crops, domestic & industrial, rural recreations, small-scaled hydropower, livestocks, and environment in the rural area, so called rural water, is rapidly increasing. In order to supply rural water, water in the existing irrigation reservoir could be enlarged by repairment of irrigation canal and reinforcement of irrigation reservoir, and be saved by the operation rule curve, utilization of dead water, and balanced storage management.

  • PDF

Design Methodology for Minimal Stator Copper Loss in A Single-phase Induction Motor (단상 유도전동기의 고정자 동손 최소화를 위한 설계 방법)

  • Baek, Soo-Whang;Kim, Byung-Taek;Kwon, Byung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1536-1545
    • /
    • 2008
  • In this paper, we research a new method for efficiency improvement of a single-phase Induction motor by minimization of the stator loss. To make this, we perform winding design which is based on balanced and quasi-balanced operation condition. It gives efficiency improvement greatly but poor starting torque simultaneously. To obtain the best efficiency improvement maintaining the maximum and starting torque, the optimal winding specification and rotor dimension is determined with variation of secondary resistance, running capacitor and turn ratio. Finally, this paper gives the comparison between the simulation results and experimental results.

A Strategy for Balanced Power Regulation of Energy Storage Systems in a Distribution System during Closed-Loop Operation

  • Han, Yoon-Tak;Oh, Joon-Seok;Cha, Jae-Hun;An, Jae-Yun;Hyun, Seung-Yoon;Lee, Jong-Kwan;Seo, In-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2208-2218
    • /
    • 2017
  • To resolve overload in a distribution system, a distribution system operator (DSO) often performs a load transfer using normally open tie points and switches in the distribution line. During this process, the distribution system is momentarily operated in closed-loop operation. A closed-loop current in the distribution system can cause a power failure due to excess breaking current in the circuit breakers and reclosers. Therefore, it is necessary to calculate the closed-loop current exactly. However, if there are a large number of distributed generation (DG) systems in the distribution system, such as energy storage systems (ESS), they might obstruct the closed-loop operation based on bidirectional power flow. For quick and precise operation of a closed-loop system, the ESS has to regulate the power generation while satisfying closed-loop operation in the worst cases. We propose a strategy for balanced power regulation of an ESS. Simulations were carried out using PSCAD/EMTDC, and the results were compared with calculation results.

A Study on the Parallel Operation Control Technique of On-line UPS System (무정전전원장치의 병렬운전 제어기법에 관한 연구)

  • 곽철훈;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.585-592
    • /
    • 2003
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between Inverters on synchronous d-q reference frame.

A Study on Design of S-BSC(Safety-Balanced ScoreCard) for Total Safety Evaluation (종합 안전평가를 위한 S-BSC(Safety-Balanced ScoreCard) 설계에 관한 연구)

  • Yang, Kwang-Mo
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.3
    • /
    • pp.1-8
    • /
    • 2008
  • Risk is the probability of an adverse event given exposure to hazard. There are many reason for unsafety situation without safety operation. The reason is no safety evaluation system in small enterprise. And then this study purposes safety management activities that is evaluation system for total safety efficiency's maximization. Therefore, in this study, this model that can evaluate quantitative activities in small enterprise that maximize safety efficiency wishes to do design using balanced scorecard. In other words, this study aims to suggest a performance measurement model reflecting the characteristics of safety evaluation system, especially the model for return manufacturing related to safety, and to develop the S-BSC(Safety-Balanced ScoreCard) measurement model using a weight lifetime value to which a relative weight is applied by using AHP based on the BSC.