• Title/Summary/Keyword: Balance of Plant

Search Result 429, Processing Time 0.028 seconds

Systems Engineer Program for Practical Nuclear Power Plant Engineering Education (실용적인 원전공학 교육을 위한 시스템즈 엔지니어 프로그램)

  • Chang, Choong-koo;Jung, Jae-cheon;DIA, Aminata
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.11 no.2
    • /
    • pp.31-40
    • /
    • 2015
  • KEPCO International Nuclear Graduate School (KINGS) is dedicated to nurturing leadership-level professionals in nuclear power plant (NPP) engineering. KINGS have designed curriculum based on two philosophies. First, we balance aspects of discipline engineering, specialty engineering, and management engineering in the framework of systems engineering. Second, KINGS have designed the curriculum so that students can learn and experience the know-what, know-how and know-why level knowledge of NPP engineering and management. The specialization programs are opened during the 2nd year for 3 trimesters and those are a process of learning through practical project courses. The objectives of the specialization programs are to help students to learn the NPP life cycle technologies in highly structured and systematic ways. The systems engineer program (SEP) is one of the specialization programs. A practical case of the SEP which was applied to the project course for the NPP electric power system design education will be elaborated in this paper.

Feasibility Study on the Development of Environmental Friendly Livestock Complex in the Reclaimed Tideland (간척지 자연순환형 친환경축산단지 도입 타당성 연구)

  • Heo, Nam-Hyo;Lee, Seung-Heon;Kim, Byeong-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.430-433
    • /
    • 2009
  • The development of large-scale environmental friendly livestock complex in the reclaimed tideland is one of different alternatives to increase the competitiveness of internal livestock industry against an international opening markets as DDA and FTA in agricultural field. Recently, it is possible to introduce an environmental friendly livestock complex in the reclaimed tideland by an amendment of the acts for agricultural land. However more studies that are on the basis of nitrogen and phosphorus mass balance need to preserve the agricultural environments as the quality of agricultural water and soil in rural area. In this study, the reference for feasibility study is Whaong reclaimed tideland which located at Whaseong city, Gyeonggi Province, and a basic concept of environmental friendly livestock complex is the production of forage crops with the supply of liquid fertilizer and the production of bioenergy such as biogas by the recycling of pig slurry as a resource. The mass balance of nitrogen based on between forage crops such as maize, barley and liquid fertilizer supplied at the reclaimed tideland, and also it was estimated an economical efficiency as anaerobic digestion plant for treating pig slurry of $100m^3/day$ introduce in an environmental friendly livestock complex.

  • PDF

Development of a Scaling Factor Prediction Method for Radioactive Composition in Low-level Radioactive Waste

  • Park, Jin-Beak;Lee, Kun-Jai
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.833-838
    • /
    • 1995
  • This study presents a method to predict plant-specific and operational history dependent scaling factors. Realistic and detailed approaches are taken to find scaling factors at reactor coolant. This approach begins with fission product release mechanisms and fundamental release properties of fuel-source nuclide such as fission product and transuranic nuclide. Scaling factors at various waste streams are derived from the predicted reactor coolant scaling factors with the use of radionuclide retention and build up model. This model makes use of radioactive material balance within the radioactive waste processing systems. According to input parameters of plant operation history, scaling factors predicted at reactor coolant and waste streams are well brought out the effects of plant operation history.

  • PDF

Modeling and Parameter Estimation of Superheater in Thermal Power Plant (화력발전소 과열기 모델링 및 파라미터 추정)

  • Shin, Yong-Hwan;Li, Xin-Lan;Shin, Hwi-Beom
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.600-601
    • /
    • 2010
  • This paper presents the superheater dynamic modeling and parameter estimation for the thermal plant boiler. The temperature control is closely related to the power plant efficiency and boiler life. The dynamic modeling of the superheater and desuperheater is essentially needed and developed by using the heat balance principle. The simulated model outputs are well matched with the actual ones. It is expected that the proposed model is useful for the temperature controller design.

  • PDF

Application of Dynamic Model for Steam Turbine and its Parameter Estimation in a Fossil Fired Power Plant

  • Choi, Inkyu;Woo, Joohee;Kim, Byoungchul;Son, Gihun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.409-413
    • /
    • 2016
  • The 500 MW rated steam turbine model in coal fired power plant is developed to be used for validation and verification of controller rather than for the education of operator. The valve, steam turbine, reheater and generator are modeled and integrated into the simulator. And the data from the plant heat balance diagram are used for estimation of the model parameters together with actual operating data. It is found that the outputs of model such as pressure, temperature and speed are similar to the operating ones. So, it is expected that the developed model will play a very big role in controller development.

Tube Plugging Criteria for the Non-Regenerative Heat Exchanger in the Steam Generator Blowdown System of Nuclear Power Plant (증기발생기 취출수계통 비재생열교환기 전열관 관막음 기준 설정)

  • Kim, Hyeong-Nam;Choe, Seong-Nam;Yu, Hyeon-Ju;Choe, Jin-Hyeok
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.38-40
    • /
    • 2006
  • Nuclear power plants are urged to reduce operating and maintaining costs to remain competitive as well as to increase the safety preventing the radioactive material to the atmosphere. To reduce the cost and to increase the safety, the inspection of balance-of-plant heat exchanger becomes important. However, there are some problems for plugging the heat exchanger tubes since the criterion and its basis are not clearly described. The codes and standards related to show the tube plugging criteria may not exist currently. In this paper, a method to establish the tube plugging criteria of BOP heat exchangers is introduced and the tube plugging criteria for the non-regenerative heat exchanger in the steam generator blow-down system of nuclear power plant. This method relies on the similar method used to establish the plugging criteria for the steam generator tubes.

  • PDF

Comparisons of Ion Balance, Fruit Yield, Water, and Fertilizer Use Efficiencies in Open and Closed Soilless Culture of Paprika (Capsicum annuum L.)

  • Ko, Myat Thaint;Ahn, Tae In;Son, Jung Eek
    • Horticultural Science & Technology
    • /
    • v.31 no.4
    • /
    • pp.423-428
    • /
    • 2013
  • Although closed soilless culture is useful for saving water and fertilizers with minimizing environmental pollution, adequate management of nutrient solutions is still not stabilized in greenhouse cultivation. In order to investigate the problems occurred in closed soilless culture of Paprika (Capsicum annuum L., cv. Fiesta), we compared ion balance, fruit yield, and the water and fertilizer use efficiencies in the closed system with those in the open system. The plants were grown in rockwool culture with a nutrient solution of EC $2.5dS{\cdot}m^{-1}$. After 4 weeks of treatment, individual ratio of $NO{_3}^-$, $K^+$, $Ca^{2+}$, and $Mg^{2+}$ to total ion concentrations ($meq{\cdot}L^{-1}$) decreased from the initial value, especially the biggest decrement was observed in $K^+$, and on the other hand, $SO{_4}^{2-}$, $Cl^-$, and $Na^+$ were accumulated in the closed system. Yields after four-time harvests were 19% higher in the open system than in the closed system. Total volume of water used per unit area ($m^2$) in the open system was 20% higher, but the total water use per fruit was not significantly different between the two systems, while t total fertilizer use per fruit was 78% higher in the closed system. Amount of marketable fruits was not significantly different between the two systems. We concluded that the increase in $K^+$ supply and the replenishment of recycled nutrient solution every four weeks were required for preventing the imbalance or depletion of nutrients in the close soilless culture of paprika plants to get more balanced nutrient composition during whole cultivation period.

Study on the Multi-Zone Furnace Analysis Method for Power Plant Boiler (발전용 보일러에 대한 다중영역분할 화로해석 기법의 활용성 연구)

  • Baek, SeHyun;kim, Donggyu;Lee, Jang Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.427-432
    • /
    • 2020
  • In this study, a multi-zone furnace analysis method that couples a 1D energy and mass balance calculation with a 3D radiative heat transfer calculation is tested in order to verify its reliability. The calculated results for a domestic 500 MW capacity coal-fired boiler furnace were compared with the design data of the boiler manufacturer and CFD analysis, and a good agreement was achieved. Although this calculation method is less sophisticated than the CFD furnace analysis, it has an advantage in terms of calculation time while being able to provide the furnace behavior according to the fuel characteristics and operational variable changes. Therefore, it is expected to be useful for boiler operation diagnosis and daily fuel/operation planning.

Transposable Elements and Genome Size Variations in Plants

  • Lee, Sung-Il;Kim, Nam-Soo
    • Genomics & Informatics
    • /
    • v.12 no.3
    • /
    • pp.87-97
    • /
    • 2014
  • Although the number of protein-coding genes is not highly variable between plant taxa, the DNA content in their genomes is highly variable, by as much as 2,056-fold from a 1C amount of 0.0648 pg to 132.5 pg. The mean 1C-value in plants is 2.4 pg, and genome size expansion/contraction is lineage-specific in plant taxonomy. Transposable element fractions in plant genomes are also variable, as low as ~3% in small genomes and as high as ~85% in large genomes, indicating that genome size is a linear function of transposable element content. Of the 2 classes of transposable elements, the dynamics of class 1 long terminal repeat (LTR) retrotransposons is a major contributor to the 1C value differences among plants. The activity of LTR retrotransposons is under the control of epigenetic suppressing mechanisms. Also, genome-purging mechanisms have been adopted to counter-balance the genome size amplification. With a wealth of information on whole-genome sequences in plant genomes, it was revealed that several genome-purging mechanisms have been employed, depending on plant taxa. Two genera, Lilium and Fritillaria, are known to have large genomes in angiosperms. There were twice times of concerted genome size evolutions in the family Liliaceae during the divergence of the current genera in Liliaceae. In addition to the LTR retrotransposons, non-LTR retrotransposons and satellite DNAs contributed to the huge genomes in the two genera by possible failure of genome counter-balancing mechanisms.

Performance Evaluation of an Oxy-coal-fired Power Generation System - Thermodynamic Evaluation of Power Cycle (순산소 석탄 연소 발전 시스템의 성능 평가 - 동력 사이클의 열역학적 해석)

  • Lee, Kwang-Jin;Choi, Sang-Min;Kim, Tae-Hyung;Seo, Sang-Il
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.2
    • /
    • pp.1-11
    • /
    • 2010
  • Power generation systems based on the oxy-coal combustion with carbon dioxide capture and storage (CCS) capability are being proposed and discussed lately. Although a large number of lab scale studies for oxy-coal power plant have been made, studies of pilot scale or commercial scale power plant are not enough. Only a few demonstration projects for oxy-coal power plant are publicized recently. The proposed systems are evolving and various alternatives are to be comparatively evaluated. This paper presents a proposed approach for performance evaluation of a commercial 100 MWe class power plant, which is currently being considered for 'retrofitting' for the demonstration of the concept. The system is configurated based on design and operating conditions with proper assumptions. System components to be included in the discussion are listed. Evaluation criteria in terms of performance are summarized based on the system heat and mass balance and simple performance parameters, such as the fuel to power efficiency and brief introduction of the second law analysis. Also, gas composition is identified for additional analysis to impurities in the system including the purity of oxygen and unwanted gaseous components of nitrogen, argon and oxygen in air separation unit and $CO_2$ processing unit.