Tube Plugging Criteria for the Non-Regenerative Heat Exchanger in the Steam Generator Blowdown System of Nuclear Power Plant

증기발생기 취출수계통 비재생열교환기 전열관 관막음 기준 설정

  • Published : 2006.10.19

Abstract

Nuclear power plants are urged to reduce operating and maintaining costs to remain competitive as well as to increase the safety preventing the radioactive material to the atmosphere. To reduce the cost and to increase the safety, the inspection of balance-of-plant heat exchanger becomes important. However, there are some problems for plugging the heat exchanger tubes since the criterion and its basis are not clearly described. The codes and standards related to show the tube plugging criteria may not exist currently. In this paper, a method to establish the tube plugging criteria of BOP heat exchangers is introduced and the tube plugging criteria for the non-regenerative heat exchanger in the steam generator blow-down system of nuclear power plant. This method relies on the similar method used to establish the plugging criteria for the steam generator tubes.

Keywords