• Title/Summary/Keyword: Bad smell

Search Result 88, Processing Time 0.023 seconds

Plug-in Diverse Parsers Within Code Visualization System with Redefining the Coupling and Cohesion in the Object-Oriented Paradigm (객체지향 관점의 결합도 & 응집도 재정의와 코드 가시화 시스템내 파서 플러그인화 구현)

  • Lee, Jin Hyub;Park, Ji Hun;Byun, Eun Young;Son, Hyun Seung;Seo, Chae Yun;Kim, R. Young Chul
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.5
    • /
    • pp.229-234
    • /
    • 2017
  • Because of the invisible nature of software and the bad coding habits (bad smell) of the existing developers, there are many redundant codes and unnecessary codes, which increases the complexity and makes it difficult to upgrade software. Therefore, it is required a code visualization so that developers can easily and automatically identify the complexity of the source code. To do this, it is necessary to construct SW visualization tool based on open source software and redefine the coupling and cohesion according to the object oriented viewpoint. Specially to identify a bad smell code pattern, we suggest how to plug-in diverse parsers within our tool. In this paper, through redefining coupling and cohesion from an object oriented perspective, we will extract bad smell code patterns within source code from inputting any pattern into the tool.

The Development of Sewer Drainage for Harmful Insect and Bad Smell Prevention (침수방지와 방충.방취 기능을 갖는 오우배수장치의 개발)

  • Kim, Yong-Seok;Park, Sung-Ho;Yang, Soon-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.3
    • /
    • pp.94-100
    • /
    • 2008
  • New type of the sewer drainage has been developed to overcome present sewer drainage's shortcoming. This system has the function of drainage, sewerage, reverse flow prevention, and harmful insect and smell prevention. Numerical simulation has been carried out in order to minimize the troubles that can be happened in the process of manufacture and installation process. This sewer drainage system for harmful insect and smell prevention intercepts pollution source, and then it prohibit second pollution. Harmful insect cannot go in and out in this system. Also, this system can reduce the damage of flooded districts due to heavy rain because it is impossible to flow backward from sewer drainage.

Clinical Features of Knee Pain of Female after Menopausal and Survey Method for Moxibustion Treatment (폐경기 이후 여성의 슬통 양상과 뜸시술에 관한 설문)

  • Kang, Mi Suk
    • Journal of Acupuncture Research
    • /
    • v.30 no.5
    • /
    • pp.169-174
    • /
    • 2013
  • Objectives : This study was accomplished to find out clinical features of knee pain of female after menopausal and their recognition of moxibustion treatment. Methods : Before and after 8 times moxibustion treatment(mostly 2 times a weak), survey was done. Moxibustion treatment was done on painful location, 3 times per each point. Results & Conclusions : Other symptom with Knee pain was Click 30.8 %, stiffness 25.6 %, press pain 16.7 %, swelling 14.1 %, fever 5.1 %, none 7.7 %. VAS of moxibustion treatment is significantly increased after treatment. Expectation of moxibustion treatmen is not. "Bad smell" is the first cause of evasion of moxibustion therapy. It should have been considered to reduce bad smell in development of moxibustion.

Optimization of Design Parameters for Steel Grating Using Taguchi Method Considering Rigidity and Drainage Efficiency (다구찌기법 기반의 강성과 배수능력 관계를 고려한 스틸그레이팅의 설계변수 최적화)

  • Kim, Woo-Tae;Lee, Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.8
    • /
    • pp.905-910
    • /
    • 2014
  • The steel grating discussed in this study is a drain cover that enhances the rigidity of the steel frame using an inclined inflow tract for wastewater, facilitates smooth drainage, and prevents the escape of bad smell from the drain. Recently, the urban problem of bad smell in sewerage lines has been hindering the improvement of living standards. Moreover, the frequent failure of existing products deters bad smell prevention measures and results in administrative power and budget wastage. The pressure to reduce budgets propels the increased demand for functional steel grating. Thus, this study focused on optimizing the design parameters of a steel grating by simultaneously considering its rigidity and drainage efficiency.

A Catalog of Bad Smells in Design-by-Contract Methodologies with Java Modeling Language

  • Viana, Thiago
    • Journal of Computing Science and Engineering
    • /
    • v.7 no.4
    • /
    • pp.251-262
    • /
    • 2013
  • Bad smells are usually related to program source code, arising from bad design and programming practices. Refactoring activities are often motivated by the detection of bad smells. With the increasing adoption of Design-by-Contract (DBC) methodologies in formal software development, evidence of bad design practices can similarly be found in programs that combine actual production code with interface contracts. These contracts can be written in languages, such as the Java Modeling Language (JML), an extension to the Java syntax. This paper presents a catalog of bad smells that appear during DBC practice, considering JML as the language for specifying contracts. These smells are described over JML constructs, although several can appear in other DBC languages. The catalog contains 6 DBC smells. We evaluate the recurrence of DBC smells in two ways: first by describing a small study with graduate student projects, and second by counting occurrences of smells in contracts from the JML models application programming interface (API). This API contains classes with more than 1,600 lines in contracts. Along with the documented smells, suggestions are provided for minimizing the impact or even removing a bad smell. It is believed that initiatives towards the cataloging of bad smells are useful for establishing good design practices in DBC.

Burning Up of the Sludge occurred during Activated Sludge Treatment of Washing Wastewater and by-product Waste in Cuttlefish Processing Manufacture (활성오니법에 의한 오징어 가공공장 폐액처리중에 발생하는 슬러지의 소각재처리)

  • 조순영;서재수
    • Journal of Environmental Science International
    • /
    • v.4 no.2
    • /
    • pp.195-220
    • /
    • 1995
  • A lot of sludges occur during an activated sludge treatment process of the washing wastewater and by-product waste in the cuttlefish processing manufacture. The sludges give also out a bad smell, and their amicable reclamation is very difficult because of the limited area of the filling-up. To reduce the heavy weight and large volume of the sludges, they was burning up. After the burning up at 350t for 2hrs the weight(volume) of the sludges were reduced to 5% level of the initial value. In contents of the bad heavy metals for human after the burning up, cadmium and lead metal were slightly detected, while mercury and the bad others not detected.

  • PDF

Effect of Bad Breath on Olfactory Identification Ability and on Olfactory Detection Threshold for CH3SH (구취가 후각인지도 및 methyl mercaptan에 대한후각감지역치에 미치는 영향)

  • Do, Young-Hwan;Choi, Jae-Kap;Ahn, Hyoung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.4
    • /
    • pp.309-318
    • /
    • 2001
  • The purposes of the study were (1) to evaluate the olfactory identification ability in those who have bad breath, (2) to determine the olfactory detection threshold for methyl mercaptan in normal subjects and those who have bad breath, and (3) to evaluate the effect of oral hygiene care on the olfactory detection threshold for methyl mercaptan. Sixteen male subjects with bad breath (male odor group), 9 male subjects without bad breath (male non-odor group), and 10 female subjects without bad breath (female non-odor group) were included for the study. Olfactory identification ability was assessed by administrating the Cross-Cultural Smell Identification Test (CC-SIT), and the olfactory detection threshold for methyl mercaptan was measured by two-alternative forced-choice single-staircase detection threshold procedure in a double-blinded condition. The geometric mean of the last four staircase reversal points of a total of seven reversals is used as the threshold. For the male odor group, after 1 month of intensive oral hygiene care for reducing oral volatile sulfur compounds (VSC) concentration, the olfactory detection threshold for methyl mercaptan was measured again and compared to the initial value. The ANOVA was used to test the group difference of olfactory threshold and olfactory identification ability and the paired t-test was used to test the difference of olfactory threshold between before and after reduction of oral VSC in male odor group. The results were as follows : 1. There was no significant difference in olfactory identification ability among those who have bad breath and normal male or female subjects. 2. The olfactory detection threshold for methyl mercaptan was about 8.4 ppb in normal male and female. 3. There was a tendency that male subjects with bad breath showed a higher olfactory detection threshold for methyl mercaptan when compared to those of no bad breath. 4. The olfactory detection threshold for methyl mercaptan returned to a normal level after 1 month of intensive oral hygiene care for reducing oral VSC.

  • PDF

The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures I: Characteristics of the Foul-Smelling Sewer Pipe in Residential Areas (대규모 아파트 단지주변 하수관로의 악취 발생과 대책 1: 주거지역 하수관로의 악취 발생 특성)

  • Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.621-629
    • /
    • 2007
  • This study intends to investigate the characteristics of the foul smell of sewer pipes near large apartment complexes as complaints about offensive odors have drastically increased in urban residential areas. Targeting apartments where people actually complained about foul orders, the study result revealed that components in the smell of the water-purifier tank of the target apartment were very similar to those of sewage treatment plants and night soil treatment plants. Measuring components of odors inside the management layer of tank showed that the concentration of hydrogen sulfide was 10ppm, which is approximately 160 times the safety standard of 0.06ppm; the concentration of mercaptan was 0.9ppm, which is about 220 times the safety standard of 0.004ppm. The source materials of foul odors were discharged outside through ducts, and those households living near outlets producing bad smell complain that it gets worse depending on the air pressure or wind direction and strength, and they could not even open windows. As well, these source materials were transferred by discharge pumps to public sewer pipes outside the apartment complex. While discharge pumps starts operating, they remain on the sewer pipe and then begin to spread over to roads through small openings of manholes on the road. Then, the smell offends passers-by and residents near the road, leading to a lot of complaints. The study results suggest that, among the sources of foul odors in sewer pipes of residential areas, especially those from the water-purifier tank of large apartments, hydrogen sulfide should be the main target for follow-up treatment.

Resident's Subjective Responses to Indoor Air quality of Multi Family Houses in Winter (공동주택의 겨울철 실내공기환경에 대한 거주자 반응)

  • 윤정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.2
    • /
    • pp.173-186
    • /
    • 1997
  • The purpose of this study is to find out understand the resident's subjective responses to physical indoor environment. The questionnaire survey was carried out to measure form Jan. 8th to Feb. 2th in 1996, the typical external climate of winter in Korea. The subjects were four hundred and eleven housewives, living in apartments of RC structure I Ilsan apartment complex. As the result, residents usual ventilate once or twice a day by opening outward windows for about ten minutes. Unpleasant smell producted by cooking and wet garbage made most of them negatively respond to kitchen's air quality. regression analysis of relativeness between sense of air freshness smell, dust and comfort revealed that sense of comfort was the most highly related with the extent of bad smell. Housing factors such as size of apartments and ventilating, smoking and gas usage had significant effects on indoor air quality and the subjective responses in winter. Therefore it is especially important to consider air pollution problem from the beginning stage when planning small apartments. It is required that the government of environment has to emphasize the importance of ventilation to residents, and makes an effort to establish the design criteria on indoor air quality in house.

  • PDF

A Case Study on the Development of New Process for Treatment of Waste Waters from Ships (선박폐수 처리공정의 개발에 관한 사례)

  • Choi, Sang-Mo;Heo, In-Seok;Yang, Seok-Jun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 2009
  • Korea Marine Environment Management Corporation (KOEM) has waste oil facilities in 13 ports to collect and treat waste oil, bilge, etc. from ships based upon the Marine Environment Management Act of Korea and MARPOL 73/78 convention. Those facilities were designed and have been operated simply to discharge water under the level 15 ppm of oil contents. However, bad smells occurred from rotten organic matters in waste water and direct discharge of harmful substances to receiving water caused civil appeals. Therefore, KOEM tried to develop new process for treatment of oily waste water from ships, which could mitigate harmful substances, save cost, calm down civil appeals and contribute to marine environment preservation. This process consists of 3 steps to remove oil contents via gravity variation at first, $O_3$ input to contact water and organism deposition by inputting condensate deposits. Then finally upper water will be discharged, and the deposited substances in the bottom will be compressed through spinning machine to transfer to the designated contractors for treatment of wastes. This is very effective and innovative in that it could reduce 3 or 4 steps compared with existing process and mitigate not only waste oil concentration but also hard resolving materials such as colloid, ABS, phosphorus, nitrogen and bad smells. This method is expected to minimize bad smells and harmful gases, to save more than 10% of maintenance cost, and to arrange the good base for garbage treatment business dealing with waste water and bad smell.

  • PDF