• Title/Summary/Keyword: Background imaged

Search Result 17, Processing Time 0.025 seconds

A Study on the Fashion Design imaged by Hand Work (핸드 워크 감각(感覺)의 패션 디자인 연구(硏究))

  • Yum, Hae-Jung
    • Journal of Fashion Business
    • /
    • v.10 no.2
    • /
    • pp.166-180
    • /
    • 2006
  • The purpose of this study is to analyze the fashion images and the aesthetic characteristics of hand work imaged design. The 'hand work' has not only affected the contemporary life style but also the current fashion trend. The primary source of data has been a collection of recent books, news repots, and many articles from various kinds of mass media and fashion magazines since the year 2000. The results of this study can be summarized as follow. First, hand work imaged fashion design can be divided the background into three parts : post-materialism, aesthetics of slowness, personalize trend. Second, hand work imaged fashion design can be identified with the following images : folklore & craft image, second hand image, high touch image. Third, the aesthetic characteristics of hand work image reflects the concepts of sustainability and process communication.

Assessment and Comparison of Three Dimensional Exoscopes for Near-Infrared Fluorescence-Guided Surgery Using Second-Window Indocyanine-Green

  • Cho, Steve S.;Teng, Clare W.;Ravin, Emma De;Singh, Yash B.;Lee, John Y.K.
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.4
    • /
    • pp.572-581
    • /
    • 2022
  • Objective : Compared to microscopes, exoscopes have advantages in field-depth, ergonomics, and educational value. Exoscopes are especially well-poised for adaptation into fluorescence-guided surgery (FGS) due to their excitation source, light path, and image processing capabilities. We evaluated the feasibility of near-infrared FGS using a 3-dimensional (3D), 4 K exoscope with near-infrared fluorescence imaging capability. We then compared it to the most sensitive, commercially-available near-infrared exoscope system (3D and 960 p). In-vitro and intraoperative comparisons were performed. Methods : Serial dilutions of indocyanine-green (1-2000 ㎍/mL) were imaged with the 3D, 4 K Olympus Orbeye (system 1) and the 3D, 960 p VisionSense Iridium (system 2). Near-infrared sensitivity was calculated using signal-to-background ratios (SBRs). In addition, three patients with brain tumors were administered indocyanine-green and imaged with system 1, with two also imaged with system 2 for comparison. Results : Systems 1 and 2 detected near-infrared fluorescence from indocyanine green concentrations of >250 ㎍/L and >31.3 ㎍/L, respectively. Intraoperatively, system 1 visualized strong near-infrared fluorescence from two, strongly gadolinium-enhancing meningiomas (SBR=2.4, 1.7). The high-resolution, bright images were sufficient for the surgeon to appreciate the underlying anatomy in the near-infrared mode. However, system 1 was not able to visualize fluorescence from a weakly-enhancing intraparenchymal metastasis. In contrast, system 2 successfully visualized both the meningioma and the metastasis but lacked high resolution stereopsis. Conclusion : Three-dimensional exoscope systems provide an alternative visualization platform for both standard microsurgery and near-infrared fluorescent guided surgery. However, when tumor fluorescence is weak (i.e., low fluorophore uptake, deep tumors), highly sensitive near-infrared visualization systems may be required.

Visualizing the distributions and spatiotemporal changes of metabolites in Panax notoginseng by MALDI mass spectrometry imaging

  • Sun, Chenglong;Ma, Shuangshuang;Li, Lili;Wang, Daijie;Liu, Wei;Liu, Feng;Guo, Lanping;Wang, Xiao
    • Journal of Ginseng Research
    • /
    • v.45 no.6
    • /
    • pp.726-733
    • /
    • 2021
  • Background: Panax notoginseng is a highly valued medicinal herb used widely in China and many Asian countries. Its root and rhizome have long been used for the treatment of cardiovascular and hematological diseases. Imaging the spatial distributions and dynamics of metabolites in heterogeneous plant tissues is significant for characterizing the metabolic networks of Panax notoginseng, and this will also provide a highly informative approach to understand the complex molecular changes in the processing of Panax notoginseng. Methods: Here, a high-sensitive MALDI-MS imaging method was developed and adopted to visualize the spatial distributions and spatiotemporal changes of metabolites in different botanical parts of Panax notoginseng. Results: A wide spectrum of metabolites including notoginsenosides, ginsenosides, amino acids, dencichine, gluconic acid, and low-molecular-weight organic acids were imaged in Panax notoginseng rhizome and root tissues for the first time. Moreover, the spatiotemporal alterations of metabolites during the steaming of Panax notoginseng root were also characterized in this study. And, a series of metabolites such as dencichine, arginine and glutamine that changed with the steaming of Panax notoginseng were successfully screened out and imaged. Conclusion: These spatially-resolved metabolite data not only enhance our understanding of the Panax notoginseng metabolic networks, but also provide direct evidence that a serious of metabolic alterations occurred during the steaming of Panax notoginseng.

Pretargeting : A concept refraining traditional flaws in tumor targeting

  • Bhise, Abhinav;Yoo, Jeongsoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.1
    • /
    • pp.53-58
    • /
    • 2020
  • Pretargeting is a two-component strategy often used for tumor targeting to enhance the tumor-to-background ratio in cancer diagnosis as well as therapy. In the multistep strategy, the highly specific unlabeled monoclonal antibodies (mAbs) with the reactive site is allowed to get localized at tumor site first, and then small and fastclearing radiolabeled chelator with counter reactive site is administered which covalently attaches to mAbs via inverse electron demand Diels-Alder reaction (IEDDA). The catalyst-free IEDDA cycloaddition reaction between 1,2,4,5-tetrazines and strained alkene dienophiles aid with properties like selective bioconjugation, swift and high yielding bioorthogonal reactions are emergent in the development of radiopharmaceutical. Due to its fast pharmacokinetics, the in vivo formed radioimmunoconjugates can be imaged at earlier time points by short-lived radionuclides like 18F and 68Ga; it can also reduce radiation damage to the normal cells. Ultimately, this review elucidates the updated status of pretargeting based on antibodies and IEDDA for tumor diagnosis (PET and SPECT) and therapy.

Front Points Tracking in the Region of Interest with Neural Network in Electrical Impedance Tomography

  • Seo, K.H.;Jeon, H.J.;Kim, J.H.;Choi, B.Y.;Kim, M.C.;Kim, S.;Kim, K.Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.118-121
    • /
    • 2003
  • In the conventional boundary estimation in EIT (Electrical Impedance Tomography), the interface between anomalies and background is expressed in usual as Fourier series and the boundary is reconstructed by obtaining the Fourier coefficients. This paper proposes a method for the boundary estimation, where the boundary of anomaly is approximated as the interpolation of front points located discretely along the boundary and is imaged by tracking the points in the region of interest. In the solution to the inverse problem to estimate the front points, the multi-layer neural network is introduced. For the verification of the proposed method, numerical experiments are conducted and the results indicate a good performance.

  • PDF

LARGE SCALE MAGNETIC FIELDS IN LENS GALAXIES

  • NARASIMHA D.;CHITRE S. M.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.5
    • /
    • pp.355-359
    • /
    • 2004
  • Differential Faraday Rotation measurements between the images of same background source, of multiply-imaged gravitational lens systems can be effectively used to provide a valuable probe to establish the existence of large-scale ordered magnetic fields in lensing galaxies as well as galaxy clusters. Estimates of the magnetic field in lens galaxies, based on the radio polarization measurements do not appear to show any clear evidence for evolution with redhsift of the coherent large scale magnetic field between redshift of 0.9 and the present epoch. However, our method clearly establishes the presence of coherent large scale magnetic field in giant ellitpical galaxies.

Visual Dynamics Model for 3D Text Visualization

  • Lim, Sooyeon
    • International Journal of Contents
    • /
    • v.14 no.4
    • /
    • pp.86-91
    • /
    • 2018
  • Text has evolved along with the history of art as a means of communicating human intentions and emotions. In addition, text visualization artworks have been combined with the social form and contents of new media to produce social messages and related meanings. Recently, in text visualization artworks combined with digital media, communication forms with viewers are changing instantly and interactively, and viewers are actively participating in creating artworks by direct engagement. Interactive text visualization with additional viewer's interaction, generates external dynamics from text shapes and internal dynamics from embedded meanings of text. The purpose of this study is to propose a visual dynamics model to express the dynamics of text and to implement a text visualization system based on the model. It uses the deconstruction of the imaged text to create an interactive text visualization system that reacts to the gestures of the viewer in real time. Visual Transformation synchronized with the intentions of the viewer prevent the text from remaining in the interpretation of language symbols and extend the various meanings of the text. The visualized text in various forms shows visual dynamics that interpret the meaning according to the cultural background of the viewer.

Analysis and Comparison of MR Signal Strength and SNR Value for Optimal FOV (최적의 FOV를 위한 MR신호강도와 신호 대 잡음비 값의 비교분석)

  • Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.109-113
    • /
    • 2018
  • Despite the continuous development of software, it is continuously pursued to enlarge the examination area of FOV in order to reduce the factors of inconsistency in images that appear in continuous examination during wide area examination using contrast agent such as whole body angiography. In this study, we investigated the optimal FOV by comparing the SNR values according to the changes of FOV. The change of the FOV was gradually changed to $270{\times}200$, $300{\times}223$, $330{\times}244$, $360{\times}266$ and $380{\times}281$. SE images at TR 450 msec and TE 10 msec, FSE images at TR 2,000 msec, TE 80 msec, and GE images were scanned at TR 117 msec, and TE 16 msec. SNR values were calculated from the mean values of signal intensities of five phantom images and the signal intensity values of four background standard deviations. As a result of the study, the signal intensity and the SNR value according to the change of the FOV value gradually increased as the FOV was increased, but it was found that the SNR value decreased at a constant size. In conclusion, the results are different from previous studies that the SNR increases as the FOV increases. The cause of these results could not be confirmed. However methods that can be imaged and included within the effective FOV should be considered.

Comparative evaluation of ultrasonography with clinical respiratory score in diagnosis and prognosis of respiratory diseases in weaned dairy buffalo and cattle calves

  • Hussein, Hussein Awad;Binici, Cagri;Staufenbiel, Rudolf
    • Journal of Animal Science and Technology
    • /
    • v.60 no.12
    • /
    • pp.29.1-29.11
    • /
    • 2018
  • Background: Respiratory troubles have economic impacts in countries where livestock industry is an important segment of the agricultural sector, as well as these problems may cause significant economic losses for bovine producers. Various practical methods are used to assess diseases that affect the bovine respiratory system. Ultrasonography is a noninvasive tool that has been used frequently in diagnosis of various animal diseases. The present study was designed to establish whether thoracic ultrasonography is a diagnostic tool for detection of respiratory troubles in weaned buffalo and cattle calves, as well as to assess its prognostic value in comparison with clinical respiratory scores. Thirty five (15 buffalo and 20 cattle) calves were included. Twelve (6 buffalo and 6 cattle) clinically healthy calves were enrolled as controls. Results: Based on physical examinations, clinical respiratory scores (CRS), ultrasound lung scores (ULS) and postmortem findings, animals were classified into 4 groups as pulmonary emphysema (n = 8), interstitial pulmonary syndrome (n = 7), bronchopneumonia (n = 12), and pleurisy (n = 8). The mean values of CRS and ULS were significantly higher in diseased calves (P < 0.01). In calves with pulmonary emphysema and interstitial syndrome, thoracic ultrasonography revealed numerous comet-tail artifacts, which varied in numbers and imaging features. Furthermore, variable degrees of pulmonary consolidation with alveolograms and bronchograms were noticed in bronchopneumonic calves. In addition, thick irregular or fragmented pleura with pleural effusions and fibrin shreds were imaged in calves with pleurisy. A weak correlation was calculated between CRS and ULS (r = 0.55, P < 0.01). Hematologically, the counts of white blood cells, activities of aspartate aminotransferase and partial tensions of carbon dioxide were significantly increased in all diseased groups. Serum concentrations of total globulins were higher in claves with bronchopneumonia (P < 0.05). The partial tension of oxygen was decreased in all diseased calves (P < 0.05). Conclusions: Thoracic ultrasonography is a diagnostic tool for various lung troubles and assessment the grade and severity of pulmonary diseases, as well as it can be used as a follow-up tool for evaluating the prognosis of respiratory troubles and monitoring the efficacy of therapies.

Development of the Algofithm for Gaussian Mixture Models based Traffic Accident Auto-Detection in Freeway (GMM(Gaussian Mixture Model)을 적용한 영상처리기법의 연속류도로 사고 자동검지 알고리즘 개발)

  • O, Ju-Taek;Im, Jae-Geuk;Yeo, Tae-Dong
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.3
    • /
    • pp.169-183
    • /
    • 2010
  • Image-based traffic information collection systems have entered widespread adoption and use in many countries since these systems are not only capable of replacing existing loop-based detectors which have limitations in management and administration, but are also capable of providing and managing a wide variety of traffic related information. In addition, these systems are expanding rapidly in terms of purpose and scope of use. Currently, the utilization of image processing technology in the field of traffic accident management is limited to installing surveillance cameras on locations where traffic accidents are expected to occur and digitalizing of recorded data. Accurately recording the sequence of situations around a traffic accident in a freeway and then objectively and clearly analyzing how such accident occurred is more urgent and important than anything else in resolving a traffic accident. Therefore, in this research, existing technologies, this freeway attribute, velocity changes, volume changes, occupancy changes reflect judge the primary. Furthermore, We pointed out by many past researches while presenting and implementing an active and environmentally adaptive methodology capable of effectively reducing false detection situations which frequently occur even with the Gaussian Mixture model analytical method which has been considered the best among well-known environmental obstacle reduction methods. Therefore, in this way, the accident was the final decision. Also, environmental factors occur frequently, and with the index finger situations, effectively reducing that can actively and environmentally adaptive techniques through accident final judgment. This implementation of the evaluate performance of the experiment road of 12 incidents in simulated and the jang-hang IC's real-time accident experiment. As a result, the do well detection 93.33%, false alarm 6.7% as showed high reliability.