• 제목/요약/키워드: Back-to-back converter

검색결과 218건 처리시간 0.03초

항공기 시뮬레이터용 조종 반력 시스템 실시간 제어기 개발 (Development of the Real-time Controller for Control Loading System in Aircraft Simulator)

  • 박준호;김태규;박승규;윤태성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1846-1847
    • /
    • 2006
  • In this study, we developed the real-time controller for control loading system (CLS) of aircraft simulator. The CLS is given the forces as inputs: the exerted force by a pilot, which is determined according to the position of the control stick, and the calculated force by the host computer. And then CLS makes the pilot feel the back loading force by supplying the motor drive with the actuator signal. The developed real-time controller for CLS is organized into the five parts which are the position sensing part including a encoder, the A/D converter part for the analog load cell signal, the communication interface part to communicate with the host, the D/A converter for the actuator signal, and the CPU DSP2812 to carry out a control algorithm. We constructed the test control loading system and carried out the experiment with the developed real-time controller. The experimental results showed that the real-time controller generates the back loading forces similar to the desired back loading force graph.

  • PDF

불평형 전압 발생 시 유효전력 조절을 통한 전압형 HVDC의 DC전압 제어 방안 (Control Scheme Using Active Power Regulation for DC Voltage of VSC HVDC Under Unbalanced Voltage)

  • 박상인;허재선;문원식;김두희;김재철
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.232-239
    • /
    • 2015
  • Faced with unbalanced grid operation mode, the high voltage direct current (HVDC) based on voltage source converter (VSC) can be properly controlled by a dual current control scheme. For the modular multilevel converter (MMC) controlling the AC side current is able to limit the arm current which flows along the IGBT of submodule (SM) to rated current. However the limitation of the arm current results in leaving the control range of active power at MMC confined to below the rated capacity. As a result, limiting the arm current causes the problem that the DC side voltage of the HVDC can not be controlled to the reference value since MMC HVDC adjusts the DC side voltage through the active power. In this paper, we propose the algorithm adjusting the active powers of both MMCs to resolve the problem. The back-to-back MMC HVDC applying the algorithm is modeled by PSCAD/EMTDC to verify the algorithm.

시뮬레이터 컨버터에 의한 인버터 성능시험에 관한 연구 (A Study on the Inverter performance test by Simulated Converter)

  • 조정민;함년근;김대균;이상집;김성남;이훈구;한경희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.765-768
    • /
    • 2003
  • In the end of a production line a new built power converter has to undergo a series of stress tests. This can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. The latter is controlled to create some specific load characteristic needed for the test. In this paper a test method is proposed, in which no mechanical equipment is needed. The suggested test stand consists only of a converter to be tested and a simulator converter. Both devices are connected back-to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load.

  • PDF

적응 슬라이딩 모드제어를 통한 PMSG 풍력발전시스템의 MPPT제어 (Mppt control of PMSG wInd power system using adaptive sliding mode control)

  • 정형철;천관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1060-1061
    • /
    • 2015
  • This paper presents the control method of MPPT (Maximum Power Point Tracking) using back-to- back converter. The windturbine system use PMSG(ermanent Magnet Synchronous Generator) system considering low maintenance costs and driving performance at low wind. This paper use the adaptive sliding mode control to the torque control. Proposed method was analyzed mathematically.

  • PDF

Voltage Equalizing of Solar Modules for Shadowing Compensation

  • Jou, Hurng-Liahng;Wu, Kuen-Der;Wu, Jinn-Chang;Chung, Cheng-Huan;Huang, Ding-Feng
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.514-521
    • /
    • 2017
  • This paper proposes a shadowing compensation method for the solar modules of grid-connected photovoltaic generation systems. The shadowing compensator (SC) implemented by the proposed shadowing compensation method is used only for the solar modules that can be shaded by predictable sources of shading. The proposed SC can simplify both the power circuit and the control circuit as well as improve power efficiency and utilizes a voltage equalizer configured by a modified multi-winding fly-back converter. The proposed SC harvests energy from the entire solar cell array to compensate for the shaded sub-modules of the solar cell array, producing near-identical voltages of all shaded and un-shaded sub-modules in the solar cell array. This setup prevents the formation of multiple peaks in the P-V curve under shaded conditions. Hardware prototypes are developed for the SCs implemented by the conventional and modified multi-winding fly-back converters, and their performance is verified through testing. The experimental results show that both SCs can overcome the multiple peaks in the P-V curve. The proposed SC is superior to the SC implemented by the conventional multi-winding fly-back converter.

Direct Power Control Scheme of Improved Command Tracking Capability for PMSG MV Wind turbines

  • Kwon, Gookmin;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.361-362
    • /
    • 2015
  • This paper proposes a Direct Power Control (DPC) scheme of improved command tracking capability for Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) Wind Turbines. Benchmarking is performed based on a neutral point clamped three-level back-to-back type voltage source converter. It is introduced to design the DPC modeling and propose DPC scheme of a three-level NPC (3L-NPC) converter. During the fault condition in wind farms, the proposed control scheme directly controls the generated output power to the command value from the hierarchical wind farm controller. The proposed control scheme is compared with conventional control scheme as respect to loss and thermal analysis. The DPC scheme of improved command tracking capability is confirmed through PLECS simulations. Simulation result shows that proposed control scheme achieves a much shorter transient time in a step response of generated output power. The proposed control scheme makes it possible to provide a good dynamic performance for PMSG MV wind turbine to generate a high quality output power under grid fault condition.

  • PDF

새로운 단계층 Single-Switch PFC 컨버터 (Novel Single-Switch Converter with PFC)

  • 이희승;김봉규;윤재한;서재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1292-1295
    • /
    • 2000
  • In this paper, we proposed a new single-stage single-switch power factor correction(S-4 PFC) converter with output electrical isolation. The configuration of this converter is achieved by combining a fly back circuit and a forward circuit in one power stage. To verify the theoretical analysis of the proposed converter, a design example is given with its Pspice simu-lation and experimental results.

  • PDF

무접점 충전기의 전력단 변압기를 통한 무접점 피드백 제어방식 (Contactless feed-back control method through power stage transformer in non-contact battery charger)

  • 김창균
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.258-261
    • /
    • 2000
  • A non-contact battery charger which transfers energy using magnetic field has a difficulty with a feed-back control due to the interaction between the power and signal processing This paper proposes an effective method which uses auxiliary windings of transformer as signal path and copes with cross-talk using the MOSFET ringing phenomenon and ceramic filter. The power stage is half-bridge series resonant converter. Design procedure and experimental verification are presented.

  • PDF

10kW급 계통연계형 3상 백투백 컨버터 제작 및 실험 (Implementation of 10kW Grid-connected Three-phase Back-to-Back Converter)

  • 이일용;채승우;차한주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.56-57
    • /
    • 2011
  • 본 논문에서는 10kW급 3상 백투백 컨버터에 필요한 여러가지 제어 기술들을 살펴보고 시뮬레이션을 통해 제어 알고리즘의 타당성을 분석하며, 실제 하드웨어의 구성 및 계통연계 실험을 통해 입, 출력 전압, 전류 등 파형을 관찰하여 3상 백투백 컨버터의 타당성과 적정성을 알아본다.

  • PDF

산청양수 디지털 여자시스템 개발 (Development of Digital Excitation System for San-cheong Pumped Sorage Power Plant)

  • 류호선;임익헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.956-957
    • /
    • 2006
  • KEPRI developed digital excitation system for San-Cheong pumped storage power plant. This is the very complicated system because of operation connected with SFC(Static Frequency Converter). Many operation modes(stating, regeneration, back to back, line charging, gird connection mode etc) during the commissioning were successfully tested at san-Cheong #2.

  • PDF