• 제목/요약/키워드: BO - PET

검색결과 50건 처리시간 0.025초

Polyester Film Laminating Technology for Chip Condenser

  • Lee, Yun Dai;Son, Yang Soo;Ahn, Joong Geol
    • Corrosion Science and Technology
    • /
    • 제3권4호
    • /
    • pp.172-177
    • /
    • 2004
  • Biaxially oriented polyethylene terephthalate copolymer(BO - PET)film laminated aluminiums have been applied for chip condenser case. The BO PET film is characterized by high molecular which gives high corrosion resistance, good adhesion and high heat resistance. The higher orientation lowers formability of the film. So, optimum orientation has to be controlled during the laminating process. And to confirm the adhesion between BO PET and aluminium and to guarantee the formability of PET laminated aluminums, we have controlled the chromium oxides weight on the aluminium and laminating condition ( laminating temperature, soaking temperature and lag time after nip roll and quenching conditions) This paper discusses the effect of the laminating conditions on the formability of laminated aluminums. As results, it is clear that the orientation of the BO PET film decreased with an increase in the strip temperature. When the film temperature is over the melting point of the film, its orientation drastically decreased.

Respiratory Motion Correction on PET Images Based on 3D Convolutional Neural Network

  • Hou, Yibo;He, Jianfeng;She, Bo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권7호
    • /
    • pp.2191-2208
    • /
    • 2022
  • Motion blur in PET (Positron emission tomography) images induced by respiratory motion will reduce the quality of imaging. Although exiting methods have positive performance for respiratory motion correction in medical practice, there are still many aspects that can be improved. In this paper, an improved 3D unsupervised framework, Res-Voxel based on U-Net network was proposed for the motion correction. The Res-Voxel with multiple residual structure may improve the ability of predicting deformation field, and use a smaller convolution kernel to reduce the parameters of the model and decrease the amount of computation required. The proposed is tested on the simulated PET imaging data and the clinical data. Experimental results demonstrate that the proposed achieved Dice indices 93.81%, 81.75% and 75.10% on the simulated geometric phantom data, voxel phantom data and the clinical data respectively. It is demonstrated that the proposed method can improve the registration and correction performance of PET image.

PET 세섬도 Downproof 직물개발에 관한 연구 (A Study on Downproof fabric development using low denier PET)

  • 심승범;윤원보;최광석
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2008년도 제39차 학술발표회
    • /
    • pp.145-146
    • /
    • 2008
  • This is studies about light and thin PET fabric having downproof properties using low denier filament yarn. We study how the manufacturing fabric effect on downproof properties according to conditions of low denier yarn, fabricataion, and dyeing and finishing.

  • PDF

PET Fabric/Poly(3,4-ethylenedioxythiophene) Composite as Polymer Electrode in Redox Supercapacitor

  • Cho, Seung-Hyun;Joo, Jin-Soo;Jung, Bo-Ram;Ha, Tae-Min;Lee, Jun-Young
    • Macromolecular Research
    • /
    • 제17권10호
    • /
    • pp.746-749
    • /
    • 2009
  • Poly(ethylene terephthalate) (PET) fabric/poly(3,4-ethylenedioxythiophene) (PEDOT) composite with stable and high electrochemical activity was fabricated by chemical and electrochemical polymerization of 3,4-ethylenedioxythiophene (EDOT) on a PET fabric in sequence. Effects of polymerization conditions on the following characteristics of the composite were studied: electrical conductivity and surface morphology. The electrochemical properties were also investigated by cyclic voltammetry and cyclic charge/discharge experiments. The specific volume resistivity, electrical conductivity and specific discharge capacitance of the composite were 0.034 $\Omega-cm$ and 25 S/cm, and 54.5 F/g, respectively.

PET 감량폐약으로부터 발생되는 crude TPA sludge를 원료로 한 DMT 합성에 관한 연구 (A Study on DMT Synthesis Using Crude TPA Sludge Generated from PET Alkaline Waste Water as Raw Materials)

  • Cho, Hwan;Kim, Jong Bo;Jeong, Hee Cheon;Jeon, Byung Dae
    • 한국염색가공학회지
    • /
    • 제7권2호
    • /
    • pp.9-16
    • /
    • 1995
  • When alkaline waste water of PET fabric is treated with sulfuric acid, undegradable material, crude TPA sludge is generated, so that treatment has a serious problem. The result of DMT synthesis using crude TPA sludge generated from PET alkaline waste water were as follows: 1. When crude TPA generated from alkaline waste water is reactioned with methanol under catalyst of sulfuric acid, pure DMT can be obtained. 2. In DMT synthesis from crude TPA, addition of copper sulfate can increase yield, and increasing the amount of sulfuric acid can shorten reaction time.

  • PDF

Diagnostic Value of 18F-FDG PET/CT in Comparison to Bone Scintigraphy, CT and 18F-FDG PET for the Detection of Bone Metastasis

  • Liu, Ning-Bo;Zhu, Lei;Li, Ming-Huan;Sun, Xiao-Rong;Hu, Man;Huo, Zong-Wei;Xu, Wen-Gui;Yu, Jin-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권6호
    • /
    • pp.3647-3652
    • /
    • 2013
  • Purpose: To evaluate the diagnostic value of $^{18}F$-FDG PET/CT for detection of bone metastasis in comparison with the efficacies of $^{18}F$-FDG PET/CT, CT, $^{18}F$-FDG PET and conventional planar bone scintigraphy in a series of cancer patients. Methods: Five hundred and thirty patients who underwent both $^{18}F$-FDG PET/CT and bone scintigraphy within 1 month were retrospectively analyzed. The skeletal system was classified into 10 anatomic segments and interpreted blindly and separately. For each modality, the sensitivity, specificity, accuracy, PPV and NPV were calculated and the results were statistically analyzed. Results: Bone metastases were confirmed in 117 patients with 459 positive segments. On patient-based analysis, the sensitivity, specificity, accuracy, PPV and NPV of $^{18}F$-FDG PET/CT were significantly higher than bone scintigraphy, CT and $^{18}F$-FDG PET (P<0.05). On segment-based analysis, the sensitivity of CT, bone scintigraphy, $^{18}F$-FDG PET and $^{18}F$-FDG PET/CT were 70.4%, 89.5%, 89.1% and 97.8%, respectively (P<0.05, compared with $^{18}F$-FDG PET/CT). The overall specificity and accuracy of the four modalities were 89.1%, 91.8%, 90.3%, 98.2% and 90.3%, 90.9%, 89.8%, 98.0%, respectively (P<0.05, compared with $^{18}F$-FDG PET/CT). The PPV and NPV were 89.8%, 87.6%, 85.6%, 97.2% and 85.6%, 93.2%, 92.8%, 98.6%, respectively. Three hundred and twelve lesions or segments were presented as lytic or sclerotic changes on CT images at the corresponding sites of increased $^{18}F$-FDG uptake. In lytic or mixed lesions, the sensitivity of $^{18}F$-FDG PET/CT and $^{18}F$-FDG PET were better than bone scintigraphy, while in osteoblastic lesions bone scintigraphy had a similar performance with $^{18}F$-FDG PET/CT but better than $^{18}F$-FDG PET alone. Conclusion: Our data allow the conclusion that $^{18}F$-FDG PET/CT is superior to planar bone scintigraphy, CT or $^{18}F$-FDG PET in detecting bone metastasis. $^{18}F$-FDG PET/CT may enhance our diagnosis of tumor bone metastasis and provide more information for cancer treatment.

68Ga-BAPEN 소동물 PET영상 연구 (Small Animal PET Imaging Study of 68Ga-BAPEN)

  • 김지후;이재성;양보연;김수진;김중현;정재민;이동수
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.172-177
    • /
    • 2011
  • 본 연구에서는 소동물의 심근에서 $^{68}Ga$-BAPEN PET 영상분석을 통해 심혈 영상 추적자로서의 적용가능성을 보고자 하였다. 소동물용 PET/CT에서 쥐 9마리를 대상으로 120분간의 $^{68}Ga$-BAPEN PET/CT 스캔을 시행하였다. 특별히 킷트를 통해 간편하고 저비용으로 $^{68}Ga$-BAPEN을 합성이 가능하였다. PET 영상은 쥐의 몸통부분에서 $^{68}Ga$-BAPEN의 생체 동적분포를 나타낸다. $^{68}Ga$-BAPEN PET 영상은 처음 수분간 대동맥과 간에서의 섭취가 나타났고 점차 심근에서의 섭취가 이루어졌다. 관심영역은 좌심근, 심혈, 폐, 간에 그렸고 시간-방사능 곡선을 얻었다. 시간-방사능 곡선에서 $^{68}Ga$-BAPEN이 쥐 심근에 잘 결합하는 것을 확인 할 수 있었다. 정확한 약동학적 파라미터 도출을 위한 최소 PET 스캔시간은 타장 기와의 영상 대조도가 일정비에 이르는 주사 후 60분이 적합하였다. 이때 심근의 섭취를 심혈, 간, 폐에서의 섭취로 나누어 얻은 영상 대조도는 각각 1.66, 0.60, 2.82였다. 결론적으로 $^{68}Ga$-BAPEN은 심근 혈류 질환을 진단하기 위한 추적자로서 적합하며 지속적인 연구가 이루어진다면 임상에서의 진단활용에 도움이 될 것이라 예상된다.

반려동물병원의 고객만족경영 성공요인에 관한 연구 (Critical Factors Affecting Successful Client Satisfaction Management of Companion Animal Hospital)

  • 백충기;신철호;김보영
    • 한국임상수의학회지
    • /
    • 제29권1호
    • /
    • pp.49-57
    • /
    • 2012
  • Success of any business solely is dependant on how to satisfy clients in healthcare-related industry. In the short history of Korea pet-care industry, there were not many guidelines on client satisfaction management of companion animal hospitals. The studies on many pet healthcare facilities were conducted based on their cost-benefits and the advantages of medical operation within special features of the traditional hospital management system. However the companion animal hospitals recently need to improve the service quality and client closed communication in keen competition on pet healthcare market. This study explores client satisfaction management could be the new issue of the veterinary hospital business. And it finally suggests of the critical factors affecting successful client satisfaction management of companion animal hospital based on the eight case studies.

저온공정에서 산화아연의 3차원 물결 구조 형성에 따른 PET 기판 소자의 제작 및 연구 (Production and study of the PET substrate based on solar cell in accordance with the three-dimensional wavy structure formed of zinc oxide at a low temperature process.)

  • 정재훈;서보열;임동찬
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2014년도 추계학술대회 논문집
    • /
    • pp.152-152
    • /
    • 2014
  • 본 연구에서는 핫플레이트를 이용한 간단한 산화아연 박막의 열처리를 통해 역구조 유기 태양전지에서의 광전환 효율증가를 소개한다. 유기태양전지는 환경오염에 따른 신 재생에너지의 필요성이 대두되면서, 중요한 주제가 되고 있다. 본 연구에서는 3차원 물결구조의 산화아연 박막을 핫플레이트를 이용하여, $180^{\circ}C$ 에서 산화아연의 3차원 물결구조의 형성에 성공하였다. 그리고 구조적 측면 뿐만 아니라, 아연 용액에 포함된 질소로 인해 산화아연의 밴드갭이 조절되어 유기태양전지의 효율이 증가했음을 확인 하였다. 또한 본 연구의 공정을 이용하여 PET 유연기판으로의 적용이 가능하다는 것을 확인 하였다.

  • PDF

금속성 치아충전물이 PET/CT영상이 미치는 영향 (The Effect of Metallic Dental Implant on Positron Emission Tomography Computed Tomography Image)

  • 김기진;배석환;한상현;유세종;이보우
    • 디지털융복합연구
    • /
    • 제10권2호
    • /
    • pp.243-247
    • /
    • 2012
  • 금속성 치아충전물이 있을 때 PET/CT검사를 시행하면 CT영상에서 선속경화인공음영이 발생한다. CT영상에 발생되는 인공음영에 의해 PET영상에 영향을 미칠 수 있다. 두경부종양이 있는 환자가 치과용 충전물이 있을 경우 CT영상에서 발생하는 선속경화인공음영에 의해 PET영상 및 SUV값에 변화를 줄 수 있다. 따라서 본 연구는 금속성치아충전물에 의한 HU 값의 변화에 따른 SUV값을 정량적으로 측정하여 임상적용에 있어 적절성을 평가 하였다. 연구대상은 2011년 8월에 PET/CT검사를 실시한 환자 47명이었다. 분석을 위해 CT와 PET영상에 2개의 ROI를 그려 이용하였다. 실험결과 충전물이 있을 경우 HU값과 SUV값이 증가 하였고 통계적으로도 유의한 차이를 보였다.(P<0.01) 이 증가 정도는 금속성 치아충전물이 없는 환자의 경우보다 큰 변화는 아니었지만 두경부 종양이 있을 경우 암의 진단시 과대평가가 될 수 있는 가능성이 충분하다. 따라서 임상에서 두경부 종양이 있는 환자를 대상으로 PET/CT 검사를 시행할 경우 판독상의 오류를 범하지 않도록 여러 물리학적, 생물학적인 부분에 대하여 고려를 해야 할 것이다.