• Title/Summary/Keyword: BO - PET

Search Result 51, Processing Time 0.026 seconds

Polyester Film Laminating Technology for Chip Condenser

  • Lee, Yun Dai;Son, Yang Soo;Ahn, Joong Geol
    • Corrosion Science and Technology
    • /
    • v.3 no.4
    • /
    • pp.172-177
    • /
    • 2004
  • Biaxially oriented polyethylene terephthalate copolymer(BO - PET)film laminated aluminiums have been applied for chip condenser case. The BO PET film is characterized by high molecular which gives high corrosion resistance, good adhesion and high heat resistance. The higher orientation lowers formability of the film. So, optimum orientation has to be controlled during the laminating process. And to confirm the adhesion between BO PET and aluminium and to guarantee the formability of PET laminated aluminums, we have controlled the chromium oxides weight on the aluminium and laminating condition ( laminating temperature, soaking temperature and lag time after nip roll and quenching conditions) This paper discusses the effect of the laminating conditions on the formability of laminated aluminums. As results, it is clear that the orientation of the BO PET film decreased with an increase in the strip temperature. When the film temperature is over the melting point of the film, its orientation drastically decreased.

Respiratory Motion Correction on PET Images Based on 3D Convolutional Neural Network

  • Hou, Yibo;He, Jianfeng;She, Bo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.7
    • /
    • pp.2191-2208
    • /
    • 2022
  • Motion blur in PET (Positron emission tomography) images induced by respiratory motion will reduce the quality of imaging. Although exiting methods have positive performance for respiratory motion correction in medical practice, there are still many aspects that can be improved. In this paper, an improved 3D unsupervised framework, Res-Voxel based on U-Net network was proposed for the motion correction. The Res-Voxel with multiple residual structure may improve the ability of predicting deformation field, and use a smaller convolution kernel to reduce the parameters of the model and decrease the amount of computation required. The proposed is tested on the simulated PET imaging data and the clinical data. Experimental results demonstrate that the proposed achieved Dice indices 93.81%, 81.75% and 75.10% on the simulated geometric phantom data, voxel phantom data and the clinical data respectively. It is demonstrated that the proposed method can improve the registration and correction performance of PET image.

A Study on Downproof fabric development using low denier PET (PET 세섬도 Downproof 직물개발에 관한 연구)

  • Sim, Seung-Beom;Yun, Won-Bo;Choe, Gwang-Seok
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2008.10a
    • /
    • pp.145-146
    • /
    • 2008
  • This is studies about light and thin PET fabric having downproof properties using low denier filament yarn. We study how the manufacturing fabric effect on downproof properties according to conditions of low denier yarn, fabricataion, and dyeing and finishing.

  • PDF

PET Fabric/Poly(3,4-ethylenedioxythiophene) Composite as Polymer Electrode in Redox Supercapacitor

  • Cho, Seung-Hyun;Joo, Jin-Soo;Jung, Bo-Ram;Ha, Tae-Min;Lee, Jun-Young
    • Macromolecular Research
    • /
    • v.17 no.10
    • /
    • pp.746-749
    • /
    • 2009
  • Poly(ethylene terephthalate) (PET) fabric/poly(3,4-ethylenedioxythiophene) (PEDOT) composite with stable and high electrochemical activity was fabricated by chemical and electrochemical polymerization of 3,4-ethylenedioxythiophene (EDOT) on a PET fabric in sequence. Effects of polymerization conditions on the following characteristics of the composite were studied: electrical conductivity and surface morphology. The electrochemical properties were also investigated by cyclic voltammetry and cyclic charge/discharge experiments. The specific volume resistivity, electrical conductivity and specific discharge capacitance of the composite were 0.034 $\Omega-cm$ and 25 S/cm, and 54.5 F/g, respectively.

A Study on DMT Synthesis Using Crude TPA Sludge Generated from PET Alkaline Waste Water as Raw Materials (PET 감량폐약으로부터 발생되는 crude TPA sludge를 원료로 한 DMT 합성에 관한 연구)

  • Cho, Hwan;Kim, Jong Bo;Jeong, Hee Cheon;Jeon, Byung Dae
    • Textile Coloration and Finishing
    • /
    • v.7 no.2
    • /
    • pp.9-16
    • /
    • 1995
  • When alkaline waste water of PET fabric is treated with sulfuric acid, undegradable material, crude TPA sludge is generated, so that treatment has a serious problem. The result of DMT synthesis using crude TPA sludge generated from PET alkaline waste water were as follows: 1. When crude TPA generated from alkaline waste water is reactioned with methanol under catalyst of sulfuric acid, pure DMT can be obtained. 2. In DMT synthesis from crude TPA, addition of copper sulfate can increase yield, and increasing the amount of sulfuric acid can shorten reaction time.

  • PDF

Diagnostic Value of 18F-FDG PET/CT in Comparison to Bone Scintigraphy, CT and 18F-FDG PET for the Detection of Bone Metastasis

  • Liu, Ning-Bo;Zhu, Lei;Li, Ming-Huan;Sun, Xiao-Rong;Hu, Man;Huo, Zong-Wei;Xu, Wen-Gui;Yu, Jin-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3647-3652
    • /
    • 2013
  • Purpose: To evaluate the diagnostic value of $^{18}F$-FDG PET/CT for detection of bone metastasis in comparison with the efficacies of $^{18}F$-FDG PET/CT, CT, $^{18}F$-FDG PET and conventional planar bone scintigraphy in a series of cancer patients. Methods: Five hundred and thirty patients who underwent both $^{18}F$-FDG PET/CT and bone scintigraphy within 1 month were retrospectively analyzed. The skeletal system was classified into 10 anatomic segments and interpreted blindly and separately. For each modality, the sensitivity, specificity, accuracy, PPV and NPV were calculated and the results were statistically analyzed. Results: Bone metastases were confirmed in 117 patients with 459 positive segments. On patient-based analysis, the sensitivity, specificity, accuracy, PPV and NPV of $^{18}F$-FDG PET/CT were significantly higher than bone scintigraphy, CT and $^{18}F$-FDG PET (P<0.05). On segment-based analysis, the sensitivity of CT, bone scintigraphy, $^{18}F$-FDG PET and $^{18}F$-FDG PET/CT were 70.4%, 89.5%, 89.1% and 97.8%, respectively (P<0.05, compared with $^{18}F$-FDG PET/CT). The overall specificity and accuracy of the four modalities were 89.1%, 91.8%, 90.3%, 98.2% and 90.3%, 90.9%, 89.8%, 98.0%, respectively (P<0.05, compared with $^{18}F$-FDG PET/CT). The PPV and NPV were 89.8%, 87.6%, 85.6%, 97.2% and 85.6%, 93.2%, 92.8%, 98.6%, respectively. Three hundred and twelve lesions or segments were presented as lytic or sclerotic changes on CT images at the corresponding sites of increased $^{18}F$-FDG uptake. In lytic or mixed lesions, the sensitivity of $^{18}F$-FDG PET/CT and $^{18}F$-FDG PET were better than bone scintigraphy, while in osteoblastic lesions bone scintigraphy had a similar performance with $^{18}F$-FDG PET/CT but better than $^{18}F$-FDG PET alone. Conclusion: Our data allow the conclusion that $^{18}F$-FDG PET/CT is superior to planar bone scintigraphy, CT or $^{18}F$-FDG PET in detecting bone metastasis. $^{18}F$-FDG PET/CT may enhance our diagnosis of tumor bone metastasis and provide more information for cancer treatment.

Small Animal PET Imaging Study of 68Ga-BAPEN (68Ga-BAPEN 소동물 PET영상 연구)

  • Kim, Ji-Who;Lee, Jae-Sung;Yang, Bo-Yeun;Kim, Su-Jin;Kim, Joong-Hyun;Jeong, Jae-Min;Lee, Dong-Soo
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.172-177
    • /
    • 2011
  • The purpose of this study was to analyze $^{68}Ga$-BAPEN dynamic PET image in rat myocardium to evaluate potential of this radiotracer as a perfusion imaging agent. Animal PET/CT scan was done in 9 rats during 120 minutes. Especially we synthesized $^{68}Ga$-BAPEN with kit which is simple and low cost method. PET images showed the in vivo dynamic distribution of $^{68}Ga$-BAPEN in the chest region of rats. Initially $^{68}Ga$-BAPEN PET images showed aorta and liver activities and a few minutes later, $^{68}Ga$-BAPEN moved to myocardium. Regions of interest were drawn on myocardium, liver, lung and blood pool. Time-activity curves showed significant uptake of $^{68}Ga$-BAPEN in myocardium. The contrast ratios of myocardial to blood pool, lung and liver at 60 minutes after injection were 1.66, 2.82 and 0.60. To estimate accurate kinetic parameters, 60 minutes after injection was required to PET scan as myocardium image contrast ratios reached to constant values. As a result, $^{68}Ga$-BAPEN would be suitable radiotracer for PET which can applied to diagnosis of myocardial perfusion diseases after further preclinical and clinical investigations.

Critical Factors Affecting Successful Client Satisfaction Management of Companion Animal Hospital (반려동물병원의 고객만족경영 성공요인에 관한 연구)

  • Baik, Choong-Ki;Shin, Cheol-Ho;Kim, Bo-Young
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.49-57
    • /
    • 2012
  • Success of any business solely is dependant on how to satisfy clients in healthcare-related industry. In the short history of Korea pet-care industry, there were not many guidelines on client satisfaction management of companion animal hospitals. The studies on many pet healthcare facilities were conducted based on their cost-benefits and the advantages of medical operation within special features of the traditional hospital management system. However the companion animal hospitals recently need to improve the service quality and client closed communication in keen competition on pet healthcare market. This study explores client satisfaction management could be the new issue of the veterinary hospital business. And it finally suggests of the critical factors affecting successful client satisfaction management of companion animal hospital based on the eight case studies.

Production and study of the PET substrate based on solar cell in accordance with the three-dimensional wavy structure formed of zinc oxide at a low temperature process. (저온공정에서 산화아연의 3차원 물결 구조 형성에 따른 PET 기판 소자의 제작 및 연구)

  • Jeong, Jae-Hun;Seo, Bo-Yeol;Im, Dong-Chan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.152-152
    • /
    • 2014
  • 본 연구에서는 핫플레이트를 이용한 간단한 산화아연 박막의 열처리를 통해 역구조 유기 태양전지에서의 광전환 효율증가를 소개한다. 유기태양전지는 환경오염에 따른 신 재생에너지의 필요성이 대두되면서, 중요한 주제가 되고 있다. 본 연구에서는 3차원 물결구조의 산화아연 박막을 핫플레이트를 이용하여, $180^{\circ}C$ 에서 산화아연의 3차원 물결구조의 형성에 성공하였다. 그리고 구조적 측면 뿐만 아니라, 아연 용액에 포함된 질소로 인해 산화아연의 밴드갭이 조절되어 유기태양전지의 효율이 증가했음을 확인 하였다. 또한 본 연구의 공정을 이용하여 PET 유연기판으로의 적용이 가능하다는 것을 확인 하였다.

  • PDF

The Effect of Metallic Dental Implant on Positron Emission Tomography Computed Tomography Image (금속성 치아충전물이 PET/CT영상이 미치는 영향)

  • Kim, Ki-Jin;Bae, Seok-Hwan;Han, Sang-Hyun;Yu, Se-Jong;Lee, Bo-Woo
    • Journal of Digital Convergence
    • /
    • v.10 no.2
    • /
    • pp.243-247
    • /
    • 2012
  • Beam hardening artifact happens in the CT image. when a PET/CT is conducted while there is a metallic dental implant. The artifact appears in the CT image can affect the PET image. When the patient with head and neck cancer has a metallic dental implant, Beam hardening artifact which was taken in th CT image can change the PET image and SUV value. Therefore, by Quantitative measure of the SUV according to the change in HU by the metallic dental implant, the appropriacy in the clinical application was assessed. The records of 47 patients with PET/CT August 2011. For the analysis, 2 region of interest were defined in area where CT and PET image. As a result of the experiment, if there in an implant, the HU and the SUV increased and there existed a statistically significant difference(p<0.01). Although this level of increase was not large compared with that in the patient who have no metallic dental implant, when a person has head and neck cancer, it is even more likely to be overestimated when diagnosing the cancer. When conducting PET/CT for the patient who have head and neck cancer, the physical biological parts should be considered in order not to make an error in decoding.