• 제목/요약/키워드: BIPV(Building Integrated PV)

검색결과 92건 처리시간 0.021초

냉난방부하 절감을 위한 경사형 이중외피시스템의 성능연구 (A study on the efficiency of sloped type Double-skin System for the Curtailment of Heating/Cooling Load)

  • 안형준;김영탁;최창호;이현우
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.77-87
    • /
    • 2004
  • BIPV or double skin applied to the surface of the building, power and thermal load cannot both be increased. In the case of BIPV, because it is applied to the facade, incident solar energy decreases and efficiency drops off. The system in this paper complements these disadvantages and aims to decrease the heating & cooling load by transforming solar energy to electronic and thermal energy. The research in this paper is about the applicability of the clear PV attached double-skin system. And the PV electronic generation and the factors that affect the heating & cooling load such as the daily radiation, sun shading ratio, heating & cooling load, daylight luminance and glare distributions in the building are simulated.

건물 외벽 환경을 고려한 BIPV SU(string unit) module에 관한 연구 (A Study for BIPV string unit module)

  • 이길송;김병만;신현우;윤종호;유권종;강기환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.154-157
    • /
    • 2008
  • In korea, PV business has been growing fast since 2000. There are many ways to build PV module Among them, BIPV system(BIPV : building integrated system) using PV modules as external wall has been carried out research on and invested much. I suggest another way to apply the BIPV system BIPV SU(string unit) module is easier and faster to be installed and more economical than other BIPV module. In this paper. I will show how to make, and how to install this BIPV SU module.

  • PDF

후면 유리 종류에 따른 투과형 태양광발전모듈의 열 및 광 특성 분석 (Analysis of Thermal and Optical Characteristic of Semi-transparent Module according to Various Types of the Backside Glass)

  • 박경은;강기환;김현일;김경수;유권종;김준태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.263-268
    • /
    • 2008
  • Building Integrated PV(BIPV) is one of the best fascinating PV application technologies. To apply PV module in building, various factors should be reflected such as installation position, shading, temperature, and so on. Especially a temperature should be considered, for it affects both electrical efficiency of a PV module and heating/cooling load in a building. This study investigates a semitransparent PV module that is designed as finished material for windows. Therefore it needs to considerate about the optical characteristics of the transparent module. It reports the effect of thermal and optical characteristics of the PV module on generation performance. The study was performed by measuring sun spectrum and luminance through the PV modules and by monitoring the temperature and experiment. The results showed that 1 degree temperature rise reduced about 0.48% of output power.

  • PDF

주택지붕용 2kWp BIPV시스템의 성능 실험 및 전기 부하 감당에 관한 연구 (The Performance and Energy Saving Effect of a 2kWp Roof-Integrated Photovoltaic System)

  • 이강록;오명택;박경은;김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.13-19
    • /
    • 2006
  • The efficiency of building-integrated photovoltaic(BIPV) system is mainly determined by solar radiation and the temperature of PV modules. The performance of BIPV systems is reported to be different from that of conventional PV systems installed in the open-air. This paper presents the relationship of solar radiation and electricity generation from a 2kWp roof-integrated PV system that is applied as building elements on an experimental house, and the energy saving effect of the BIPV system for a typical house. For the performance evaluation of the BIPV system, it produced a regression equation with measured data for winter days. The regression equation showed that a comparison of the measured electricity generation and the predicted electricity generation of the BIPV system were meaningful. It showed that an annual electricity generation of the system appeared to cover around 52% of an annual electricity consumption of a typical domestic house with the floor area of $96m^2$.

BIPV 시스템에서의 모듈 종류에 따른 건축적 특성 연구 - 채광형 시스템을 중심으로 - (A Study of the Architectural Characteristic Depending upon the Module in the BIPV System)

  • 이응직;이충식
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.196-202
    • /
    • 2008
  • Effective climate protection is a most important tasks of our time. The BIPV is one of the most interesting and promisingly possibilities of an active use of solar energy at the building. In this study it was analyzed by the case study the function of the requirement of the BIPV-module as building material and this architectural characteristic according to the kind of the module. Therefore the goal of this study is to get securing the application information of BIPV as windowpane. BIPV modules are manufactured in the form of G/G. In the case of the crystal type the Transparent and the light Transmission is to be adjusted by the spacer attitude of the cell. Although this type could not be optimal for light effect of indoors because of the inequality of shade, the moving shade play makes a dramatic Roomimage by the run of sun. The application of this type would be for canopy, window or roof in the corridor or resounds. With amorphous the type it is to be manufactured simply largely laminar, and thus that will shorten building process. There is a relatively good economy to use and to the window system easily. After the production technology is easy the transparency of the modules to adjust, and the module shows to a high degree constant characteristics of light permeability and transparency. Without mottle of module shade is good the use for the window or roof glazing of office, library, classroom, etc. to adapt. The BIPV modules took generally speaking a function as building material to the daylight use, shading, isolation and also to the sight. That means that BIPV modules have as multifunctional system to sustainable architecture good successes and they are at the same time as Design element for architecture effectively.

  • PDF

제로에너지 건축물 확산을 위한 건물 일체형 태양광 적용방안 연구 (A Study on the Application of BIPV for the Spread of Zero Energy Building)

  • 박승준;전현우;이승준;오충현
    • 디지털융복합연구
    • /
    • 제19권9호
    • /
    • pp.189-199
    • /
    • 2021
  • 국내 제로에너지건축물 의무화를 대응하기 위해서 신재생에너지 자립률을 높이려면 고층 건물일수록 대지면적에 한계가 있고 옥상에 PV모듈을 설치하는 것만으로는 부족하다. 따라서 제로에너지건축물을 실현할 수 있는 핵심 에너지원으로 BIPV(Building Integrated PhotoVoltaic, 이하 BIPV)는 가장 주목받는 산업이다. 이에 본 연구는 BIPV 산업의 올바른 방향 제시와 활성화룰 위해 설계자, 시공자, 제품 제조자, 유지관리자 등 경력 10년 이상 전문가를 대상으로 BIPV 산업의 문제점을 자율 토론 방식으로 설문 조사를 시행하였다. BIPV 적용의 산업적 문제점으로는 제품 인증을 위한 표준 및 인증기준의 범위 확대, 다품종 소량 생산의 현황을 고려한 인증범위 개선, 컬러 모듈과 루버 모듈 및 지붕형 제품을 수용할 수 있는 표준 개정 필요성, 인증제품 의무화를 통한 외산 모듈의 국내 유입 차단의 필요성, BIPV 제품 정보 획득의 어려움, BIPV의 건축 적용 부위 등에 대한 정확한 가이드라인으로 참여자간의 혼란 야기 방지 필요, BIPV 정의의 명확한 정립과 지원 정책이나 제도가 부족하다는 문제들을 도출하였다. 이에 본 연구는 산업계에서 바라보는 시장 변화와 영향을 주고 있는 요소, 경쟁력 강화를 위한 필요한 개선 사항을 바탕으로 대응 방안과 방향성을 제시하고 제안하는데 그 목적이 있다.

태양광발전시스템의 건물 적용에 대한 인식 조사 연구 (A Survey of the Recognition of Photovoltaic System for Building Application)

  • 이충국;유권종;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제23권1호
    • /
    • pp.17-28
    • /
    • 2003
  • This study aims to investigate and analyze the overall recognition of the photovoltaic system for the application of BIPV(Building Integrated Photovoltaic) in Korea. For this purpose, a survey was carried on through questionnaires answered by 6 groups of experts such as construction engineers, registered architects, mechanical engineers, electrical engineers, university or college professors, and others who are ranked high in their companies or universities or colleges and who mostly seem to be eager to participate in the development of the PV system and to make a business of the system. The results of the survey are as follows: 1. About 95% of those experts who answered the questionnaire have known about renewable energy, and 93% of them are interested in solar energy as alternative energy 2. Host experts have a lot of information on the solar energy system, but have scanty information on the PV system. 3. The experts in the educational and research field have researched for the reasonable period of the participation in the development of the PV system and the period of making a business of the system. They judge that companies in the mechanical and electrical field will participate in the development of the PV system and will make a business of the system in 5 years. 4. The experts have thought that the PV system is designed not for economy but for the environment of the earth and that PV system technology in Korea is much lower than that in the advanced countries. 5. The experts hesitate to participate in the development of the PV system and to make a business of the system because they have little confidence in the economy of the PV system now and because they have thought that they will bear a great financial burden of construction cost 6. The experts judge that it is most desirable to apply the PV system to the rooftops of buildings. And they are greatly interested in the BIPV.

스팬드럴용 투광형 결정계 BIPV창호의 후면단열 조건에 따른 연간 온도 및 발전성능 분석 연구 (Annual Base Performance Evaluation on Cell Temperature and Power Generation of c-Si Transparent Spandrel BIPV Module depending on the Backside Insulation Level)

  • 윤종호;오명환;강기환;이재범
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.24-33
    • /
    • 2012
  • Recently, finishing materials at spandrel area, a part of curtain-wall system, are gradually forced to improve thermal insulation performance in order to enhance the building energy efficiency. Also, Building Integrated Photovoltaics(BIPV) systems have been installed in the exterior side of the spandrel area, which is generally composed of windows. Those BIPVs aim to achieve high building energy efficiency and supply the electricity to building. However, if transparent BIPV module is combined with high insulated spandrel, it would reduce the PV efficiency for two major reasons. First, temperature in the air space, located between window layer and finishing layer of the spandrel area, can significantly increase by solar heat gain, because the space has a few air density relative to other spaces in building. Secondly, PV has a characteristics of decreased Voltage(Voc and Vmp) with the increased temperature on the PV cell. For these reasons, this research analyzed a direct interrelation between PV Cell temperature and electricity generation performance under different insulation conditions in the spandrel area. The different insulation conditions under consideration are 1) high insulated spandrel(HIS) 2) low insulated spandrel(LIS) 3) PV stand alone on the ground(SAG). As a result, in case of 1) HIS, PV temperature was increased and thus electricity generation efficiency was decreased more than other cases. To be specific, each cases' maximum temperature indicated that 1) HIS is $83.8^{\circ}C$, 2) LIS is $74.2^{\circ}C$, and 3) SAG is $66.3^{\circ}C$. Also, each cases yield electricity generation like that 1) HIS is 913.3kWh/kWp, 2) LIS is 942.8kWh/kWp, and 3) SAG is 981.3kWh/kWp. These result showed that it is needed for us to seek to the way how the PV Cell temperature would be decreased.

Building Integrated Photovoltaics: Technical and Aesthetic Prospects

  • Polgampola Chamani Madara;Hasnain Yousuf;Muhammad Aleem Zahid;Suresh Kumar Dhungel;Youngkuk Kim;Junsin Yi
    • 한국전기전자재료학회논문지
    • /
    • 제37권2호
    • /
    • pp.154-163
    • /
    • 2024
  • The energy demand in the world is expected to exceed 740 million TJ by 2040 and our dependence on fossil fuels needs to be switched to sustainable and renewable energy sources like solar energy. Building Integrated Photovoltaic (BIPV) is one of the best approaches to extracting solar energy. There are more than 200 BIPV products in the market currently but when it comes to integrating these products into the technical aspects such as buildings' structural integrity, thermal, daylight retainment and aesthetic prospects to be considered. The share of BIPV integration potential of different building types in the world of residential, agricultural, industrial, commercial and other buildings account for 66%, 4.8%, 8.1%, 19.9%, and 1.2% accordingly. Many solar technologies developed to achieve architectural requirements, but the main problem is the trade-off between efficiency and aesthetic appeal, which is less than 10% in coloured and transparent solar modules. This paper discusses the different applications of solar photovoltaics (PV) in building architecture, technical requirements, and different module technologies. The article provides a comprehensive guide for researchers and designers working on the development of BIPV integrations.

12kW급 건물일체형 태양광발전시스템 사례분석 (Case Study on 12kW Building Integrated Photovoltaic System)

  • 박경은;강기환;김현일;소정훈;유권종;김준태;이길송
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.18-23
    • /
    • 2009
  • We intend to describe a 12kW building-integrated photovoltaic system which was applied into the south wall of a new building. This study showed the results that were appeared from describing the PV module manufacture and installation process, and performing generation performance analysis of BIPV system. From the result we confirmed that the generation performance of the BIPV system was changed by season. The performance ratio(PR) was about 83.6% in winter and it means that performance of this BIPV system was so good in that season. On the other hand, the PR in summer was about 75.0% dropped about 8%. It was believed that the change was influenced by the reduction of solar radiation irradiated into the PV modules by installation position and rainy spell in summer. And we also confirmed that low irradiation condition is cause of the additional loss in the total PV system. In this case, the efficiency ratio of PCS drops significantly at low input loads and the average conversion efficiency of PCS in summer was 76.4% decreased about 10% from 86% in winter.