• Title/Summary/Keyword: BIOMECHANICAL

Search Result 961, Processing Time 0.022 seconds

A STUDY ON THE BLEACHING EFFECTIVENESS OF BLEACHING AGENTS AND THE APICAL LEAKAGE ACCORDING TO THE LOCATION OF THE INTRACORONAL BASE (무수치 표백시 표백제의 성분에 따른 표백효과 및 이장재의 위치에 따른 치근부 누출에 대한 실험적 연구)

  • Shin, Jea-Hyun;Kim, Yang-Kee;Hong, Chan-Ui;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.145-155
    • /
    • 1993
  • The purposes of this study were to compare the bleaching efficacy of sodium perborate when mixed either with Superoxol or distilled water and to evaluate the efficacy of different location of intracoronal base on the presence of apical leakage of tested bleaching agents. Forty eight extracted human permanent incisors were stained via whole blood and canal fillings with conventional gutta percha were performed after routine biomechanical perparations. The experimental intracoronal base was placed either at the cementoenamel junction(group 3, 4) or 2mm below cementoenamel junction(group 1, 2). Walking bleaching was performed by two different combinations of bleaching agents : sodium perborate with distilled water in group 1, 3 and sodium perbrate with Superoxol in group 2, 4. The roots of the teeth were evaluated for the presence of color change to assess the leakage of bleaching agnets and the cervical one-thirds of the crown were evaluated for bleaching effect from the whiteness Indea calculated by spectrophotometer. The results were as follows : 1. At the end of 12 days, all the sample teeth demonstrated the increase of Whiteness Index at cervical 1/3 of crown although there were some minor differences among groups. 2. Regardless of location of the base, sodium perborate with superoxol)group 2, 4) showed better results in bleaching than the sodium perborate with distilled water(group 1, 3). 3. Bleaching agent leaked into the root area when the base was placed 2mm below cementoenamel junction but no leakage was found when the base was placed at the cementoenamel junction.

  • PDF

A Review of biomechanical research for Footwear Outsole Stud development in Soccer (축구화 겉창 스터드 개발에 있어서 생체역학적 연구의 고찰)

  • Park, Seung-Bum;Seo, Kuk-Woong;Kim, Yong-Jae;Lee, Joong-Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.205-221
    • /
    • 2003
  • 본 연구는 축구화 겉창의 스터드개발시 운동역학적 연구가 스터드개발에 어떻게 영향을 끼치었는가를 국외 선행연구문헌을 고찰함으로서 그 과정을 발견하는데 그 목적을 두었다. 지난 70년간 축구화 스터드가 연구개발되는 과정에서 압력분포측정 실험 및 기타 상해유발요인을 분석함으로서 스터드의 형태을 변화시키는 과정에 있어서 축구장 바닥과 축구화 겉창과의 마찰력이 중요한 변수로 작용하였다. 징이 선수들의 미끄럼을 방지하고 순발력을 향상시켜 경기력 향상에 결정적인 도움을 준 것이다. 이후 징박힌 축구화가 보편화하면서 선수들은 공격수냐 수비수냐 또는 잔디 상태에 따라 징의 개수와 길이가 다른 축구화를 신게 되었는데, 그라운드 컨디션에 따라 신발이 개발되었다. 축구화는 징의 종류에 따라 길고 푹신한 잔디($5{\sim}7$월 잔디)에 신는 50(soft ground)형, 짧고 단단한 잔디(가을철 잔디)에 적합한 FG(firm ground)형, 인조잔디나 아주 짧은 잔디에 좋은 터프(Turf)형, 맨땅에 쓰는 HG(hard ground)형으로 대별되는데, SG형은 15mm가 넘는 마그네슘 징을 6개 박는데 순발력과 파워를 극대화하기 때문에 수비수에 어울리는 스타일이다. 짧은 플리우레탄 징 12개를 다는 FG형은 넓은 그라운드 접촉면을 이루면서도 잔디에 깊게 박히지 않아 유연성을 필요로 하는 공격수와 미드필더들에게 애용된다. 그라운드 상황이 좋지 않은 곳에서 뛰는 국내 고교, 대학 선수들은 12개의 징이 달린 축구화를 선호한다. 스터드가 많을 수록 그라운드에 닿는 면적이 넓어 안정감도 있고 발목이 꺾이는 현상을 줄여주기 때문이다. 지금까지의 연구현황은 압력분포 및 지면반력실험을 이용한 결과치를 이용하여 새로운 타입의 축구화 스터드의 개발결과를 기존결과와 비교 분석하여 상해유발발생요인이 적은 스타일의 스터드를 선호하였다. 이에 향후 연구개발시 운동역학적 연구의 디자인 시 상해유발요인분석과 운동역학적 연구결과의 조합을 결과를 비교분석해서 국내에서도 축구화 겉창 스터드 연구개발시 경기력을 향상시키고, 상해유발요인을 감소시킬 수 있는 연구디자인이 지속되는 것이 중요하다고 사료된다.

The Effects of Gel-type Insole on Patients with Knee Osteoarthritis during Gait (겔-타입 인솔이 무릎 골관절염 환자의 보행에 미치는 영향)

  • Eun, Seon-Deok;Yu, Yeon-Joo;Shin, Hak-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.181-188
    • /
    • 2007
  • The purpose of this study was to investigate the biomechanical effects of wearing different type of insole shoes on gait characteristics in patients with knee osteoarthritis. Seven patients with knee osteoarthritis (Grade 3 & 4 by Kellgren & Lawrence) were participated in the study. They wore two different type of shoes (with Gel-type Insole: GIS, with Normal insole: NIS) during gait. Three dimensional cinematography and Ground Reaction Force(GRF) data were used to get the maximal value of horizontal distance between the center of pressure in GRF and knee joint center, GRF in mediolateral direction, peak value of GRF in frontal plane, vertical compressive force and adduction moment in knee joint. The results were as follows: The maximal value of horizontal distance between the center of pressure in GRF and knee joint center was smaller in GIS than NIS. The peak value of GRF in mediolateral direction was found in 30% of gait cycle, five subjects wearing GIS showed lower value of peak GRF in mediolateral direction than wearing NIS. The peak value of GRF in frontal plane and vertical compressive force in knee joint did not show any difference between GIS and NIS. The adduction moment in GIS decreased in the late stance of gait and the mean value of the adduction moment in GIS smaller than that in NIS. GIS may help to move quickly knee joint center to the center of pressure in GRF, therefore it may prevent increasing the adduction moment in knee joint.

A Critical Review of Foot Orthoses in Normal and Diseased Foot (정상의 발과 병적인 발에서 발보조기 연구의 비판적 고찰)

  • Kim, Seung-Jae;Kim, Jang-Hwan;Tack, Gye-Rae;Bae, Sang-Woo;Park, Yeong-Ki
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.81-94
    • /
    • 2007
  • The purpose of this study was to critically review biomechanical studies on foot orthoses (FO) in normal and diseased foot and provide beneficial information obtained from researches until now and future researching focus. The search was performed by Medline and Embase database including studies published in English from January 1980 to April 2007. The searching terms were foot orthoses, foot orthotics, insoles and shoe insert. 57 studies including 54 journal articles and 3 abstracts were finally selected under the conditions of having clinical trials, FO, control condition, movement, scientific measuring system. The reviewed studies were divided into 10 categories according to subject characteristics; healthy normal, excessive pronation or flexible flat foot, rheumatoid arthritis, diabetes, medial knee osteoarthritis, forefoot varus, plantar fasciitis, patellofemoral syndrome, cavus foot and finite element model. In summary, first, soft and semirigid FOs with some degree of cushioning showed much higher comfort and efficacy than rigid FO. Second, no big differences between prefabricated and custom FO were shown. Third, the full length's FO was preferable to the half length's FO or simple arch supports. Fourth, the wearing of FO combining medial arch supports and metatarsal dome made positive roles to enhance comfort and functionality and redistribute plantar pressure under the foot. Fifth, for patients with knee-related diseases lateral wedges were preferable. Sixth, measuring systems were properly applied according to the types of foot diseases.

Effects of Water Exercise on the Foot Pressure Distribution of a Female Adult with Hemiplegia: A Biomechanical Case Study

  • Lee, In-Woo;Kim, Jin-Ki;Yang, Jeong-Ok;Lee, Joong-Sook;Lee, Bom-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.2
    • /
    • pp.179-187
    • /
    • 2013
  • This case study was conducted to determine the effects of water exercise on the foot pressure distribution (FPD) of persons who have a hemiplegia. A 43-year old female with hemiplegia acquired at the age of 3 years was selected from a local disability program. A 12-week water exercise program (60 min. per session and twice a week) focusing on gait training was developed and implemented as the intervention of this study. A recent product of the Pedar-X (Novel, Germany) was used to measure the FPD of hemiplegic gait before and after the intervention. Variables considered in this study included the average pressure (AP), contact area (CA), maximum pressure (MP), ground reaction force (GRF), and center of pressure (COP). The data collected were analyzed via the descriptive statistics and qualitative analyses on the graphical presentations of the FPD. Results revealed that the AP and CA of the hemiplegic foot was considerably increased before and after the intervention. Similar results were also found in the MP and GRF. Additionally, the graphical route of the COP related to hemiplegic foot was changed in a positive way after the intervention. It can be concluded that water exercise may be beneficial to restore hemiplegic gait. Limitations related to measurement and generalizability are further discussed.

Evaluation of Biomechanical Movements and Injury Risk Factors in Weight Lifting (Snatch)

  • Moon, YoungJin
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.369-375
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the possibility of injuries and the types of movement related to damage by body parts, and to prepare for prevention of injuries and development of a training program. Method: For this study, the experiment was conducted according to levels of 60 percentages (ST) and 85 percentages (MA) and 10 subjects from the Korean elite national weightlifting team were included. Furthermore, we analyzed joint moment and muscle activation pattern with three-dimensional video analysis. Ground reaction force and EMG analyses were performed to measure the factors related to injuries and motion. Results: Knee reinjuries such as anterior cruciate ligament damage caused by deterioration of the control ability for the forward movement function of the tibia based on the movement of the biceps femoris when the rectus femoris is activated with the powerful last-pull movement. In particular, athletes with previous or current injuries should perceive a careful contiguity of the ratio of the biceps femoris to the rectus femoris. This shows that athletes can exert five times greater force than the injury threshold in contrast to the inversion moment of the ankle, which is actively performed for a powerful last pull motion and is positively considered in terms of intentional motion. It is activated by excessive adduction and internal rotation moment to avoid excessive abduction and external rotation of the knee at lockout motion. It is an injury risk to muscles and ligaments, causing large adduction moment and internal rotation moment at the knee. Adduction moment in the elbow joint increased to higher than the injury threshold at ST (60% level) in the lockout phase. Hence, all athletes are indicated to be at a high risk of injury of the elbow adductor muscle. Lockout motion is similar to the "high five" posture, and repetitive training in this motion increases the likelihood of injuries because of occurrence of strong internal rotation and adduction of the shoulder. Training volume of lockout motion has to be considered when developing a training program. Conclusion: The important factors related to injury at snatch include B/R rate, muscles to activate the adduction moment and internal rotation moment at the elbow joint in the lockout phase, and muscles to activate the internal rotation moment at the shoulder joint in the lockout phase.

Biomechanical Analysis of Injury Factor According to the Change of Direction After Single-leg Landing

  • Kim, Jong-Bin;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.433-441
    • /
    • 2016
  • Objective: The purpose of this study was to understand the injury mechanism and to provide quantitative data to use in prevention or posture correction training by conducting kinematic and kinetic analyses of risk factors of lower extremity joint injury depending on the change of direction at different angles after a landing motion. Method: This study included 11 men in their twenties (age: $24.6{\pm}1.7years$, height: $176.6{\pm}4.4cm$, weight: $71.3{\pm}8.0kg$) who were right-leg dominant. By using seven infrared cameras (Oqus 300, Qualisys, Sweden), one force platform (AMTI, USA), and an accelerometer (Noraxon, USA), single-leg drop landing was performed at a height of 30 cm. The joint range of motion (ROM) of the lower extremity, peak joint moment, peak joint power, peak vertical ground reaction force (GRF), and peak vertical acceleration were measured. For statistical analysis, one-way repeated-measures analysis of variance was conducted at a significance level of ${\alpha}$ <.05. Results: Ankle and knee joint ROM in the sagittal plane significantly differed, respectively (F = 3.145, p = .024; F = 14.183, p = .000), depending on the change of direction. However, no significant differences were observed in the ROM of ankle and knee joint in the transverse plane. Significant differences in peak joint moment were also observed but no statistically significant differences were found in negative joint power between the conditions. Peak vertical GRF was high in landing (LAD) and after landing, left $45^{\circ}$ cutting (LLC), with a significant difference (F = 9.363, p = .000). The peak vertical acceleration was relatively high in LAD and LLC compared with other conditions, but the difference was not significant. Conclusion: We conclude that moving in the left direction may expose athletes to greater injury risk in terms of joint kinetics than moving in the right direction. However, further investigation of joint injury mechanisms in sports would be required to confirm these findings.

Adhesion Prevention with Guardix® (Sodium Hyaluronate) After Flexor Tendon Repair in Rabbits (토끼 모델에서 굴근 인대 봉합 후 가딕스®의 유착 방지 효과)

  • Kim, Hark Young;Chang, Hak;Minn, Kyung Won
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.543-547
    • /
    • 2009
  • Purpose: Adhesion is the most common and troublesome complication after repair of flexor tendon injury. Recently, use of sodium hyaluronate derivatives for adhesion prevention is increasing. A commercial product, Guardix$^{(R)}$, sodium hyaluronate(NaHe) combined with carboxymethylcellulose(CMC) has been newly developed as a preventive material for adhesion. We have investigated its effect in rabbits. Methods: Twenty seven male New Zealand white rabbits were operated under ketamine anesthesia. After tendon repair in zone II of the hind paw, Guardix$^{(R)}$(experimental group) or normal saline(control group) was administered. Biomechanical tests were performed to estimate adhesion formation at 2, 4, 8, and 12 weeks after the operation. Maximum tensile load to flex the distal interphalangeal joint 50 degree from its resting state(MTL50) was measured, depicting the amount of adhesion formed. Subsequently, breaking strength was assessed. Results: There were no postoperative complications such as infection, wound dehiscence, or hematoma. MTL50 was significantly lower in the experimental group than in the control group at 4, 8, 12 weeks (p<0.05). Mean value of MTL50 was 6.64N in the experimental group and 28.53N in the control group at 12 weeks after surgery. There were no significant differences in breaking strength. Conclusion: Our results indicate that Guardix$^{(R)}$ is helpful in reducing adhesion formation and does not interfere with normal healing processes of the tendon.

Virtual Test Framework for Smith Squat Exercise Based on Integrated Product-Human Model (제품과 인체의 통합 모델을 바탕으로 한 스미스 스쿼트 운동의 가상 시험 프레임워크)

  • Lee, Haerin;Jung, Moonki;Lee, Sang Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.691-701
    • /
    • 2017
  • The barbell squat is a fundamental physical exercise for strengthening the lower body and core muscles. It is an integral part of training and conditioning programs in sports, rehabilitation, and fitness. In this paper, we proposed a virtual test framework for squat exercises using a Smith machine to simulate joint torques and muscle forces, based on an integrated product-human model and motion synthesis algorithms. We built a muscular skeletal human model with boundary conditions modeling the interactions between the human body and a machine or the ground. To validate the model, EMG, external forces, and squat motions were captured through physical experiments by varying the foot position. A regression-based motion synthesis algorithm was developed based on the captured squat motions to generate a new motion for a given foot position. The proposed approach is expected to reduce the need for physical experiments in the development of training programs.

Characteristics of Abutment Screw Structure for Dental Implant (치과용 임플란트 지대주 나사 구조에 관한 연구)

  • Song, Jong-Beop;Choi, Il-kyung;Jung, Hyo-kyung;Kwon, Soon-Hong;Kwon, Soon-Gu;Park, Jong-Min;Kim, Jong-Soon;Jung, Sung-Won;Choi, Won-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.2
    • /
    • pp.169-176
    • /
    • 2017
  • Dental implants are required to have biomechanical functions and biostability in order to perform authoring, pronunciation, and aesthetic functions in the oral cavity. In terms of biostability, pure titanium for medical have good biostability and no rejection in the alveolar bone. with appropriate strength in terms of strength as well as biocompatibility. In recent years, various surgical methods and devices have been developed to improve the convenience and safety of the procedure. However, as the number of procedures increases, the screw loosening of the abutment screw connecting the artificial root and the abutment There are many reports of artificial root and abutment fracture. Fig. 1 is an example of a case where the upper part of the abutment screw is arbitrarily modified to remove the abutment by the abutment fracture due to the loosening of the abutment screw. The fundamental cause of abduction of the abutment screw is caused by the slight movement due to the lowering of the retention force of the abutment screw. It is necessary to minimize loosening of the abutment screw to avoid problems such as fracture during the period of using the implant. The purpose of this study is to investigate the structure of the abutment screw to prevent the loosening of the abutment screw by forming 0.5mm slot.