• Title/Summary/Keyword: Average Technique

Search Result 2,730, Processing Time 0.039 seconds

Enhancing Venous Anastomosis Visualization in Murine Kidney Transplants: The Two Stay Suture Technique

  • Jong-Min Kim
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.423-428
    • /
    • 2023
  • The mouse kidney transplantation model serves as an invaluable tool for exploring various aspects of the transplant process, including acute rejection, cellular and humoral rejection, ischemia-reperfusion injury, and the evaluation of novel therapeutic strategies. However, conducting venous anastomosis in this model poses a significant challenge due to the thin and pliable characteristics of the renal vein, which often obstruct clear visualization of the resected vein's edge. This study proposes the adoption of a two stay suture technique to enhance the visualization of the renal vein's edge, thereby facilitating efficient and successful venous anastomosis. A total of 22 mice served as kidney donors in this study. The conventional anchoring suture technique was employed for venous anastomosis in 11 of these mice, while the remaining 11 underwent the two stay suture technique. The anastomosis duration and completion rates were then compared between these two groups. The conventional anchoring suture technique yielded an average anastomosis time of 29 minutes and a completion rate of 64%. In contrast, the two stay suture technique demonstrated a substantial improvement, with an average anastomosis time of 14 minutes and a completion rate of 100%. The two stay suture technique offers a promising solution to enhance visualization during venous anastomosis in murine kidney transplantation. This technique may particularly benefit novices by enabling them to perform venous anastomosis more easily, swiftly, and successfully.

Digital Control of an AC/DC Converter using the Power Balance Control Technique with Average Output Voltage Measurement

  • Wisutmetheekorn, Pisit;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.88-97
    • /
    • 2012
  • This paper presents a method for the digital control of a high power factor AC/DC converter employing the power balance control technique to achieve a fast response of the output voltage control. To avoid the effects of an output voltage ripple in the voltage control loop, the average output voltage is sampled and used as a feedback signal for the output voltage controller. The proposed control technique was verified by simulations using MATLAB/Simulink and its implementation was realized by a dsPIC30F4011 digital signal processor to control a CUK topology AC/DC converter with a 48V output voltage and a 250 W output power. The experimental results agree with the simulation results. The proposed control technique achieves a fast transient response with a lower line current distortion than is achieved when using a conventional proportional-integral controller and the power balance control technique with the conventional sampling method.

Garbage Collection Technique for Balanced Wear-out and Durability Enhancement with Solid State Drive on Storage Systems

  • Kim, Sungho;Kwak, Jong Wook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.4
    • /
    • pp.25-32
    • /
    • 2017
  • Recently, the use of NAND flash memory is being increased as a secondary device to displace conventional magnetic disk. NAND flash memory, as one among non-volatile memories, has many advantages such as low power, high reliability, low access latency, and so on. However, NAND flash memory has disadvantages such as erase-before-write, unbalanced operation speed, and limited P/E cycles, unlike conventional magnetic disk. To solve these problems, NAND flash memory mainly adopted FTL (Flash Translation Layer). In particular, garbage collection technique in FTL tried to improve the system lifetime. However, previous garbage collection techniques have a sensitive property of the system lifetime according to write pattern. To solve this problem, we propose BSGC (Balanced Selection-based Garbage Collection) technique. BSGC efficiently selects a victim block using all intervals from the past information to the current information. In this work, SFL (Search First linked List), as the proposed block allocation policy, prolongs the system lifetime additionally. In our experiments, SFL and BSGC prolonged the system lifetime about 12.85% on average and reduced page migrations about 22.12% on average. Moreover, SFL and BSGC reduced the average response time of 16.88% on average.

Loop Suture Technique for Flexor Digitorum Profundus Tendon Repair in the Insertion Site (고리 봉합법을 이용한 심부 수지 굴건 종지부에서의 건봉합)

  • Lee, Kyu-Cheol;Lee, Dong-Chul;Kim, Jin-Soo;Ki, Sae-Hwi;Roh, Si-Young;Yang, Jae-Won
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.650-658
    • /
    • 2010
  • Purpose: In the case of repair for far distal parts of FDP (Flexor digitorum profundus) division, the method of either pull-out suture or fixation of tendon to the distal phalanx is preferred. In this paper, the results of a modified loop suture technique used for the complete division of FDP from both zone 1a and distal parts of zone 1b in Moiemen classification are presented. Methods: From July 2006 to July 2009, the modified loop suture technique was used for the 10 cases of FDP in complete division from zone 1a and distal parts of zone 1b, especially where insertion sites were less than 1 cm apart from a tendon of a stump. In a suture technique, a loop is applied to each distal and proximal parts of tendon respectively. Core suture of 2-strand and epitendinous suture are done with PDS 4-0. Out of 10 patients, the study was done on 6 patients who were available for the followup. The average age of the patients was 49.1 years (in the range from 26 to 67). 5 males and 1 female patients were involved in this study. There were 3 cases with zone 1a and distal parts of zone 1b. The average distance to the distal tendon end was 0.6 cm. There were 5 cases underwent microsurgical repair where both artery and nerve divided. One case of only tendon displacement was presented. The dorsal protective splint was kept for 5 weeks on average. The results of the following tests were measured: active & passive range of motion, grip strength test, key pinch and pulp pinch test. Results: The follow-up period on average was 11 months, in the range from 2 to 20 months. There was no case of re-rupture, but tenolysis was performed in 1 cases. In all 6 cases, the average active range of motion of distal interphalangeal joint was 50.8 degree. The grip strength (ipsilateral/contralateral) was measured as 88.7% and the pulp pinch test was 79.2% as those of contralateral side. Flexion contracture was presented in 2 cases (15 degree on average) and there was no quadrigia effect found. Conclusion: Despite short length of tendon from the insertion site in FDS rupture in zone 1a and distal parts of zone 1b, sufficient functional recovery could be expected with the tendon to tendon repair using the modified loop suture technique.

Two Techniques of Angle-of-Arrival Estimation for Low-Data-Rate UWB Wireless Positioning (저속 초광대역 방식의 무선 측위에 알맞은 신호 도착 방향 추정 기법 두 가지)

  • Lee, Yong-Up;Lim, Kyeong-Sun;Park, Joo-Hyeon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.3A
    • /
    • pp.163-171
    • /
    • 2012
  • The signal model and weighted-average based estimation techniques are proposed to estimate the angle-of-arrival (AOA) parameters of multiple clusters for a low data rate ultrawide band (LR-UWB) based wireless positioning system. It is observed that the weighted-average based AOA estimation technique gives an optimal AOA estimate under few clusters condition, and the average based AOA estimation technique gives a correct AOA estimate under many clusters condition through computer simulation. Also, we can observe that the variance estimation error decreases as SNR increases, and the proposed techniques are superior to the conventional technique from the viewpoint of performance.

The Accuracy of the Radiographic Method in Root Canal Length Measurement (근광장 측정에서 방사선 사진술의 정확도)

  • Jo Eun-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

Average Current Mode Control Technique Having Fast Response (빠른 응답 특성을 가지는 Average Current Mode Control 설계 기법 연구)

  • Park, Hae-Chan;Kim, Il-Song
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.231-239
    • /
    • 2017
  • A novel current control technique with fast response and application in an unbalanced system is proposed in this paper. Contrary to the conventional PI and dead-beat current control techniques, the proposed method is adopted to the valley current mode control (VCMC) and average current mode control (ACMC) methods to overcome the phase delay caused by conventional methods. The advantages of the proposed system are simplicity of structure and ease of implementation. The VCMC and ACMC methods are established and applied to the buck converter, boost converter, three-phase PWM converter, and three-phase inverter. The control performances of the proposed systems are shown by computer simulations and verified by experimental results.

Surgical Repair of Achilles Tendon Rupture by Minimal Incision Technique (최소 절개 기법에 의한 아킬레스건 파열의 수술적 봉합술)

  • Jung, Hong-Geun;Paik, Ho-Dong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.2
    • /
    • pp.173-178
    • /
    • 2005
  • Propose: There have been many debates about the ideal surgical technique for acute Achilles tendon rupture. The purpose of this study is to review and analyze the clinical outcome of the acute Achilles tendon ruptures that had been repaired by indirect suture technique with minimal incision that utilized an instrument called Achillon (Newdeal, France). Materials and Methods: This study is based on the 14 cases (14 patients) of acute Achilles tendon total ruptures that have been repaired by minimal incision technique utilizing Achillon instrument from June 2003 to December 2004. Two cases were reruptured before 8 weeks and repaired again using Krackow suture which left 12 feet for postoperative functional evaluation with at least 6 months of follow-up. Ten cases were men and average age at time of injury was 34.4 (26-49) years. The time from injury to surgery was an average of 4.5 (1-9) days and the postoperative evaluations were done by an Arner-Lindholm scale and AOFAS score. The ability to return to original work and sports activities as well as patient satisfaction were also evaluated. Results: The follow-up period was averaged for 13.2 (6-24) months. Seventy-one percent of cases were ruptured during sports activities. The ruptured level was the average of 5.1 cm (3.2-8 cm) above calcaneal attachment and the skin incision was averaged for 2.7 cm (2.5-3.0 cm) long. At final follow-up, standing on tip-toe was possible in all cases while the heel-floor height on ruptured side was shorter by 0.7 cm (0-2 cm). By Arner-Lindholm evaluation scale, 9 cases were excellent, and 3 cases were good. Overall AOFAS score was an average of 96.1 (94-100), and all patients were satisfied with the result. Patients returned to work at an average of 1.3 months after the surgery and pre-injury sports activities were all possible from at 6 months after operation. Conclusion: Since we have treated acute Achilles tendon ruptures with minimal incision technique utilizing the Achillon and gained encouraging functional results with all patients returning to previous work with high patient satisfaction, this technique could be recommended as one of the ideal surgical options for the Achilles tendon ruptures.

  • PDF

Digital Control of a Power Factor Correction Boost Rectifier Using Diode Current Sensing Technique

  • Shin, Jong-Won;Hyeon, Byeong-Cheol;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.903-910
    • /
    • 2009
  • In this paper, a digital average current mode control using diode current sensing technique is proposed. Although the conventional inductor current sensing technique is widely used, the sensed signal of the current is negative. As a result, it requires an additional circuit to be applied to general digital controller ICs. The proposed diode current sensing method not only minimizes the peripheral circuit around the digital IC but also consumes less power to sense current information than the inductor current sensing method. The feasibility of the proposed technique is verified by experiments using a 500W power factor correction (PFC) boost rectifier.

The Evaluation of Reliability in a Composite Power System using Simplified Simulation Techniques (간략화 모의 기법을 이용한 대전력 계통 신뢰도 계산)

  • Kim, Dong-Hee;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.221-223
    • /
    • 1997
  • This paper presents the Simplified Simulation Technique that evaluates the adequacy of an electric power system using only a portion of the outage period instead of each hour. Reliability evaluation may be performed at various hierarchical levels, generation, transmission and distribution system. The Simplified Simulation Technique simplifies the adequacy evaluation process reducing the number of calculations considerably. Therefore the computation time can be significantly reduced. This paper is done to compare the results of the simulation model with the Simplified Simulation Technique against the results of the simulation model without the Simplified Simulation Technique. The reliability indices such as the Loss of Load Probability(LOLP), the loss of load frequency(LOLF), the average duration of load curtailment(DLC) and the average demand of load curtailment(ADLC) are calculated. The proposed methods and procedures are tested by using the IEEE-RTS with 24-bus system.

  • PDF