• Title/Summary/Keyword: Average $CO_2$ concentration

Search Result 443, Processing Time 0.03 seconds

A Comparative Analysis on Concentration of Pollutants in Housing Indoor-Air between Winter and Summer (주택 실내 공기중 오염물질 농도의 동절기와 하절기 비교 분석)

  • Nam, Ki-Cheul;Lee, Young-Han;Choi, Bong-Seok
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.125-131
    • /
    • 2017
  • Purpose: The study is to measure concentrations of indoor air pollutants in housing and to analyze the characteristics of pollutants in housing indoor-air between summer and winter comparatively. The research result could be used as data for public health through indoor air quality management of existing housing and more as a reference for new housing. Method: It was investigated 24 middle class housings of metropolitan area in winter which have been built for the past 30 years. Concentration of HCHO, TVOC was investigated in living room at morning and night and concentration of $CO_2$ was investigated in living room and master bedroom at morning and night. SKT100-X5 was used for concentration of HCHO, TVOC and ZGm053UK for concentration of $CO_2$. The characteristics of HCHO, TVOC, $CO_2$ concentration in winter were analyzed and then the concentrations in winter were analyzed the concentrations in summer being preceding research comparatively. Result: Average concentration of TVOC in winter was 2.7 times more than that of TVOC in summer, average concentration of HCHO in winter was about 2.0 times more than that of HCHO in summer. Average concentration of $CO_2$ in the morning at living room in winter was 1.3 times more than that of $CO_2$ in summer. Average concentration of $CO_2$ in the morning at master bedroom in winter was 1.1 times more than that of $CO_2$ in summer. Average concentration of TVOC was 1.31 times more than that of HCHO and standard deviation of that was 1.73 times higher. Average concentration of $CO_2$ was almost nearly close or over to 1,000ppm being criteria of the Ministry of Environment.

An Analysis on HCHO, TVOC, CO2 Concentration of Existing-Housing Indoor-Air in Summer (기존 주택의 하절기 실내 공기중 HCHO, TVOC, CO2 농도 실태 조사분석)

  • Nam, Ki-Cheul;Lee, Young-Han
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.115-122
    • /
    • 2016
  • Purpose: The study is to measure indoor air pollutants concentration of existing housing and to analyze the causes and assess in accordance with the government's criteria. The research result could be used as data for public health through indoor air quality management of existing housing and more as a reference for new housing. Method: It was investigated 24 middle class housings of metropolitan area in summer which have been built for the past 30 years. Concentration of HCHO, TVOC was investigated in living room at morning and night and concentration of $CO_2$ was investigated in living room and master bedroom at morning and night. SKT100-X5 was used for concentration of HCHO, TVOC and ZGm053UK for concentration of $CO_2$. Result: Average concentration of TVOC was 1.31 times more than that of HCHO and standard deviation of that was 1.73 times higher. Average concentration of $CO_2$ was almost nearly close to 1,000ppm being criteria of the Ministry of Environment.

Characteristics of PM10, PM2.5 and CO2 Concentration in Public Transportations and Development of Control Technology (대중교통수단에서 PM10, PM2.5 및 CO2의 농도 현황과 저감기술 개발에 관한 연구)

  • Park, Duck Shin;Kwon, Soon Bark;Cho, Young Min;Jang, Seong Ki;Jeon, Jae Sik;Park, Eun Young
    • Particle and aerosol research
    • /
    • v.6 no.1
    • /
    • pp.9-20
    • /
    • 2010
  • This study examined the concentration level of the major air pollutants in public transportation. The study was conducted between February 2009 and March 2008 at Suwon-Yeosu line in Korea. $PM_{10}$ concentration level was $100{\mu}g/m^3$ on average. The $PM_{2.5}$ to PM10 ratio in transport is 0.37, which was lower than the results published by other researches. The result also demonstrated that outdoor $PM_{10}$ concentration was about 56~60% level compared to that of the cabin. $CO_2$ concentration level in the cabin was 1,359ppm, which does not exceed 2,000ppm, which is the guideline concentration level according to the Ministry of Environment. $CO_2$ concentration level in the cabin was $CO_2=23.4{\times}N+460.2$, and about 23.4ppm in $CO_2$ concentration level increased every time one passenger was added on. The experiment conducted on the train demonstrated that the average $PM_{10}$ concentration level was $100{\mu}g/m^3$ in case of the reference cabin while average $PM_{10}$ concentration level of the modified vehicle was $68{\mu}g/m^3$. Likewise, effect of the particle reduction device for the reduction of $PM_{10}$ concentration level was approximately 21%. Meanwhile there was almost no difference in the concentration level between reference and modified cabin in case of $PM_{2.5}$. Using zeolite as an adsorbent was made to reduce the $CO_2$ concentration level in the cabin. Number of passengers was factored in, to calculate the effect of the adsorption device, which demonstrated that about 36% of $CO_2$ concentration level was reduced in the modified cabin effect of the $CO_2$ reduction device. This research analyzed the current status concerning the quality of air in the public transportation and technologies were developed that reduces major air pollutants.

Growth and Development Response of Bell Pepper (Capsicum annum L.) to $CO_2$ Enrichment under Three Different Temperature Regimes (3온도 수준에서의 $CO_2$ 농도 증가에 따른 피망의 생육 반응)

  • Yoon, Seong-Tak
    • Korean Journal of Organic Agriculture
    • /
    • v.15 no.1
    • /
    • pp.71-84
    • /
    • 2007
  • Predicting plant responses to changing atmospheric $CO_2$ and to the possibility of global warming are important concerns. The $CO_2$ concentration of the global atmosphere has increased during the last decades. This increase is expected to result in changes of global temperatures and this will also affect the growth and development of bell pepper (Capsicum annum L.) and other crops. The objective of this study was to evaluate the effects of atmospheric $CO_2$ enrichment and high temperature on the growth and development of bell pepper under three temperature regimes. There was no statistical difference in the days required from seeding to flowering between $CO_2$ treatments, whereas among three temperature regimes, high temperature plots of $35/25^{\circ}C$ showed the shortest days (52.5 days) required from seeding to flowering. The plant height of bell peppers 15 weeks after emergence showed no statistical significance, while plots of $30/20^{\circ}C$ showed the highest plant height among the three temperature regimes. Time-course response of plant height to $CO_2$, enrichment was restrained in high $CO_2$, concentration (800ppm), at the same time higher temperature promoted plant height. Average leaf area per plant of 400ppm was $6,008.8cm^2$ and it was $5,225.1cm^2$ in the plots of 800ppm, showing 15% more leaf area compared to 400ppm $CO_2$ concentration. Leaf dry weight between $CO_2$ concentration and among temperature regimes showed a statistical significance. The average leaf dry weight in the plot of 800ppm showed the highest (44.1g), which was 18.5% higher compared to that of 400ppm (37.2g) and among temperature regimes, it was the highest (49.8g) in the plot of $35/25^{\circ}C$. Above-ground dry weight showed statistical significance between $CO_2$ concentration and among temperature regimes. The average above-ground dry weight of 800ppm $CO_2$ concentration was 141.4g, 17.9% higher compared to 400ppm $CO_2$ concentration (119.9g). Among three temperature regimes, plots of $30/20^{\circ}C$ showed the highest average above-ground dry weight (168.9g), while plots of $35/25^{\circ}C$ were the lowest (102.3g). In the average bell pepper dry weight, 800ppm of $CO_2$ concentration showed higher bell pepper dry weight (59.5g) than that (44.3g) of 400ppm of $CO_2$ concentration. It was judged that high $CO_2$ concentration was profitable fur bell pepper yield and there was a tendency that when there was high $CO_2$, concentration (800ppm), low temperature ($25/15^{\circ}C$) was profitable for bell pepper dry weight, whereas it was the reverse ($30/20^{\circ}C$), in the case of ambient $CO_2$, concentration (400ppm). In the specific leaf area according to $CO_2$, concentration, 800ppm showed 117.4, which was 35.5% higher compared to that (159.1) of 400ppm, showing that leaf becomes thicker as $CO_2$ concentration increases. Regarding correlation coefficients among crop characteristics, leaf area was negatively correlated with the number of bell peppers per plant and bell pepper dry weight, showing that the higher the leaf area, the lower the bell pepper yield. Bell pepper dry weight per plant showed positively significant correlation with the number of bell peppers per plant and total above dry weight, which showed that the higher the number of bell peppers and the total above dry weight, the higher the bell pepper yield.

  • PDF

Changes of Average Specific Resistance on Suspension Concentration (현탁액의 농도에 다른 여과 현균비저항값의 변화)

  • 장재선
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.1
    • /
    • pp.12-20
    • /
    • 1996
  • This study was carried out to investigate the change of average .specific resistance according to suspension concentration for study phenomena occurring during filtration period. As the results of this study, the following conclusions were obtained. The average specific resistance in 1% $CaCO_3$ suspension was showed power function(R=0.99), whereas in TOYO 5C and TOYO 5A paper were made little difference under high pressure. It represented from results that filtration theory in concord with cake filtration was no affected the average specific resistance of filter medium in cake filtration. In case of 0.1% $CaCO_3$ suspension filtration, the TOYO 5C was showed power function, whereas in TOYO 5A paper differently. In the present study, the $P_1$ value was calculated from the average specific resistance by filtration method. Therefore, $P_1$ value were $1.68\times 10^4Pa$, $4.05\times 10^3Pa$, and $3.15\times 10^3Pa$ in $5.3\times 10^4Pa$, $1.3\times 10^4Pa$, and $8.2\times 10^3Pa$, respectively. We concluded that propriety of new filtration theory was also proved.

  • PDF

Numerical Simulation on Ventilation Characteristics of an Underground Bus Parking Lot (버스전용 지하주차장의 환기 특성에 관한 수치해석적 연구)

  • Seung, Sam-Sun;Lee, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.179-184
    • /
    • 2007
  • In this paper, the ventilation characteristics of an underground parking lot with 17 buses has been investigated for two cases by computational fluid dynamics. It has been found that the average concentration of CO and $NO_x$ gas in the parking lot were 1.3 and 0.3 ppm respectively, when four buses operated. When the fifteen vehicles stopped in the parking lot, the average concentration of CO and $NO_x$ gas was 2.9 and 0.8 ppm respectively. The average concentration of two pollutants$(CO,\;NO_x)$ are lower than the standard values. Therefore the facilities and its location is proper to ventilation.

  • PDF

Analysis of Spatial and Vertical Variability of Environmental Parameters in a Greenhouse and Comparison of Carbon Dioxide Concentration in Two Different Types of Greenhouses (온실 환경요인의 공간적 및 수직적 특성 분석과 온실 종류에 따른 이산화탄소 농도 비교)

  • Jeong, Young Ae;Jang, Dong Cheol;Kwon, Jin Kyung;Kim, Dae Hyun;Choi, Eun Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.221-229
    • /
    • 2022
  • This study was aimed to investigate spatial and vertical characteristics of greenhouse environments according to the location of the environmental sensors, and to investigate the correlations between temperature, light intensity, and carbon dioxide (CO2) concentration according to the type of greenhouse. Temperature, relative humidity (RH), CO2, and light sensors were installed in the four-different vertical positions of the whole canopy as well as ground and roof space at the five spatial locations of the Venlo greenhouse. Also, correlations between temperature, light intensity, and CO2 concentration in Venlo and semi-closed greenhouses were analyzed using the Curve Expert Professional program. The deviations among the spatial locations were larger in the CO2 concentration than other environmental factors in the Venlo greenhouse. The average CO2 concentration ranged from 465 to 761 µmol·mol-1 with the highest value (646 µmol·mol-1) at the Middle End (4ME) close to the main pipe (50Ø) of the liquefied CO2 gas supply and lowest (436 µmol·mol-1) at the Left Middle (5LM). The deviation among the vertical positions was greater in temperature and relative humidity than other environments. The time zone with the largest deviation in average temperature was 2 p.m. with the highest temperature (26.51℃) at the Upper Air (UA) and the lowest temperature (25.62℃) at the Lower Canopy (LC). The time zone with the largest deviation in average RH was 1 p.m. with the highest RH (76.90%) at the LC and the lowest RH (71.74%) at the UA. The highest average CO2 concentration at each hour was Roof Air (RF) and Ground (GD). The coefficient of correlations between temperature, light intensity, and CO2 concentration were 0.07 for semi-closed greenhouse and 0.66 for Venlo greenhouse. All the results indicate that while the CO2 concentration in the greenhouse needs to be analyzed in the spatial locations, temperature and humidity needs to be analyzed in the vertical positions of canopy. The target CO2 fertilization concentration for the semi-closed greenhouse with low ventilation rate should be different from that of general greenhouses.

Distribution Characteristics between Line and Line for Indoor Air Pollutant Factors at Subway Stations in Seoul Area (서울지역 지하철역의 공기 중 오염인자의 노선별 분포 특성)

  • 김민영;라승훈;신도철;한규문;최금숙;정일현
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.2
    • /
    • pp.134-144
    • /
    • 1998
  • A comprehensive air quality monitoring was carried out to investigate the criteria concentration of air pollutant in indoor of subway stations of Seoul City. The samples were collected twice per year (the first and the second half of the year) at each sampling point from February to September in 1997. Sampling point of subway stations was ticket office and platform. The measurement of indoor air pollutants such as sulfur dioxide(SO$_2$), nitrogen dioxide(NO$_2$), carbon monoxide(CO), carbon dioxide(CO$_2$), total suspended particulate(TSP) was performed to determine the indoor air quality. Heavy metals(Pb, Cd, Cu, Cr, As, Hg) were also measured together with those air pollutants. The annual average concentration of CO$_2$ and TSP in subway stations were relatively high while those of heavy metals were within 10% of environmental recommended standard concentration in all stations. As results of regression analysis between line and line of air factors, the concentrations of CO, CO$_2$, TSP, Pb, Cd, Cr and Cu were highly correlated, but those of $SO_2, NO_2$ and Hg were not correlated. As results of regression analysis between ticket office and platform, the concentrations of heavy metals such as Cr and Cu were highly correlated. Results of oneway analysis of variance between the first and the second half of the year air factors also indicated that CO, CO$_2$, Cd, Cu, Hg were significant($\alpha$=0.01), respectively. The average contration of total suspended particulate(TSP) in subway line No. 1 was shown high concentration(200 $\mu g/m^3\cdot$ day) level.

  • PDF

Can $CO_2$ concentration at one level of eddy covariance measurement be used to estimate storage term over forest\ulcorner

  • Choi, Tae-Jin;Chae, Nam-Yi;Kim, Joon;Lim, Jong-Hwan
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.47-50
    • /
    • 2003
  • $CO_2$ concentration profile was measured to investigate whether $CO_2$ concentration at one level (i.e., eddy covariance measurement level) can be used to estimate storage term without significant uncertainty at broadleaf deciduous forest at Kwangneung experiment forest in Korea. Based on t-test with significance level of 5%, there was no statistical difference between storage term from one-level $CO_2$ concentration and one from $CO_2$ profile measurement. Storage term constitutes on average 5% of half hourly net ecosystem exchange (NEE) even at unstable stability (i.e., well mixed condition), indicating that storage term should be considered even at daytime, which is sometimes neglected.

  • PDF

Ammonia and Carbon Dioxide Concentrations in a Layer House

  • Kilic, Ilker;Yaslioglu, Erkan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.8
    • /
    • pp.1211-1218
    • /
    • 2014
  • Higher concentrations of ammonia ($NH_3$) and carbon dioxide ($CO_2$) in animal barns can negatively affect production and health of animals and workers. This paper focuses on measurements of summer concentrations of ammonia ($NH_3$) and carbon dioxide ($CO_2$) in a naturally ventilated laying henhouse located at an egg production facility in Bursa region, western Turkey. Also, indoor and ambient environmental conditions such as temperature and relative humidity were measured simultaneously with pollutant gas concentrations. The average $NH_3$ concentrations during summer of 2013 was 8.05 ppm for exhaust and 5.42 ppm for inlet while average $CO_2$ concentration was 732 ppm for exhaust and 625 ppm for inlet throughout summer. The overall minimum, average and maximum values and humidity were obtained as $16.8^{\circ}C$, $24.72^{\circ}C$, and $34.71^{\circ}C$ for indoor temperature and 33.64%, 63.71%, and 86.18% for relative humidity. The lowest exhaust concentrations for $NH_3$ and $CO_2$ were 6.98 ppm and 609 ppm, respectively. They were measured in early morning at the maximum diurnal ventilation rate in July 2013 and August 2013. The highest concentrations were 10.58 ppm for $NH_3$ and 904 ppm for $CO_2$ recorded in the afternoon when the ventilation rate was the lowest in June 2013.