• Title/Summary/Keyword: Auxiliary devices

Search Result 225, Processing Time 0.031 seconds

Design of closed-loop nitrogen Joule-Thomson refrigeration cycle for 67 K with sub-atmospheric device

  • Lee, C.;Lee, J.;Jeong, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • Closed-loop J-T (Joule-Thomson) refrigeration cycle is advantageous compared to common open loop $N_2$ decompression system in terms of nitrogen consumption. In this study, two closed-loop pure $N_2$ J-T refrigeration systems with sub-atmospheric device for cooling High Temperature Superconductor (HTS) power cable are investigated. J-T cooling systems include 2-stage compressor, 2-stage precooling cycle, J-T valve and a cold compressor or an auxiliary vacuum pump at the room temperature. The cold compressor and the vacuum pump are installed after the J-T valve to create sub-atmospheric condition. The temperature of 67 K is possible by lowering the pressure up to 24 kPa at the cold part. The optimized hydrocarbon mixed refrigerant (MR) J-T system is applied for precooling stage. The cold head of precooling MR J-T have the temperature from 120 K to 150 K. The various characteristics of cold compressor are invstigated and applied to design parameter of the cold compressor. The Carnot efficiency of cold compressor system is calculated as 16.7% and that of vacuum pump system as 16.4%. The efficiency difference between the cold compressor system and the vacuum pump system is due to difference of enthalpy change at cryogenic temperature, enthalpy change at room temperature and different work load at the pre-cooling cycle. The efficiency of neon-nitrogen MR J-T system is also presented for comparison with the sub-atmospheric devices. These systems have several pros and cons in comparison to typical MR J-T systems such as vacuum line maintainability, system's COP and etc. In this paper, the detailed design of the subcooled $N_2$ J-T systems are examined and some practical issues of the sub-atmospheric devices are discussed.

New hysteresis current control for induction motor drive with NPC inverter (NPC 인버터에 의한 유도전동기 구동시스템의 새로운 히스테리시스 전류 제어기법)

  • 김춘삼;이병송
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 1999
  • A new current controlled PWM t'||'&'||'pound;rlmique with NPC(Neutral Point Qarll)ed) structure is IrOIX>Sed in this paper. A current controlled PWM technique with neutral-JXlint-cIamped pulse-width modulation inverter composed of main switching devices which operates as switch for PWM and auxiliary switching devices to clamp the output terminal potential to the neutral point potential is described. The proposed current controller has a first and second current band The switching pattern will be made by the first current band. According to the second current band, the output state of the switching pattern is changed into positivee and negative state. This inverter output contains less hanronic content and lower switching frequency than that of conventional current controlled PWM technique at the same current limit. Thbe induction machine drive with proposed technique is investigated by commputer simulation.

  • PDF

A New High-Efficient Energy-Recovery Circuit for Plasma Display Panel (새로운 에너지 회수 방식을 채용한 고효율 PDP 구동 회로)

  • 韓 翔 圭;李 俊 榮;文 建 又;尹 明 重;朴 昌 培;丁 南 聲;朴 正 泌
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.121-128
    • /
    • 2002
  • A new high-efficient energy-recovery circuit is proposed to drive a plasma display panel (PDP) and compared with the conventional circuit. The proposed circuit uses only two inductors and no auxiliary circuit to recover the energy stored in the equivalent intrinsic capacitance of PDP. Therefore it features a simpler structure, less mass, lower cost of production, higher efficiency, and fewer power devices. The very stable and uniform light emitted from PDP proves the high quality of screen. It is suitable for wall-hanging color TVs. The proposed circuit, operating at 200kHz, is verified to be applicable on a 42-inch PDP by experimental results.

Introducing Depth Camera for Spatial Interaction in Augmented Reality (증강현실 기반의 공간 상호작용을 위한 깊이 카메라 적용)

  • Yun, Kyung-Dahm;Woo, Woon-Tack
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.62-67
    • /
    • 2009
  • Many interaction methods for augmented reality has attempted to reduce difficulties in tracking of interaction subjects by either allowing a limited set of three dimensional input or relying on auxiliary devices such as data gloves and paddles with fiducial markers. We propose Spatial Interaction (SPINT), a noncontact passive method that observes an occupancy state of the spaces around target virtual objects for interpreting user input. A depth-sensing camera is introduced for constructing the virtual space sensors, and then manipulating the augmented space for interaction. The proposed method does not require any wearable device for tracking user input, and allow versatile interaction types. The depth perception anomaly caused by an incorrect occlusion between real and virtual objects is also minimized for more precise interaction. The exhibits of dynamic contents such as Miniature AR System (MINARS) could benefit from this fluid 3D user interface.

  • PDF

Effect of health behavior on periodontal disease of adolescents (청소년의 건강행태가 치주질환에 미치는 영향)

  • Ma, Jae-Kyung;Park, Eui-Jung;Kim, Chang-Yoon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.617-623
    • /
    • 2016
  • Objectives: The purpose of this study is to investigate the effect of health behavior on oral health of Korean adolescents. Methods: The study subjects were 1,071 adolescents of 13-18 years old from Korea National Health and Nutrition Examination Survey (KNHANES) 2010-2012. Male students were 54.5% and female students were 45.5%. The study consisted of two groups: 13-15 years old and 16-18 years old groups. Data were analyzed by SAS 9.13 version. Results: Those who ingested alcohol had gingival bleeding in 41.0% and 31.0% in those who did not. Those who did not have regular oral examinations had 38.5% of gingival bleeding while those with regular oral examination had 29.7% of gingival bleeding (p<0.01). Students between 16 to 18 years old without oral care products tended to have more gingival bleeding than those who use auxiliary oral hygiene devices (OR=2.658, 95% CI=1.327-5.324). Conclusions: The oral health management of adolescents is closely related to health behavior. Cessation of alcohol ingestion and smoking is very important to improve the adolescent oral health.

Fabrication and Characteristics of Amperometric NO2 Gas Sensors (전류검출형 NO2가스 센서의 제작과 특성평가)

  • Kim, Gwi-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.821-827
    • /
    • 2007
  • The nitrogen oxides, NO and $NO_2$, abbreviated usually as NOx, emitted from combustion facilities such as power plants and automobiles are the typical air-pollutants causing acid rain and photochemical smog. In order to solve the NOx-related pollution problems effectively, we need efficient techniques to monitor NOx in the combustion exhausts and in environments. Development of solid-state electrochemical devices for detecting NOx is demonstrated based on various combination of solid electrolytes and auxiliary sensing materials. The object of this research is to develop various sensor performance for solid state amperometric sensor, and to test gas sensor performance manufactured. So we try to present a guidance for developing amperometric gas sensor. We concentrated on development of manufacturing process and performance test. Amperometric Nitrogen dioxide sensor was fabricated using NASICON and an $NaNO_2$ layer deposited on the counter electrode. The current response was almost linear with Nitrogen dioxide concentration in the range 1-350 ppb at $150^{\circ}C$.

Zero Voltage Transition Full Bridge Boost Converter for Single Stage Power Factor Correction (Single Stage 역률보상을 위한 ZVT 풀 브릿지 부스트 컨버터)

  • Song, D.I.;Kwon, S.K.;Cho, J.G.;Back, J,W.;Kim, W.H.;Kim, J.S.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.351-354
    • /
    • 1996
  • A zero-voltage-transition(ZVT) full bridge (FB) boost converter for single stage power factor correction (PFC) in distributed power system is proposed. A simple auxiliary circuit provides zero-voltage-switching(ZVS) condition to all semiconductor devices without imposing additional voltage and current stresses and loss of PWM capability. The proposed boost converter provides both input power factor correction and direct conversion from $110{\sim}220VAC$ line to 300VDC bus with single power stage. Operational principle, analysis of the proposed converter are described and verified by computer simulation and experimental results from a 1.5 kW, 80 kHz laboratory prototype.

  • PDF

Feasibility Study of Tapped Inductor Filter Assisted Soft-Switching PWM DC-DC Power Converter

  • Moisseev S.;Sato S;Hamada S;Wakaoka M
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.231-234
    • /
    • 2003
  • This paper presents a novel high frequency transformer linked full-bridge type soft-switching phase-shift PWM control scheme DC-DC power converter, which can be used as power conditioner fur small-scale fuel cell power generation system. Using full-bridge soft-switching DC-DC converter topology makes possible to use low voltage high performance MOSFETs to achieve high efficiency of the power conditioner. A tapped inductor filter is implemented in the proposed soft-switching converter topology to achieve soft-switching PWM constant high frequency operation for a wide load variation range. to minimize circulating and idling currents without using additional resonant circuit and auxiliary power switching devices. The practical effectiveness of the proposed soft-switching DC-DC converter is verified in laboratory level experiment with 1 kW 100kHz breadboard setup using power MOSFETs. Actual efficiency of 94-96$\%$ is obtained for the wide load range

  • PDF

A New Multilevel Inverter of H-bridge Topology using Bidirection Switch (양방향 스위치를 이용한 H-bridge 구조의 새로운 멀티레벨 인버터)

  • Lee, Sang-Hyeok;Kang, Seong-Gu;Lee, Tae-Won;Hur, Min-Ho;Park, Sung-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.291-297
    • /
    • 2012
  • Recently, Switching devices become cheaper, depending on the multi-level inverters are considered as the power-conversion systems for high-power and power-quality demanding applications. The multi-level inverters can reduce the THD(Total Harmonic Distortion) as the output which is similar sinusoidal waveform by synthesizing several capacitor DC voltages. However it has some disadvantages such as increased number of components, complex PWM control method. Therefore, this paper is proposed the new multi-level inverter topology using an new H-bridge output stage with a bidirectional auxiliary switch. The proposed topology is the 4-level 3-phase PWM inverter with less switching part than conventional multi-level inverters and reactive power control possible. In order to understand the new multi-level inverter, topology analysis and switching patterns and modes according to the current loop are described in this paper. The proposed multi-level inverter topology is validated through PSIM simulation and the experimental results are provided from a prototype.

Roll-to-Roll Gravure Offset Printing System for Printed Electronics (인쇄전자를 위한 롤투롤 그라비아 옵셋 인쇄 장비)

  • Kim, Chung-Hwan;Choi, Byung-Oh;Ryu, Byung-Soon;Lim, Kyu-Jin;Lee, Myung-Hoon;Kim, Dong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.461-466
    • /
    • 2007
  • There has been a great interest in printing technology as a low cost and mass production method for the application of printed electronics such as printed TFT, solar cell, RFID Tag, printed battery, and so on. In this study, apparatuses of gravure-offset printing are developed for fine line-width/gap printing and examining pattern distortion occurred in gravure-offset printing process. The fine line-width/gap pattern shows that it is possible to make around 20 micro-meter line-width/gap printing patterns. Pattern distortion is modeled, and the amount and shape of the distortion are calculated by using commercial FEM code. The roll-to-roll printing system under development consists of unwinder/rewinder, two printing units, one coating unit, drying units, guiding unit, vision system, and other auxiliary devices. For multi-layer printing, the system is designed to be capable of printing two different materials.

  • PDF