• 제목/요약/키워드: Auxiliary Solution

검색결과 109건 처리시간 0.026초

Time-domain analyses of the layered soil by the modified scaled boundary finite element method

  • Lu, Shan;Liu, Jun;Lin, Gao;Wang, Wenyuan
    • Structural Engineering and Mechanics
    • /
    • 제55권5호
    • /
    • pp.1055-1086
    • /
    • 2015
  • The dynamic response of two-dimensional unbounded domain on the rigid bedrock in the time domain is numerically obtained. It is realized by the modified scaled boundary finite element method (SBFEM) in which the original scaling center is replaced by a scaling line. The formulation bases on expanding dynamic stiffness by using the continued fraction approach. The solution converges rapidly over the whole time range along with the order of the continued fraction increases. In addition, the method is suitable for large scale systems. The numerical method is employed which is a combination of the time domain SBFEM for far field and the finite element method used for near field. By using the continued fraction solution and introducing auxiliary variables, the equation of motion of unbounded domain is built. Applying the spectral shifting technique, the virtual modes of motion equation are eliminated. Standard procedure in structural dynamic is directly applicable for time domain problem. Since the coefficient matrixes of equation are banded and symmetric, the equation can be solved efficiently by using the direct time domain integration method. Numerical examples demonstrate the increased robustness, accuracy and superiority of the proposed method. The suitability of proposed method for time domain simulations of complex systems is also demonstrated.

고속전철 보조전원장치용 PWM 컨버터의 병렬운전에 관한 연구 (A Study on Parallel Operation of PWM Converter for Auxiliary Power Supply of High Speed Train)

  • 김연충;오근우;원충연;최종묵;기상우
    • 전자공학회논문지SC
    • /
    • 제37권6호
    • /
    • pp.64-72
    • /
    • 2000
  • 본 논문은 고속전철 보조전원장치에 사용되는 2대의 PWM 컨버터 병렬운전에 관하여 다루고 있다. 고역률을 이루고 변압기 1차측 전류 고조파 성분을 줄이기 위하여 3레벨 PWM 스위칭 방법에 의해 제어되는 AC/DC PWM 컨버터의 병렬운전을 제안하였다. 본 논문에서는 변압기의 결합효과를 제거하기 위한 제어기법과 컨버터 2대 사이의 위상전이기법 및 전원과 제어기를 동기화하기 위한 영점 검출방식을 나타내었다. TMS320C31 마이크로 프로세서와 10[kVA] PWM 컨버터로 구성된 축소시스템에 의한 실험 결과들은 제안된 알고리즘의 타당성을 보여주고 있다.

  • PDF

오차분석을 통한 개선된 EFG 균열해석기법의 해석계수 영향평가 (A Study on the Analysis Parameter Used in Improved EFG Crack Analysis Technique Based on Error Estimate)

  • 이상호;윤영철
    • 한국전산구조공학회논문집
    • /
    • 제15권4호
    • /
    • pp.703-713
    • /
    • 2002
  • 최근에 불연속 근사변위함수와 보조받침을 이용한 특이기저함수를 도입하여 균열의 불연속성과 특이성을 구현한 개선된 EFG(Element-Free Galerkin) 균열해석기법이 제안되었다. 개선된 EFG 균열해석기법은 균열의 성장에 따른 해석모형의 수정 없이도 높은 정확도로 균열전파해석을 수행할 수 있지만, 다른 무요소법과 마찬가지로 해석결과가 사용되는 해석계수에 의존하게 된다. 본 연구에서는 개선된 EFG 균열해석기법에서 사용하는 해석계수 즉, compact 받침 크기, 팽창계수, 선단주변에서의 형상함수의 평활화, 보조받침을 사용하는 절점개수가 수치해석 결과에 미치는 영향을 분석하였다. 균열문제에 대한 patch 시험을 통해 응력에 대한 L₂오차노름과 응력확대계수를 산정하여 해석계수의 영향을 분석하였으며, 그 결과는 해석계수의 선택에 대한 지침으로 제시된다.

The use of auxiliary devices during irrigation to increase the cleaning ability of a chelating agent

  • Prado, Marina Carvalho;Leal, Fernanda;Simao, Renata Antoun;Gusman, Heloisa;do Prado, Maira
    • Restorative Dentistry and Endodontics
    • /
    • 제42권2호
    • /
    • pp.105-110
    • /
    • 2017
  • Objectives: This study investigated the cleaning ability of ultrasonically activated irrigation (UAI) and a novel activation system with reciprocating motion (EC, EasyClean, Easy Equipamentos $Odontol\acute{o}gicos$) when used with a relatively new chelating agent (QMix, Dentsply). In addition, the effect of QMix solution when used for a shorter (1 minute) and a longer application time (3 minutes) was investigated. Materials and Methods: Fifty permanent human teeth were prepared with K3 rotary system and 6% sodium hypochlorite. Samples were randomly assigned to five groups (n = 10) according to the final irrigation protocol: G1, negative control (distilled water); G2, positive control (QMix 1 minute); G3, QMix 1 minute/UAI; G4, QMix 1 minute/EC; G5, QMix 3 minutes. Subsequently the teeth were prepared and three photomicrographs were obtained in each root third of root walls, by scanning electron microscopy. Two blinded and pre-calibrated examiners evaluated the images using a four-category scoring system. Data were statistically analyzed using Kruskal-Wallis and Dunn tests (p < 0.05). Results: There were differences among groups (p < 0.05). UAI showed better cleaning ability than EC (p < 0.05). There were improvements when QMix was used with auxiliary devices in comparison with conventional irrigation (p < 0.05). Conventional irrigation for 3 minutes presented significantly better results than its use for 1 minute (p < 0.05). Conclusions: QMix should be used for 1 minute when it is used with UAI, since this final irrigation protocol showed the best performance and also allowed clinical optimization of this procedure.

Electrocoagulation of Disperse Dyebath Wastewater: Optimization of Process Variables and Sludge Production

  • Aygun, Ahmet;Nas, Bilgehan;Sevimli, Mehmet Faik
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권1호
    • /
    • pp.82-91
    • /
    • 2021
  • This study was conducted to investigate the effect of initial pH, current density, and electrolysis time on process performance in terms of decolorization and chemical oxygen demand (COD) removal from disperse dyebath wastewater (DDW) by mono-polar parallel laboratory scale electrocoagulation (EC) process. COD reduction of 51.3% and decolorization of 92.8% were obtained with operating cost of 0.19 €/㎥ treated wastewater for Al-Al electrode pair, while 90.5% of decolorization and 49.2% of COD reduction were obtained with operating cost of 0.20 €/㎥ treated wastewater for an Fe-Fe electrode pair. The amount of sludge production were highly related to type of the electrode materials. At the optimum conditions, the amount of sludge produced were 0.18 kg/㎥ and 0.28 kg/㎥ for Al-Al and Fe-Fe electrode pairs, respectively. High decolorization can be explained by the hydrophobic nature of the disperse dye, while limited COD removal was observed due to the high dissolved organic matter of the DDW based on auxiliary chemicals. Energy, electrode, and chemical consumptions and sludge handling were considered as major cost items to find a cost-effective and sustainable solution for EC. The contribution of each cost items on operating cost were determined as 10.0%, 51.1%, 30.5% and 8.4% for Al-Al, and they were also determined as 9.0%, 38.0%, 40.5% and 12.5% for Fe-Fe, respectively. COD reduction and decolorization were fitted to first-order kinetic rule.

BLOW-UP PHENOMENA FOR A QUASILINEAR PARABOLIC EQUATION WITH TIME-DEPENDENT COEFFICIENTS UNDER NONLINEAR BOUNDARY FLUX

  • Kwon, Tae In;Fang, Zhong Bo
    • 충청수학회지
    • /
    • 제31권3호
    • /
    • pp.287-308
    • /
    • 2018
  • This paper deals with blow-up phenomena for an initial boundary value problem of a quasilinear parabolic equation with time-dependent coefficient in a bounded star-shaped region under nonlinear boundary flux. Using the auxiliary function method and differential inequality technique, we establish some conditions on time-dependent coefficient and nonlinear functions for which the solution u(x, t) exists globally or blows up at some finite time $t^*$. Moreover, some upper and lower bounds for $t^*$ are derived in higher dimensional spaces. Some examples are presented to illustrate applications of our results.

견실성능 최적화를 위한 혼합 H_2/H_{\infty}$ 제어기설계 알고리즘 (Mixed H_2/H_{\infty}$ controller design algorithm for robust performance optimization)

  • 김종해;방경호;박홍배
    • 전자공학회논문지B
    • /
    • 제33B권5호
    • /
    • pp.10-16
    • /
    • 1996
  • In this paper, we consider a generalized mixed H_2/H_{\infty}$ output feedback problem. It is finding an internally stabilizing controller that minimizes a mixed $H_{2}$/ $H_{performance}$ measure. We show that a generalized mixed H_2/H_{\infty}$ system with two exogenous inputs and two controlled signals is transformed into auxiliary system with two exogenous inputs and one controlled signal. The two systems have equivalent performance. Therefore, a complete solution of generalized mixed H_2/H_{\infty}$ output feedback problem is achieved by existing results of mixed H_2/H_{\infty}$ control theory.

  • PDF

Optimal Sampling Plans of Reliability Using the Complex Number Function in the Complex System

  • Oh, Chung Hwan;Lee, Jong Chul;Cho, Nam Ho
    • 품질경영학회지
    • /
    • 제20권1호
    • /
    • pp.158-167
    • /
    • 1992
  • This paper represents the new techniques for optimal sampling plans of reliability applying the mathematical complex number(real and imaginary number) in the complex system of reliability. The research formulation represent a mathematical model Which preserves all essential aspects of the main and auxiliary factors of the research objectives. It is important to formule the problem in good agreement with the objective of the research considering the main and auxilary factors which affect the system performance. This model was repeatedly tested to determine the required statistical chatacteristics which in themselves determine the actual and standard distributions. The evaluation programs and techniques are developed for establishing criteria for sampling plans of reliability effectiveness, and the evaluation of system performance was based on the complex stochastic process(derived by the Runge-Kutta method. by kolmogorv's criterion and the transform of a solution to a Sturon-Liouville equation.) The special structure of this mathematical model is exploited to develop the optimal sampling plans of reliability in the complex system.

  • PDF

Mode Decomposition of Three-Dimensional Mixed-Mode Cracks using the Solution for Penny-Shaped Crack

  • Kim, Young-Jong;Cho, Duk-Sang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제2권3호
    • /
    • pp.11-18
    • /
    • 2001
  • A simple and convenient method of analysis for obtaining the individual stress intensity factors in a three-dimensional mixed mode crack is proposed. The procedures presented here are based on the path independence of J integral and mutual or two-state conservation integral, which involves two elastic fields. The problem is reduced to the determination of mixed mode stress intensity factor solutions in terms of conservation integrals involving known auxiliary solutions. Some numerical examples are presented to investigate the effectiveness and applicability of the method for a three-dimensional penny-shaped crack problem under mixed mode. This procedure is applicable to a three-dimensional mixed mode curved crack.

  • PDF

Nonisolated Two-Phase Bidirectional DC-DC Converter with Zero-Voltage-Transition for Battery Energy Storage System

  • Lim, Chang-Soon;Lee, Kui-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2237-2246
    • /
    • 2017
  • A nonisolated two-phase bidirectional dc-dc converter (NTPBDC) is a very attractive solution for the battery energy storage system (BESS) applications due to the high voltage conversion ratio and the reduced conduction loss of the switching devices. However, a hard-switching based NTPBDC decreases the overall voltage conversion efficiency. To overcome this problem, this paper proposes a novel NTPBDC with zero-voltage-transition (NTPBDC -ZVT). The soft-switching for the boost and buck main switches is achieved by using a resonant cell, which consists of a single resonant inductor and four auxiliary switches. Furthermore, due to the single resonant inductor, the proposed NTPBDC-ZVT has the advantages of simple implementation, reduced size, and low cost. The validity of the proposed NTPBDC-ZVT is verified through experimental results.