• Title/Summary/Keyword: Auxiliary Heater

Search Result 31, Processing Time 0.024 seconds

Experimental Study on the Heating Performances of the Air Heater with Diesel for Passenger Cabin Heating of an Electric Vehicle (전기자동차용 승차공간 난방용 디젤 공기 히터의 실차 성능에 관한 연구)

  • Bang, You-Ma;Seo, Jae-Hyeong;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7250-7255
    • /
    • 2015
  • The objective of this study is to experimentally investigate the heating performances of the portable air combustion heater using diesel fuel for auxiliary cabin heating of the battery electric vehicle. In order to evaluate the heating performances of the air combustion heater, the heating capacity was calculated by the temperature at inlet and outlet parts of the considered heater and the inner temperature distribution characteristics of the vehicle were measured during 1600 seconds with an interval of 1 second. The theoretical efficiency of the tested heater was calculated by temperature data of the air of supplying and exhausting to the cabin. As the air passed the heat-sink, the air temperature at the end of heat-sink reached to $101.3^{\circ}C$ and the difference of temperature on heat-sink was 67.8%. The average heating capacity of the air combustion heater showed 2.0 kW. After 1800 seconds, the inner temperature of the vehicle cabin was continuously increased. The temperatures of the top side and the bottom side of the car cabin under consideration were increased upto $42.5^{\circ}C$ and $24.3^{\circ}C$, respectively, and the theoretical efficiency of the tested heater was on average 63.7%.

Experimental Study on the Thermal Performance of a Domestic Solar Air Heater with Protruding Triangular Openings on the Absorber Plate (흡열판에 돌출형 삼각 개구부가 설치된 가정용 태양열 공기가열기의 열성능에 대한 실험적 연구)

  • Kim, Hyun Gon;Boo, Joon Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.41-51
    • /
    • 2016
  • A solar air heater was designed for supplementary domestic heating. The absorber plate had a series of protruding notches which had triangular openings on the front surface of the absorber plate to direct partial air flow to the rear surface and to enhance the convective heat transfer to the flowing air. The height of the opening as well as the opening configuration was determined by preceding numerical simulations. The experimental model had an absorber plate of 0.78-m width and 1.0-m length which was coated with black paint. The air temperature increased as much as $18^{\circ}C$ for $90-m^3/h$ flow rate when the absorber plate was inclined by $45^{\circ}$ for a clear-day solar irradiation of about $906W/m^2$. The collector efficiency ranged from 69 to 74%. Considering the simplicity of the structure and low manufacturing cost, the solar air heater might have competence as an auxiliary heating device for domestic use. On-site experimental results are presented with discussion for various solar irradiations and air flow conditions.

A Novel Induction Heating Type Super Heated Vapor Steamer using Dual Mode Phase Shifted PWM Soft Switching High Frequency Inverter

  • Sugimura, Hisayuki;Eid, Ahmad;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.774-777
    • /
    • 2005
  • In this paper, a constant frequency phase shifting PWM controlled voltage source full bridge-type series load resonant high-frequency inverter using the IGBT power modules is presented for innovative consumer electromagnetic induction heating applications such as a hot water producer, steamer and super heated steamer. The full bridge arm side link passive quasi-resonant capacitor snubbers in parallel with the each power semiconductor device and high frequency AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is discussed and evaluated on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency soft switching PWM inverter topology, what is called class DE type. including the variable-power variable-frequency(VPVF) regulation function can expand zero voltage soft switching commutation range even under low output power setting ranges, which is more suitable and acceptable for induction heated dual packs fluid heater developed newly for consumer power utilizations. Furthermore, even in the lower output power regulation mode of this high-frequency load resonant tank high frequency inverter circuit it is verified that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.

  • PDF

Effect of Heating by Infrared Heating Lamps on Growth of Strawberry and Heating Cost (적외선 난방등을 이용한 난방이 딸기의 생육과 난방비에 미치는 영향)

  • An, Jae Uk;An, Chul Geon;Hwang, Yeon Hyeon;Yoon, Hae Suk;Chang, Young Ho;Shon, Gil Man;Jeong, Byoung Ryong
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.355-360
    • /
    • 2013
  • Diesel-burning air heater (air heater) and infrared heating lamp (infrared heater) were installed as auxiliary heaters in two single water-curtained plastic greenhouses with a set night temperature of $6^{\circ}C$ for cultivation of strawberry 'Seolhyang'. The average night air temperature was $6.6^{\circ}C$ in the infrared heater treatment and $7.1^{\circ}C$ in the air heater treatment. However, when the minimum outside temperature fell below $-10^{\circ}C$, the air heater had less internal temperature fluctuations. In contrast, the infrared heater had some cases of falling below the set temperature. The relative humidity was higher than 98% by the side-effect of water-curtain system regardless of the heating system. There was about $5^{\circ}C$ difference in leaf temperature between the turned-on and -off state of the infrared heater, and the efficacy of the infrared heater on leaf temperature was only limited to about 4 meters from the system. Peduncle length and plant height in the infrared heater tended to be greater than those in the air heater. There was, however, no statistically difference in leaf size and numbers of leaves, flowers on first cluster and branches. There was no difference in soluble solids content, fruit firmness, average fruit weight of the harvested fruits, and the yield. Comparing the heating costs, the air heater system took 622,662 won based on 543 L tax-free diesel, while the infrared heater system took 235,284 won by consuming 5,685 kWh of electricity, and 62.2% heating costs saving was achieved.

Power System Design for Next Generation LEO Satellite Application (차세대 저궤도 소형위성 적용을 위한 전력시스템 설계)

  • Park, Sung-Woo;Park, Hee-Sung;Jang, Jin-Beak;Jan, Sung-Soo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.283-287
    • /
    • 2005
  • In this paper, one general approach is proposed for the design of power system that can be applicable for next generation LEO satellite application. The power system consists of solar panels, battery, and power control and distribution unit(PCDU). The PCDU contains solar array modules, battery interface modules, low-voltage power distribution modules, high-voltage distribution modules, heater power distribution modules, on-board computer interface modules, and internal DC/DC converter modules. The PCDU plays roles of protection of battery against overcharge by active control of solar array generated power, distribution of unregulated electrical power via controlled outlets to bus and instrument units, distribution of regulated electrical power to selected bus and instrument units, and provision of status monitoring and telecommand interface allowing the system and ground operate the power system, evaluate its performance and initiate appropriate countermeasures in case of abnormal conditions. We review the functional schemes of the main constitutes of the PCDU such as the battery interface module, the auxiliary supply module, solar array regulators with maximum power point tracking(MPPT) technology, heater power distribution modules, spacecraft unit power distribution modules, and instrument power distribution module.

  • PDF

Cooling and Heating Characteristics of System A/C using the Digital Scroll Compressor (디지털 스크롤 압축기를 이용한 시스템 에어컨의 냉난방특성)

  • Jun, Young-Ho;Kim, Dae-Hun;Kweon, Young-Chel;Lee, Yun-Su;Moon, Je-Myung;Hong, Ju-Tae
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1536-1541
    • /
    • 2003
  • In order to investigate the cooling and heating characteristics of a variable-capacity system A/C using a digital scroll compressor, the cooling and heating capacities and EER are measured by the psychrometric calorimeter. The capacity of the system is controlled by the digital scroll compressor, which is operated by controling PWM valve and the loading vs. unloading time. When the system A/C is operated under the cooling and heating standard conditions, EER is nearly uniform but cooling capacity and heating capacity increase at minimum, rated and maximum modes. When the auxiliary heater is on, at the cold region, the system A/C produces the excellent heating capacity.

  • PDF

A Study on the Performance of Cooling/Reheating System Using Polymer Heat Exchanger (폴리머 열교환기를 사용한 냉각/재가열 시스템의 성능에 관한 연구)

  • Kim, Jin-Hyuck;Yoo, Seong-Yeon;Han, Kyu-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2154-2159
    • /
    • 2008
  • In conventional air-conditioning systems, when the circulated air from the air-conditioned space pass through the cooling coil in the air-conditioning system, the air is over-cooled to eliminate the moisture as well as to decrease the temperature. The purpose of this study is to test and evaluate performance of the cooling/reheating system which can save both cooling energy and reheating energy by exchanging heat between the cooled air and reheated air. Experimental apparatus consists of fan, ducts, polymer exchangers, cooling coil, electronic auxiliary heater and data acquisition system. Two types of polymer exchanger, plate type and dimple type, made of polypropylene for cooling/reheating system are designed. Heat transfer and dehumidification characteristics of system are tested. The results show that the energy saving is up to 40% in the range of present experimented conditions, and it decreases with increasing velocity, inlet temperature and specific humidity.

  • PDF

Preliminary Design of a Power Control and Distribution Unit for a Small LEO Satellite Application (소형 저궤도 위성적용을 위한 전력조절분배기 예비설계)

  • Park, Sung-Woo;Park, Hee-Sung;Jang, Jin-Baek;Jang, Sung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1438-1440
    • /
    • 2005
  • A power control and distribution unit(PCDU) plays roles of protection of battery against overcharge by active control of solar array generated power, distribution of unregulated electrical power via controlled outlets to bus and instrument units, distribution of regulated electrical power to selected bus and instrument units, and provision of status monitoring and telecommand interface allowing the system and ground operate the power system, evaluate its performance and initiate appropriate countermeasures in case of abnormal conditions. In this work, we perform the preliminary design of a PCDU scheme for the small LEO Satellite applications. The main constitutes of the PCDU are the battery interface module, the auxiliary supply modules, solar array regulators with maximum power point tracking(MPPT) technology, heater power distribution modules, internal converter modules for regulated bus voltage generation. and instrument power distribution modules.

  • PDF

Development of f-chart for the Design of Solar Heating Systems (태양열난방장치 설계를 위한 f-chart 개발)

  • Song Dal-Sun;Yoo Seong-Yeon
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.3
    • /
    • pp.292-298
    • /
    • 1986
  • The new f-chart capable of estimating long-term thermal performance of solar space and water heating systems was developed. The system comprise a flat plate solar collector, heat exchanger, storage tank filled with water, auxiliary fuel fired heater, and a house structure. The information obtained from many simulations of solar heating systems has been used to develop this f-chart. Actual hourly meteorological data collected in Seoul, Daejeon, Kwangju and Daegu, Korea from 1979 to 1983 have been utilized in these simulations. The new f-equation is as follows: $$f=1.034Y_{-}0.0968X_{-}0.2235Y^2+0.0043X^2+0.0144Y^3$$. The system performance estimates obtained from the developed f-chart are in close agreement with the results of experiment.

  • PDF