• Title/Summary/Keyword: Automatic analysis system

Search Result 1,687, Processing Time 0.032 seconds

A Study on the Experimental Analysis of the Automatic Fine Polishing System (자동 경면 다듬질 장치의 실험적 분석에 관한 연구)

  • Park, Gyun Myoug;Jang, Jin Hee;Han, Chang Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.9
    • /
    • pp.30-39
    • /
    • 1995
  • Now a days, securing skilled workers is very difficult due to the hardworking environment. This situation will be getting worse in the future and also that makes the dies/molds industries difficult. In this research, the automatic fone polishing system which can be directly attached to the spindle of CNC machine is proposed and analyzed. The system is also controlled by the NC progra data created by CAD/CAM system. The usefulness and effectiveness of the developed system are verified more detail through some comparisons between automatic and manual polishing experiments. The experiments show that the automatic polishing is a more useful and effective process than manual one. For the application, this system can be easily used for the polishing process in the area of any fine surface.

  • PDF

Automatic Titration Using PC Camera in Volatile Basic Nitrogen Analysis by Microdiffusion Method (미량확산법에 의한 휘발성염기질소 분석에서 PC카메라를 이용한 자동적정)

  • Lee, Hyeong-Choon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.1
    • /
    • pp.135-137
    • /
    • 2005
  • A PC-based automatic system was developed for automatic titration in volatile basic nitrogen analysis by the microdiffusion method. The system used a CCD-type PC camera for the automatic detection of the titration end point. The camera checked whether the green value of a pixel on the red image of titrated solution became greater than the red value. The data from the automatic titration using the system were not significantly different (p>0.05) from those taken by manual titration. The agreement between means of data from manual titration and those from automatic titration was good.

A Development of the Noise Quality Checking System EOL of the 6th Speed Automatic Transmission in the USA (북미 6속 자동변속기 공장 EOL NVH 시스템 개발에 대한 연구)

  • Lee, Hyun-Ku;Kim, Moo-Suk;Hwang, Seon-Yang;Kang, Koo-Tae;Lee, Tae-Hwi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.731-732
    • /
    • 2011
  • This paper shows a whole noise quality checking system for the new developed 6th speed automatic transmission manufactured in USA. Due to demand for manufacturing of the high NVH quality transmissions in the mass product line, some special checking system called EOL is adapted. This EOL system is using vibration analysis technologies. Through adapting vibration analysis technologies and functions likewise RMS, Crest Factor, Harmonics, Peak, Band, and Order tracking, various noise problems caused by wear, nick, and deformations could be successfully detected and predicted. Therefore, automatic transmissions manufactured in the USA could get high NVH quality.

  • PDF

Analysis of OHC drive timing belt system behavior for fixed and automatic tensioner (고정 및 자동장력식 텐셔너에 대한 OHC 구동 타이밍 벨트 시스템의 거동해석)

  • 김현수;이인환;여창기
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.79-89
    • /
    • 1992
  • The behavior of belt tension in OHC drive timing belt system was investigated analytically and experimentally for (1)fixed and (2)automatic tensioner. From the numerical results it was found that the automatic tensioner makes the belt tension larger than those of the fixed tensioner. When the initial belt tension decreased due to the belt elongation, the belt tension of the fixed tensioner could decrease to near zero while the belt tension for the automatic tensioner maintained above zero by the tensioner spring. The mean valve and the difference between the maximum and the minimum belt tension for the automatic tensioner increased compared with those of the fixed tensioner. Also, the numerical results for a hydraulic tensioner showed that the hydraulic tensioner has the good parts of both tensioners; i.e., thesmaller amplitude in belt tension and the higher mean tension. Experimental results for the automatic and fixed tensioner of the OHC timing belt system were in agreement with the theoretical results.

  • PDF

Development of the Automatic Control System for the Advanced Phosphorus Treatment in Sewage Treatment Plant (하수처리시설에서 인 고도처리를 위한 자동제어시스템 개발에 관한 연구)

  • Kim, Seon-Gok;Lee, Ho-Sik;Jun, Tae-Sung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.300-304
    • /
    • 2012
  • It has a limitation to satisfy the phosphorus effluent criteria of 0.2 mg/L which will be reinforced from 2012 with the Biological Nutrient Removal (BNR) process. The chemical coagulation process has been operated in parallel with the biological treatment process for advanced treatment of phosphorous in the developed countries including Europe. However, the coagulation process has some disadvantages such as the desired goal may not be achieved without injecting the optimum dosage of the coagulant. This study developed the automatic control system to inject the optimum dosage of phosphorous coagulant into the coagulation process. The adopted coagulant was 10% Poly Aluminum Chloride (PAC) in this study. The automatic control system developed in this study was adopted for the treatment of the phosphorus from the effluent in SBR process. The automatic control system was composed of the data receiving part, the optimum coagulant dosage control part and the data transmit part. The result of the phosphorous advanced treatment of the SBR effluent using the automatic control system showed the removing efficiency over 95% consistently with the phosphorous concentration under 0.02 ~ 0.15 mg/L. The reproducibility analysis for checking the safety of automatic control system showed more than 95% correlation.

A Case Study on the Field Monitoring of the Deep Rock Excavation Site in Urban Area on Severe Unbalanced Pressure Condition (편토압이 심한 도심지 대심도 암반굴착공사에서의 계측사례)

  • Kim, Tae-Seob;Kim, Woong-Kyu;Jung, Chang-Won;Han, Chul-Hee
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1259-1267
    • /
    • 2008
  • One of the most important item for insuring the stability of ground in urban deep excavation site near by major structure such as subway is displacement control of earth retaining wall. The field monitoring system is classified by two types as manual system and automatic system. The application case of latter type of field monitoring is increased because real time measurement is possible in automatic system and that is correspondent with the recent constructional trend. Though the automatic monitoring system is more useful and advanced than manual monitoring system, accuracy of the system is not verified sufficiently. It was examined that the reliance of automatic monitoring system in this paper through the comparison of monitoring result obtained one of deep urban excavation site in which the each type of monitoring system was executed concurrently. Result of the examination is that the two types of monitoring system is generally alike in view of monitoring result, so the engineering reliance of automatic system was confirmed in case site. This study was researched in restricted one case site, so it is expected more precise analysis from security of more data monitored and progressive study.

  • PDF

A Development of the Performance Analysis Program Package of the Automatic Temperature Control System for Heating (난방용 자동온도조절기 성능분석용 프로그램 및 패키지 개발)

  • Kim, Yong-Ki;Woo, Nam-Sub;Lee, Tae-Won;Ahn, Byung-Cheon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1209-1214
    • /
    • 2009
  • Various automatic temperature control systems have been used widely in Korea for the conservation of heating energy and the enhancement of thermal comfort in residential buildings. But the heating control performance for automatic temperature control systems extensively vary with the design and operational conditions of the heating system, the climate condition and others. It was introduced in this study a numerical calculation program package to analyze heating control characteristics of the automatic temperature control system. This package is able to analyze the room air temperature, return water temperature, supplied heating flux and flow rate, and so on. One the other hand, the simulation results were verified by comparing with the field test results.

  • PDF

Analysis of the system requirements by EMU operating types (도시철도 운전형태별 시스템 구비요건 분석 연구)

  • Hong, Yong-Ki;Chung, Jong-Duk;Pyun, Jang-Sik
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.536-543
    • /
    • 2008
  • When the electric motor car was first introduced, an engineer, responsible for the work related to operation and a conductor for the announcement and management of entrances and the other services like as monitoring the passengers in the platforms used to take together the train for passengers' safe. As new technologies developed and the urban transit system had the automatic driving facilities, automatic door switch and broadcasting systems, to solve the financial problems, most subway systems introduced the one-man operation system. To curtail the operating expense through automatic control and operation for the economical efficiency, the crewless driving system was introduced abroad around 1970 on the light weight train and Japan started the crewless driving system in 2005, Germany started it in June 2008. We examine system requirements of the system and methods to construct safe systems that would be introduced, suitable for one-man operation system or crewless driving system through the surveys and analysis of driving state and the systems.

  • PDF

Automatic Video Management System Using Face Recognition and MPEG-7 Visual Descriptors

  • Lee, Jae-Ho
    • ETRI Journal
    • /
    • v.27 no.6
    • /
    • pp.806-809
    • /
    • 2005
  • The main goal of this research is automatic video analysis using a face recognition technique. In this paper, an automatic video management system is introduced with a variety of functions enabled, such as index, edit, summarize, and retrieve multimedia data. The automatic management tool utilizes MPEG-7 visual descriptors to generate a video index for creating a summary. The resulting index generates a preview of a movie, and allows non-linear access with thumbnails. In addition, the index supports the searching of shots similar to a desired one within saved video sequences. Moreover, a face recognition technique is utilized to personalbased video summarization and indexing in stored video data.

  • PDF

A Study on Functional Analysis of Advanced EMU used by System Engineering Design Tool (전산지원도구를 이용한 차세대전동차 기능분석 연구)

  • Lee, Woo-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1663-1665
    • /
    • 2005
  • The urban transit system is operated by driverless and automatic. In driverless and automatic system, the system function is accomplished exactly to obtain the safety and reliability of system and the system is designed to minimize risk. In order to design the system, the functional analysis is performed. Recently functional analysis is performed by design tool which is used and verified by aerospace, military, etc. Generally, the design tool is used to perform functional analysis in urban transit system development project. The design toolassist the system engineer to analysis the function of system in basic design. Therefore, in this paper, it is performed the functional analysis to satisfy the system requirement of urban transit system and to confirm the operation of system using design tool.

  • PDF