• Title/Summary/Keyword: Automatic Water Management

Search Result 158, Processing Time 0.026 seconds

Underwater Environment Information Acquisition System in Coastal Area based on CDMA Network (CDMA망 기반 해안지역의 수중 환경정보 수집시스템)

  • Kim, Jae-Gyeong;An, Seong-Mo;Lee, Chang-Hee;Ock, Young-Seok;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.187-190
    • /
    • 2011
  • Until now, water pollution environmental monitoring system has been used at to acquire and measure data for streams and rivers. Recently coastal and marine environment monitoring system is becoming most important and urgent thing. The realtime automatic coastal and marine environment monitoring system using CDMA data transmission technique is developed in this study. The Embedded field server is designed and developed to acquire and measure underwater environment information such as pH, DO, water temperature using the water quality sensor. The obtained data is sent to the server via CDMA modem connected to the embedded field server and stored in database. Our purpose is to provide and monitor underwater environment information with CDMA communication in coastal areas.

  • PDF

Determination of EMC and Unit Loading of Rainfall Runoff from Forestry-Crops Field (산림과 밭 지역 강우 유출수의 EMC 및 원단위 산정)

  • Won, Chul-hee;Choi, Yong-hun;Seo, Ji-yeon;Kim, Ki-cheol;Shin, Min-hwan;Choi, Joong-dae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.615-623
    • /
    • 2009
  • The research of the determination of event mean concentration (EMC) was focussed combined sewer overflows and highway runoff in korea. But those of non-urban areas are few. In this study, EMC and unit loading on land use types in Nogok watershed were estimated by runoff loading of non-point source (NPS) on non-urban area. Two monitoring sites were equipped with an automatic velocity meter, flow meter, and water sampler. Monitoring was conducted at two monitering site during the rainy season. The results show that the EMC ranges in forest land use are 1.3~2.6 mg/L for BOD, 2.0~16.1 mg/L for SS, 0.1~2.1 mg/L for TN, and 0.12~0.49 mg/L for TP. The unit loading of NPS in this study was difficult to compare directly with that used conventionally because of the difference of field investigation. In near future, it needs to conduct more systematic and long-term research about NPS within the watershed. The results of this research can be used to estimate the total pollution load management system (TPLMS) program in korea.

Study on the Swine Farming Facilities by Survey for the Development of the Optimum Production System Models (최적화 생산시스템 모델 개발을 위한 양돈시설의 조사 연구)

  • 장동일;이봉덕;조한근;장홍희
    • Journal of Animal Environmental Science
    • /
    • v.2 no.1
    • /
    • pp.1-11
    • /
    • 1996
  • This study was conducted to analyze the present status and the levels of mechanization and automation for raising, feeding, water supply, propagation, health management, ventilation and heat control, data analysis, and etc, and to establish the guide of the future study on development of the optimum production system models of swine facility from the results of this analysis. The scheme of the future study on the development of the optimum production system model of swine facility was established as follows : 1. A Korean and environmental control type slatted windowless swine housing model would be developed according to the following basis : \circled1 Boars, gilts and sows, delivery sows should be raised individually and piglets, growing pigs, and finishing pigs should be raised in group. \circled2 The arrangement of furrowing house were two rows of furrowing crates facing the center aisle. 2. The environmental control system and waste management system that are suitable to Korean and environmental control type slatted windowless swine housing model would be developed. 3. An electronic identification device would be developed. 4. The automatic individual wet feeding system by electronic identification device and computers would be developed. 5. The individual management system would be developed, which could manage individually the breeding pigs by the electronic identification device. 6. An expert system would be developed, which could manage the health and data base of pigs.

  • PDF

Status of Automatization in Protected Horticultural Facilities and Prospect of Plant Factory in Korea (한국의 원예시설 자동화 현황 및 식물공장의 발전방향)

  • 윤진하
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1996.05a
    • /
    • pp.91-115
    • /
    • 1996
  • In the recent years, protected horticultural facilities have been modernized and glasshouses are also propagating in Korea, even most vegetables production are conducted in the traditional plastic houses covered with, for example, PVC film for just temperature keeping. It would limit the productivity and competitivity of the vegetable production industry without automatization and high quality year round production. A plant factory, aimed to produce vegetables in the limited areas, was initiated in Christensen farm, Denmark in 1957, and widely propagated in some developed countries. As it has the automatized system which enables to keep optimized environment conditions, it will be the best facility for high quality products as well as year round planned production. However, we have not even started the plant factory production. Since the plant factory is requiring lots of resources, besides plant cultivation technologies, such as environment control, automatic engineering and robotics, our approach to the development of plant factories should be minded on Practical Plant Factories considering our current farming practices and least capital needs rather than blindly employing the advanced technologies from developed countries. Thus, Korean plant factory development can be initiated with year round leaf vegetables production in NFT or DFT cultivation system instead of the moval bed system, in which aerial environment factors such as light, temperature, humidity and CO$_2$ concentration and root environment ones such as solution concentration, temperature, pH and water soluble oxygen shall be automatically controlled. And the seeding, seedling and transplanting operations shall be accomplished in the house entrance, and the harvesting and grading opreations shall be conducted in the house exit. For practical plant factories, environment control technologies including artificial light source, illumination and air conditioning, automatic management for nutrient solution and automatic production line of moval bed system, transplanting and harvest should be developed along with researches on the cost reduction of factory building construction.

  • PDF

The Effective Approach for Non-Point Source Management (효과적인 비점오염원관리를 위한 접근 방향)

  • Park, Jae Hong;Ryu, Jichul;Shin, Dong Seok;Lee, Jae Kwan
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.140-146
    • /
    • 2019
  • In order to manage non-point sources, the paradigm of the system should be changed so that the management of non-point sources will be systematized from the beginning of the use and development of the land. It is necessary to change the method of national subsidy support and poeration plan for the non-point source management area. In order to increase the effectiveness of the non-point source reduction project, it is necessary to provide a minimum support ratio and to provide additional support according to the performance of the local government. A new system should be established to evaluate the performance of non-point source reduction projects and to monitor the operational effectiveness. It is necessary to establish the related rules that can lead the local government to take responsible administration so that the local governments faithfully carry out the non-point source reduction project and achieve the planned achievement and become the sustainable maintenance. Alternative solutions are needed, such as problems with the use of $100{\mu}m$ filter in automatic sampling and analysis, timely acquisition of water sampling and analysis during rainfall, and effective management of non-point sources network operation management. As an alternative, it is necessary to consider improving the performance of sampling and analysis equipment, and operate the base station. In addition, countermeasures are needed if the amount of pollutant reduction according to the non-point source reduction facility promoted by the national subsidy is required to be used as the development load of the TMDLs. As an alternative, it is possible to consider supporting incentive type of part of the maintenance cost of the non-point source reduction facility depending on the amount of pollutants reduction.

Analysis of Abnormal Values Obtained from National Groundwater Monitoring Stations (국가지하수 관측소 측정자료의 이상값 분석)

  • Yi Myeong-Jae;Lee Jin-Yong;Kim Gyoo-Bum;Won Jong-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.1
    • /
    • pp.65-74
    • /
    • 2005
  • National groundwater monitoring stations have been managed throughout the country by Korea Water Resources Corporation (KOWACO) in order to monitor variations in quantity and quality of groundwater resources. A multi-sensor installed in each monitoring station well measures groundwater level, water temperature and electrical conductivity every six hours and the logged data are automatically transmitted to a host computer in KOWACO. Meanwhile despite regular station inspection and replacement of deteriorate or broken devices, abnormal values or outliers often occur due to intrinsic limitations of automatic monitoring and transmission. Thus prompt recognition and measures to these values are essentially required to reduce disturbance and missing period of the data. In this study, time and frequency of outlier occurrence were analyzed for the water level data obtained from national groundwater monitoring stations within the Han river basin in 2000. The analysis results indicated that the most prominent patterns of the outliers were rapid decline for water level, no variation for temperature and steep decline for electrical conductivity. This study provided a sample criterion for determining the outlier for each parameter.

Analysis of Automatic Meter Reading Systems (IBM, Oracle, and Itron) (국외 상수도 원격검침 시스템(IBM, Oracle, Itron) 분석)

  • Joo, Jin Chul;Kim, Juhwan;Lee, Doojin;Choi, Taeho;Kim, Jong Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.264-264
    • /
    • 2017
  • 국외의 상수도 원격검침 시스템 내 데이터 전송방식은 도시 규모, 계량기의 밀도, 전력공급 여부 및 통신망의 설치 여부 등을 종합적으로 고려하여 결정되었다. 대부분의 스마트워터미터 제조업체들은 계량기의 부호기가 공급하는 판독 내용(데이터)을 전송할 검침단말기와 근거리 통신망(neighborhood area network)을 연계하여 개발 및 판매하였으며, 자체 소유 통신 프로토콜을 사용하여 라디오 주파수(RF) 통신 기술을 사용하고 있다. 광역통신망(wide area network)의 경우, 노드(말단의 계량기 및 센서)들과 이에 연결된 통신망 들을 포함한 네트웍의 배열이나 구성이 스타(star), 메쉬(mesh), 버스(bus), 나무(tree) 등의 형태로 통신망이 구성되어 있으나, 스타와 메쉬형 통신망 구성형태가 가장 널리 활용되는 것으로 조사되었다. 시스템 통합운영관리 업체들인 IBM, Oracle, Itron 등은 용수 인프라 관리 또는 통합네트워크 솔루션 등의 통합 물관리 시스템(integrated water management system)을 개발하여 현장적용을 하고 있으며, 원격검침 시스템을 통해 고객들의 현재 소비량과 과거 누적 소비량, 누수 감지 서비스 및 실시간 요금 고지 등을 실시간으로 웹 포털과 앱을 통해 제공하고 있다. 또한, 일부 제조업체들은 도시 용수공급/소비 관리자가 주민의 용수사용량을 모니터링하여 일평균 용수사용량 및 사용 경향을 파악하고, 누수를 검지하여 복구 및 용수 사용 지속가능성 지수를 제시하고, 실시간으로 주민의 용수사용량 관련 데이터를 모니터링하여 용수공급의 최적화를 위한 의사결정지원 서비스를 용수공급자에게 제공하고 있다. 최근에는 인공지능을 활용해 가정용수의 용도별(세탁용수, 화장실용수, 샤워용수, 식기세척용수 등) 사용량 곡선을 패터닝하여 profiling 기법을 도입해, 스마트워터미터에서 용수사용량이 통합되어 검지될 시 용수사용량의 세부 용도별 re-profiling 기법을 도입하여 가정용수내 과소비되는 지점을 도출 후 절감을 유도하는 기술이 개발 중이다. 또한, 미래 용수 사용량 예측을 위해 다양한 시계열 자료를 분석하는 선형 종속 모형(자기회귀모형, 자기회귀이동평균모형, 자기회귀적분이동평균모형 등)과 비선형 종속 모형(Fuzzy Logic, Neural Network, Genetic Algorithm 등)을 활용한 예측기능이 구축되어 상호 비교하여 최적의 용수사용량 예측 도구를 제공되고 있다.

  • PDF

Characteristics of Non-Point Pollution from Road Surface Runoff

  • Lee, Chun-Sik;Jang, Seong-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.665-670
    • /
    • 2010
  • Pollutants from urban pavement consists various kinds of substances which are originated from dry deposition, a grind out tire, corrosive action of rain to pavement and facilities and raw materials of the road etc.. These are major pollutants of urban NPS (Non-point source) during rainfall period. However there is not enough information to control such pollutants for appropriate management of natural water quality. In this study of transportation areas, three monitoring stations were set up at trunk road, urban highway and national road in Gyeongnam province. Runoff flow rate was measured at every 15minutes by automatic flow meters installed at the end of storm sewer pipe within the road catchment area for water quality analysis. Data was collected every 15 minutes for initial two hours of rainfall. Additional samples were collected 1-4 hours interval till the end of rainfall. The monitoring parameters were $COD_{Mn}$, SS, T-N & T-P and heavy metals. The average EMCs of TSS and $COD_{Mn}$ were 62.0 mg/L and 24.2 mg/L on the city trunk road, which were higher than those of urban highway and national road, indicating higher pollutant loads due to activities in the city downtown area beside the vehicle. On the other hand, the average EMC of T-N and T-P were in the range of 2.67-3.23 mg/L and 0.19-3.21 mg/L for all the sampling sites. Heavy metals from the roads were mainly Fe, Zn, Cu and Mn, showing variable EMCs by the type of road. From the TSS wash-off analysis in terms of FF(first flush) index, first flush phenomenon was clearly observed in the trunk road(FF : 0.89-1.43). However, such mass delivery behavior was not apparently shown in urban highway(FF : 0.90-1.11) and national road(FF : 0.81-1.41).

The Development of a Input Data Automatic Generation System for the Storm Management Simulation based on UIS (UIS기반 홍수관리 시뮬레이션을 위한 입력 데이터 자동 생성 시스템 개발)

  • Kim, Ki-Uk;Lee, Jeong-Eun;Hwang, Hyun-Suk;Kim, Chang-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.2
    • /
    • pp.247-256
    • /
    • 2008
  • Recently, natural disasters like flooding damages have frequently occurred as to typhoons and local downpours affected by the climate changes. Many researches have actively been studied in analysing runoff models, the verification of their parameters, and the inflow on surfaces in order to lessen the damages. However, much time and effort needs in generating input files of the models in most current researches. Therefore, in this paper we develop a system for generating a simulation input data automatically. This system is connected to the EPA-SWMM based on the spatial data in the UIS systems and consists the simulation module for analysing urban flooding and the SWMM simulator module. Also, we construct a prototype using a range of regular inundation to generate a simulation input file. This system gives advantages showing inundation areas based on the map viewer as well as lessening errors of input data and simulation time.

  • PDF

A Study on the Feasibility of COBie to the Wastewater Treatment Plant (COBie 기반 하수처리시설 유지관리시스템 구축)

  • Choi, Jae-Ho;Um, Dong-Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.273-283
    • /
    • 2014
  • With the introduction of COBie (Construction Operation Building Exchange) in BIM technology enabling an automatic transfer of design and construction information to operation and management (O&M) phase, the BIM centric O&M management system development process has been tested on the subject of architectural types of building. However, for now, there is a need to investigate the technical feasibility of COBie application to civil structures including industrial facilities. This study takes both "O&M Guideline for Public Wastewater Treatment Plant" and a real wastewater treatment plant into account for the purpose, in which the latter is intended to supplement the result of the first. The findings are three-folds: (1) COBie, as an asset modeling, is not sufficient enough to encompass commissioning data, (2) more relevant IFC development and family library build-up useful to modeling wastewater treatment plant is imperative, and (3) well-planned coordination and organization of COBie data-set in line with O&M practice will enhance the feasibility of the COBie in industrial facilities. The result could be used for a basis study for COBie application, particularly in industrial facilities.