• 제목/요약/키워드: Automatic Meter Reading (AMR)

검색결과 57건 처리시간 0.021초

검침데이터를 이용한 전력설비 시공간 부하분석모델 (Spatio-temporal Load Analysis Model for Power Facilities using Meter Reading Data)

  • 신진호;김영일;이봉재;양일권;류근호
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1910-1915
    • /
    • 2008
  • The load analysis for the distribution system and facilities has relied on measurement equipment. Moreover, load monitoring incurs huge costs in terms of installation and maintenance. This paper presents a new model to analyze wherein facilities load under a feeder every 15 minutes using meter reading data that can be obtained from a power consumer every 15 minute or a month even without setting up any measuring equipment. After the data warehouse is constructed by interfacing the legacy system required for the load calculation, the relationship between the distribution system and the power consumer is established. Once the load pattern is forecasted by applying clustering and classification algorithm of temporal data mining techniques for the power customer who is not involved in Automatic Meter Reading(AMR), a single-line diagram per feeder is created, and power flow calculation is executed. The calculation result is analyzed using various temporal and spatial analysis methods such as Internet Geographic Information System(GIS), single-line diagram, and Online Analytical Processing (OLAP).

스마트 박스를 활용한 실시간 수요관리 (A Real-Time Demand Response Management Using Smart Box)

  • 고동관;배준철;민경천;이재규
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권1호
    • /
    • pp.57-62
    • /
    • 2016
  • 수요자원 거래시장은 한국전력거래소rk 운영하는 수요관리 프로그램으로 한전 검침정보제공 포털 시스템이 제공하는 에너지 사용 데이터를 기준으로 에너지 절감여부를 판단한다. 그러나 검침정보제공 포털 시스템이 제공하는 에너지 사용 데이터는 실시간 데이터가 아닌 지연 데이터로 에너지 절감 주체인 수용가와 관리 주체인 수요관리사업자 모두 현재의 에너지 사용량을 확인할 수 없는 단점이 있다. 이러한 단점을 보완하기 위해 수용가 수전단에 스마트박스를 설치하여 실시간 데이터를 확인하고 전력부하를 능동적으로 절감할 수 있게 하였다.

가변 콘덴서를 이용한 디지털 수도미터의 설계 및 제작 (Design and Fabrication of Digital Water Meter Using a Variable Capacitor)

  • 박근형
    • 한국전기전자재료학회논문지
    • /
    • 제29권3호
    • /
    • pp.141-146
    • /
    • 2016
  • The AMR(automatic meter reading) system has been increasingly and widely used for its efficient and intelligent management, which is a technology that automatically collects consumption data from a water meter or energy metering device. The digital meter instead of the mechanical meter should be used in the system. Up to now, various types of sensor to measure the water flow rate have been used in the digital water meter, for example, reed switch, photo IR approximate sensor, ultrasonic sensor, electromagnetic sensor, etc. In this paper, a new sensing technology, where a variable capacitor and digital circuit were used for sensing the water flow rate, was proposed. The circuit was designed and verified by Pspice simulation. And a PCB board for the circuit was fabricated. After then, a prototype of digital water meter using a variable capacitor to measure the water flow rate was fabricated. The function tests of the fabricated digital water meter were performed, and it was found that the meter worked properly. Since the new technology has much better properties in terms of cost and power consumption compared to conventional technologies, it should be one of the major digital water meter technologies in the future.

지리정보와 검침데이터를 이용한 배전계통 부하분석모델 개발 (Development of the Distribution System Load Analysis Model using Geographic Information and Meter Reading Data)

  • 신진호;이봉재;송재주;이정일;김영일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2124-2125
    • /
    • 2006
  • 실세계의 복잡하고 종합적인 정보를 빠르고 효율적으로 분석 처리할 수 있는 지리정보시스템(GIS : Geographic Information System)의 효용성이 인식되면서 전력산업에서도 전국의 시설물 관리를 위해 수치 지리정보를 구축하였다. 한편, 약 10만호의 고압고객을 대상으로 15분 단위의 전력사용량을 무선통신망을 이용하여 자동원격검침(AMR: Automatic Meter Reading)하고 있다. 본 논문에서는 산재된 대용량의 AMR 시계열성 데이터와 공간성을 지니는 배전계통 지리정보 데이터를 이용하여 회선 및 구간별 상세한 부하패턴 분석, 공간적 부하분포 및 특성 분석을 할 수 있는 새로운 활용모델을 개발하고 그 결과를 제시하고자 한다.

  • PDF

LoRaWAN IoT 원격검침장치 개발 (Development of LoRaWAN IoT Automatic Meter Reading Systems)

  • 박재삼
    • 한국전자통신학회논문지
    • /
    • 제15권5호
    • /
    • pp.913-922
    • /
    • 2020
  • 본 논문에서는 무라타 전자의 LoRa RF 모듈을 이용한 LoRa 통신모듈을 설계하여 디지털미터기에 장착하는 구성과, 다수의 미터기 데이터를 DCU(Data Concentrate Unit)에서 정합하여 LoRaWAN 으로 네트워크를 구성하는 원격검침 네트워크 구성 방법을 제시한다. 개발된 시스템은 수요자의 구성에 따라 미터기를 직접 네트워크에 연결하거나 DCU로 정합하여 네트워크에 연결하도록 선택가능하게 함으로써 기존 시스템 보다 네트워크 구성에 있어서 용이하고 경제적으로 설치가능하다. 개발된 시스템은 디지털수도미터기를 예로하여 구성하였지만 전기, 수도, 가스, 온수 및 난방 등 타계량기의 계량값을 원격검침 하는데도 적용가능하다. 주요개발 내용은 디지털미터기, LoRa 모듈, DCU 설계, 구성 및 제작과 LoRaWAN 네트워크 연결, 미터 데이터를 서버로 전송하는 방법이며, 이들 요소들을 연계하여 시스템을 구성하고 실제 LoRaWAN 통신을 테스트하고 그 결과를 보여준다.

한국형 배전자동화용 수용가 단말제어장치 개발 (A Development of CRU for KODAS)

  • 김종수;계문호;오상기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.419-421
    • /
    • 1994
  • A CRU (Customer Remote Unit) for KODAS(Korea Distribution Automatic System) is presented in the paper. This equipment works as a terminal unit for the Load Control and the AMR(Automatic Meter Reading). It is composed of control, drive, input, display, and communication parts. A CRU calculates and memorizes the active power, time-of-use, and demand by the pulse from watthour meter for AMR. It also transfers the data to Center Control System. It can measure current, voltage, and power factor by adding the simple circuit. For load control, It receives the necessary informations such as the load control periods, modes, and time intervals. It controls the load until the stopping commad comes. The system reliability has been proved using a prototype.

  • PDF

Binary CDMA 기술을 이용한 무선 원격검침 네트워크 구현방안에 대한 연구 (A Study on the Implementation of Wireless AMR Network using Binary CDMA)

  • 권대길;조진웅
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2010년도 추계학술발표논문집 1부
    • /
    • pp.406-409
    • /
    • 2010
  • 본 논문은 국내원천 기술인 Binary CDMA 기술을 소개하고 AMR(Automatic Meter Reading) 시스템에 Binary CDMA 무선 기술을 어떻게 적용할지를 연구하고자 한다. 주요 연구내용은 Binary CDMA 원격검침 시스템, 무선 원격검침을 구현하기 위한 피코넷 네트워크 구성, 데이터 송수신을 위한 전송 스케줄링을 다루고자 한다. 그리고 원격검침의 데이터는 공공의 성격을 뛰는 아주 중요한 데이터이기 때문에 무선 패킷의 암호화 적용방안에 대해서도 연구하고 하고자 한다.

  • PDF

스마트워터그리드를 위한 LoRa IoT 원격검침 및 계량데이터 시스템 개발 (Development of LoRa IoT Automatic Meter Reading and Meter Data Management System for Smart Water Grid)

  • 박정원;박재삼
    • 한국항행학회논문지
    • /
    • 제26권3호
    • /
    • pp.172-178
    • /
    • 2022
  • 본 논문은 스마트워터그리드의 핵심기술 중 하나인 수도미터 원격검침(AMR)을 LoRa IoT 네트워크를 이용하여 구현하는 방법에 대한 연구이다. 연구의 주된 내용은 한 대의 PC 서버에서 LoRa 통신으로 다수 세대의 수도미터기 검침 값을 수신받아 데이터베이스에 저장하는 한편 인터넷을 통하여 웹 서버의 클라우드 저장을 하여 사용자의 스마트폰으로 검침 데이터를 열람할 수 있는 네트워크를 구성하는 시스템을 개발하고 테스트 결과를 보인다. 시스템 구성을 위하여 디지털 수도미터기 메인보드의 하드웨어와 펌웨어를 자체적으로 설계 제작하고, PC 서버프로그램으로서 계량데이터운용시스템(MDMS) 프로그램을 비주얼 C#으로, 사용자 스마트폰에서 구동되는 앱 프로그램은 안드로이드 스튜디오로 자체 설계 제작한다. 제작된 각각의 구성을 연결하여 전체 시스템을 실험실 내의 유량 테스트벤치에 장착하여 테스트하여 결과를 보이고, 실제 사용환경 테스트를 위하여 대학 주변의 5곳을 선정하여 전송 거리 테스트를 하여 개발된 시스템이 실사용 현장에 사용 가능함을 보인다. 본 연구결과는 워터그리드에서 충분히 활용할 수 있어 물 사용량 소비패턴, 위치 정보 등을 분석하여 효과적인 물 사용량 관리뿐만 아니라 독거, 치매 어르신 등이 정상적인 생활을 하는지를 추정까지 가능하다는 등 다양한 사회안전망으로도 확대 가능하다.

원격검침을 위한 다기능 자바카드 설계 및 구현 (Design and Implementation of Multi-functional Java Card for AMR)

  • 강환수;조진형;권귀석;이종만;강환일
    • 한국콘텐츠학회논문지
    • /
    • 제9권8호
    • /
    • pp.64-72
    • /
    • 2009
  • 원격지에 있는 전기, 가스, 수도 등의 검침기에서 유선 또는 무선으로 검침을 자동화하는 원격검침(AMR)에는 전력선통신 방식, 근거리무선통신 방식 등이 주로 연구되어 왔다. 본 논문에서는 유비쿼터스시대의 필수 품목이 펠 자바카드를 활용하여 원격검침을 수행할 수 있는 원격검침자바카드(JCA: Java Card for AMR)를 설계 구현하였다. 본 논문의 원격검침자바카드(JCA)는 전력공급사에서 제공하는 표준 거래 절차를 준수하고 전력사용로그 및 정산 자료를 관리하며 다기능 신용카드(EMV) 기능이 충족되도록 설계되었다. 원격검침자바카드(JCA)는 오픈 플랫폼(open platform)의 다기능 스마트카드로 응용 애플릿의 후발급이 가능하므로 신용카드나 교통카드 기능과 함께 다른 제휴사의 응용을 탑재할 수 있다. 원격검침자바카드(JCA)는 다른 원격검침방식과 비교하여 원격검침 시스템 구축비용이 적을 뿐만 아니라 자바차드의 인증과 보안을 활용하여 선불 및 후불 정산 방식이 가능하고 제휴 사와의 연계 서비스로 다양한 부가서비스를 제공할 수 있다.

전자식 전력량계와 무선모듈을 이용한 전력품질 표시 및 모니터링 (Power Quality Monitoring with Electronic Watt-hour meter and Wireless communication module)

  • 정득일;손영대
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.172-174
    • /
    • 2007
  • An electronic watt-hour meter with high-precision measurement technology can provide many valuable metering data of a real-time system measurements, such as per-phase voltage, ampere, active power, reactive power, apparent power, power factor, and system frequency. Also many of accumulated metering data such as active energy, reactive energy, apparent energy, and load profile can be gettable from an electronic watt-hour meter[1]. This paper presents an approach of the small-sized AMR (Automatic Meter Reading) that provides customers with a very valuable electrical service. This AMR service transmits lots of a valuable metering data by using ZigBee communication module, so that users resided in their premises can use the information to audit a power quality and improve their electrical conditions by using the PQ monitoring device equipped with ZigBee receiver. This PQ monitoring device shows metering data on LCD and transmits to the PC through an internal network. Also, the device can keep the valuable meter data into a built-in non-volatile memory. The final goal of this paper is to better understand the power quality of electrical systems and offer the power qualify information for the convenience of all power consumers.

  • PDF