• 제목/요약/키워드: Authors determined

검색결과 320건 처리시간 0.027초

Evaluation of Drainage by Near Infrared Spectroscopy

  • Takamura, Hitoshi;Miyamoto, Hiroko;Mori, Yoshikuni;Matoba, Teruyoshi
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1271-1271
    • /
    • 2001
  • Water pollutants in drainage mainly consist of organic compounds. Hence, total organic carbon (TOC), chemical oxygen demand (COD), and biochemical oxygen demand (BOD) were generally used as the indices of pollution. However, these values are determined by special analyzer (TOC), titration method (COD), or microbe culture (BOD). Therefore, the development of simple and easy methods for the determination of water pollution is required. The authors reported the evaluation of water pollution by near infrared (NIR) spectroscopy in a model system with food components (Takamura et al. (200) Near Infrared Spectroscopy: Proceedings of 9th International Conference, pp. 503-507). In this study, the relationship between NIR spectra and drainage was investigated in order to develop a method for evaluation of drainage by NIR. Drainage was obtained in Nara Purification Center. The ranges of TOC, COD, and BOD were 0-130, 0-100 and 0-200, respectively. NIR transmittance spectra were recorded on NIR Systems Model 6250 Research Composition Analyzer in the wavelength range of 680-1235 and 1100-2500 nm with a quartz cell (light path: 0.5, 1, 2, 4 and 10mm) at 10-40. Statistical analysis was performed using NSAS program. A partial least squares (PLS) regression analysis was used for calibration. As the result, a good correlation between the raw NIR spectra and OC was obtained in the calibration. The best light path was 10 and 0.5mm in the wavelength range of 680-1235 and 110-2500nm, respectively. In the calibration, correlation coefficients(R) were 096-0.97 in the both range. In the prediction, however, a good correlation (R=0.89-0.96) was obtained only in the range of 6801235 nm, Similar results were obtained in the cases of COD and BOD. These results suggest the possibility that NIR spectroscopy can be used to evaluate drainage.

  • PDF

Influence of Clinical and Anatomic Features on Treatment Decisions for Anterior Communicating Artery Aneurysms

  • Choi, Jae-Hyung;Kang, Myung-Jin;Huh, Jae-Taeck
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권2호
    • /
    • pp.81-88
    • /
    • 2011
  • Objective : The purpose of this study was to analyze the clinical and anatomic features involved in determining treatment modalities for anterior communicating artery (AcoA) aneurysms. Methods : The authors retrospectively evaluated 112 AcoA aneurysms with pretreatment clinical features including age, Hunt and Hess grade, medical or neurological comorbidity, and anatomical features including aneurysm size, neck size, dome-to-neck ratio, vessel incorporation, multiple lobulation, and morphologic scoring system. Post-treatment clinical results were classified according to the Glasgow Outcome Scale, and anatomic results in coiled patients were classified according to the modified Raymond scale. Using multivariate logistic regression, the probabilities for decision making between surgical clipping and coil embolization were calculated. Results : Sixty-seven patients (60%) were treated with surgical clipping and 45 patients (40%) with endovascular coil embolization. The clinical factor significantly associated with treatment decision was age (${\geq}$65 vs. <65 years) and anatomical factors including aneurysm size (small or large vs. medium), dome-to-neck ratio (<2 vs. ${\geq}$2), presence of vessel incorporation, multiple lobulation, and morphologic score (${\geq}$2 vs. <2). In multivariate analysis, older patients (age, 65 years) had significantly higher odds of being treated with coil embolization relative to clipping (adjusted OR=3.78; 95% CI, 1.39-10.3; p=0.0093) and higher morphological score patients (${\geq}$2) had a higher tendency toward surgical clipping than endovascular coil embolization (OR=0.23; 95% CI, 0.16-0.93; p=0.0039). Conclusion : The optimal decision for treating AcoA aneurysms cannot be determined by any single clinical or anatomic characteristics. All clinical and morphological features need to be considered, and a collaborative neurovascular team approach to AcoA aneurysms is essential.

Intracavitary Radiation Therapy for Recurrent Cystic Brain Tumors with Holmium-166-Chico : A Pilot Study

  • Ha, Eun Jin;Gwak, Ho-Shin;Rhee, Chang Hun;Youn, Sang Min;Choi, Chang-Woon;Cheon, Gi Jeong
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권3호
    • /
    • pp.175-182
    • /
    • 2013
  • Objective : Intracavitary injection of beta-emitting radiation source for control of cystic tumors has been tried with a benefit of localized internal radiation. The authors treated cystic brain tumor patients with Holmium-166-chitosan complex (Ho-166-chico), composed of a beta-emitting radionuclide Holmium-166 and biodegradable chit polymer, and evaluated the safety and effective measurement for response. Methods : Twenty-two patients with recurrent cystic brain tumor and/or located in a deep or eloquent area were enrolled in this pilot study. The cyst volume and wall thickness were determined on CT or MRI to assess radiological response. The activity of Ho-166-chico injected via Ommaya reservoir was prescribed to be 10-25 Gy to the cyst wall in a depth of 4 mm. Results : There was neither complications related to systemic absorption nor leakage of Ho-166-chico in all 22 patients. But, two cases of oculomotor paresis were observed in patients with recurrent craniopharyngioma. Radiological response was seen in 14 of 20 available follow-up images (70%). Seven patients of 'evident' radiological response experienced more than 25% decrease of both cyst volume and wall thickness. Another 7 patients with 'suggestive' response showed decrease of cyst volume without definitive change of the wall thickness or vice versa. All patients with benign tumors or low grade gliomas experienced symptomatic improvement. Conclusion : Ho-166-chico intracavitary radiation therapy for cystic tumor is a safe method of palliation without serious complications. The determination of both minimal effective dosage and time interval of repeated injection through phase 1 trial could improve the results in the future.

위해정보를 활용한 한국형 제품 위험성 평가 모델 개발에 관한 연구 (Developing a Product Risk Assessment Model for Korea Using Injury Data)

  • 배진한;송해근;박영택
    • 품질경영학회지
    • /
    • 제41권4호
    • /
    • pp.623-635
    • /
    • 2013
  • Purpose: The recent major recalls of hazardous products caused consumer product safety acts to be strengthen worldwide. Although the recall system of hazardous products in Korea has been operating based on Framework Act on Product Safety since 2011, the evaluation of product risk has been relied on not the results of objective incident data but the results of illegal product investigations. The purpose of this paper is to propose a product risk assessment model for Korea using injury data. Methods: The authors derived Korea's risk assessment method by analysing the advantages and disadvantages of the most widely used models in advanced countries such as EU's RAPEX RAG and Janpan's R-MAP. In this study, the level of relative frequency and severity of injury are determined based on the objective incident data and the length of hospitalization respectively. In addition, the injury data occurred during 2011 is applied to the proposed risk assessment model for case study. Results: The data analysed in this paper can be classified as high risk, medium risk, low risk, acceptable risk, and safe products through the matrix f rom the combination of the relative frequency and the severity derived. Conclusion: The proposed risk assessment model in this study has advantage obtaining reliable objective results because it uses actual injury data and redeems the drawbacks of the existing models used in advanced countries. Furthermore, because the proposed model shows the high risk products among many, it is expected to be useful especially for customs whose main job is inspecting the imported goods and the government when selecting the target product groups for safety investigation.

선택적 세로토닌 재흡수차단제들이 만성 경도 스트레스 후의 백서에서 수동적 회피학습에 미치는 영향 (Effects of Selective Serotonin Reuptake Inhibitors on the Retention of Passive Avoidance Learning after Chronic Mild Stress in Rats)

  • 이기철;장환일
    • 생물정신의학
    • /
    • 제4권2호
    • /
    • pp.237-245
    • /
    • 1997
  • The study was designed to evaluate the significant roles of SSRI in rat of depression model. Chronic exposure to mild unpredictable stress has been found to depress the consumption of sweet 1% sucrose solutions in the Sprague-Dawley rats. We applied the variety of 11 types of stress regimens and identified depressive behaviours(developed by Willner) in 70 Sprague-Dawley rats. Rats in experiments were stratified into 6 groups, ie ; 3 kinds of SSRI(paroxetine, fluoxetine, sertraline), clomipramine, choline and saline control. Memory function was evaluated by passive avoidance learning and retention test. The authors determined how long memory retention would remain improved with 24 hour, 1 week, 2 weeks, 3 weeks, and 4 weeks at training-testing interval in depressive states of the Sprague-Dawley rats. The results were as follows ; 1) There were no significant differences between the 6 groups at the 24 hour training-testing interval. 2) The paroxetine treated group showed significant differences from the control group at the 1 week and 2 weeks training-testing interval. 3) The paroxetine and the fluoxetine treated groups showed singificant differences from the control group at 3 week training-testing interval. 4) The paroxetine and the choline treated groups showed significant differences from the control group at 4 week training-testing interval. In summary, paroxetine had an effect on long term memory processing from 1st week to 4th week. Also, fluoxetine(at 3rd week) and choline(at 4th week) had effect on long term memory processing. Sertraline, clomipramine were ineffective on memory processing during 4 weeks observation. Possible explanations why paroxetine had early effect on memory processing than the other selective serotonin reuptake inhibitors are rapid bioavailability, which is the characteristics of pharmacokinetics of paroxetine. In clinical situation, author carefully suggest that SSRI would be beneficial to improve the memory function caused by depressive neurochemical changes.

  • PDF

Differential Gene Expression in Estradiol-3-Benzoate-Treated Liver and Chemically- Induced Hepatocellular Carcinoma

  • KIM , SEYL;KANG, JIN-SEOK;JANG, DONG-DEUK;LEE, KOOK-KYUNG;KIM, SOON-AE;HAN, BEOM-SEOK;PARK, YOUNG-IN
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권6호
    • /
    • pp.1286-1294
    • /
    • 2004
  • In a previous study by the current authors, hepatocellular carcinoma (HCC) was determined to be epidemiologically sex-dependent, and the incidence and multiplicity of HCC found to decrease in estradiol-3 benzoate (EB)-treated F344 rats. Therefore, to ascertain the anticancer mechanism of EB, a commercially available cDNA microarray, with a total of 14,815 cDNA rat gene clones, was used to determine the differentially expressed genes in nontreated livers, EB-treated livers, and diethynitrosolamine (DEN)-induced HCC. In the sequenced experiment, a total of 85 genes were differentially expressed at either two or more times the rate of the normal expression, where 33 genes were downregulated by EB, and 52 genes upregulated. Candidate genes were selected according to significant changes observed in the mRNA expression in the EB-treated livers compared with the nontreated livers, then these genes were filtered according to their different expression patterns in the DEN-induced tumors compared to the estrogen-treated livers. To confirm the microarray data, a real-time PCR analysis was performed for ten selected genes: the H-ras revertant protein 107 (H­rev107), insulin-like growth factor binding protein (lOFBP), parathyroid hormone receptor (PI'HR), SH3 domain binding protein (SH3BP), metallothionein, src-suppressed C-kinase substrate (SSeCK) gene, phosphodiesterase I, CD44, epithelial membrane protein 3 (EMP3), and estrogen receptor a (ERa). The SSeCK and phosphodiesterase I genes were both upregulated in the DEN-induced hepatocarcinomas, yet their possible carcinogenic functions remain unknown. Meanwhile, the other genes were downregulated, including the genes related to growth regulation (IOFBP, H-revI07, ER$\alpha$), adipogenesis inhibition (PTHR), and tumor suppression (metallothionein).

쥐를 이용한 포르말린 및 열 유발 통증에서 척수강 Sildenafil의 효과에 관한 연구 (Evaluation for the Effects of Intrathecal Sildenafil on the Formalin- and Thermal-induced Nocieption of Rats)

  • 윤명하;배홍범;신동진;김창모;정성태;김석재;최정일
    • The Korean Journal of Pain
    • /
    • 제19권1호
    • /
    • pp.17-21
    • /
    • 2006
  • Background: Cyclic guanosine monophosphate (cGMP) plays an important role in the modulation of nociception. Although local sildenafil produces antinociception, by increasing cGMP through the inhibition of phosphodiesterase 5, the effect of spinal sildenafil has not been determined. The authors evaluated the effects of intrathecal sildenafil on the nociceptive behavior evoked by formalin injection and thermal stimulation. Methods: Lumbar intrathecal catheters were implanted into rats, with formalin and Hot-Box tests used as nociceptive models. The formalin-induced nociceptive behavior (flinching response) and withdrawal latency to radiant heat were measured, and the general behaviors also observed. Results: The intrathecal administration of sildenafil produced dose-dependent suppression of the flinches in both phases in the formalin test, and increased the withdrawal latency in the Hot-Box test. No abnormal behaviors were noted. Conclusions: Sildenafil, an inhibitor of phosphodiesterase 5, is active against the nociceptive state evoked in the spinal cord by formalin and thermal stimulations. Accordingly, spinal sildenafil may be useful in the management of pain.

한국 근해에 있어서의 중층트로올의 연구 - IV (Study on the Midwater Trawl Available in the Korean Waters - IV)

  • 이병기
    • 수산해양기술연구
    • /
    • 제23권1호
    • /
    • pp.6-10
    • /
    • 1987
  • 한국 근해에서 조업하는 트로올선에 알맞은 중층 트로올어구를 개발하기 위하여 부산수산대학 실습선 부산 404호(160 GT, 750Ps)로서 조업하기에 알맞게 설계된 어구로서 어구의 유체저항을 측정하고, 그것으로부터 어구의 유체저항을 추산할 수 있는 식을 유도하고, 또한 전개판의 전개력계수와 항력계수를 구한 것을 요약하면 대략 다음과 같다. 1. 어구의 전항력 T=2.15 v 상(1.12), 그물의 항력 R 하(N)=1.96 v 상(1.01)으로서 v의 지수는 1에 가까워서 그물이 물을 잘 여과시켜줌을 시사한다. 2. 소산의 저항의 식에 따라 구한 그물의 유체저항의 추산식은 R 하(N)=4.3$\times$d/l$\times$abv 라고 표현할 수 있다. 3. 전개판의 전개력은 그물의 항력의 19~22%이고, 전개력계수는 1.5정도이며, 항력은 그물의 항력의 5~7%이고, 항력계수는 0.42정도이다

  • PDF

초고주파 가열치료를 위한 MR 호환 동축 슬롯 안테나의 개발 (Development of MR Compatible Coaxial-slot Antenna for Microwave Hyperthermia)

  • 김태형;천송이;한용희;김동혁;문치웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권4호
    • /
    • pp.333-340
    • /
    • 2009
  • MR compatible coaxial-slot antenna for microwave hyperthermia was developed while its structure and size of each part were determined by computer simulation using finite element method(FEM). Its local heating performance was evaluated using tissue-mimic phantom and swine muscles. 2% agarose gel mixed with 6mM/$\ell$ $MnCl_2$ as a biological tissue-mimic phantom was heated by the proposed antenna driven by a 2.45GHz microwave generator. The temperature changes of the phantom were monitored using multi-channel digital thermometer at the distance of 0mm, 5mm, 10mm and 20mm from the tip center of the antenna. Also muscle tissue of swine was heated for 2 and 5minutes with 50W and 30W of microwave generator powers, respectively, to evaluate the local heating performance of the antenna. MRI compatibility was also verified by acquiring MR images and MR temperature map. MR signals were acquired from the agarose gel phantom using $T2^*$ GRE sequence with 1.5T clinical MRI scanner(Signa Echospeed, GE, Milwaukee, WI, U.S.A.) at Pusan Paik Hospital and were transferred to PC in order to reconstruct MR images and temperature map using proton resonance frequency(PRF) method and laboratory-developed phase unwrapping algorithm. Authors found that it has no severe distortion due to the antenna inserted into the phantom. Finally, we can conclude that the suggested coaxial-slot antenna has an excellent local heating performance for both of tissue-mimic phantom and swine muscle, and it is compatible to 1.5T MRI scanner.

Development of a Stereotactic Device for Gamma Knife Irradiation of Small Animals

  • Chung, Hyun-Tai;Chung, Young-Seob;Kim, Dong-Gyu;Paek, Sun-Ha;Cho, Keun-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권1호
    • /
    • pp.26-30
    • /
    • 2008
  • Objective : The authors developed a stereotactic device for irradiation of small animals with Leksell Gamma Knife Model C. Development and verification procedures were described in this article. Methods : The device was designed to satisfy three requirements. The mechanical accuracy in positioning was to be managed within 0.5 mm. The strength of the device and structure were to be compromised to provide enough strength to hold a small animal during irradiation and to interfere the gamma ray beam as little as possible. The device was to be used in combination with the Leksell G-$frame^{(R)}$ and $KOPF^{(R)}$ rat adaptor. The irradiation point was determined by separate imaging sequences such as plain X-ray images. Results : The absolute dose rate with the device in a Leksell Gamma Knife was 3.7% less than the value calculated from Leksell Gamma $Plan^{(R)}$. The dose distributions measured with $GAFCHROMIC^{(R)}$ MD-55 film corresponded to those of Leksell Gamma $Plan^{(R)}$ within acceptable range. The device was used in a series of rat experiments with a 4 mm helmet of Leksell Gamma Knife. Conclusion : A stereotactic device for irradiation of small animals with Leksell Gamma Knife Model C has been developed so that it fulfilled above requirements. Absorbed dose and dose distribution at the center of a Gamma Knife helmet are in acceptable ranges. The device provides enough accuracy for stereotactic irradiation with acceptable practicality.