• Title/Summary/Keyword: Auger-drilled pile

Search Result 14, Processing Time 0.029 seconds

A Study on the Improvement of Bearing Capacity Prediction Equation for Auger-drilled Piling (매입말뚝공법의 지지력 예측식 개선에 관한 연구)

  • 최도웅;한병권;서영화;조성한
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.382-389
    • /
    • 2002
  • Recently, auger-drilled piling has been widely used in urban area to reduce the air pollution and noise. But this construction method that its basic theory was introduced from Japan may be changed depending on the each piling company and construction field condition. Therefore, the design code and management method for auger-drilled piling is not defined yet. Especially, the lack of research on the bearing capacity of auger-drilled piling leads to the absence of rational bearing capacity prediction equation. This paper presents the optimum design code and economical construction method of the auger-drilled piling by proposing the new bearing capacity prediction equation based on the site specific soil types and construction conditions. In this paper, existing bearing capacity prediction equations and current pile load tests were compared. And the end bearing capacity and skin friction characteristics were also analyzed by comparing the results of CAPWAP. From the results of analysis, a reliable bearing capacity prediction equation considered soil types is proposed.

  • PDF

Bearing Capacity of In-situ Pile Installed using Pulse Power (펄스파워를 이용한 현장타설말뚝의 지지력 특성)

  • Kim, Tae-Hoon;Chai, Soo-Geun;Jeong, Gyu-Geom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.521-527
    • /
    • 2005
  • In the past decades, complain about ground vibration and noise induced by pile driving has been quickly increased. Because of that, auger drilled piling methods have frequently used specially in urban area. However, the present auger drilled piling methods induce inevitable ground disturbance as well as a certain degree of vibration and noise due to the final hammering. For these reasons, a new auger drilled piling method is required to be developed. This paper introduces PDT(Pulse Discharge Technology) piling method and presents the characteristics of bearing capacity. The PDT piling method is to install in-situ piles using electric power so called Pulse. The pile installed by PDT appears to be able to develop shaft and end bearing capacity efficiently.

  • PDF

Design criteria and Case History of Korean Railway for Auger-drilled Pilling (철도분야 매입말뚝 설계기준 및 적용 현황)

  • Lee, Su-Hyung;Choi, Jeong-Hwan;Hwang, Seon-Keun;Eum, Ki-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.541-548
    • /
    • 2008
  • Active application of auger-drilled piling is expected in Korea considering its advantage in noise and vibration problems against driven piling and its cost-effectiveness in comparison to the cast in-situ piling. The current design practice being used in Korea is adopted from the Japanese one, however the equipment and construction procedure is modified for the geotechnical conditions and construction circumstances in Korea. Therefore there is an urgent need for the establishment of the rational design criteria for the auger-drilled piling in Korea. As the preliminary work for the establishment, this paper presents the current practice in Korean railway constructions. Design criteria of Korea Railway Network Authority are introduced and its characteristics and the problems are described. Application cases of auger-drilled pile to railway construction are introduced as well.

  • PDF

Characteristics of the Bearing Capacity for New Auger-Drilled Piles (새로운 매입말뚝 공법의 지지력 특성)

  • 백규호
    • Geotechnical Engineering
    • /
    • v.13 no.4
    • /
    • pp.25-36
    • /
    • 1997
  • To increase the bearing capacity of existing auger-drilled piles and decrease the noise and vibration during the installation of the piles, Spirally-reamed and Under-reamed auger trilled piling methods were developed. Field tests were performed to verify the inurement degree of bearing capacity and the constructional possibility of the new augerdrilled piling methods. The test results showed that the bearing capacity of the new augertrilled piles was fairly improved by the grooves of piles, and the skin friction was affected by the groove height and spacing between grooves. It was found that the skin friction takes the great part of total bearing capacity in auger drilled Biles, i.e. 74~80% in case of the existing methods and 81~86% in case of these methods. Moreover, the settlement of spirally-reamed and under reamed piles was smaller than that of the existing augerdrilled pile for the same loading state.

  • PDF

A Study of Applicability of PDT(Pulse Discharge Technology) Pile to Kyung-Geon Rail Road and the bedding Construction of a new port in Busan (경전선 복선전철 및 부산신항 노반건설공사 중 PDT말뚝 적용성 연구)

  • Hur, Eok-Jun;Park, Jae-Myung;Yun, Su-Dong;Kim, Tae-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1203-1208
    • /
    • 2007
  • In the past decades, complain about ground vibration and noise induced by pile driving has been quickly increased. Because of that, auger drilled piling methods have frequently used specially in urban area. However, the present auger drilled piling methods induce inevitable ground disturbance as well as a certain degree of vibration and noise due to the final hammering. For these reasons, a new auger drilled piling method is required to be developed. This paper introduces PDT(Pulse Discharge Technology) piling method and presents the characteristics of bearing capacity. The PDT piling method is to install in-situ piles using electric power so called Pulse. The pile installed by PDT appears to be able to develop shaft and end bearing capacity efficiently. This paper introduces PDT(Pulse Discharge Technology) piling method, which is the 512nd new construction technology. The PDT piling method is to install in-situ piles using electrical power so called Pulse power. The pulse power is physical value that indicates the energy change per unit time(dE/dt). Since the pulse power is to push ground, using the pulse power is enable a hole to be expanded as well as the ground to be improved by compaction. Therefore, The pile installed by PDT appears to be able to develop shaft and end bearing capacity efficiently. In this study, couples of pile loading tests were carried out to figure out whether or not the PDT piling method is applicable to constructions like rail road facility. As a result, it was concluded that the PDT piling technique meet the requirements for such a rail road related construction.

  • PDF

Evaluation of Bearing Capacity on PHC Auger-Drilled Piles Using Artificial Neural Network (인공신경망을 이용한 PHC 매입말뚝의 지지력 평가)

  • Lee, Song;Jang, Joo-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.6
    • /
    • pp.213-223
    • /
    • 2006
  • In this study, artificial neural network is applied to the evaluation of bearing capacity of the PHC auger-drilled piles at sites of domestic decomposed granite soils. For the verification of applicability of error back propagation neural network, a total of 168 data of in-situ test results for PHC auger-drilled plies are used. The results show that the estimation of error back propagation neural network provide a good matching with pile test results by training and these results show the confidence of utilizing the neural networks for evaluation of the bearing capacity of piles.

A Study on the skin friction characteristics of SIP and the estimation of the nonlinear numerical modelling equation (SIP말뚝의 주면마찰특성 및 비선형 수치모델식 산정에 관한 연구)

  • 천병식;임해식;김도형
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.153-160
    • /
    • 2003
  • While the interests on the environmental problem during the construction are increasing, the use of low noise-vibration auger-drilled pilling is increasing to solve noise and vibration problem in pilling. Therefore, in Korea, SIP(Soil-Cement Injected Precast Pile) method is mainly used as auger-drilled pilling. However, there is no proper design criteria compatible with the ground condition of Korea, so which is most wanted. To improve and supplement this situation, direct shear tests between SIP pile skin interface and soil were executed on various conditions. Through the analysis of test results, skin resistance characteristics of SIP were investigated thoroughly. Also, the nonlinear unit skin resistance capacity model with SM, SC soil were suggested.

  • PDF

KEC Construction and Design of Auger-drilled Piles (한국도로공사의 매입말뚝 공법의 설계와 시공)

  • Park, Young-Ho;Nam, Moon-S.;Kim, Nak-Young;Yook, Jeong-Hoon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.521-532
    • /
    • 2008
  • The SIP method developed by low noise-vibration from Japan is appropriate to the construction at urban area. However, this method has been misused as a pre-driiled driven pile method in Korea. Hence, Korea Expressway Corporation proposed 'Design & Construction Guideline for the SIP Method' following the original concept of the SIP method at 2004 and 2006. Also construction guideline of another auger-drilled piles were introduced.

  • PDF

Investigation of Characteristics and Suggestion of Evaluation Formulae for Skin Resistance of SIP (SIP 말뚝의 주면저항력 특성 고찰 및 산정식 제안)

  • Lim, Hae-Sig;Park, Yong-Boo;Park, Jong-Bae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.2
    • /
    • pp.15-21
    • /
    • 2002
  • Because of the environmental problem during the pile driving, the use of low noise-vibration auger-drilled pilling is increasing to solve noise and vibration problem in pilling. In Korea, SIP (Soil-Cement Injected Precast Pile) method is mainly used as auger-drilled pilling. But, a proper bearing capacity evaluation formula has not been suggested, yet. To improve and supplement this situation, direct shear tests between SIP pile skin interface and soil were executed under various conditions. Through the analysis of test results, skin resistance characteristics of SIP were investigated thoroughly. Also, the maximum unit skin resistance capacity evaluation formulae on SM, SC soil was suggested.

  • PDF

Suggestion of Evaluation Formula for Skin Resistance of SIP (SIP말뚝의 주면저항력 예측 모델 제안)

  • Chung, Hyung-Sik;Lim, Hae-Sig;Kim, Jung-Soo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.1
    • /
    • pp.59-66
    • /
    • 2003
  • The environmental problem due to the pile driving, the use of low noise-vibration auger-drilled pilling is increasing to solve noise and vibration problem in pilling. Therefore, in Korea, SIP (Soil-Cement Injected Precast Pile) method is mainly used as auger-drilled pilling. However, a proper bearing capacity evaluation formula has not been suggested, yet. In order to improve and supplement this situation, direct shear tests between SIP pile skin interface and soil were executed under various conditions. Through the analysis of test results, skin resistance characteristics of SIP were investigated thoroughly. Also, the nonlinear unit skin resistance capacity model and relative parameters evaluation formula with SM, SC soil were suggested.

  • PDF