• Title/Summary/Keyword: Auger Heating

Search Result 15, Processing Time 0.027 seconds

Nonequilibrium Heat Transfer Characteristics During Ultrafast Pulse Laser Heating of a Silicon Microstructure

  • Lee Seong Hyuk
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.1378-1389
    • /
    • 2005
  • This work provides the fundamental knowledge of energy transport characteristics during very short-pulse laser heating of semiconductors from a microscopic viewpoint. Based on the self-consistent hydrodynamic equations, in-situ interactions between carriers, optical phonons, and acoustic phonons are simulated to figure out energy transport mechanism during ultrafast pulse laser heating of a silicon substrate through the detailed information on the time and spatial evolutions of each temperature for carriers, longitudinal optical (LO) phonons, acoustic phonons. It is found that nonequilibrium between LO phonons and acoustic phonons should be considered for ultrafast pulse laser heating problem, two-peak structures become apparently present for the subpicosecond pulses because of the Auger heating. A substantial increase in carrier temperature is observed for lasers with a few picosecond pulse duration, whereas the temperature rise of acoustic and phonon temperatures is relatively small with decreasing laser pulse widths. A slight lagging behavior is observed due to the differences in relaxation times and heat capacities between two different phonons. Moreover, the laser fluence has a significant effect on the decaying rate of the Auger recombination.

Numerical Analysis on Heat Transfer Characteristics in Silicon Boated by Picosecond-to-Femtosecond Ultra-Short Pulse Laser (펨토초급 극초단 펄스레이저에 의해 가열된 실리콘 내의 열전달 특성에 관한 수치해석)

  • 이성혁;이준식;박승호;최영기
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.10
    • /
    • pp.1427-1435
    • /
    • 2002
  • The main aim of the present article is numerically to investigate the micro-scale heat transfer phenomena in a silicon microstructure irradiated by picosecond-to-femtosecond ultra-short laser pulses. Carrier-lattice non-equilibrium phenomena are simulated with a self-consistent numerical model based on Boltzmann transport theory to obtain the spatial and temporal evolutions of the lattice temperature, the carrier number density and its temperature. Especially, an equilibration time, after which carrier and lattice are in equilibrium, is newly introduced to quantify the time duration of non-equilibrium state. Significant increase in carrier temperature is observed for a few picosecond pulse laser, while the lattice temperature rise is relatively small with decreasing laser pulse width. It is also found that the laser fluence significantly affects the N 3 decaying rate of Auger recombination, the carrier temperature exhibits two peaks as a function of time due to Auger heating as well as direct laser heating of the carriers, and finally both laser fluence and pulse width play an important role in controlling the duration time of non-equilibrium between carrier and lattice.

Characteristics of Bio-oil by Pyrolysis with Pig Feces (돈분을 이용한 열분해공정 바이오오일의 특성)

  • Kun, Zhu;Choi, Hong L.
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.4
    • /
    • pp.57-63
    • /
    • 2008
  • The characteristics of the bio-oil produced by the pyrolysis process with pig feces was investigated in this paper. The continuous auger-type reactor produced bio-oil was maintained at the temperature range of 400 to $600^{\circ}C$, which was higher than a typical that in a conventional pyrolysis system. The pig feces was used as the feedstock. The bio-oil and its compositions were characterized by water analysis, heating values, elemental analysis, bio-oil compounds, by Gas Chromatography/Mass Spectrometry (GC/MS), and functional group by $^1H$ NMR spectroscopy. It was found that the maximum bio-oil yields of 21% w.t. was achieved at $550^{\circ}C$. This result suggested that this auger reactor might be a potential technology for livestock waste treatment to produce bio-oil because it is able to be improved to reach higher efficiency of bio-oil production in further study. The pyrolysis system reported herein had low heat transfer into the feedstock in the auger reactor so that it needs improve the heat conduction rate of the system in further study.

  • PDF

Characteristics of Pyrolysis Oils from Saccharina japonica in an Auger Reactor (Auger 반응기에서 제조한 다시마 유래 열분해오일의 특성)

  • Choi, Jae-Wook;Son, Deokwon;Suh, Dong Jin;Kim, Hwayong;Lee, Youn-Woo
    • Clean Technology
    • /
    • v.24 no.1
    • /
    • pp.70-76
    • /
    • 2018
  • Pyrolysis of Saccharina japonica in an Auger reactor was conducted by varying the temperature and the auger speed and then physicochemical properties of the S. japonica-derived pyrolysis oil were analyzed. The maximum yield of S. japonica-derived pyrolysis oil (32 wt%) was obtained at a pyrolysis temperature of $412^{\circ}C$ and an auger speed of 20 rpm. Due to low carbon content and high oxygen content in the pyrolysis oil, the higher heating value of S. japonica-derived pyrolysis oil was $23.6MJ\;kg^{-1}$, which was about 60% that of conventional hydrocarbon fuels. By GC/MS analysis, 1,4-Anhydro-d-galactitol, dianhydromannitol, 1-hydroxy 2-propanone and isosorbide were identified as the main chemical compounds of S. japonica-derived pyrolysis oil. The bio-char has low higher heating value ($13.0MJ\;kg^{-1}$) due to low carbon content and high oxygen content and contains a large amount of inorganic components and sulfur.

Performance Test and Flue Gas Characteristics of a 350 kW Wood Pellet Boiler (350 kW(300,000 kcal/h)급 우드 펠렛 보일러 운전 특성 및 성능 평가)

  • Kim, Jong-Jin;Kang, Sae-Byul
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.167-171
    • /
    • 2009
  • We conducted performance test of a 350 kW class wood pellet boiler installed at a dormitory whose total area is $1,354\;m^2$. The maximum heating capacity of the boiler is 350 kW(300,000 kcal/kg). The wood pellet boiler consists of 3 parts; boiler, hot water storage tank and wood pellet storage tank. In testing the boiler, we shut off hot water utility supply and open up floor heating water system in order to measure exact value of the heating output of the wood pellet boiler. To determine the efficiency and heating output of the wood pellet boiler, we measured mass flow rate of wood pellet, the lower heating value(LHV) of the wood pellet, mass flow rate and temperature of water for floor heating and so on. We measured the mass flow rate of fuel, wood pellet with respect to rotational speed of auger, wood pellet feeding screw. We also measured the flue gas concentration of the wood pellet boiler by using a gas analyser. The result shows that the efficiency of the wood pellet boiler is 80.6% based on lower heating value at 124 kW of heating output. At this condition, O2 concentration of the flue gas is 6.0%, CO and NOx concentrations are 85 and 102 ppm.

  • PDF

Development of a Power-tiller TMF Mixer (동력경운기 견인형 TMF 배합기의 개발)

  • Jo, Gi-Hyeon;Lee, Jeong-Taek;Baek, Lee
    • Journal of Biosystems Engineering
    • /
    • v.28 no.2
    • /
    • pp.97-106
    • /
    • 2003
  • One of the obstructing factors against managing dairy fm has been heavy labor requirement for feeding dairy cows. A Power-tiller TMF mixer was developed to reduce the cost and to provide economic benefit. The TMF mixer was desisted by the feeding capacity of 20∼30 heads at a batch with various functioning systems of auger type mixer, delivery conveyer, weighing console, pipe heater type heating system, power transmission train and mounting trailer. According to the study resulted, it showed that 1,200rpm, 1,600rpm, 2,000rpm and 2,300rpm were 6ps. Bps, lops and 12ps respectively. and that reduced shaft output by 15%. On the fodder mixer attached powertiller, initial output was necessary large torque. And the heating system was maintaining uniform temperature 60$^{\circ}C$ relatively.

Thermal Nitridation of Si by RF Induction Heating (고주파 유도 가열에 의한 Si의 열적질화)

  • 이용현;왕진석
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.9
    • /
    • pp.1386-1392
    • /
    • 1990
  • Characteristics of the direct thermal nitrided films by RF induction heating has been studied. The nitrided films on Si were prepared at 1000-1200\ulcorner in ammonia gas ambient. The nitrided films were analyzed by ellipsometry an Auger electron spectroscopy. I-V and C-V characteristics of MIS capacitors fabricated using nitrided film were investicated. The nitrided films were grown up mostly within initial thirty minutes and no significant growth was observed thereafter. Etch rates of films were about 1\ulcornermin in diluted HF (HF:H2O= 1:50). The nitrided films were resistant to dry and wet oxidations at temperatures below 1000\ulcorner and 900\ulcorner, respectively.

  • PDF

Thermal Shock Behavior of TiN Coating Surface by a Pulse Laser Ablation Method

  • Noh, Taimin;Choi, Youngkue;Jeon, Min-Seok;Shin, Hyun-Gyoo;Lee, Heesoo
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.7
    • /
    • pp.539-544
    • /
    • 2012
  • Thermal shock behavior of TiN-coated SUS 304 substrate was investigated using a laser ablation method. By short surface ablation with a pulse Nd-YAG laser, considerable surface crack and spalling were observed, whereas there were few oxidation phenomena, such as grain growth of TiN crystallites, nucleation and growth of $TiO_2$ crystallites, which were observed from the coatings quenched from $700^{\circ}C$ in a chamber. The oxygen concentration of the ablated coating surface with the pulse laser also had a lower value than that of the quenched coating surface by Auger electron spectroscopy and electron probe micro analysis. These results were attributed to the fact that the properties of the pulse laser method have a very short heating time and so the diffusion time for oxidation was insufficient. Consequently, it was verified that the laser thermal shock test provides a way to evaluate the influence of the thermal shock load reduced oxidation effect.

Effects of Heat Treatment Temperature on Oxidation Behavior in Ni-Ti Alloy (Ni-Ti 합금의 산화거동에 영향을 미치는 열처리 온도의 영향)

  • Kim, K.S.;Kim, W.C.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.1
    • /
    • pp.3-7
    • /
    • 2009
  • Variation in oxidation behavior with heat treatment temperature is investigated for a Ni-Ti alloy using X-ray diffraction, DSC (differential scanning calorimetry) and Auger electron spectroscopy. And the effect of oxidation on transformation behavior and superelasticity is characterized. A cold-worked 50.6Ni-Ti alloy is oxidized at 300-$700^{\circ}C$ for 1 hr in the air atmosphere. With an increase in heating temperature, the structure of $TiO_2$ changes from amorphous (300 and $400^{\circ}C$) to anatase ($500^{\circ}C$), and to rutile ($700^{\circ}C$). Activation energy of oxidation for NiTi is measured to be 51 Kcal/mol when heating temperature is $500^{\circ}C$ or above. Since Ti reacts preferably with oxygen, Ni content increases between matrix and oxide, forming $Ni_{3}Ti$ compounds. The resultant of oxidation decreases significantly $M_s$ and $A_s$ temperature in the specimen oxidized at $900^{\circ}C$ with $B_2{\rightarrow}M$ transformation path. An extra is found on cooling between two peaks in the specimen with $B_2{\rightarrow}R{\rightarrow}M$ one which is oxidized at $900^{\circ}C$ and aged at $500^{\circ}C$. Oxidation deteriorates superelasticity due to formation of Ni-rich compound.

AES Analysis of Au, Au/Cr, Au/Ni/Cr and Au/Pd/Cr Thin Films by the Change of Substrate Temperature and Annealing Temperature (기판온도와 열처리온도의 변화에 따른 Au/Cr, Au/Ni/Cr 및 Au/Pd/Cr 다층박막의 AES 분석)

  • Yoo, Kwang Soo;Jung, Hyung Jin
    • Analytical Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.217-223
    • /
    • 1993
  • Thin films of the Au/Cr, Au/Ni/Cr and Au/Pd/Cr systems were deposited on alumina substrates at ambient temperature and $250^{\circ}C$ in a high-vacuum resistance heating evaporator and annealed at $300^{\circ}C$, $450^{\circ}C$ and $600^{\circ}C$ for 1 hour in air, respectively. The film thicknesses of Au, Ni(or pd), and Cr were $1000{\AA}$, $300{\AA}$, and $50{\AA}$, respectively. The substrate temperature during deposition and the post-deposition annealing temperature affected the sheet resistance of thin-films due to the inter-diffusion of each layer. As a result of Auger depth profile analysis, in the Au/Cr system Cr already diffused out to Au surface during deposition at the substrate temperature of $250^{\circ}C$ and Au distribution changed after heat treatment. In the Au/Ni/Cr and Au/Pd/Cr systems, diffusion phenomena of Ni and Pd were found and especially Ni (approximately 45 at.%) diffused out to Au surface and oxidized.

  • PDF