• Title/Summary/Keyword: Au particle

Search Result 108, Processing Time 0.022 seconds

The Separation of Colloid Particles of Different Sizes by Dielectrophoresis (유전이동을 이용한 콜로이드 입자의 크기에 따른 분리)

  • Hwang, Yeon
    • Korean Journal of Materials Research
    • /
    • v.17 no.3
    • /
    • pp.167-172
    • /
    • 2007
  • The separation of the small colloidal particles from the mixture of two different sized particles using AC dielectrophoresis phenomenon was studied. The spherical mono-dispersed polystyrene particles dispersed in pure water were put into a perfusion chamber on a substrate, and AC electric fold was applied to the glass substrate with Au electrodes in 4 mm distance. The AC frequency was fixed at 1 kHz and the intensity of the field was varied from 25 V/cm to 160 V/cm. After applying the AC field, the degree of the chain formation that resulted from the particle movements by dielectrophoresis was observed by optical microscope. The mixture of the $1\;{\mu}m\;and\;5\;{\mu}m$ sized polystyrene particles at 0.5 vol% concentrations for each size was set in the dielectrophoresis conditions of 1 kHz and 100 V/cm. At this condition large $5\;{\mu}m$ sized polystyrene particles formed chains, on the contrary the $1\;{\mu}m$ sized polystyrene particles formed no chains. After water flowing for 20 min, it was found that small particles that were floating in the chamber had been removed by the water flowing.

Heat Flow Studies in Low Temperature Detectors (저온검출기의 열전도 연구)

  • Kim, Il-Hwan;Lee, Min-Kyu;Kim, Yong-Hamb
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.41-45
    • /
    • 2010
  • Low temperature micro-calorimeters have been employed in the field of high resolution alpha spectrometers. These alpha detectors typically consist of a superconducting or metal absorber and a temperature sensor. The temperature sensor can be a transition edge sensor (TES), a metallic magnetic calorimeter (MMC) or other low temperature detectors for an accurate measurement of temperature change due to an alpha particle absorption. We report a recent study of the heat flow between a replaceable absorber and a temperature sensor. A piece of gold foil in $2.4{\times}2.7{\times}0.03\;mm^3$ is used as an absorber. A $40\;{\mu}m$ diameter Au:Er paramagnetic sensor is attached to another small piece of gold foil in $400{\times}200{\times}30\;{\mu}m^3$ to serve as the temperature sensor. This sensor assembly, Au:Er and gold foil, is placed on a miniature SQUID susceptometer in a gradiometric configuration. The thermal connection between the absorber and the sensor was made with three gold bonding wires. The measured thermal conductance shows a linear dependence to the temperature. The values are in a good agreement with Wiedemann-Franz type thermal conductance of the gold wires.

Three-Dimensional Self-Assembled Micro-Array Using Magnetic Force Interaction

  • Park, Yong-Sung;Kwon, Young-Soo;Eiichi Tamiya;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.5
    • /
    • pp.182-188
    • /
    • 2003
  • We have demonstrated a fluidic technique for self-assembly of microfabricated parts onto substrate using patterned shapes of magnetic force self-assembled monolayers (SAMs). The metal particles and the array were fabricated using the micromachining technique. The metal particles were in a multilayer structure (Au, Ti, and Ni). Sidewalls of patterned Ni dots on the array were covered by thick negative photoresist (SU-8), and the array was magnetized. The array and the particles were mixed in buffer solution, and were arranged by magnetic force interaction. Binding direction of the metal particle onto Ni dots was controlled by multilayer structure and direction of magnetization. A quarter of total Ni dots were covered by the particles. The binding direction of the particles was controllable, and condition of particles was almost even with the Au surface on top. The particles were successfully arranged on the array.

An integrated DNA barcode assay microdevice for rapid, highly sensitive and multiplex pathogen detection at the single-cell level

  • Jung, Jae Hwan;Cho, Min Kyung;Chung, So Yi;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.276-276
    • /
    • 2013
  • Here we report an integrated microdevice consisting of an efficient passive mixer, a magnetic separation chamber, and a capillary electrophoretic microchannel in which DNA barcode assay, target pathogen separation, and barcode DNA capillary electrophoretic analysis were performed sequentially within 30 min for multiplex pathogen detection at the single-cell level. The intestine-shaped serpentine 3D micromixer provides a high mixing rate to generate magnetic particle-pathogenic bacteria-DNA barcode labelled AuNP complexes quantitatively. After magnetic separation and purification of those complexes, the barcode DNA strands were released and analyzed by the microfluidic capillary electrophoresis within 5 min. The size of the barcode DNA strand was controlled depending on the target bacteria (Staphylococcus aureus, Escherichia coli O157:H7, and Salmonella typhimurium), and the different elution time of the barcode DNA peak in the electropherogram allows us to recognize the target pathogen with ease in the monoplex as well as in the multiplex analysis. In addition, the quantity of the DNA barcode strand (~104) per AuNP is enough to be observed in the laser-induced confocal fluorescence detector, thereby making single-cell analysis possible. This novel integrated microdevice enables us to perform rapid, sensitive, and multiplex pathogen detection with sample-in-answer-out capability to be applied for biosafety testing, environmental screening, and clinical trials.

  • PDF

Optical Property of Au-doped $TIO_2/SiO_2$ thin film (금 나노미립자가 함침된 $TiO_2/SiO_2$ 박막의 광학적 성질)

  • Jung, Mie-Won;Kim, Ji-Eun;Lee, Kyung-Chul
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.1
    • /
    • pp.60-67
    • /
    • 2000
  • The wavelength of the surface plasmon absorption depends on the dielectric matrix. $TiO_2/SiO_2$ complex oxide films doped with Au nanoclusters were prepared by sol-gel spin-coating method using $Ti(OPr^i)_4$, $Si(OEt)_4$, and $HAuCl_4{\cdot}7H_2O$. The wavelength of the maximum absorption of Au nanoehrsters in the $TiO_2/SiO_2$ thin films was obtained with lineality from 540 nm to 615 nm depending on the molar ratio of $TiO_2$. The particle sizes and structures of these nanoclusters have been identified through a TEM and X-ray diffraction patterns. The dielectric constants of $TiO_2/SiO_2$ thin films were calculated from the experimental results.

  • PDF

The Effective Recovery of Gold from the Invisible Gold Concentrate Using Microwave-nitric Acid Leaching Method (마이크로웨이브-질산침출방법에 의한 비가시성 금의 회수율 향상)

  • Lee, Jong-Ju;Myung, Eun-Ji;Park, Cheon-Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.185-200
    • /
    • 2019
  • This study aimed to liberate gold from invisible gold concentrate (Au = 1,840.00 g/t) through microwave nitric acid leaching experiments. For the purpose, this study conducted microwave-nitric acid leaching experiments and examined nitric acid concentration effect, microwave leaching time effect and sample addition effect. The results of the experiments were as follows: Au (gold) contents were not detected in all of the microwave leaching conditions. In the insoluble-residue, weight loss rate tended to decrease as the nitric acid concentration, microwave leaching time and sample addition increased. In an XRD analysis with solid-residue, it was suggested that gypsum and anglesite were formed due to dissolution of calcite and galena by nitric acid solution. When a fire assay was carried out with insoluble-residue, it was discovered that gold contents of the solid-residue were 1.3 (Au = 2,464.70 g/t) and 28.8 (52,952.80 g/t) times more than those of concentrate. But in the gold contents recovered, a severe gold nugget effect appeared. It is expected that the gold nugget effect will decrease if a sampling method of concentrate is improved in the microwave-nitric acid leaching experiments and filtering paper with smaller pore size is used for leaching solution and burned filter paper is used for sampling in lead-fire assay.

Carbonic Anhydrase Mimicry for Carbon Dioxide Fixation and Calcium Carbonate Mineralization (탄산탈수효소 모사를 이용한 이산화탄소 고정화 및 탄산칼슘 합성)

  • Sahoo, Prakash C.;Jang, Young Nam;Chae, Soo Chun;Lee, Seung Woo
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.201-208
    • /
    • 2013
  • Copper (II) and Nickel (II) mimic complexes of enzyme carbonic anhydrase were evaluated under ambient condition for carbon dioxide capture and conversion process. The synthesized complexes were characterized by ATR-FTIR and UV-DR spectroscopy. It was found that all the complexes have biomimetic activity towards $CO_2$ using para-nitrophenyl acetate (p-NPA) hydrolysis as the model reaction. Interestingly, the proper geometry obtained by the restricted orientation of tripodal N atoms in Cu (II) complex of 2,6-bis(2-benzimidazolyl) pyridine showed the highest activity (1.14 au) compared to others. The $CO_2$ bio-mineralization to $CaCO_3$ was carried out via in-vitro crystallization approach. Results indicate that the biomimetic complexes have a role in determining $CaCO_3$ morphology. The present observations establish a qualitative insight for the design of improved small-molecule catalysts for carbon capture.

Characterization of Physical Processes and Secondary Particle Generation in Radiation Dose Enhancement for Megavoltage X-rays (MV X선의 방사선 선량 증강 현상에서 물리적 특성과 이차입자의 발생)

  • Hwang, Chulhwan;Kim, JungHoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.791-799
    • /
    • 2019
  • We evaluated the physical properties that occur to dose enhancement and changes from secondary particle production resulting from the interaction between enhancement material. Geant4 was used to perform a Monte Carlo simulation, and the medical internal radiation dose (MIRD) head phantom were employed. X-rays of 4, 6, 10, 15, 18, and 25 MV were used. Aurum (Au) and gadolinium (Gd) were applied within the tumor volume at 10, 20, and 30 mg/g, and an experiment using soft tissue exclusively was concomitantly performed for comparison. Also, particle fluence and initial kinetic energy of secondary particle of interaction were measured to calculate equivalent doses using the radiation weight factor. The properties of physical interaction by the radiation enhancement material showed the great increased in photoelectric effect as compared to the compton scattering and pair production, occurred with the highest, in aurum and gadolinium it is shown in common. The photonuclear effect frequency increased as the energy increased, thereby increasing secondary particle production, including alpha particles, protons, and neutrons. During dose enhancement using aurum, a maximum 424.25-fold increase in the equivalent dose due to neutrons was observed. This study was Monte Carlo simulation corresponds to the physical process of energy transmission in dose enhancement. Its results may be used as a basis for future in vivo and in vitro experiments aiming to improve effects of dose enhancement.

Beta-spectra for the Radionuclides in Medicine

  • Yi, Chul-Young;Kim, Kyung-Hwa;Park, Kyung-Bae;Han, Hyon-Soo;Jun, Jae-Shik;Chai, Ha-Seok
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.37-46
    • /
    • 1998
  • Beta-particle energy distributions of the radionuclides in medicine are calculated for the medical physics applications. The radial component solutions of Dirac wave equations are evaluated for a point-nucleus un screened Coulomb potential. The WKB method is employed to correct the screening due to the orbital-electron cloud. Fierz interference terms are ignored. The radionuclides considered are $\^$32/P, $\^$90/Y, $\^$131/I, $\^$166/Ho, $\^$192/Ir, $\^$198/Au, $\^$153/Sm, $\^$169/Er and $\^$188/Re. A total of 9 beta-spectra for the radionuclides, currently in domestic use or potential use in the near future, are calculated with enough accuracy and presented in graphs and tables.

  • PDF

폐금속광산 주변 오염물질의 안정화 처리

  • Gwon Ji-Cheol;Jeong Myeong-Chae;Jeong Mun-Yeong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.41-44
    • /
    • 2006
  • The objective of this study was to evaluate the stabilization of As and heavy metals in tailings from the Samkwang Au-Ag mine with $Ca(OH)_2$. In order to evaluate the stabilization ability of As and heavy metals in the tailings, column test was implemented with various conditions as 1) particle size of $Ca(OH)_2$, 2) mixing method and 3) flow rate of eluents during 60 days. The results showed that addition with 5% of $Ca(OH)_2$ in 1kg of the tailings had the most effective ability of stabilization up to 95%. In addition, stabilization ability of As and heavy metals in tailings was enhanced using a fine powder of $Ca(OH)_2$. Therefore, stabilization technology can be used as a remediation of As and heavy metals in mine wastes including tailings and a nearby soils from abandoned metal mines.

  • PDF