• 제목/요약/키워드: Attenuation Measurement

검색결과 392건 처리시간 0.023초

가토 신동맥의 고농도 Histamine에 의한 노아드레날린 유발 수축 및 K-경축 약화 기전 (Effects of Histamine Pretreatment on the subsequent Noradrenaline-induced Contraction and $K^+-Contracture$ in Rabbit Renal Artery)

  • 이성우;김세훈;장석종;박해근
    • The Korean Journal of Physiology
    • /
    • 제23권2호
    • /
    • pp.351-361
    • /
    • 1989
  • The contraction of renal arterial strip by no.epineph.me (NE) or 40 mM $K^+$ were Significantly attenuated after histamine $(10^{-5}\;M)-induced$ contraction. The mechanisms of this phenomenon were investigated in the helical strips of isolated renal artery with the measurement of isometric tension. The arterial strip was immersed in the tris-buffered Tyrode's solution which was equilibrated with 100% $O_2\;at\;35^{\circ}C$. The contraction was induced by NE or 40 mM $K^+$ during the recovery from the histamine-induced contraction which lasted for 15 minutes. The contraction by NE was also attenuated in the $Ca^{2+}-free$ Tyrode's solution and the increase of contraction by addition of 2 mM $Ca^{2+}$ was attenuated as well. This attenuation phenomenon was not observed in the presence of low concentration $(3{\times}10^{-7}\;M)$ of histamine. This attenuation was not affected by destruction of endothelium, pretreatment with papaverine or propranolol. This attenuation was partially inhibited by pretreatment of ouabain or in low $K^+(0.5 mM)$ Tyrode's solution. But the attenuation in the $Ca^{2+}-free$ Tyrode's solution was not inhibited. Furthermore this attenuation was completely blocked by pretreatment of djphenhydramine $(H_1-receptor blocker)$ and potentiated by pretreatment of cimetidine $(H_2-receptor\;blocker)$. This attenuation Phenomenon was disappeared after recovery of 1 hour. From the above results, it is suggested that the attenuation phenomenon may be resulted partially from the activation of $Na^+-K^+$ exchange pump and partially from the depletion of intracellular $Ca^{2+}$ pool after the histamine-induced contraction mediated through $H_1-receptor$ function.

  • PDF

감쇄극 인버터를 이용한 반파장 Partial H-Plane 여파기 (Half Wavelength Partial H-Plane Filter with Inverters having Attenuation Poles)

  • 김동진;이정해
    • 한국전자파학회논문지
    • /
    • 제19권2호
    • /
    • pp.107-113
    • /
    • 2008
  • 본 논문에서는 차단 영역 도파로로 구현된 협소한 형태의 H-plane slot을 이용하여 다수의 감쇄극을 가지는 반파장 partial H-plane filter를 제안하였다. 협소한 형태의 H-plane slot은 대역 통과 필터의 어드미턴스 인버터 역할을 하는 동시에 특정 주파수에서 공진을 발생시킨다. 따라서 제안된 필터는 어떠한 부가적인 coupling이나 추가적인 구조의 변형 없이 저지 대역에서 감쇄극을 가지는 간단한 구조로 구현되고, 감쇄극 수는 인가되는 slot의 수만큼 발생된다. 제안된 필터는 일반적인 도파로의 1/4의 단면적을 가지는 partial H-plane waveguide로 설계되므로 소형화에 유리하다 저지 대역에서 각각 4개와 5개의 감쇄극을 갖는 3단과 4단 반파장 대역 통과 필터를 H-band에서 설계하여, 이론적 주파수 응답 특성이 실험적 응답 특성과 잘 일치함을 확인하였다.

AAPM CT 성능 팬텀의 CT영상에서 물 유효선감쇠계수의 백분율에 의한 노이즈 측정 (Noise Measurement by Percentage of Effective Linear Attenuation Coefficient of Water in CT Image of AAPM CT Performance Phantom)

  • 김종언;이상훈
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.771-778
    • /
    • 2022
  • 이 연구의 목적은 임상에서 AAPM CT 성능 팬텀을 이용한 CT영상 노이즈 정도관리에 사용할 수 있는 물 유효선감쇠계수의 백분율에 의한 노이즈 측정의 방법을 제시하는 데 있다. 120 kVp CT X-선 빔으로 AAPM CT 성능 팬텀을 스캔하여 얻어진 CT영상에서, CT수 직선성 삽입부분의 각 핀과 물에 대하여 평균 CT수를 측정하였다. 유효에너지는 각 핀과 물에 대하여 측정된 평균 CT수와 광자에너지별 선감쇠계수의 선형회귀분석의 상관계수들로부터 가장 큰 상관계수를 갖는 광자에너지로 결정하였다. 그리고 물과 아크릴에 대하여 측정된 평균 CT수와 유효선감쇠계수로부터 대조도 척도는 0.000188 cm-1 · HU-1으로 산출되었다. 산출된 대조도 척도, 물 유효선감쇠계수, 그리고 AAPM CT 성능 팬텀에서 고정핀 부분의 물에서 측정된 표준편차를 사용하여, 물 유효선감쇠계수의 백분율에 의한 노이즈 측정값은 100 ~ 300 mAs의 범위에서 0.31 ~ 0.52%를 얻었다.

메탄 하이드레이트 부존 퇴적층으로부터 획득한 수직탄성파 (VSP) 자료에서의 탄성파 진폭 감쇠 (Seismic attenuation from VSP data in methane hydrate-bearing sediments)

  • 송도 윤
    • 지구물리와물리탐사
    • /
    • 제10권1호
    • /
    • pp.29-36
    • /
    • 2007
  • 최근의 탄성파 탐사들은 퇴적층에 메탄 하이드레이트가 존재할 경우 탄성파 진폭 감쇠에 큰 영향을 미치는 것을 보여주고 있다. 이 논문에서는 일본 중부 토카이(Tokai) 해역의 난카이 트러프 (Nankai Trough) 탐사정에서 얻은 수직탄성파자료를 이용하여 30$\sim$110 Hz 주파수 대역에서 메탄 하이드레이트 부존층에서의 P 파 감쇠를 측정하였다. 두 개의 다른 측정방법들 (스펙트럼비 (spectral ratio) 방법과 중심 주파수 이동방법 (centroid frequency shift method))을 이용하여 감쇠 측정의 유효성을 조사하였다. 또한 감쇠 측정의 안정성을 증명하기 위해 측정 심도구간, 시추공의 불규칙 변화, 주파수 구간에 따른 감쇠 분석의 민감도를 조사하였다. 탄성파 주파수 대역에서는 메탄 하이드레이트 부존층에서 P 파의 큰 진폭 감쇠는 발견되지 않았다. 육안으로 보기에는 탄성파 주파수 대역에서의 최대 감쇠는 저포화도의 가스층에 발생한다. 그와는 반대로 같은 시추공에서 얻어진 음파검층의 주파수 대역 $(10{\sim}20\;kHz)$에서는 가장 높은 P 파의 진폭 감쇠가 메탄 하이드레이트 부존층과 관련이 있었다. 그러므로 이 연구는 메탄 하이드레이트 부존 퇴적층의 진폭 감쇠가 주파수에 의존함을 보여주고 있다. 메탄 하이드레이트 부존층은 탄성파 주파수 대역보다는 음파검층 주파수 대역에서 진폭 감쇠를 유발함을 알 수 있다. $30{\sim}110\;Hz$의 탄성파 주파수 대역이 메탄 하이드레이트 부존에 영향을 받지 않는 이유 중의 하나로서 메탄 하이드레이트 지역의 얇은층 들로 이루어진 층서구조의 영향을 제시하였다.

세기변조방사선치료의 정도관리를 위한 두경부 팬톰 제작에 관한 연구 (The Study on the Head and Neck Phantom for Quality Assurance of Intensity Modulated Radiotherapy)

  • 신동호;박성용;김주영;이세병;조정근;김대용;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제16권1호
    • /
    • pp.39-46
    • /
    • 2005
  • m3 (BrainLAB Inc., Germany)를 이용한 두경부 IMRT의 정도관리에서 테이블과 갠트리의 위치에 따라 테이블에 의한 선량감쇠가 일어나 정확한 처방 선량을 측정할 수 없다. 이 문제를 해결하기 위해 두경부 종양의 세기변조방사선치료를 위해 Brain Lab사의 환자테이블 mount를 이용해 설치할 수 있는 원통형 두경부 팬톰을 제작하였다. 이를 이용하여 환자테이블에 의한 선량 감쇠를 측정하고 실제 임상에 적용함으로써 테이블에 의한 선량 감쇠로 인한 선량분포의 차이를 확인할 수 있었다. 측정결과 환자테이블에 의한 점 선량의 감쇠가 최대 약 35%가 났으며 실제 환자 치료계획에 대한 정도관리에서의 절대점 선량의 경우 5.4%의 선량차이를 나타냈다.

  • PDF

2파장 보정 Laser-Induced Incandescence 법을 이용한 매연 농도 측정 (Quantitative Measurement of Soot concentration by Two-Wavelength Correction of Laser-Induced Incandescence Signals)

  • 정종수
    • 한국자동차공학회논문집
    • /
    • 제5권3호
    • /
    • pp.54-65
    • /
    • 1997
  • To quantify the LII signals from soot particle of flames in diesel engine cylinder, a new method has been proposed for correcting LII signal attenuated by soot particles between the measuring point and the detector. It has been verified by an experiment on a laminar jet ethylene-air diffusion flame. Being proportional to the attenuation, the ratio of LII signal at two different detection wavelengths can be used to correct the measured LIIsignal and obtain the unattenuated LII signal, from which the soot volume fraction in the flame can be estimated. Both the 1064-nm and frequency-doubled 532-nm beams from the Nd : YAG laser are used. Single-shot, one-dimensional(1-D) line images are recorded on the intensified CCD camera, with the rectangular-profile laser beam using 1-mm-diameter pinhole. Two broadband optical interference filters having the center wavelengths of 647 nm and 400 nm respectively and a bandwidth of 10 nm are used. This two-wavelength correction has been applied to the ethylene-air coannular laminar diffusion flame, previously studied on soot formation by the laser extinction method in this laboratory. The results by the LII measurement technique and the conventional laser extinction method at the height of 40 nm above the jet exit agreed well with each other except around outside of the peaks of soot concentration, where the soot concentration was relatively high and resulting attenuation of the LII signal was large. The radial profile shape of soot concentration was not changed a lot, but the absolute value of the soot volume fraction around outside edge changed from 4ppm to 6.5 ppm at r=2.8mm after correction. This means that the attenuation of LII signal was approximately 40% at this point, which is higher than the average attenuation rate of this flame, 10~15%.

  • PDF

초음파 검사 영상의 정량적인 측정 연구를 통한 지방간 분석 (Fatty Liver Analysis through Quantitative Measurement Study of Ultrasonography Images)

  • 천혜리;장현철
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.927-934
    • /
    • 2022
  • 본 연구는 간 초음파 영상을 활용하여 정량적인 측정 분석을 통해 조직 내 감쇠 지수, 조직 내 산란 분포지수 값 분석과 함께 초음파 영상 소견 간 일치도를 알아보고자 하였다. 2022년 8월부터 2022년 10월까지 지방간이 의심되어 간 초음파 검사 처방을 받은 45명의 환자를 대상으로 간 초음파 검사를 시행하였다. 연구결과, 초음파 영상 소견과 조직 내 감쇠 지수 간 일치도 분석 결과 Kappa 값이 0.82(p<0.05)로 두 검사 방법 간 매우 높은 일치도를 보였다. 또한, 초음파 영상 소견과 조직 내 산란 분포 지수 간 일치도 분석 결과에서도 Kappa 값이 0.642(p<0.05)로 두 검사 방법 간 높은 일치도를 보였다. 지방간 예측 시 간 초음파 소견 및 정량적인 초음파 검사 기법인 조직 내 감쇠 지수, 조직 내 산란 분포 지수를 활용한다면 지방간 환자의 진행 정도를 판단할 때 도움이 될 수 있을 것으로 생각된다.

Measurement of DS-CDMA Propagation Distance in Underwater Acoustic Communication Considering Attenuation and Noise

  • Lee, Young-Pil;Moon, Yong Seon;Ko, Nak Yong;Choi, Hyun-Taek;Huang, Linyun;Bae, Youngchul
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제15권1호
    • /
    • pp.20-26
    • /
    • 2015
  • It is very difficult to design an underwater communication system because of multipath, Doppler effects, noise, and attenuation. These factors lead to errors in the communication performance and maximum propagation distance. In this study, we calculate the distance that can be realized using the direct-sequence code division multiple access (DS-CDMA) technique with direct-sequence spread spectrum (DSSS) in an underwater communication system considering only the attenuation and noise. We also compare the estimated and calculated propagation distances obtained for several different scenarios.

ULTRASONIC PROPERTY OF RADISH UNDER COMPRESSION LOAD

  • Lu, F.M.;Huang, W.J.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.543-550
    • /
    • 2000
  • The objective of this research was to study the effect of contact force of ultrasonic probe on the ultrasonic attenuation measurement of radish. The relationship between ultrasonic attenuation (y) and contact force (x) for radish can be expressed as equation y=a+bLn(x), where a=8.7194+2.l68x(porosity) and b =-9.9188+0.0075 ${\times}$ (volume). The relationship between ultrasonic power spectrum (y) and contact force (x) for radish is also represented by equation y=a+bLn(x), where a= 60.l965-1.47l4${\times}$(porosity). The coefficient b has no significant relation with radish properties.

  • PDF

콘크리트의 손상 평가를 위한 초음파 감쇠량 측정법 (Ultrasonic Wave Attenuation Measurement for Damage Characterization of Concrete)

  • 곽효경;임홍재;김재홍
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.85-86
    • /
    • 2009
  • 이 논문에서는 자기보상 주파수 응답 함수 기법을 적용하여, 콘크리트 재료의 감쇠계수를 정량적으로 측정할 수 있는 기법을 제안하였다. 제안된 기법은 상대적인 감쇠량이 아닌, 재료 고유의 감쇠 계수를 측정할 수 있으며, 감쇠계수 측정 실험을 통해 제안된 기법의 재현성 및 정확성을 검증하였다.

  • PDF