• 제목/요약/키워드: Attenuation Effect

검색결과 583건 처리시간 0.03초

In-line Variable Optical Attenuator Based on the Bending of the Tapered Single Mode Fiber

  • Kim, Kwang-Taek;Kang, Ji-Hoon;HwangBo, Seung;Im, Kie-Gon
    • Journal of the Optical Society of Korea
    • /
    • 제13권3호
    • /
    • pp.349-353
    • /
    • 2009
  • We propose a simple in-line variable optical attenuator (VOA) based on the bending effect of tapered single mode fibers. The influence of the taper structure and the reflective index of the external medium surrounding the taper region on the bending loss of the tapered fiber have been investigated experimentally. An attenuation range exceeding 35 dB and a very low excess loss of < 0.2 dB at 1550 nm were achieved. The measured polarization dependent loss of the present VOA at the attenuation level of 10 dB, 20 dB, and 30 dB were 0.1 dB, 0.2 dB, and 0.5 dB, respectively.

진동모드에 따른 각종 장갑의 방진효과 분석 (An Analysis of Vibration Attenuation Effect of the different type of Gloves and Drilling Mode)

  • 황성환;이형일;이동충
    • 산업경영시스템학회지
    • /
    • 제24권69호
    • /
    • pp.65-73
    • /
    • 2001
  • The objective of this study is to evaluate the vibration attenuation effects of the different type of gloves and drilling mode while operating a light-weighted powered hand drill. For the experimental design, five different kinds of glove(barehanded cotton partly coated anti-vibration, and open-finger vibration glove) two types of push force level(100N and 200N) and two types of drilling mode(impact and non-impulsive) were considered. Six healthy male subjects were employed to drive screws into a vertically mounted marble plate with a powered hand drill in a randomly ordered experimental conditions. The findings of this study are summarized as follows; (1) It was found that the best combination of overall BMS transmissibility was using impact drilling mode with anti-vibration glove among evaluated experimental conditions (2) The wearing open finger vibration glove in mid-frequency level and anti-vibration glove with impact drill in high-frequency were the best in the result from mean corrected transmissibility equation of ISO 10819.

  • PDF

Guided viscoelastic wave in circumferential direction of orthotropic cylindrical curved plates

  • Yu, Jiangong;Ma, Zhijuan
    • Structural Engineering and Mechanics
    • /
    • 제41권5호
    • /
    • pp.605-615
    • /
    • 2012
  • In this paper, guided circumferential wave propagating in an orthotropic viscoelastic cylindrical curved plate subjected to traction-free conditions is investigated in the frame of the Kelvin-Voight viscoelastic theory. The obtained three wave equations are decoupled into two groups, Lamb-like wave and SH wave. They are separately solved by the Legendre polynomial series approach. The availability of the method is confirmed through the comparison with the published data of the SH wave for a viscoelastic flat plate. The dispersion curves and attenuation curves for the carbon fiber and prepreg cylindrical plates are illustrated and the viscous effect on dispersion curves is shown. The influences of the ratio of radius to thickness are analyzed.

Characteristics of $\pi$-type attenuators using Ti(N) thin film resistors

  • Cuong, Nguyen Duy;Kim, Dong-Jin;Kang, Byoung-Don;Yoon, Soon-Gil
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.50-50
    • /
    • 2007
  • We report the effect of the film thickness on electrical properties of Ti(N) film resistors. The applications of titanium nitride thin film resistor in $\Pi$-type attenuators are also characterized. As film thickness decreases from 100 to 30 nm, temperature coefficient of resistance significantly decreases from -60 to -148 ppm/K, while sheet resistance increases from 37 to $270\;{\Omega}/{\square}$. The characterizations of 20dB-attenuators using thin film resistors are improved in comparison with those using thick film resistors. The $\Pi$-type attenuators using Ti(N) thin film resistors exhibit a attenuation of -19.94 dB and voltage standing wave ratio of 1.16 at a frequency of 2.7 GHz.

  • PDF

Plane harmonic waves in fractional orthotropic magneto-thermoelastic solid with rotation and two-temperature

  • Himanshi;Parveen Lata
    • Coupled systems mechanics
    • /
    • 제12권2호
    • /
    • pp.103-125
    • /
    • 2023
  • The present research is focused on the study of plane harmonic waves in a two-dimensional orthotropic magneto-thermoelastic media with fractional order theory of generalized thermoelasticity in the light of two-temperature and rotation due to time harmonic sources. Here, we studied three types of waves namely quasi-longitudinal (QL), quasi-transverse (QTS) and quasi thermal (QT) waves. The variations in the wave properties such as phase velocity, attenuation coefficient and specific loss have been noticed with respect to frequency for the reflected waves. Further the value of amplitude ratios, energy ratios and penetration depth are computed numerically with respect to angle of incidence. The numerical simulated results are presented graphically to show the effect of fractional parameter based on its conductivity (0<α<1 for weak, α=1 for normal, 1<α≤2 for strong conductivity) on all the components.

유방촬영용 X선장치의 선질 특성 (Measurement of X-ray Quality in Mammography Unit)

  • 이인자;김정민;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권2호
    • /
    • pp.5-10
    • /
    • 1998
  • In the mammography, X-ray beam quality is one of the most important factors. Using X-ray mammography unit model GE/CGR Senography 600T Senix H.F, Authors studied four subjects. 1. The aluminum attenuation rate in 30 kVp when used with or without compression plate. 2. HVLs at 5 different area of the X-ray field of $26{\sim}32kVp$. 3. HVLs to know the influence of corrected measurement or parallel measurement. 4. Film density with microdensitometer along and cross to the long axis of X-ray tube, in terms of the Heel effect in the X-ray field. The following results were obtained. 1. Beam quality of anode area was harder than cathode area. 2. The dose reduction rate of compression plate was approximately $65.5%{\sim}88.1%$ and the beam quality with compression plate was hardened up to 4kVp accordingly. 3. If the X-ray beam enters the attenuation plate obliquely, HVL was $2.6{\sim}2.9%$ harder than perpendicular to it. 4. Because of heel effect, the film density of cathode area is higher than anode area to film density of 0.5.

  • PDF

PET/CT검사에서 CT의 확대 유효시야 적용이 표준화섭취계수에 미치는 영향 (Effect of Extended Field of View on Measurements of Standardized Uptake Value in PET/CT)

  • 박순기;남기표;김경식;신상기
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.82-85
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of extended CT field of view (FOV) on PET/CT of Standardized uptake value (SUV) when imaging extends beyond the CT FOV. Materials and Methods: CT images were reconstructed at different FOV sizes (500 and 700 mm). Two sets of CT images were reconstructed from the CT projection data by using two FOV sizes. Twenty patients were used in this study. PET images were reconstructed using attenuation maps with 500 mm CT FOV and 700 mm extended CT FOV images. Region of interests (ROIs) drawn on the PET images. In addition, twenty patients' PET images reconstructed by 500 mm CT FOV and 700 mm extended CT FOV were compared with $SUV_{max}$. Results: When using attenuation maps with 700 mm extended CT FOV, the $SUV_{max}$ analysis of liver (p=0.000), lung (p=0.007), mediastinum (p=0.001) were statistically significant. Conclusions: 700 mm extended CT FOV helps to recover the true activity distribution in the PET emission data. In addition, 700 mm extended CT FOV has affected SUV measurement of liver, lung, mediastinum.

  • PDF

Experimental Investigation of Clay Fly Ash Bricks for Gamma-Ray Shielding

  • Mann, Harjinder Singh;Brar, Gurdarshan Singh;Mann, Kulwinder Singh;Mudahar, Gurmel Singh
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1230-1236
    • /
    • 2016
  • This study aims to determine the effect of fly ash with a high replacing ratio of clay on the radiation shielding properties of bricks. Some interaction parameters (mass attenuation coefficients, half value layer, effective atomic number, effective electron density, and absorption efficiency) of clay fly ash bricks were measured with a NaI(Tl) detector at 661.6 keV, 1,173.2 keV, and 1,332.5 keV. For the investigation of their shielding behavior, fly ash bricks were molded using an admixture to clay. A narrow beam transmission geometry condition was used for the measurements. The measured values of these parameters were found in good agreement with the theoretical calculations. The elemental compositions of the clay fly ash bricks were analyzed by using an energy dispersive X-ray fluorescence spectrometer. At selected energies the values of the effective atomic numbers and effective electron densities showed a very modest variation with the composition of the fly ash. This seems to be due to the similarity of their elemental compositions. The obtained results were also compared with concrete, in order to study the effect of fly ash content on the radiation shielding properties of clay fly ash bricks. The clay fly ash bricks showed good shielding properties for moderate energy gamma rays. Therefore, these bricks are feasible and eco-friendly compared with traditional clay bricks used for construction.

Effect of Heat Treatment on Radiation Shielding Properties of Concretes

  • Singh, Vishwanath P.;Tekin, Huseyin O.;Badiger, Nagappa M.;Manici, Tubga;Altunsoy, Elif E.
    • Journal of Radiation Protection and Research
    • /
    • 제43권1호
    • /
    • pp.20-28
    • /
    • 2018
  • Background: Heat energy produced in nuclear reactors and nuclear fuel cycle facilities interactions modifies the physical properties of the shielding materials containing water content. Therefore, in the present paper, effect of the heat on shielding effectiveness of the concretes is investigated for gamma and neutron. The mass attenuation coefficients, effective atomic numbers, fast neutron removal cross-section and exposure buildup factors. Materials and Methods: The mass attenuation coefficients, effective atomic numbers, fast neutron removal cross-section and exposure buildup factors of ordinary and heavy concretes were investigated using NIST data of XCOM program and Geometric Progression method. Results and Discussion: The improvement in shielding effectiveness for photon and reduction in fast neutron for ordinary concrete was observed. The change in the neutron shielding effectiveness was insignificant. Conclusion: The present investigation on interaction of gamma and neutron radiation would be very useful for assessment of shielding efficiency of the concrete used in high temperature applications such as reactors.

유도형 Linear Motor의 단부효과를 고려한 이동자계에 관한 연구 (Study On The Travelling Magnetic Field In The Linear Induction Motor With Its End Effect Taken Into Consideration)

  • 임달호
    • 전기의세계
    • /
    • 제21권4호
    • /
    • pp.7-14
    • /
    • 1972
  • The author has established a general equation for the travelling magnetic field in air gap with the end effect taken into consideration, which constitutes the basics for the analysis of characteristics of linear induction motor. This equation is verified by comparison of the experimental values with the theoretically calculated values. The properties of the travelling wave with attenuation, which is contained in the travelling magnetic field of linear induction motor, have been verified, and consequently the practicable equation is established with these effects taken into consideration. This provides the solid foundation for the theoretical analysis of the characteristics of the linear induction motor.

  • PDF