• Title/Summary/Keyword: Atomic Absorption Spectrometry

Search Result 120, Processing Time 0.028 seconds

Effects of Acid and Pre-Reductant in the Analysis of Arsenic by Hydride Generation-Atomic Absorption Spectrometry (HG-AAS법에 의한 비소 분석에서 산 및 Pre-Reductant가 분석에 미치는 영향)

  • Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.151-157
    • /
    • 2000
  • Effects of acids and pre-reductants in the analysis of arsenic have been studied by hydride generation-atomic absorption spectrometry. The analytical results were strongly dependent on the acid concentrations. All the pre-reductants was very effective to observe the arsenic signal at strong acid concentrations (3 M-5 M). However, at the low acid condition (${\leq}0.1M$), L-cysteine only showed a reasonable effect on the absorption signal. When the sample was treated with the nitric acid, absorption signal was unstable and was also decreased. Although interference effects were observed from metal ions such as $Cr^{6+}$ and $Br^{5+}$ at low acid condition, the generation of hydride could be increased by the strong acid condition.

  • PDF

Determination of Trace Elements in Atmospheric Dust by X-Ray Fluorescence Spectrometry(II) : X-ray Fluorescence Spectrometric Determination of Light Elements (형광 X선에 의한 대기분진중의 미량성분의 측정(II): 대기부유분진 중 경원소의 X-선 형광분석)

  • 이용근;박현미;이동수;이보경
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.247-254
    • /
    • 1993
  • A simple and direct method is developed for the determination of light Elements in atmospheric particulates by X-ray fluorescence spectrometry. Calibration standards for the light elements such as Al, Mg, K, Ca, etc are prepared by filtering real atmospheric particulates over variable time and subsequently standardizing them by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) or Atomic Absorption Spectrophotometry(AAS) analysis. The validity of this calibration method is tested by analyzing more than 100 aerosol samples, collected at urban(Seoul) and rural(Padori) sites over a two year period with this method and then comparing them with those by other accuracy proven methods such as AAS or ICP-MS: for all metals tested the results showed reasonably good agreements (R $\geq$ 0.95).

  • PDF

Impurity analysis and acid leaching purification of silica minerals (실리카광물의 산침출 정제와 불순물 분석법 연구)

  • Lee, Kil Yong;Yoon, Yoon Yeol;Cho, Soo Young;Chae, Young-Bae
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.516-523
    • /
    • 2007
  • Purification of silica mineral has been investigated by acid leaching of pulverized silica. A series of studies has been carried out on the effect of leaching silica powder as a function of the leaching time at the constant temperature of $80^{\circ}C$ in oxalic acid, aqua regia, and two mixed acids of HF/HCl, $HF/HNO_3$. The impurities of silica and leachantes were measured by neutron activation analysis (NAA), inductively coupled plasma atomic emission spectrometry (ICP-AES), atomic absorption spectrometry, x-ray fluorescence (XRF) method and wet analysis (WA). Certain metals, such as sodium, calcium, iron, aluminium and titanium, have been found in concentrations of hundreds or even thousands of mg/kg. Comparison of purification processes of silica and analytical methods of impurities in the silica was conducted in this study.

Hydrogen Absorption by Crystalline Semiconductors: Si(100), (110) and (111)

  • Jeong, Min-Bok;Jo, Sam-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.383-383
    • /
    • 2010
  • Gas-phase hydrogen atoms create a variety of chemical and physical phenomena on Si surfaces: adsorption, abstraction of pre-adsorbed H, Si etching, Si amorphization, and penetration into the bulk lattice. Thermal desorption/evolution analyses exhibited three distinct peaks, including one from the crystalline bulk. It was previously found that thermal-energy gaseous H(g) atoms penetrate into the Si(100) crystalline bulk within a narrow substrate temperature window(centered at ~460K) and remain trapped in the bulk lattice before evolving out at a temperature as high as ~900K. Developing and sustaining atomic-scale surface roughness, by H-induced silicon etching, is a prerequisite for H absorption and determines the $T_s$ windows. Issues on the H(g) absorption to be further clarified are: (1) the role of the detailed atomic surface structure, together with other experimental conditions, (2) the particular physical lattice sites occupied by, and (3) the chemical nature of, absorbed H(g) atoms. This work has investigated and compared the thermal H(g) atom absorptivity of Si(100), Si(111) and Si(110) samples in detail by using the temperature programmed desorption mass spectrometry (TPD-MS). Due to the differences in the atomic structures of, and in the facility of creating atom-scale etch pits on, Si(100), (100) and (110) surfaces, the H-absorption efficiency was found to be larger in the order of Si(100) > Si(111) > Si(110) with a relative ratio of 1 : 0.22 : 0.045. This intriguing result was interpreted in terms of the atomic-scale surface roughening and kinetic competition among H(g) adsorption, H(a)-by-H(g) abstraction, $SiH_3(a)$-by-H(g) etching, and H(g) penetraion into the crystalline silicon bulk.

  • PDF

Studies on the Releasing Effect of Cerium in Calcium Analysis by Atomic Absorption Spectrometry (원자흡수 분광법에 의한 칼슘분석에서 세륨의 해방효과에 관한 연구)

  • Kee Chae Park;Hee Seon Choi;Soo Han Kwon
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.129-136
    • /
    • 1985
  • In the atomic absorption spectrometry using an air-acetylene flame, the interferences of Zr, Sn, Al, Sb, $SO_4^{2-},\;VO_3^-,\;and\;SiO_3^{2-}$, on the calcium absorption and the repression of this interference by the addition of cerium have been studied. The interference by Zr, Sn, Al, Sb, $SO_4^{2-},\;VO_3^-,\;and\;SiO_3^{2-}$ existed as the same concentration as calciurn ($3.0 {\times} 10^{-4}$M) in the sample solution are completely released by the addition of cerium twice as much as interfering cation. The interferences by the mixed interfering cations (Zr, Sn, Al and Sb) and by the mixed interfering anions ($SO_4^{2-},\;VO_3^-,\;and\;SiO_3^{2-}$) are larger than by each interfering cation and anion, and the releasing effect by cerium ($1.5 {\times} 10^{-2}$M) is effective up to some degree of the concentration of mixed interfering cations and of mixed interfering anions. The releasing effect by cerium to the mixed solution of interfering cations and anions is applicable to quite wide range of concentration.

  • PDF

Surface Reactions of Atomic Hydrogen with Ge(100) in Comparison with Si(100)

  • Jo, Sam Keun
    • Applied Science and Convergence Technology
    • /
    • v.26 no.6
    • /
    • pp.174-178
    • /
    • 2017
  • The reactions of thermal hydrogen atoms H(g) with the Ge(100) surface were examined with temperature-programmed desorption (TPD) mass spectrometry. Concomitant $H_2$ and $CH_4$ TPD spectra taken from the H(g)-irradiated Ge(100) surface were distinctly different for low and high H(g) doses/substrate temperatures. Reactions suggested by our data are: (1) adsorbed mono(${\beta}_1$)-/di-hydride(${\beta}_2$)-H(a) formation; (2) H(a)-by-H(g) abstraction; (3) $GeH_3$(a)-by-H(g) abstraction (Ge etching); and (4) hydrogenated amorphous germanium a-Ge:H formation. While all these reactions occur, albeit at higher temperatures, also on Si(100), H(g) absorption by Ge(100) was not detected. This is in contrast to Si(100) which absorbed H(g) readily once the surface roughened on the atomic scale. While this result is rather against expectation from its weaker and longer Ge-Ge bond as well as a larger lattice constant, we attribute the absence of direct H(g) absorption to insufficient atomic-scale surface roughening and to highly efficient subsurface hydrogenation at moderate (>300 K) and low (${\leq}300K$) temperatures, respectively.

Studies on Components of Sarcodon aspratus(II) (능이의 성분(成分)에 관한 연구(硏究)(제(第)2보(報)))

  • Park, Wan-Hee
    • The Korean Journal of Mycology
    • /
    • v.11 no.4
    • /
    • pp.159-162
    • /
    • 1983
  • The dried carpophores of Sarcodon aspratus were examined for mineral elements and a protein-polysacccharide. Calcium, iron, zinc, magnesium, manganese, copper, lead, cadmium and mercury were detected in that order of contents by atomic absorption spectrometry and automatic mercury analysis. The protein-polysaccharide fraction extracted from the carpophore was found to contain 31.5% protein and 52.8% polysaccharide. The fraction showed no antitumor activity against sarcoma 180 implanted in mice.

  • PDF

The Application of Activated Alumina for the Selective Analysis of Cr(III) and Cr(VI) (활성 알루미나를 이용한 크롬 3가 및 6가의 분리.분석)

  • Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.544-547
    • /
    • 2000
  • By using surface modified activated alumina with AI(III) and flame atomic absorption spectrometry, a rapid and convenient method for the selective analysis of chromium (III) and chromium (VI) in water has been developed. This technique appears to work accurately under optimum pH range from 3 to 5.

  • PDF

Chemical Compositions and Pyrolysis Characteristics of Oil Shales Distributed in Korea

  • Yang, Moon Yul;Yang, Myoung Kee;Lee, Sang Hak;Wakita, Hisanobu
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.487-492
    • /
    • 1995
  • The chemical compositions and pyrolysis characteristics of oil shales and source rocks distributed in the southwestern and southeastern parts of the Korean peninsular have been investigated. In order to compare the results of Korean samples with those of shales giving high oil yields, two Colorado oil shale samples and one Paris source rock samples were also investigated. Chemical compositions of the samples were analysed by means of gravimetry, CHN analysis, X-ray diffraction method, inductively coupled plasma atomic emission spectrometry and atomic absorption spectrometry. A custom made pyrolyser and a Rock-Eval system were used for the pyrolysis studies. Pyrolyses of the samples were carried out by means of a temperature controlling device to $600^{\circ}C$ at a heating rate of $5^{\circ}C/min$ with a helium flow rate of $1200m{\ell}/min$. The results of pyrolysis study indicated that Colorado shale samples belong to type I and all the other samples belong to type II.

  • PDF

Analysis of Copper, Zinc in Serum Using ICP-MS & AAS (ICP-MS와 AAS를 이용한 체내 혈청 Cu, Zn 분석에 관한 연구)

  • Lee, Yea-Jin;Kim, Dong-Yub;Lee, Go-Eun;Jo, Young-Suk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The exposure of human beings to toxic trace metals (Cu, Zn) continues to be an important public health issue and concern. This study was conducted to assess the exposure to trace metals (Cu, Zn) in the general Korean population by inductively coupled plasma mass spectrometry (ICP-MS) and Atomic absorption spectrometry (AAS). Serum samples were obtained from 40 healthy volunteers. Specimens were collected in special container and we applied sample processing to minimize contamination. We used ICP-MS and AAS to analyze simultaneously the concentration of metals including copper, zinc. Distribution of trace metal levels in the general healthy population showed lower values. The results in this study can provide background data for clinical studies associated with trace metal exposure in the korean population.

  • PDF