• Title/Summary/Keyword: Atmospheric temperature and humidity

Search Result 282, Processing Time 0.027 seconds

An Analysis of Climatic Elements around the Pohang area (포항지역의 기후요소별 분석)

  • Jung, Woo-Sik;Kim, Hyun-Goo;Lee, Soon-Hwan;Lee, Hwa-Woon
    • Journal of the Korean earth science society
    • /
    • v.24 no.5
    • /
    • pp.449-455
    • /
    • 2003
  • Climatic elements were investigated in order to understand the atmospheric environment around the Pohang area and for use as basic information in prediction. In this analysis, we could find that the annual mean temperature, relative humidity, and precipitation are 14.39$^{\circ}C$, 63.3%, and 1.178mm, respectively. The prevailing wind direction was southwestern, and the mean wind speed is 2.7m/s. The amount of cloud was abundant during the summer because of the Jang-ma phenomenon and convective clouds induced by terrain effect. The annual mean duration of sunshine represented about 2,221 hours.

Synoptic Meteorological Classification and Analysis of Precipitation Characteristics in Gimhae Region Using 2DVD and Parsivel (2DVD와 Parsivel 이용한 김해지역 강수사례일의 종관기상학적 분류 및 강수 특성 분석)

  • Cheon, Eun-Ji;Park, Jong-Kil;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.26 no.3
    • /
    • pp.289-302
    • /
    • 2017
  • During the research period, error analysis of the amount of daily precipitation was performed with data obtained from 2DVD, Parsivel, and AWS, and from the results, 79 days were selected as research days. According to the results of a synoptic meteorological analysis, these days were classified into 'LP type, CF type, HE type, and TY type'. The dates showing the maximum daily precipitation amount and precipitation intensity were 'HE type and CF type', which were found to be attributed to atmospheric instability causing strong ascending flow, and leading to strong precipitation events. Of the 79 days, most days were found to be of the LP type. On July 27, 2011 the daily precipitation amount in the Korean Peninsula reached over 80 mm (HE type). The leading edge of the Northern Pacific high pressure was located over the Korean Peninsula with unstable atmospheric conditions and inflow of air with high temperature and high humidity caused ascending flow, 120 mm/h with an average precipitation intensity of over 9.57 mm/h. Considering these characteristics, precipitation in these sample dates could be classified into the convective rain type. The results of a precipitation scale distribution analysis showed that most precipitation were between 0.4-5.0 mm, and 'Rain' size precipitation was observed in most areas. On July 9, 2011, the daily precipitation amount was recorded to be over 80 mm (CF type) at the rainy season front (Jangma front) spreading across the middle Korean Peninsular. Inflow of air with high temperature and high humidity created unstable atmospheric conditions under which strong ascending air currents formed and led to convective rain type precipitation.

Relationship Analysis between Relative Humidity and Explosion Pressure of Hydrogen-Air and Acetylene-Air Mixtures in Flameproof Enclosure (내압방폭구조에서 수소-공기와 아세틸렌-공기 혼합가스의 폭발압력과 상대습도의 상관관계 분석)

  • Yong-Tae, Kim;Kihyo, Jung
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.4
    • /
    • pp.101-107
    • /
    • 2022
  • To test a flameproof enclosure for the safety certificate, a reference pressure of explosion needs to be determined. However, the explosion pressure may be changed according to relative humidity of explosive gases. Therefore, the guideline on relative humidity should be recommended for measuring the explosion pressure for accurate and reproducible testings. This study examined the relationship of explosion pressure with relative humidity of hydrogen (31 vol %)-air and acetylene (14 vol %)-air mixture gases. The explosion pressures were measured by increasing the relative humidity of the gases by 10 % from dry state to 80 % in a cylindrical explosion enclosure of 2.3 L. on ambient temperature and atmospheric pressure (1 atm). The maximum explosive pressures were remained almost constant until the relative humidity reached 10 % for the hydrogen-air mixture and 20 % for the acetylene-air mixture. However, the maximum explosive pressures linearly decreased as the relative humidity increased. Based on the results of the study, it would be recommended to use 10 % relative humidity for the hydrogen-air mixture and 20 % for the acetylene-air mixture as the critical value in testing a flameproof enclosure.

Measurement and Analysis of Visibility lmpairment during June, 1994 in Seoul (1994년 6월 서울지역 시정장애의 측정 및 분석)

  • 백남준;이종훈;김용표;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.407-419
    • /
    • 1996
  • Characteristics of visual air quality in Seoul have been investigated between June 13 and 21, 1994. Optical properties (extinction coefficient and particle scattering coefficient), meteorological parameters (relative humidity, temperature, wind speed, wind direction, and cloud cover), particle characteristics (mass size distribution, components) were measured and analyzed. During measurement periods, northwest wind with less than 2m/sec of wind speed deteriorates visibility. Effects of relative humidity are though to be not a direct factor which influence to visibility through the size change due to hygroscopic species in aerosol. During the smoggy period both the aerosol mass concentration and fine particle fraction of the size distribution are increased compared to the clear period. Sulfate, organic carbon, and elemental carbon in aerosol are the major species in determining the occurrence and severity of a smog in Seoul.

  • PDF

The Characteristics of the Treatment of Pollutants ($SO_2$, NOx) Using Surface Discharge Induced Plasma Chemical Process (SPCP를 이용한 오염물질 ($SO_2$, NOx) 처리 특성)

  • 봉춘근;부문자
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.333-342
    • /
    • 1998
  • Plasma process has great possibilities to remove SOx, NOx simultaneously with high treatment efficiency and is expected to be suitable for small or middle plants. It was accomplished to evaluate SO2, NOx control possibility and achieve basic data to control pollutants by use of Surface Discharge Induced Plasma Chemical Process (SPCP) in this study. O3 generation characteristics by discharge of a plate was proportional to O2 concentration and power consumption and inversely proportional to temperature and humidity, In case of dry air, NOx was highly generated by N2 and O2 in air during the plasma discharge process but it was decreased considerably as H2O was added. SO2 removal efficiency was very high, and removal rate was 170,350 mEA at 30,50 watt respectively in flue gas which is usually contain HIO. NOx removal efficiency was about 57% at 40 watt power consumption with 7.5% humidity. It is estimated that H2O has an important role in reaction mechanism with pollutants according to plasma discharge.

  • PDF

The Characteristics of Suspended Particulate Matters in Downtown Seoul During Winter Period (겨울철 서울도심의 대기중 부유분진의 특성)

  • Kim, Shin-Do;Kim, Jong-Ho;Lee, Jeong-Joo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.2
    • /
    • pp.105-111
    • /
    • 1992
  • The characteristics of suspended particulate matters(dust) in Seoul had been studied. The effects of various environmental factors, such as passengers, motor vehicles, wind velocity, wind direction, temperature and humidity were examined during the study period. It was shown that the dust emission occurred through the heating was the major source, and the contribution of passengers and motor vehicles was relatively negligible during the night. It was also revealed that the number concentration between $0.5{\mu}m$ and $2.0{\mu}m$ was increased due to the attachment among the dusts and mists by the increased humidity during the night. Considering the fact that the particles larger than $2{\mu}m$ take the most part of weight concentration, it was suggested that the PM-10 method which considered respirable particle as a weighting factor should be adapted in the evaluation air quality.

  • PDF

Modelling of evaporation from free water surface

  • Song, Wei-Kang;Chen, Yibo
    • Geomechanics and Engineering
    • /
    • v.21 no.3
    • /
    • pp.237-245
    • /
    • 2020
  • The process of evaporation from free water surface was simulated in a large scale environmental chamber under various controlled atmospheric conditions and also was modelled by a new mass transfer model. Six evaporation tests were conducted with increasing wind speed and air temperature in the environmental chamber, and hence the effect of atmosphere parameters on the evaporation process and the corresponding response of water were investigated. Furthermore, based on the experiment results, seven general types of mass transfer models were evaluated firstly, and then a new model consisted of wind speed function and air relative humidity function was proposed and validated. The results show that the free water evaporation is mainly affected by the atmospheric parameters and the evaporation rate increases with the increasing air temperature and wind speed. Both the air and soil temperatures are affected by the energy transformation during water evaporation. The new model can satisfactorily describe the evaporation process from free water surface under different atmospheric conditions.

Effect of Relative Humidity on Explosion Pressure for Gas Group IIB, IIA, and I (상대습도에 따른 가스 그룹 IIB, IIA, I의 폭발압력 분석)

  • Yongtae Kim;Kihyo Jung
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.51-58
    • /
    • 2023
  • Determination of explosion reference pressure is important in designing and testing flameproof enclosures (Ex d). Although relative humidity affects to explosion pressure, its effect is not well investigated for the gas group IIB, IIA, and I. This study tested explosion pressure for Ethylene (8 vol.%), Propane (4.6 vol.%), and Methane (9.8 vol.%), which are the representative gas of the gas group IIB, IIA, and I, at ambient temperature and atmospheric pressure (1 atm) under different relative humidity (0% ~ 80%). Ethylene- and Propane-air mixed gases generally tended to decrease as the relative humidity increased; however, explosion pressure was largely dropped at 20% of relative humidity compared to 0% and 10% of relative humidity. On the other hand, Methane-air mixture gas showed similar pressures at 0% and 10% of relative humidity; but no explosion occurred at more than 20%. The results of this study can be used in setting a testing protocol of explosion reference pressure for designing and testing a flameproof enclosure.

Seasonal Variation of Nitrate in the Greater Seoul Area Using a Photochemical Box Model and a Gas/Aerosol Equilibrium Model (광화학 상자모델과 기체/입자 평형모델을 이용한 서울ㆍ수도권의 계절별 질산염 농도 변화)

  • Lee S.;Ghim Y. S;Kim Y. P;Kim J. Y
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.729-738
    • /
    • 2004
  • Seasonal variation of major inorganic ions in the greater Seoul area was estimated using a photochemical box model and a gas/aerosol equilibrium model with emphasis on semi -volatile nitrate. Pollutant emission was determined by season by comparing the predicted concentration with the measurement one obtained for a year from the late 1996. The results showed that particulate nitrate was the highest in summer but about 40% of total nitrate was present in the gas phase. This was due to volatilization at high temperature since ammonia was sufficient to neutralize all nitrate regardless of season. As relative humidity in summer was higher than the deliquescence point, particulate ion concentration with water was two times higher than that in other season. So called ‘NOx disbenefit’ indicating increase in particulate ion concentration with decrease in NOx emission was evident especially in winter.

Optical Properties of Atmospheric Aerosol in Kwangju Measured with a Temperature and Humidity Controlled Nephelometer (온도 및 습도의 변화에 따른 광주 도심지역 에어로졸의 광학적 특성 연구)

  • 오승진;김경원;박성훈;김영준
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.57-58
    • /
    • 2000
  • 대기 중에 분포되어 있는 다양한 크기와 종류의 에어로졸은 산업의 발전과 급속한 인구의 증가로 인해 가중되고 있으며, 특히 이로 인해 도심지역의 시정감쇄에 큰 영향을 미치고 있다. 특히 도시지역의 대기 중 미세 입자(PM2.5)의 시정감쇄에 대한 영향은 거대입자에 비하여 지배적인 것으로 나타난다. 그 과정에서 대기중 입자의 광학적인 성질 뿐 만 아니라 기상적인 변동 특히 온도와 습도에 의한 시정의 변화는 큰 영향을 받고 있다. (중략)

  • PDF