• 제목/요약/키워드: Atmospheric gas

검색결과 1,310건 처리시간 0.029초

BAF에서 분위기 가스의 수소 성분이 생산성에 미치는 영향 (Effect of Productivity on the Hydrogen Content of Atmospheric gas in the BAF)

  • 김순경;전언찬;김문경
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.560-564
    • /
    • 1996
  • In recently, annealing process of cold rolled sheet tend to change to continuous annealing process for improving qualify, saving yield. In the meantime as demand for various kind and small lot of products has been increasing, batch annealing has been appreciated for its small restriction for the operation. So, we tested on the effect for a hydrogen contents of atmospheric gas at annealing furnace. As a result of several investigation. We confirmed for the following characteristics ; improved productivity, uniform heating, improved surface quality, saving energy. Therefore, the use of hydrogen instead of nitrogen as the protective gas, combined with high convection in batch annealing furnaces, has shown that considerable increases in furnace output and material quality are attainable. Owing to the low density, high diffusion and reducing character of hydrogen, a better transfer resulting in uniform material temperatures and improved coil surfaces can be achieved.

  • PDF

Analysis of Factors Impacting Atmospheric Pressure Plasma Polishing

  • Zhang, Ju-Fan;Wang, Bo;Dong, Shen
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권2호
    • /
    • pp.39-43
    • /
    • 2008
  • Atmospheric pressure plasma polishing (APPP) is a noncontact precision machining technology that uses low temperature plasma chemical reactions to perform atom-scale material removal. APPP is a complicated process, which is affected by many factors. Through a preliminary theoretical analysis and simulation, we confirmed that some of the key factors are the radio frequency (RF) power, the working distance, and the gas ratio. We studied the influence of the RF power and gas ratio on the removal rate using atomic emission spectroscopy, and determined the removal profiles in actual operation using a commercial form talysurf. The experimental results agreed closely with the theoretical simulations and confirmed the effect of the working distance. Finally, we determined the element compositions of the machined surfaces under different gas ratios using X-ray photoelectron spectroscopy to study the influence of the gas ratio in more detail. We achieved a surface roughness of Ra 0.6 nm on silicon wafers with a peak removal rate of approximately 32 $mm^{3}$/min.

單一 排出源大氣汚染 短期모델에 관한 硏究 -Tracer Gas에 의한 擴散實驗- (On the Short Term Air Pollution Dispersion Model for the Single Souce -Diffusion Experiment With Tracer Gas-)

  • 李鍾範;姜寅求
    • 한국대기환경학회지
    • /
    • 제5권2호
    • /
    • pp.84-96
    • /
    • 1989
  • To evaluate the short term air pollution dispersion model, the diffusion experiment was conducted on the flat terrain near Chuncheon. Sulfur hexafluoride $(SF_6)$ gas was used to determine the horizontal spread of plume $(\sigmay)$ for calculated by CRSTER model. Results show that CRSTER model underestimates $\sigma$y because averaging time adjustment is not applied to calculate the $\sigma$y. The scheme that can estimate the atmospheric stability more accurate than Turner method, was presented.

  • PDF

Optimization of Atmospheric Cold Plasma Treatment with Different Gases for Reduction of Escherichia coli in Wheat Flour

  • Lee, Jeongmin;Park, Seul-Ki;Korber, Darren;Baik, Oon-Doo
    • Journal of Microbiology and Biotechnology
    • /
    • 제32권6호
    • /
    • pp.768-775
    • /
    • 2022
  • In this study we aimed to derive the response surface models for Escherichia coli reduction in wheat flour using atmospheric cold plasma (ACP) with three types of gas. The jet-type atmospheric cold plasma wand system was used with a 30 W power supply, and three gases (argon, air, and nitrogen) were applied as the treatment gas. The operating parameters for process optimization considered were wheat flour mass (g), treatment time (min), and gas flow rate (L/min). The wheat flour samples were artificially contaminated with E. coli at a concentration of 9.25 ± 0.74 log CFU/g. ACP treatments with argon, air, and nitrogen resulted in 2.66, 4.21, and 5.55 log CFU/g reduction of E. coli, respectively, in wheat flour under optimized conditions. The optimized conditions to reduce E. coli were 0.5 g of the flour mass, 15 min of treatment time, and 0.20 L/min of nitrogen gas flow rate, and the predicted highest reduction level from modeling was 5.63 log CFU/g.

HNx 분위기가스중에서 BAF소둔시 코일의 온도변화에 관한 연구 (A Study on Temperature Variation of Coil on BAF Annealing in HNx Atmospheric Gas)

  • 전언찬;김순경
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1227-1234
    • /
    • 1994
  • A cold spot temperature control system for the batch annealing furnace has been established in order to reduce energy consumption which is essential to improve productivity and stabilize the properties of products. A relationship between annealing cycle time and gas flow rate is developed and also for the variation of coil cold spot temperature with time during heating, and actual temperature measurements at mid-width of each coil during soaking. The results of the temperature variation effect on the cold rolled steel sheet batch annealing are as follows. (1) Cooling rate increasing gradually with increasing atmospheric gas flow, but heating rate is hardly increasing without atmospheric gas component change. (2) In case of short time heating, the slowest heating part is the center of B coil and in case of ling time heating, the low temperature point moves from the center of coil to inside coil. (3) The outside of top coil is the highest temperature point under heating, which becomes the lowest temperature point under cooling. (4) Soaking time determination depends on the input coil width, and soaking time for quality homogenization of 1214 mm width coil must be 2 hours longer than that of 914 mm width coil.

서울 관악산 대기 중의 $SF_6$에 관한 연구 (Atmospheric Sulfur Hexafluoride $(SF_6)$ near the Kwanak Mountain, Seoul)

  • 이정현;김경렬
    • 대기
    • /
    • 제18권3호
    • /
    • pp.225-235
    • /
    • 2008
  • Sulfur hexafluoride ($SF_6$), man-made compound, has been paid attention as a potent greenhouse gas. After Kyoto Pototcol on Climate Change in 1997, nations established the policy aimed at minimizing release of $SF_6$ to atmosphere. We have developed and operated an automatic analytical system for monitoring atmospheric $SF_6$ using gas chromatography with electron capture detector (GC-ECD) and packed separate-column. Here, we report and discuss 4-month record of atmospheric $SF_6$ concentrations monitored at Seoul National University (SNU) pilot station near the Kwanak Mountain, Seoul. Most of observed $SF_6$ concentrations were excessively high compared with Northern Hemisphere (NH) background trend obtained from National Oceanic and Atmospheric Administration (NOAA) Earth System Research Laboratory (ESRL) monitoring stations. And the observed $SF_6$ showed extremely wide variability ranging from 4.6 pptv to $1.1{\times}10^3$ pptv, which may be affected by local sources placed nearby. Simultaneous wind data with $SF_6$ measurements show that relatively high values of $SF_6$ correspond to weak wind as well as southerly. There are many engineering installations to the south of the station. The regional value of the atmospheric $SF_6$ estimated from the data selection by wind conditions is about 6.8 pptv. This value, which is similar to concentrations of urban areas, is higher than NH background concentration.

가스 누출 감지를 위한 저전력 자동 ON/OFF 밸브 시스템 개발에 관한 연구 (A Study on the Development of Low Power Automatic ON/OFF Valve System for Gas Leak Detection)

  • 최영규
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.369-374
    • /
    • 2021
  • 최근에 건설되는 아파트는 주방이 빌트인 방식으로 만들어지므로 가스 호스가 싱크대 내부에 보이지 않게 만들어지므로 가스가 누출될 경우 싱크대 내부에 축적되어 가스 폭발로 이어질 수 있는 위험한 방식이다. 본 연구에서는 가스레인지와 중간밸브 사이에 연결된 호스가 싱크대 내부에 있어 가스 누출 검사를 할 수 없는 구조로 되어 있어 압력센서를 이용하여 가스누출을 검사를 쉽게 할 수 있는 밸브 시스템 연구하였다. 압력 측정 방법은 중간밸브와 가스레인지를 연결하는 호스의 압력을 측정하여 I2C통신 방식으로 데이터를 수집·분석 할 수 있도록 진행하였다. 또한 가정에 공급되는 가스압력계산은 대기압력에 가스계량기의 입구에서 가스게이지 압력 평균값 22.46mbar를 더 한 값으로 계산된 것에 대한 대기 압력 오차에 대한 규명 및 미세한 가스 누출 감지를 할 수 있도록 밸브 시스템을 개발하였다.

A Study on the Concentration Characteristics of Atmospheric Polycyclic Aromatic Hydrocarbons (PAHs) in Chongju

  • Lee, Hak-Sung;Kang, Byung-Wook;Kwon, Dong-Hyuk;Yeo, Hyun-Gu;Chun, Man-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제19권E2호
    • /
    • pp.89-97
    • /
    • 2003
  • Ambient polycyclic aromatic hydrocarbons (PAHs) were measured during the winter and summer of 2002 in Chongju. A filter pack and polyurethane foam (PUF) system was employed to collect simultaneously the particulate and gas phase PAHs. The samples were then analyzed using a gas chromatograph equipped with mass spectrometer detectors (GC/MSD). A total of 29 samples were collected and 11 PAH species were identified. The lower molecular weight PAH compounds (3∼4 rings) dominated the total PAH mass. The higher molecular weight PAH compounds (5∼6 rings) were less abundant. The PAHs were showed to exhibit seasonal variations. The concentrations of all com-pounds were significantly higher in winter than summer. The lower molecular weight PAHs were mostly found in the gas phase whereas the heavier ones were mainly associated with particulate phase. Vehicle emissions are likely to be the primary contributor of PAHs in Chongju. This study also demonstrated that it is necessary to perform simultaneously particulate and gas phase measurements to determine the accurate concentrations of ambient PAHs.

촉매연소를 이용한 무 산소 가스 생성에 관한 연구 (A Study on the Generation of Oxygen-Free Gas Using Catalytic Combustion for Industrial Applications)

  • 정남조;강성규;송광섭;조성준;유상필;유인수
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제22회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.46-52
    • /
    • 2001
  • In this study, the generation of oxygen-free gas using catalytic combustion for industrial applications is explained ; heat treatment and copper annealing. For the experiment, Pd catalysts were determined by testing their catalytic activities over LPG in a micro-reactor. Combustion characteristics for the generation of oxygen-free atmospheric gas and the effect of flue gas upon surface oxidation were estimated form this experiment. As a result of the experimental investigation, we can state that the catalytic combustion could generate oxygen-free atmospheric gas suitable for industrial applications, but vapor produced by combustion process must be carefully considered as a new factor of surface oxidation.

  • PDF