• Title/Summary/Keyword: At-Speed test

Search Result 2,580, Processing Time 0.03 seconds

A Study on the Dynamic Characteristics on the Test Line for Korean High Speed Train (한국형 고속전철의 주행진동 특성에 관한 연구)

  • 김영국;김석원;박찬경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.555-560
    • /
    • 2003
  • Korean High Speed Train(KHST) has been tested on the high speed test line in Osung site of Korea High Speed Rail Construction Authority (KHRC). since it was developed as G7 Project Plan In 2002. This paper introduces the dynamic test devices in KHST and shows the comparison between the results of test and theoretical computing results which derive from the new model for KHST dynamic behavior. Previous computer simulation model for KHST was developed to review wether the vehicle system was satisfied with the dynamic performance requirements during the design procedure. But It should be applied the results of the parts test for suspension elements in order to compare between the results of computation and real test. Using VAMPIRE Program made by AEA Technology in UK. the new model also was modified. This paper shows that the static wheel loads calculated from new model is similar to test results. For test on high speed line, we prepared the test devices for evaluating the dynamic performances. which was consisted of the accelerometers( based on Kisler Co.) and the data aquisition systems (based on National instrument Co.), and test program coded by LabView 6i program. These lest devices and programs are flexible to extension the channels for adding sensors and connect to the ethernet network. The acceleration of car bodies, bogie frames and axle boxes were compared between the results of computation and test at 150km/. This paper shows that the results of test were high in high frequency band range but similar frequency band range. It might be considered that these differences were caused by the test which did not performed at constant speed for comparison analysis. Also. It will be able to understand the differences and make better results through a lot of tests planed in future.

  • PDF

Analysis and evalution of interior noise for Hanvit-200 train (한빛 200 열차의 실내 소음 특성 분석)

  • Lee, Chan-Woo;Kim, Jae-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1766-1769
    • /
    • 2008
  • INnterior noise characteristic of Korean tilting train(Hanvit 200) under the field test conditions is analyzed in this paper. The test railroad track was selected from Seodaejon to Songjeongri in Honam line. $4^{th}$ and $5^{th}$ car are decided to measure interior noise level among a train of six cars. The test subject open field executed from test sections. The speed of test trains when from existing operation speed and speed up 20% of existing speed. On open field at the time of operation speed of Hanvit 200 trains from below 160km/h interior noise level at $68dBA{\sim}70dBA$.

  • PDF

Dependency on the Forming speed at the warm forming of magnesium sheet (마그네슘 판재 온간 딮드로잉성에서의 속도의존성)

  • Park, H.Y.;Lee, H.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.246-249
    • /
    • 2007
  • This study is concerned with deep drawability of magnesium sheets(AZ31B) at the warm conditions. Especially the dependency on forming speed has been investigated at the temperature of $200^{\circ}C$ and $300^{\circ}C$. Deep drawing test has been carried out at the temperature of $200^{\circ}C$ and $300^{\circ}C$. The die and blank holder are kept at test temperature by local heating and the punch is kept at room temperature by cooling technique. The magnesium sheets called AZ31B with the thickness of 0.5mm have been applied to deep drawing of circular cup. The drawability has been estimated at the conditions of forming speed (0.1, 1, 10 mm/sec). The results of deep drawing experiments show that the drawability is better at $300^{\circ}C$. Also the deep drawability is improved at the low speed(1mm/sec).

  • PDF

The Feasibility Study of the Scenario of 400kph Maximum Speed Test in HEMU (High-speed Electric Multiple Unit) System (400km/h급 전차선로 시스템의 시범적용 구간선정 연구)

  • Ryoo, Hyang-Bok;Jang, Sa-Sool;Park, Jae-Woong;Lee, Hae-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.761-767
    • /
    • 2011
  • Since the "Low Carbon, Green Growth" as a social requirements is attracted public attention, the policies and investments of the railway which have been less estimated than road is re-considered. Since the starting the commercial service (2004. April), the KTX have been operated successfully while transport passengers over 100million for years. And also the project for development of KHST (Korea High Speed Train ; G7) had been accomplished with a good result, the first trainset of KTX-II which base on G7 project was manufactured and testing now. On the other hand, the world's technology of the high speed train is more faster, and changing to a distributed traction system. To catch up the world's leading technology, the HEMU(High-speed Electric Multiple Unit) project will secure new technology and aims to promote the technology of domestic high-speed train. The authors indicates the result of detail review such as a curve, slope of the track and electrical dead section of the catenary to test at 400kph and also the performance simulation of the developed rolling stock in this paper. As the result, the authors devise the test scenario to perform a maximum speed test (stability at max. speed, acceleration & deceleration etc) with the restricted conditions such as track length, track available time etc by considering above result.

  • PDF

The Feasibility study of the scenario for 400kph maximum speed test in HEMU (High-speed Electric Multiple Unit) System (분산형 고속철도 시스템의 400kph 최고속도 시험을 위한 시운전 시나리오 고찰)

  • Kang, B.M.;Jeong, S.H.;An, H.K.;Cho, B.C.;Moon, J.S.
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.429-433
    • /
    • 2009
  • Since the "Low Carbon, Green Growth" as a social requirements is attracted public attention, the policies and investments of the railway which have been less estimated than road is re-considered. Since the starting the commercial service (2004. April), the KTX have been operated successfully while transport passengers over 100million for years. And also the project for development of KHST (Korea High Speed Train ; G7) had been accomplished with a good result, the first trainset of KTX-II which base on G7 project was manufactured and testing now. On the other hand, the world's technology of the high speed train is more faster, and changing to a distributed traction system. To catch up the world's leading technology, the HEMU(High-speed Electric Multiple Unit) project will secure new technology and aims to promote the technology of domestic high-speed train. The authors indicates the result of detail review such as a curve, slope of the track and electrical dead section of the catenary to test at 400kph and also the performance simulation of the developed rolling stock in this paper. As the result, the authors devise the test scenario to perform a maximum speed test (stability at max. speed, acceleration & deceleration etc) with the restricted conditions such as track length, track available time etc by considering above result.

  • PDF

The Design and Manufacture of Pantograph for Korean High Speed Train (한국형 고속전철용 판토그라프의 설계 및 제작)

  • 김휘준;박수홍;정경렬;배정찬
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1223-1228
    • /
    • 2001
  • We have been developing the pantograph for Korean High Speed Train for the last five years. To fulfil the following requirements at designed speed of 350km/h : 1) contact loss less than 1 %, 2) aerodynamic noise less than 91dB, 3) average uplift force less than 200N, the pantograph has been modified two times since the first prototype pantograph was manufactured, By means of the following up characteristic test, low speed wind tunnel test, and high speed wind tunnel test for the prototype pantographs, we found that the aerodynamic uplift force did not exceed l60N at speed up to 350km/h and the aerodynamic noise was less than 88dB, that the following up characteristics of the prototype pantograph was excellent.

  • PDF

IEEE 1500 Wrapper Design Technique for Pre/Post Bond Testing of TSV based 3D IC (TSV 기반 3D IC Pre/Post Bond 테스트를 위한 IEEE 1500 래퍼 설계기술)

  • Oh, Jungsub;Jung, Jihun;Park, Sungju
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.131-136
    • /
    • 2013
  • TSV based 3D ICs have been widely developed with new problems at die and IC levels. It is imperative to test at post-bond as well as pre-bond to achieve high reliability and yield. This paper introduces a new testable design technique which not only test microscopic defects at TSV input/output contact at a die but also test interconnect defects at a stacked IC. IEEE 1500 wrapper cells are augmented and through at-speed tests for pre-bond die and post-bond IC, known-good-die and defect free 3D IC can be massively manufactured+.

Field Adaptability Test for the Full Load Rejection of Nuclear Turbine Speed Controllers using Dynamic Simulator

  • Choi, In-Kyu;Kim, Jong-An;Woo, Joo-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.67-74
    • /
    • 2009
  • This paper describes the speed control functions of the typical steam turbine speed controllers and the test results of generator load rejection simulations. The goal of the test is to verify the speed controller's ability to limit the steam turbine's peak speed within a predetermined level in the event of generator load loss. During normal operations, the balance between the driving force of the steam turbine and the braking force of the generator load is maintained and the speed of the turbine-generator is constant. Upon the generator's load loss, in other word, the load rejection, the turbine speed would rapidly increase up to the peak speed at a fast acceleration rate. It is required that the speed controller has the ability to limit the peak speed below the overspeed trip point, which is typically 110[%] of rated speed. If an actual load rejection occurs, a substantial amount of stresses will be applied to the turbine as well as other equipments, In order to avoid this unwanted situation, not an actual test but the other method is necessary. We are currently developing the turbine control system for another nuclear power plant and have plan to do the simulation suggested in this paper.

Effects of Unilateral Step Treadmill Training on the Gait Speed and Recovery of Gait Symmetry in Patients with Chronic Stroke (편측성 걸음걸이 트레드밀 훈련이 만성 뇌졸중 환자의 보행 속도와 대칭성 회복에 미치는 효과)

  • Lee, Ji-Yeon;Chon, Seung-Chul
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.4
    • /
    • pp.145-151
    • /
    • 2022
  • Purpose : Stroke patients exhibit abnormal walking patterns such as slow walking speed and asymmetrical walking values. The recovery of symmetrical walking in the stance phase using a treadmill means improvements in walking speed and asymmetrical walking. The purpose of this research was to investigate the effect of unilateral step treadmill training (USTT) on gait speed and the recovery of symmetrical walking in chronic stroke patients. Methods : Fifteen patients (11 men and 4 women) with chronic stroke participated in this study. The 10-meter walk test (10MWT) and GAITRite system were used to determine the intervention-related changes in gait speed and symmetrical walking values such as non-paretic step length (NSL), non-paretic step time (NST), paretic single-support time (PSST), step length asymmetry (SLA), and step time asymmetry (STA) after USTT. All participants completed USTT and underwent measurements at 3 different times: at pretest, posttest, and the follow-up test. Repeated-measures analysis of variance was used to compare walking speed and asymmetrical walking values. The statistical significance level was set at p<.05. Results : Walking speed by 10MWT (p<.05) showed significant improvements after USTT as follows: at pretest and posttest (p<.05), posttest and follow-up test (p<.05), and pretest and follow-up test (p<.05). Recovery of symmetrical walking patterns such as NSL (p<.05), NST (p<.05), and SLA (p<.05) were observed after USTT. However, no significant improvements were found in PSST (p>.05) and STA (p>.05) in symmetrical gait. Conclusion : This study suggests that USTT may have a positive effect on walking speed and symmetrical walking patterns in chronic stroke patients. Thus, this study contributes to the existing knowledge about the usefulness of USTT for the effective management of patients with chronic stroke. Further studies are needed to generalize these findings.

High-speed Performance of Single Flux Quantum Circuits Test Probe (단자속 양자 회로 측정용 고속 프로브의 성능 시험)

  • 김상문;최종현;김영환;강준희;윤기현;최인훈
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.74-79
    • /
    • 2002
  • High-speed probe made to test single flux quantum(SFQ) circuits was comprised of semi-rigid coaxial cables and microstrip lines. The impedance was set at 50 $\Omega$to carry high-speed signals without much loss. To do performance test of high-speed probe, we have attempted to fabricate a test chip which has a coplanar waveguide(CPW) structure. Electromagnetic simulation was done to optimize the dimension of CPW so that the CPW structure has an impedance of 50$\Omega$, matching in impedance with the probe. We also used the simulation to investigate the effect of the width of signal line and the gap between signal line and ground plane to the characteristics of CPW structure. We fabricated the CPW structure with a gold film deposited on Si wafer whose resistivity was above $1.5\times$10$_4$$\Omega$.cm. The magnitudes of S/sub 21/ of CPW at 6 ㎓ in simulations and in the actual measurements done with a network analyzer were: -0.1 ㏈ and -0.33 ㏈ (type A),-0.2 ㏈ and -0.48 ㏈ (type B), respectively. Using the test chip, we have successfully tested the performance of high-speed probe made for SFQ circuits. The probe showed the good performance overthe bandwidth of 10 ㎓.

  • PDF