• Title/Summary/Keyword: Aspect Ratio Effect

Search Result 757, Processing Time 0.029 seconds

Free Convection due to Vertical Isothermal Wires Immersed in Water near its Density Extremum (최대밀도점 부근의 물 속에 잠겨있는 수직 등온 강선에 의한 자연대류)

  • Eom, Y.K.;Riu, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.338-350
    • /
    • 1996
  • A numerical analysis is carried out to study the two-dimensional steady state natural convection from vertical wires immersed in cold pure water. The surface of the wire is $0^{\circ}C$ unifrom temperature. Results of the analysis are presented for free stream temperature from $0^{\circ}C$ to $25^{\circ}C$ and the aspect ratio N from $5.26{\times}10^{-3}$ to $1.0{\times}10^{-3}$. The effects of the density extremum and aspect ratio on the flow pattern and the heat transfer characteristics are discussed As the aspect ratio N becomes larger, in the range of $1.0^{\circ}C{\leq}T_{\infty}{\leq}4.4^{\circ}C$ and $6{^{\circ}C}{\leq}T_{\infty}{\leq}17^{\circ}C$, the effect of Pr number on the heat transfer is shown to be more significant than the aspect ratio. Investigating into the effect of the density extremum on the heat transfer from wires, the new heat transfer correlations are suggested with the relation of average Nu mumber vs. modified Ra number. Here, the coefficient values C of correlations are presented as the function of density extremum parameter $R^*$. The effects of the density extremum parameter are also discussed.

  • PDF

A Numerical Study of an Effect of the Aspect Ratio on Smoke Movement in funnel Fires (터널 화재시 종횡비에 따른 연기 거동에 관한 수치해석적 연구)

  • 이성룡;김충익;유홍선
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.1-6
    • /
    • 2004
  • In this study, numerical simulations were conducted to analyze an effect of the aspect ratio on smoke movement in tunnel fires using FDS 3.0. It was confirmed an application for tunnel fires in comparison with experimental results. The results showed relatively good agreement with experimental data within 1$0^{\circ}C$. Clear height of CFD by velocity distribution was about 3% higher than that of experiment. Smoke movement was confirmed by the analysis of temperature and velocity field. Results from variation of the aspect ratio showed good agreement with experimental data. The temperature at the vicinity of the fire source became lowly with the increase of the aspect ratio. But, decrease rate of the temperature was reduced by the decrease of the heat loss to the width direction.

The Effect of Aspect Ratio on the Flow Characteristics of Elliptic Jets (종횡비에 따른 타원제트의 유동특성에 관한 실험적 연구)

  • 권영철;이상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1156-1162
    • /
    • 1992
  • The effect of aspect ratio on the flow characteristics of elliptic jets was experimentally investigated. The flow characteristics of sharp-edged elliptic nozzles with aspect ratio of 1 (round nozzle), 2 and 4 were measured by using a 3-D LDV system along the major and minor axis at X/De = 2, 3, 5, 7 and along the centerline up to X/De = 14. At each measurement point mean velocites, turbulent intensities, skewness of three orthogonal velocity components, and Reynolds shear stress were obtained. The Reynolds number based on the nozzle exit velocity and nozzle equivalent diameter(De) was about 4 * 10$^{4}$. Difference in the spreading rate along the major and minor axis was remarkable. The jet half width along the major axis decreased at first and then increased again with going downstream. But the jet width along the minor axis increased steadly. The elliptic jet of AR = 2 had two switching points within the measurement range, while that of AR = 4 had only one. (AAA) : The elliptic jet of AR = 2 showed larger velocity decay rate than that of AR = 1 and AR = 4. The effect of aspect ratio on the flow characteristics of elliptic jets was dominant in the near jet regions of X/De < 7, and the skewness and Reynolds shear stress had quite different distribution depending on the aspect ratio of the elliptic nozzle.

Effect of Aspect Ratio on the Similarity of Developing Laminar Flows in Rectangular Ducts (사각 단면 관 내부의 발달하는 층류 유동 유사성에 종횡비가 미치는 영향)

  • Lee, Gong-Hee;Baek, Jae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.4
    • /
    • pp.441-448
    • /
    • 2004
  • A numerical study was conducted to show the effect of aspect ratio on the analogy of the developing laminar flows between in orthogonally rotating straight duct and in a stationary curved duct of rectangular cross-section. In order. to clarify the similarity of two nows, dimensionless parameters (equation omitted) and Rossby Ro= $w_{m}$$\Omega$ $d_{h}$, in a rotating straight duct were used as a set corresponding to Dean number, (equation omitted), and curvature ratio, λ=R/ $d_{h}$, in a stationary curved duct. Four. different aspect ratios A=0.25, 0.5, 2 and 4 were considered. Under the condition that the magnitudes of Ro and λ were large enough to satisfy the 'asymptotic invariance property' and the aspect ratio was larger than 1, there were strong quantitative similarities between the two flows such as flow patterns, friction factors, and maximum axial velocity magnitudes fur the same values of $K_{LR}$ and $K_{LC}$ . On the other hand, as the aspect ratio decreased below 1 (A=0.25 and 0.5), the difference of the secondary flow intensity between these two flows was enhanced and therefore the analogy of two flows was not so evident as that of the larger aspect ratio (A=2 and 4). 4).nd 4).

Effects of Aspect Ratio on Local Heat/Mass Transfer in Wavy Duct (열교환기 내부 유로 종횡비 변화에 따른 국소 열/물질전달 특성 고찰)

  • Jang In Hyuk;Hwang Sang Dong;Cho Hyung Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.569-580
    • /
    • 2005
  • The present study investigates the convective heat/mass transfer characteristics in wavy ducts of a primary surface heat exchanger. The effects of duct aspect ratio and flow velocity on the heat/mass transfer are investigated. Local heat/mass transfer coefficients on the corrugated duct sidewall are determined using a naphthalene sublimation technique. The aspect ratios of the wavy duct are 7.3, 4.7 and 1.8 with the corrugation angle of $145\Omega$. The Reynolds numbers, based on the duct hydraulic diameter, vary from 300 to 3,000. The results show that at the low Re(Re $\leq$ 1000) the secondary vortices called Taylor-Gortler vortices perpendicular to the main flow direction are generated due to effect of duct curvature. By these secondary vortices, non-uniform heat/mass transfer coefficients distributions appear. As the aspect ratio decreases, the number of cells formed by secondary vortices are reduced and secondary vortices and comer vortices mix due to decreased aspect ratio at Re$\leq$1000. At Re >1000, the effects of corner vortices become stronger. The average Sh for the aspect ratio of 7.3 and 4.7 are almost same. But at the small aspect ratio of 1.8, the average Sh decreases due to decreased aspect ratio. More pumping power (pressure loss) is required for the larger aspect ratio due to the higher flow instability.

Effect of Aspect Ratio in Direct Tensile Strength of Concrete (콘크리트 직접인장강도의 세장비 효과)

  • Hong, Geon-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.246-253
    • /
    • 2003
  • Although concrete members are not normally designed to resist direct tension, the knowledge of tensile strength is of value in estimating the cracking load. In general, there are three types of test method for tensile strength ; direct tension test, flexural tension test, and splitting tension test. Though direct tensile strength represents the real tensile strength of concrete, direct tension tests are seldom carried out, mainly because it is very difficult to applicate a pure tension force. The purpose of this paper is to investigate the test methods, effect of aspect ratio, and the size effect on the direct tensile strength. Direct tension test, using bonded end plates, follows RILEM and U.S.Bureau of Reclamation. And other test methods follow ASTM provisions. Four kinds of aspect ratio and two kinds of size effect are tested. Same variables are tested by direct tension test and splitting tension test for comparison between the two test methods. Test results show that direct tensile strength of concrete is more affected by aspect ratio and size than other kinds of strength.

Noise control of a slab using the laminated composite damping system (평판 부착형 제진시스템을 이용한 구조기인 소음 저감에 관한 연구)

  • Hwang, Jae-Seung;Kim, Gwang-Young;Hong, Geon-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.403-407
    • /
    • 2009
  • It is reported that the heavy weight floor impact noise of a slab system is very sensitive to the location of microphone and impact load. In addition, it is known that the aspect raio, thickness and boundary condition of a slab also have great effect on the noise induced by impact load. However, the effect has been mainly evaluated by experimental test and numerical analysis is nearly performed to verify the effect quantitatively. In this study, the effect of the aspect ratio, thickness and boundary condition on the heavy weight floor impact noise is examined through numerical analysis for simple rectangular slab system. The results show that the thickness and boundary condition have a strong correlation with the noise of the slab, on the contrary, the aspect ratio has little relation with the noise.

  • PDF

A Numerical Analysis of the Behavior of the Free Surface in a Moving Cup (이송되는 컵 내부의 자유 표면의 거동 특성에 대한 수치해석)

  • Hong, Tae-Hyub;Chae, Hee-Moon;Kim, Chyang-Nyung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2997-3002
    • /
    • 2007
  • A manipulator is operated for the motion of mechanical hands or arms by mechanical mechanism. When a cup including liquid inside is shifted by a manipulator, it is important to know how a free surface of the liquid moves. In this study, non-dimensional parameters have been found that affect the rise of the free surface in a cup moving with constant acceleration. The non-dimensional parameters are the dimensionless time, the ratio of inertia effect to vicous effect (Reynolds number), aspect ratio of the liquid inside the cup and acceleration ratio (Froude number). Through this study, the height of the free surface rise in a cup has been predicted. Generally the maximum rise of the free surface is dependent on the Reynolds number and Froude number strongly, but on the aspect ratio weakly. But the influence of the aspect ratio on the maximum rise of the free surface in not negligible in the range 10 < Re < 100.

  • PDF

Detailed Measurement of Heat/Mass Transfer in a Rotating Two-Pass Duct (II) - Effects of Duct Aspect Ratio - (이차 냉각 유로를 가진 회전덕트에서 열/물질전달 특성 (II) - 덕트 종횡비에 따른 영향 -)

  • Kim Kyung Min;Kim Yun Young;Rhee Dong Ho;Cho Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.921-928
    • /
    • 2004
  • Measurements of local heat/mass transfer coefficients in rotating two-pass ducts are presented. Ducts of three different aspect ratios (W/H), 0.5, 1.0 and 2.0, are employed with a fixed hydraulic diameter ($D_h$) of 26.7 nm. $90^{\circ}$-rib turbulators are attached on the leading and trailing walls symmetrically. The rib height-to-hydraulic diameter ratio ($e/D_h$) is 0.056, and the rib pitch-to-rib height ratio (p/e) is 10. The experimental conditions are the same as those of the previous part of the study. As the rib height-to-duct height ratio (e/H) increases, the core flow is more disturbed and accelerated in the midsections of ribs. Therefore, the obtained data show higher heat/mass transfer in the higher aspect ratio duct. Dean vortices also augment heat/mass transfer in the turn and in the upstream region of the second pass. However, the effect becomes less significant for the higher aspect ratio because the surface area increases in the present geometric condition. The effect of rotation produces heat/mass transfer discrepancy.

Aspect Ratio Effect of the Natural Convection in Horizontal Enclosure with an Array of Square

  • Lee J.R.;Ha M.Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.286-288
    • /
    • 2003
  • The physical model considered here is a horizontal layer of fluid heated below and cooled above with a periodic array of evenly spaced square cylinders placed at the center of the layer, whose aspect ratio here varies from unity to six. Periodic boundary condition is employed along the horizontal direction to allow for lateral freedom for the convection cells. Two-dimensional solution for unsteady natural convection is obtained using an accurate and efficient Chebyshev spectral multi-domain methodology for a given Rayleigh numbers of $10^6$

  • PDF