• 제목/요약/키워드: Asbestos concentration

검색결과 67건 처리시간 0.029초

중량당 섬유수가 다른 국내산 석면이 폐 기능과 폐 조직에 미치는 영향 평가 (Effect of Fiber Number Per Mass Concentration in Korean Produced Asbestos on Lung Function and Pathology)

  • 정용현;한정희;강민구;김종규;양정선
    • 한국산업보건학회지
    • /
    • 제22권4호
    • /
    • pp.301-308
    • /
    • 2012
  • Objectives: To evaluate the pulmonary toxicity of 2 Korea asbestos(chrysotile, anthophyllite), Sprague-Dawely rats were exposed to 2 mg domestic asbestos by intratracheal instillation(IT). Methods: Lung function of rats was analyzed by pressure transducer(MAX1320, Buxco Electronics, USA). The effects of 2 mg asbestos(chrysotile ; $8,814,244{\times}10^{6}$ fibers/mg, average diameter 0.08 ${\mu}m$, average length 4.39 ${\mu}m$, anthophyllite ; $5,182{\times}10^{6}$ fibers/mg, average diameter 0.95 ${\mu}m$, average length 7.29 ${\mu}m$) on pulmonary function and pathological changes were evaluated at after a single IT. Lung function and histopathological evaluation were assessed in 5 animals from each group at each time point. Results: Due to differences in fiber numbers, chrysotile induce marked lung pathology and lung function change than anthophyllite at the same mass dose. Chrysotile showed notable thickening of interstitial areas surrounding the alveolar ducts and terminal bronchioles. Conclusions: On a mass dose basis, chrysotile that have 1,700 times numbers of fibers per unit weight than anthophyllite produced a greater persistent lung injury than anthophllite for at least 4 weeks after exposure.

토양 중 백석면 표준물질 개발에 관한 연구 (A study on development of CRM chrysotile in soil)

  • 최윤호;권예빈;이진욱;김남준;정민종;황범구;이재형;선일식;김박길
    • 분석과학
    • /
    • 제26권1호
    • /
    • pp.91-98
    • /
    • 2013
  • 세계적으로 석면에 관한 다양한 연구사례가 발표되고 있는 가운데, 최근 미국을 비롯해 국내 또한 NOA (Naturally Occurring Asbestos)에 대한 관심으로 석면분포 광산 및 주변지역의 지질도 작성, 광산복원, 유해성 평가 등을 실시하고 있다. 본 연구에서는 토양 중 백석면을 분석하는 과정에서 정성, 정량 평가용 표준물질을 개발함으로써 분석결과에 대한 분석기관 및 분석자의 신뢰성 향상과 더불어 광학현미경의 기초자료를 확보고자 한다. 석면분석은 정성분석과 정량분석으로 구분하였으며, 석면정량을 위한 방법은 EPA 600-R-93-116의 점계수법(point counting)으로 총 400지점을 계수하는 방법으로 실시하였다. 제작된 2종에 해당하는 인증표준물질(CRM, Certified Reference Material)을 분산분석과 회귀분석을 이용하여 각각 균질성과 장기 안정성을 확인한 결과 이상이 없음을 확인하였다. 인증표준물질의 인증값은 점계수 결과의 최소값에서 최대값에 이르는 결과를 포함하며 저농도, 1% (범위, 0.25~3.00), 고농도, 4% (범위, 2.25~5.50)로 산출되었다.

광주지역 다중이용시설에서 실내공기질 농도와 상관성 분석 (The Concentration of Indoor Air Quality and Correlations of Materials at Multiple-use Facilities in Gwangju)

  • 이대행;이세행;배석진;김난희;박강수;김도술;백계진;문용운
    • 대한환경공학회지
    • /
    • 제32권11호
    • /
    • pp.1001-1010
    • /
    • 2010
  • 광주지역 다중이용시설 54개소와 공중이용시설 15개소에 대한 입자상물질(미세먼지, 석면), 가스상물질($CO_2$, CO, $NO_2$, HCHO, Rn, VOCs), 총부유세균의 농도에 대해서 조사하고 각 항목간의 상관성분석을 실시하였다. 미세먼지($PM_{10}$)는 실내주차장에서 평균 $69.2\;{\mu}g/m^3$로 가장 높았고, 이어서 보육시설, 대규모점포, 지하역사 순이었다. 일산화탄소는 실내주차장에서 평균 2.7 ppm으로 가장 높았고, 이산화탄소는 의료시설에서 604.1 ppm으로 가장 높았으며, 이산화질소는 실내주차장에서 0.036 ppm으로 가장 높았다. 포름알데하이드는 54개 전체시설에서 기하평균 $3.6\;{\mu}g/m^3$이었으며, 미술관은 $631.8\;{\mu}g/m^3$로 가장 높았다. 휘발성유기화합물질(VOCs)은 모든 시설에서 기하평균 $24.14\;{\mu}g/m^3$이었고, 이 중 톨루엔이 $15.30\;{\mu}g/m^3$로 가장 높았으며, 이어서 자일렌, 에틸벤젠, 벤젠, 스티렌 순으로 조사되었다. 총부유세균은 찜질방에서 평균 $625.3\;CFU/m^3$로 가장 높았고, 보육시설, 의료기관, 대규모점포 순이었다. 석면은 보육시설에서, 라돈은 미술관에서 높은 것으로 조사되었다. 보육시설에서 미세먼지와 총부유세균은 로그함수의 결정계수($R^2$) 0.5332로 양의 상관성을 보여주었고, 이산화탄소와 일산화탄소는 보육시설과 실내주차장에서 양의 상관성을 보여주었다. 휘발성물질간의 상관식은 모든시설에서 직선함수보다는 로그함수에 의해 잘 설명되었다.

고분자담지제에 의한 청주공단내 공장배기가스의 효율적 처리기술대책에 관한 연구(I) -청주공장내 공장배기가스 조사 및 분석을 중심으로- (Study on Effective Treatment of Waste Gases in Chung-Ju Industrial Complex with Polymeric Absorbent( I ))

  • 이상혁;이영순;전종한
    • 한국안전학회지
    • /
    • 제7권2호
    • /
    • pp.24-29
    • /
    • 1992
  • The exhausted gases were analyzed and the countermeasures were studied to solve the environmental pollution caused by waste gases in Chung-Ju Industral Complex. The eleven working places were selected to analysis the compositions and concentrations of the exhausted gases by gas chromatograph and membrane method. The five companies which have used organic solvents were shown lower content than TLV and the environmental limits. But the concentration of lead in a electric product company was revealed higher than TLV. The waste gases of the four companies which have used asbestos were shown lower values than TLV and the environmental limit. The exhausted gases, SO$_2$and NO$_2$of two companies which have used fossile fuels were also analyzed. The NO$_2$concentration of one company which haven't disposal system was shown higher than the environmental limit.

  • PDF

집수빗물이용을 위한 지붕면 재질의 영향 (The Effect of Roofing Materials for Using Harvested Rainwater)

  • 이주영;김충일;김현우;한무영
    • 대한환경공학회지
    • /
    • 제34권9호
    • /
    • pp.623-629
    • /
    • 2012
  • 본 연구는 집수면으로 사용되는 지붕재질에 따라 집수되는 빗물의 수질을 평가하고, 지붕면에서 지의류/이끼의 존재여부에 따른 수질변화를 관찰하였다. 실험은 5가지 다른 재질의 재료[나무, 나무(이끼 서식), 콘크리트, 초벌기와, 슬레이트]로 설치된 지붕면에서 수행되었다. 각 지붕면에서의 빗물수질을 관찰한 결과, 초벌기와 지붕으로부터 집수된 빗물이 이용에 가장 적합한 재료로 나타났다. 이는 초벌기와 재질 특성에 따른 표면 온도의 상승과 자외선에 의한 살균효과 때문인 것으로 판단된다. 이끼류가 포함된 나무지붕과 일반 나무 지붕에서 집수된 빗물의 수질을 비교한 결과 이끼는 TOC, nitrate, sulfate 및 phosphate 농도에 영향을 미치는 것으로 관측되었다. 그리고 슬레이트 지붕으로부터 유출된 빗물 내 석면의 농도는 평균 0.002개/$cm^3$로 검출되었으며 이러한 결과는 환경부 다중이용시설기준 및 노동부 사무실 기준인 0.01개/$cm^3$ 규정을 만족한 것으로 나타났다.

국내 일부학교 건축물의 실내공기질 평가 (The Assessment of Survey on the Indoor Air Quality at Schools in Korea)

  • 손종렬;노영만;손부순
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.140-148
    • /
    • 2006
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.

건물의 실내공기 중 석면 분포 특성 (Characteristics of Indoor air concentration of asbestos in buildings)

  • 김윤신;이철민;박원석;문정숙;엽무종;이태형
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 춘계학술대회 논문집
    • /
    • pp.427-428
    • /
    • 2003
  • 현대인의 경우 대부분이 하루 중 80% 이상의 시간을 어떤 형태의 가정, 사무실, 공공건물, 학교, 병원, 지하시설물, 상가, 음식점, 자동차, 지하철 등의 실내공간에서 생활하고 있으며, 특히 어린이와 노약자, 병약자들의 경우 대부분의 시간을 실내에서 보내고 있는 실정에 있어 실내공기오염이 인체에 미치는 영향은 크다고 할 수 있다. 실내환경에는 대기환경과는 달리 물리적, 화학적, 생물학적으로 매우 다양한 오염물질들은 복합적인 배출원에서 기인되며 그 배출량은 물질에 따라 상당히 편차가 있을 뿐 아니라 오염물질 농도분포 역시 시간적, 공간적 특성에 따라 다양하게 나타날 수 있으며, 실내공기의 상태는 일차적으로 외부공기의 영향을 받게 되고 이차적으로는 담배연기, 스토브, 오븐, 시멘트, 건축자재, 페인트 및 벽면의 입자상 물질 등과 같은 실내오염원으로부터 영향을 받아 오염상태가 심해진다. (중략)

  • PDF

FID를 이용한 수중의 TOC 분석법 (Determination of Total Organic Carbon in Water by Flame Ionization Detector)

  • 박만기;한대석;임병연
    • 약학회지
    • /
    • 제22권3호
    • /
    • pp.157-162
    • /
    • 1978
  • Total organic carbon(TOC) can be determined by means of combustion and flame ionization detector. The principle of string method is that a sample acidified to pH2 and transferred into combustion tube by string is oxidized with air. Another combustion tube method is that organic compounds are oxidized in the combustion tube charged with CuO and cobalt asbestos after the acidified sample is injected directly by microsyringe. Carbon dioxide evolved was reduced under specially treated nickel catalyst and hydrogen, the methane produced was detected by flame ionization detector. Linear relationship was found between concentration and the peak height by the string method. The peak area in the case of combustion tube method is in the range of 1-200ppm. The coefficient of variation by string method was 2.3% and that by combustion tube method was 1.8%. The lower detectable limit was about 10mol. Advantages of the latter are simplicity, sensitivity and reproducibility. TOC in contineous stream can also be determined automatically by means of the string method.

  • PDF

대학도서관 실내 공기질 측정 및 조사 연구 (A Study on the Measurement and Investigation of Air Quality in a University Library)

  • 이재원
    • 한국도서관정보학회지
    • /
    • 제50권4호
    • /
    • pp.635-658
    • /
    • 2019
  • 본 연구에서는 S대학 중앙도서관을 대상으로 측정 유해인자를 ① 공기 중 유해물질 ② 생물학적 유해인자 ③ 일산화탄소·이산화탄소·이산화질소 농도로 구분하여 관련 기준과 비교하여 측정·분석하였다. 분석한 결과 공기 중 유해물질인 미세먼지, 석면, 휘발성 유기화합물, 포름알데히드 모두 관련 기준 보다 낮은 수준으로 나타났으며, 생물학적 유해인자인 공기 중 곰팡이, 그람음성박테리아, 엔도톡신 등도 특별한 문제를 찾을 수 없었다. 공기 중 일산화탄소, 이산화탄소, 이산화질소 농도도 일반 대기 중의 농도 대비 특이한 점이 없이 유지되고 있었다. 다만, 도서관은 다중이용시설로 주기적인 청소와 환기를 통한 환경 관리가 필요한 것으로 나타났다.

국내 정부출연연구기관 및 대학교 실험실 공기 오염물질 농도 및 환기시스템 평가 (Evaluation of Air Contaminants Concentrations and Ventilation Systems in Governmental Agency and University Laboratories)

  • 하주현;신용철;이현석;;이광용;이병규
    • 한국산업보건학회지
    • /
    • 제20권1호
    • /
    • pp.63-69
    • /
    • 2010
  • This study was conducted to compare the concentration of various air contaminants in nine different laboratories during routine activities. Volatile organic compounds (VOC) were sampled and analyzed using NIOSH Method 1500 and asbestos fibers were sampled and analyzed using NIOSH Method 9002 and 7400. Detectable levels of acetone, toluene and ethanol were found in all the laboratories and xylene and n-hexane were detected in eight of the nine laboratories. All the VOC concentrations were well below the Korean Ministry of Labor's Exposure Limit and American Conference of Governmental Industrial Hygienists' (ACGIH) Threshold Limit Values (TLVs). Total VOC concentrations at the university laboratories were significantly higher than those at governmental agency laboratories. Airborne fiber concentrations were below 0.01 fibers/cc, while the concentration of chrysotile was 2% in insulation materials sprayed on the ceiling of one laboratory. While all the governmental agency laboratories (n=4) had fume hoods, two out of the five university laboratories did not have fume hoods. The capture velocity of half of the fume hoods were below the maintenance standard(0.4 m/sec). In conclusion, the study suggests that the current controls in place at both university and government agency laboratories are not sufficient in limiting exposure to harmful chemicals to non-detectable levels, though they appear to be adequate in protecting workers to levels below applicable occupational exposure limits. The study also suggests that researchers working in university laboratories may be exposed to greater levels of contaminant than those working in government agency laboratories.