• 제목/요약/키워드: Asan area

검색결과 379건 처리시간 0.024초

이동형 방사선검사에서 영상의 왜곡과 선량에 관한 연구 (A Study on Distortion and Dose of Images in Mobile Radiography)

  • 송현석;임청환;정홍량;김종성;김영란;정성훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.305-312
    • /
    • 2022
  • The proportion and testing of portable radiation tests, which are limited at the request of the doctor, are gradually increasing only for patients in emergency situations and difficulties in moving. However, as there are many limiting factors compared to fixed devices, this study intends to measure and analyze the distortion of images according to the angle of the detector and the change in dose according to the position of the subject. For distortion experiments using a mobile radiation generator used in Hospital A, the SID was tilted by 110 cm, 14"×17" wireless FPD detector to 0°, -5°, -10°, -15°, -20°, and -35° to measure the change in area. The dose according to the location of the detector was analyzed on average by measuring the central dose at 110 cm of the SID and measuring the dose of 9 locations three times each. The analysis result of distortion by location according to the angle of the detector showed a statistically significant difference (f=58.74, p<0.000). Therefore, it can be seen that the angle of the detector and the tube is closely related to the distortion of the image. The difference in dose by location of the detector increased with respect to the center - pole, and decreased with the + pole. Tests using mobile radiation generators will require careful efforts by clinicians to position patients in the center of the detector for accurate diagnosis, and efforts will be made to level the angle between the mobile radiation generators and the detector.

한국형 환자분류도구-1(KPCS-1)의 신뢰도와 타당도 검증 및 간호시간 환산지수 산출 (Verification of Reliability and Validity of KPCS-1 and Estimation of Nursing Time Conversion Index)

  • 송경자;김은혜;유정숙;박현애;송말순;박광옥
    • 임상간호연구
    • /
    • 제16권2호
    • /
    • pp.127-140
    • /
    • 2010
  • Purpose: This study was performed to verify reliability and validity of Korean Patient Classification System for nurses(KPCS-1), to estimate nursing time conversion index, and to classify patients into groups according to KPCS-1 scores. Methods: KPCS-1 was revised from KPCS by a professional review team. Interrater reliability and construct validity of KPCS-1 were verified by data from 433 patients. Direct and indirect nursing time of 204 patients were measured by stopwatch observation and self reports for 24 hours. Nursing time conversion index was calculated. Results: KPCS-1 consisted of 12 area, 50 nursing activities, and 73 items. The interrater reliability was tested between two nurse group (r=.88, p<.001) and construct validity was verified according to medical department (F=10.97, p<.001) and patient pattern (F=5.54, p=.001). The correlation of nursing time and classification score was also statistically significant (r=.56, p<.001). The nursing time conversion index was 9.03 minutes per 1 classification score. The patients were classified into 4 groups by the classification scores. Conclusion: KPCS-1 can be a useful factor type patient classification system for general ward. Further study is needed to evaluate validity and reliability for refining KPCS-1 and to develop ways connecting the scores with nursing outcomes.

$^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석 (The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET)

  • 박순기;이남기;남궁창경;정우영
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.100-103
    • /
    • 2010
  • $^{18}F$-FDG PET 검사는 포도당 대사를 이용하여 전신의 종양을 평가하는 검사로 전처치 과정에서 혈당 측정의 중요성이 매우 높다. 혈당 수치가 높은 상태에서 FDG를 투여하면 FDG와 혈중 포도당이 세포 내 흡수에 서로 경쟁하게 되고 종양으로의 FDG 섭취가 감소되어 정확한 검사가 되지 않을 가능성이 있다. 혈당 측정에 사용되는 혈당 측정 검사지는 경우에 따라 모세혈관혈 전용 측정 검사지와 모세혈관혈과 정맥혈을 모두 측정 가능한 범용 측정 검사지로 구분되어 있는데, 정확한 혈당 측정 검사지(스트립)의 사용에 따른 혈당 수치의 차이를 비교 분석 하였다. 연구 대상은 2010년 3월부터 4월까지 서울아산병원 핵의학과에서 $^{18}F$-FDG whole body PET 검사를 시행한 환자 중 46명(남자: 32명, 여자: 14명, 평균연령 $57.3{\pm}12.3$세) 을 연구의 대상으로 하였다. 실험기기는 Abbott사의 Optium Xceed혈당 측정기를 이용하였고, 모세혈관혈과 정맥혈을 모두 측정 가능한 범용 측정 검사지를 사용하여 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치의 차이를 분석하였다. 또한, 모세혈관혈 전용 측정 검사지를 사용하여 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치의 차이를 비교 분석하였다. 분석방법은 MINITAB 통계 프로그램을 이용하여 paired t-test 검정을 시행하였다. 모세혈관혈과 정맥혈을 모두 측정 가능한 범용 측정 검사지로 측정한 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치는 각각$95.2{\pm}12.4$ mg/dL, $104.1{\pm}14.4$ mg/dL (t=8.0, p<0.001)로 통계적으로 유의한 차이가 있었다. 모세혈관혈 전용 측정 검사지로 측정한 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치는 각각 $91.5{\pm}13.6$ mg/dL, $108.1{\pm}16.2$ mg/dL (t=9.2, p<0.001)로 통계적으로 유의한 차이가 있었다. 선행연구에 의하면 모세혈관혈과 정맥혈의 혈당 수치는 여러 가지 이유로 인해 차이가 있는 것으로 보고 되었고 본 연구의 결과도 유사한 차이를 확인하였다. $^{18}F$-FDG PET 검사 전에 혈당 수치를 측정할 때 모세혈관혈 전용 측정 검사지로 정맥혈의 혈당을 측정하는 것은 부정확한 혈당 수치를 측정할 수 있으므로 주의해야 할 것이다. 그러므로 적합한 측정 검사지와 규정된 측정절차를 이행하는 것이 측정 편차를 줄일 수 있어 PET 검사의 전처치를 보다 명확하게 확인할 수 있을 것이다. 또한, 혈당 측정 시에 혈액 채취 부위를 모세혈관 또는 정맥혈관 중에서 항상 동일한 부위에서 측정하는 등의 표준화 과정이 필요할 것이다.

  • PDF

방사선 치료 시 환자 Set-up Line 개선을 통한 암환자 삶의 질 만족도 향상 (Improvement of patient's quality of life by improving patient's set-up line in radiotherapy)

  • 최진혁;안우상;이우석;김대용
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.185-189
    • /
    • 2018
  • 목 적 : Set-up Line을 유지하면서 치료 중 씻을 수 있도록 하여 방사선 치료 시 환자의 삶의 질 만족도를 평가하였다. 대상 및 방법 : 2018년 1월 본원에 내원한 환자 60명을 대상으로 반복되는 방사선 치료 시 환자의 불편사항을 조사하였다. 가장 큰 불편사항으로 치료 중 씻지 못하는 것에 대부분 불편함을 호소하였고(64 %), 이에 대한 해결책으로 Set-up Line 위에 외과용 테이프를 부착하여 치료 기간 중 환자분이 씻을 수 있도록 하였다. 외과용 테이프를 적용한 환자 총 50명을 대상으로 5점 기준으로 만족도를 조사하였다(1점 매우 불만족한다, 2점 불만족한다, 3점 보통이다, 4점 만족한다, 5점 매우 만족한다). 50명 중 40명은 치료를 처음 시작한 환자를 대상으로, 10명은 치료 진행 중인 환자를 대상으로 각각 평가를 진행하였다. 결 과 : 1차 설문조사에 응한 환자의 성별은 여성 68 %, 남성 32 %이였으며, 나이는 50대 이하 34 %, 50~60대 38 %, 60대 이상이 28 %로 나타났다. 치료부위는 유방 57 %, 흉부 13 %, 골반부 10 % 등으로 나타났다. 외과용 테이프를 적용 후 2차 설문조사한 결과 치료를 시작한 환자 40명 중 여성 25명, 남성 15명으로 조사되었고, 치료부위는 유방 22명, 골반부 18명으로 나타났다. 5점 척도 기준의 만족도에서 1-3점이 5명, 4-5점이 35명(1점 2명, 2점 2명, 3점 1명, 4점 17명, 5점 18명)으로 매우 만족 45 %, 만족 43 %로 나타났다. 치료를 진행 중에 적용한 환자에 대한 설문조사 결과에서 10명 중 여성 9명, 남성 1명으로 조사되었고, 치료부위는 유방 8명, 골반부 2명으로 나타났다. 5점 척도 기준의 만족도에서 1점이 1명, 5점이 9명으로 90 %가 매우 만족하는 것으로 조사되었다. 결 론 : 방사선 치료 시 정확성도 중요한 만큼 암환자의 삶의 질 향상도 고려해야 할 사항이다. 외과용 테이프를 적용 후, 치료를 시작한 환자의 88 %, 치료 진행 중 적용한 환자의 90 %가 만족을 보임을 알 수 있었다. 특히, 치료 진행 중 적용한 환자에게 더 높은 만족도를 보였다. 이를 통해 모든 환자에게 적용이 어렵다면 불편함을 호소하는 환자에게 선택적으로 적용하는 것도 암환자 삶의 질을 높이는데 큰 도움이 될 것을 판단된다.

  • PDF

A Rule-based Urban Image Classification System for Time Series Landsat Data

  • Lee, Jin-A;Lee, Sung-Soon;Chi, Kwang-Hoon
    • 대한원격탐사학회지
    • /
    • 제27권6호
    • /
    • pp.637-651
    • /
    • 2011
  • This study presents a rule-based urban image classification method for time series analysis of changes in the vicinity of Asan-si and Cheonan-si in Chungcheongnam-do, using Landsat satellite images (1991-2006). The area has been highly developed through the relocation of industrial facilities, land development, construction of a high-speed railroad, and an extension of the subway. To determine the yearly changing pattern of the urban area, eleven classes were made depending on the trend of development. An algorithm was generalized for the rules to be applied as an unsupervised classification, without the need of training area. The analysis results show that the urban zone of the research area has increased by about 1.53 times, and each correlation graph confirmed the distribution of the Built Up Index (BUI) values for each class. To evaluate the rule-based classification, coverage and accuracy were assessed. When Optimal allowable factor=0.36, the coverage of the rule was 98.4%, and for the test using ground data from 1991 to 2006, overall accuracy was 99.49%. It was confirmed that the method suggested to determine the maximum allowable factor correlates to the accuracy test results using ground data. Among the multiple images, available data was used as best as possible and classification accuracy could be improved since optimal classification to suit objectives was possible. The rule-based urban image classification method is expected to be applied to time series image analyses such as thematic mapping for urban development, urban development, and monitoring of environmental changes.

큐렛형 팁을 장착한 압전방식 초음파 치석제거기가 치근대체물 삭제에 미치는 영향 (The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Root Substitute Removal in Vitro)

  • 이영규
    • Journal of Periodontal and Implant Science
    • /
    • 제30권2호
    • /
    • pp.429-442
    • /
    • 2000
  • Based on current evidence in the literature, it is known that endotoxin is a weakly adherent surface phenomenon and that power-driven instruments can be used to accomplish definitive root detoxification and maximal wound healing without overinstrumentation of root and without extensive cementum removal. And one of the newly developed curette tips used with low power of piezoelectric ultrasonic scaler, is effective to remove calculus and not to remove the excessive cementum. The purpose of this study is therefore, to assess the influence of ultrasonic power and various working parameters on root substitute removal when instrumentation is performed with the curette tip on piezoelectric ultrasonic scaler. This study assessed defect depth, width and area resulting from instrumentation using a piezoelectric ultrasonic scaler with a curette type tip in vitro to acrylic resin block as a root substitute. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1 N, 2 N) and instrumentation time(5 sec, 10 sec, 20 sec) and power setting was adjusted 0,2,4,8 in P mode. Power setting had the greatest influence on defect depth compared to lateral force and instrumentation time(standardized regression parameter estimates${\pm}$standard error, $0.37{\pm}0.02$, $0.19{\pm}0.02$, $0.07{\pm}0.02$). The effects on defect area also greatest for power setting($0.57{\pm}0.03$) compared to lateral force and instrumentation time($0.33{\pm}0.03$, $0.12{\pm}0.03$). The effect of the power setting on the defect width($0.15{\pm}0.01$) is not so great as defect depth or defect area compared to lateral force($0.12{\pm}0.01$) and effect of instrumentation time is minimal($0.02{\pm}0.01$). It could be concluded that the power setting has the greatest influence on the defect depth and area in curette type tip with low power of piezoelectric ultrasonic device. Many parameters can be adjusted in various situation in clinical use of piezoelectric ultrasonic scaler but the power setting is the first parameter to be adjusted.

  • PDF

The prognostic value of median nerve thickness in diagnosing carpal tunnel syndrome using magnetic resonance imaging: a pilot study

  • Lee, Sooho;Cho, Hyung Rae;Yoo, Jun Sung;Kim, Young Uk
    • The Korean Journal of Pain
    • /
    • 제33권1호
    • /
    • pp.54-59
    • /
    • 2020
  • Background: The median nerve cross-sectional area (MNCSA) is a useful morphological parameter for the evaluation of carpal tunnel syndrome (CTS). However, there have been limited studies investigating the anatomical basis of median nerve flattening. Thus, to evaluate the connection between median nerve flattening and CTS, we carried out a measurement of the median nerve thickness (MNT). Methods: Both MNCSA and MNT measurement tools were collected from 20 patients with CTS, and from 20 control individuals who underwent carpal tunnel magnetic resonance imaging (CTMRI). We measured the MNCSA and MNT at the level of the hook of hamate on CTMRI. The MNCSA was measured on the transverse angled sections through the whole area. The MNT was measured based on the most compressed MNT. Results: The mean MNCSA was 9.01 ± 1.94 ㎟ in the control group and 6.58 ± 1.75 ㎟ in the CTS group. The mean MNT was 2.18 ± 0.39 mm in the control group and 1.43 ± 0.28 mm in the CTS group. Receiver operating characteristics curve analysis demonstrated that the optimal cut-off value for the MNCSA was 7.72 ㎟, with 75.0% sensitivity, 75.0% specificity, and an area under the curve (AUC) of 0.82 (95% confidence interval [CI], 0.69-0.95). The best cut off-threshold of the MNT was 1.76 mm, with 85% sensitivity, 85% specificity, and an AUC of 0.94 (95% CI, 0.87-1.00). Conclusions: Even though both MNCSA and MNT were significantly associated with CTS, MNT was identified as a more suitable measurement parameter.

2D 혈관조영술에서 직접 측정한 혈관 직경과 MR 영상에서 단면적 기반 환산 직경의 비교 분석 (Comparative Analysis between Directly Measured Diameter in 2D Angiography and Cross-Sectional Area-Converted Diameter in MR Image)

  • 이기백;김미현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권5호
    • /
    • pp.427-433
    • /
    • 2023
  • This study aimed to quantitatively compare the diameters measured directly from the coronal plane or sagittal plane of 2D digital subtraction angiography (DSA) and the cross-sectional area-converted diameters calculated from contrast-enhanced MR (CE-MR) imaging. A retrospective analysis was conducted on 20 patients who underwent both 2D DSA and CE-MR imaging. Firstly, the venous diameters of the superior sagittal sinus (SSS) and transverse sinus (TS) were directly measured from 2D DSA. Subsequently, the axial planes for SSS diameter and the sagittal plane for TS in CE-MR imaging were utilized to calculate cross-sectional area-based converted diameters. The numerical values obtained from 2D DSA and CE-MR imaging were compared pairwise at each location. For SSS, the diameter measured by 2D DSA was 27% larger than the conversion-based diameter from CE-MR imaging (9.8±1.4 mm vs. 7.1±1.3 mm, P<0.05). Similarly, for the right TS, the difference was 16% (8.8±3.2 mm vs. 7.4±2.0 mm, P<0.05), and for the left TS, the difference was 22% (8.4±2.8 mm vs. 6.6±1.3 mm, P<0.05). In conclusion, the diameter measured directly in conventional 2D DSA may be larger than the diameter converted based on the cross-sectional area. Therefore, when selecting the size of the stent, it is crucial to make precise determinations while keeping this fact in mind.

대형 민간병원의 사례분석에 의한 사용자별 면적배분 현황에 대한 연구 (A research on User-focused Space analysis of representing large Corporate hospitals)

  • 이정만;최아현
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제1권2호
    • /
    • pp.39-51
    • /
    • 1996
  • Design scheme drawings of the two major corporate hospitals - Asan Medical Center and Samsung Medical Center - are analysed in the aspect of floor area distributions and their proportions for various users and user-functions. Primary users of hospitals are categorized into three ; patients, employees and others. Then, patient spaces are subdivided into patient private, patient/medical, patient/support staff, patient/nursing, patient/guardian, patient common ; employee spaces into doctors, trainees, doctors common, nurses, support staffs, non-medical staffs, employee common ; others spaces into subcontractors, general publics, non-living, and internal circulation. The purpose of this research is to develop a user-focused insight into hospital spaces and a new method of hospital programming and design.

  • PDF

F18-FDG PET/CT에서 우연히 발견된 비인두 결핵 1예 (A Case of Incidentally Detected Nasopharyngeal Tuberculosis on F-18 FDG PET/CT)

  • 이재현;김재승
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권6호
    • /
    • pp.482-484
    • /
    • 2008
  • It is well known that F18-FDG PET/CT is a highly sensitive diagnostic modality for cancer patients. However, false positive cases resulting from benign disease such as tuberculosis in the endemic area often compromise the diagnostic accuracy of F18-FDG PET/CT. Nasopharyngeal tuberculosis is a rare disease although extrapulmonary tuberculosis can involve any region in the body. We report one case of nasopharyngeal tuberculosis incidentally detected on F18-FDG PET/CT.