• Title/Summary/Keyword: AsGeSeS

Search Result 118, Processing Time 0.027 seconds

Dynamic Responses of the TRU-loaded HYPER System

  • Kim, T.K.;Oh, Se-Kee;Kim, Y.H.;Park, W.S.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2000.11a
    • /
    • pp.127-137
    • /
    • 2000
  • Accelerator Driven System (ADS) named HYPER(Hybrid Power Extraction Reactor) is being developed for the transmutation of nuclear waste in Korea Atomic Energy Research Institute(KAERI). The concept of the HYPER is using 1GeV proton to drive a subcritical core. HYPER system is believed to have much more stable dynamics than the critical system in terms of neutronics. However, the HYPER system is supposed to have some drawbacks for the cooling system accidents. Loss of Flow(LOF) and Loss of Heat Sink (LOHS) cause a strong damage. As results, those accidents would stop the power production in the critical system. On the other hand, the negative reactivity feedback could not stop the HYPER system because the HYPER is driven by an accelerator rather than reactivity.(omitted)

  • PDF

The Photoinduced Birefringence of Chalcogenide Thin Film by the Ag Polarized-photodoping (Ag 편광-광도핑에 의한 칼코게이나이드 박막의 광유기 복굴절)

  • 장선주;박종화;박정일;정홍배
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.2
    • /
    • pp.139-144
    • /
    • 2001
  • In this study, we have investigated the photoinduced birefringence of Ag plarized-photodoping in double-layer of Ag doped chalcognide thin films and dependence of polarization states in chalcogenide thin films. Also, we have investigated the polarization dependence of photoinduced birefringence and the anisotropy of absorption in an amorphous As$\sub$40/Ge$\sub$10/Se$\sub$15/S$\sub$35/ chalcogenide thin films using two 632.8nm He-Ne lasers, which have a smaller energy than the optical energy gap (E$\sub$OP/) of the film, i.e., an exposure of sub-bandgap light (hν$\sub$op/). The photoinduced phenomena of Ag polarized-photodooping increasing the linear dichroism(d), about 84% and birefringence(Δn), about 23%. It will offer lots of information for the photodoping mechanism and analysis of chalcogenide thin films.

  • PDF

Amorphous chalcogenide thin films of relief grating formation by using He-Cd laser (He-Cd 레이져를 이용한 비정질 칼코계나이드 박막의 relief 격자 형성)

  • Lee, Ki-Nam;Park, Jung-Il;Yang, Sung-Jun;Lee, Young-Jong;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1058-1061
    • /
    • 2003
  • In this thesis, we observed the optical characteristic of amorphous chalcogenide thin films by He-Cd laser. Also, grating formation by He-Ne laser and He-Cd laser. After analyze diffraction efficiency of the time on the $Ag(200{\AA})/As_{40}Ge_{10}Se_{15}S_{35}$ thin films. The result diffraction efficiency of Maximun 0.2% reduced according to time grating formation by He-Ne laser. Diffraction efficiency of Maximun 0.1% showed stabiliy characteristic according to time grating formation by He-Cd laser.

  • PDF

A Study of Diffraction Efficiency Depended on $Ag^+$ of Amorphous Chalcogenide Thin Films (Amorphous chalcogenide 박막의 $Ag^+$ 의존적 회절효율 특성에 관한 연 구)

  • Jeong, Won-Kook;Nam, Ki-Hyun;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.134-134
    • /
    • 2010
  • We have investigated the holographic grating formation on Ag-doped amorphous chalcogenide AsGeSeS thin films with Ag thickness. Holographic gratings have been formed using Diode Pumped Solid State laser (DPSS, 532.0nm) under [P:P] polarized the intensity polarization holography. The diffraction efficiency was obtained by +1st order intensity.

  • PDF

The Elimination Characteristics by Impressed Voltage of Holography Grating in Chacogenide Thin Film

  • Lee Ki-Nam;Yeo Cheol-Ho;Yang Sung-Jun;Chung Hong-Bay
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.6
    • /
    • pp.219-222
    • /
    • 2004
  • This paper discovers that there are some peculiar properties that can remove holography grating, which was made in chacogenide thin film by impressed voltage. The thin films were used are $As_{40}Ge_{10}Se_{15}S_{35}$, and we use He-Ne laser in order to form thin films. I-V curved line in a thin film before a lattice was made has the critical point, about 3.7 V. Moreover, the I-V curved line increased current intensity at over 4 V after it made thin film. In addition, while holography grating is being made, and when it has the highest diffraction efficiency, a lattice can be deleted if put more voltage into it.

The Measurement of Flash Point for Binary Mixtures of 2,2,4-Trimethylpentane, Methylcyclohexane, Ethylbenzene and p-xylene at 101.3 kPa

  • Hwang, In Chan;In, Se Jin
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.279-285
    • /
    • 2020
  • Laboratories and industrial processes typically involve the use of flammable substances. An important property used to estimate fire and explosion risk for a flammable liquid is the flash point. In this study, flash point data at 101.3 kPa were determined using a SETA closed cup flash point tester on the following solvent mixtures: {2,2,4-trimethylpentane + methylcyclohexane}, {2,2,4-trimethylpentane + ethylbenzene}, and {2,2,4-trimethylpentane + p-xylene}. The purpose of this work is to obtain flash point data for binary mixtures of 2,2,4-trimethylpentane with three hydrocarbons (methylcyclohexane, ethylbenzene, and p-xylene), which are representative compounds of the main aromatic hydrocarbon fractions of petroleum. The measured flash points are compared with the predicted values calculated using the GE models' activity coefficient patterns: the Wilson, the Non-Random Two-Liquid (NRTL), and the UNIversal QUAsiChemical (UNIQUAC) models. The non-ideality of the mixture is also considered. The average absolute deviation between the predicted and measured lower flash point s is less than 1.99 K, except when Raoult's law is calculated. In addition, the minimum flash point behavior is not observed in any of the three binary systems. This work's predicted results can be applied to design safe petrochemical processes, such as identifying safe storage conditions for non-ideal solutions containing volatile components.

Analysis of noise rejection of stored holographic digital data on the chalcogenide thin film (칼코게나이드 박막에 저장된 홀로그래픽 디지털 정보의 잡음 제거에 관한 연구)

  • Lim, Byoung-Rock;Lee, Woo-Sung;Ahn, Kwang-Seop;Yeo, Cheol-Ho;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.479-480
    • /
    • 2005
  • The Analog data is impossible to perfect reconstruct original data at a hologram data storage because of noise such as cross talk. So it is necessary that data can be stored by digital signal unavoidably. Therefore this work deals with experiments from this point of view through writing & reading of digital data. We stored 256bit digital data at one point on As-Ge-Se-S chalcogenide thin film and we reconstruct original data of 100% through the specified algorithm such as the histogram equalization, the interactive correction, etc. This result shows that the data is able to reconstruct under relative low diffraction efficiency. As the result, we expect the possibility of chalcogenide thin film for HDDS as the analysis of the effective resolution refer to reconstruction rate and diffraction efficiency.

  • PDF

Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan (두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가)

  • Seo, Sung Gook;Kwon, Dong Yeol;Park, Se Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Purpose: The size, shape, and volume of prosthetic appliance depend on the metal artifacts resulting from dental implant during head and neck treatment with radiation. This reduced the accuracy of contouring targets and surrounding normal tissues in radiation treatment plan. Therefore, the purpose of this study is to obtain the images of metal representing the size of tooth through MVCT, SMART-MAR CT and KVCT, evaluate the volumes, apply them into the proton therapy plan, and analyze the difference of dose distribution. Materials and Methods : Metal A ($0.5{\times}0.5{\times}0.5cm$), Metal B ($1{\times}1{\times}1cm$), and Metal C ($1{\times}2{\times}1cm$) similar in size to inlay, crown, and bridge taking the treatments used at the dentist's into account were made with Cerrobend ($9.64g/cm^3$). Metal was placed into the In House Head & Neck Phantom and by using CT Simulator (Discovery CT 590RT, GE, USA) the images of KVCT and SMART-MAR were obtained with slice thickness 1.25 mm. The images of MVCT were obtained in the same way with $RADIXACT^{(R)}$ Series (Accuracy $Precision^{(R)}$, USA). The images of metal obtained through MVCT, SMART-MAR CT, and KVCT were compared in both size of axis X, Y, and Z and volume based on the Autocontour Thresholds Raw Values from the computerized treatment planning equipment Pinnacle (Ver 9.10, Philips, Palo Alto, USA). The proton treatment plan (Ray station 5.1, RaySearch, USA) was set by fusing the contour of metal B ($1{\times}1{\times}1cm$) obtained from the above experiment by each CT into KVCT in order to compare the difference of dose distribution. Result: Referencing the actual sizes, it was appeared: Metal A (MVCT: 1.0 times, SMART-MAR CT: 1.84 times, and KVCT: 1.92 times), Metal B (MVCT: 1.02 times, SMART-MAR CT: 1.47 times, and KVCT: 1.82 times), and Metal C (MVCT: 1.0 times, SMART-MAR CT: 1.46 times, and KVCT: 1.66 times). MVCT was measured most similarly to the actual metal volume. As a result of measurement by applying the volume of metal B into proton treatment plan, the dose of $D_{99%}$ volume was measured as: MVCT: 3094 CcGE, SMART-MAR CT: 2902 CcGE, and KVCT: 2880 CcGE, against the reference 3082 CcGE Conclusion: Overall volume and axes X and Z were most identical to the actual sizes in MVCT and axis Y, which is in the superior-Inferior direction, was regular in length without differences in CT. The best dose distribution was shown in MVCT having similar size, shape, and volume of metal when treating head and neck protons. Thus it is thought that it would be very useful if the contour of prosthetic appliance using MVCT is applied into KVCT for proton treatment plan.

The dependence of the electric field effect of diffraction efficiency using polarization beam on calcogenide thin films (칼코게나이드 박막에서 편광 빔 회절 효율의 전계 효과 의존성)

  • Jang, Sun-Joo;Yeo, Cheol-Ho;Park, Jeong-Il;Lee, Hyun-Yong;Chung, Hong-Bay
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1861-1863
    • /
    • 1999
  • The polarization gratings were fabricated in chalcogenide $As_{40}Ge_{10}Se_{15}S_{35}$ thin film applicable to a medium of the polarization holography and their diffraction efficiencies$(\eta)$ were monitored by real-time measurement. The polarization gratings prepared consisted of the multi-layer thin film system. As a method to improve the $\eta$, we have investigated its change for the field effect. As the results, the value of $\eta$ strongly depended on the voltage applied to the film and the maximum value, $\eta_{max}$ was enhanced to be about 4 times in comparison with that of not biased sample. In addition, an increase in the $\eta$ can be estimated to be due to additional creation of new defects caused by the electric field across the film.

  • PDF

State and subject of health and sports medical devices industry at oversea

  • Seo, Jung-Hwa;Kim, Se-Jin
    • Journal of Sport and Applied Science
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 2017
  • Most of people do not remind of 'Who is domestic medical device business?' A lot of people that Johnson and Johnson, GE and Philips and other foreign companies belong to medical device company. In fact, local enterprises small place based on world market. Local medical device industry's production has grown up rapidly last 10 years. Sales increased nearly 3 times from trillion and 500 billion KRW in 2004 to 4 trillion and 600 billion KRW in 2014. The production record constantly increased owing to safety and good quality of domestic medical devices. As many as 59% of medical devices made in Korea is exported to 198 countries in the world. Currently, medical device industry in the world has been given considerable attention. Cognition and awareness are very much low. Medical device industry, high income creating industry, is said to next generation industry to increase scale, and Korea does not follow world flow. The industry is given support from the government that is not enough. Korean enterprises have small scale among a lot of global enterprises. Being interested in development of medical devices, the author selected department of IT at college.