• Title/Summary/Keyword: As(V) ion

Search Result 1,278, Processing Time 0.034 seconds

Influence of the Density Gradient on the Current of the Electrode Immersed in the Non-uniform Plasma (플라즈마 삽입전극의 전류에 미치는 밀도 구배의 영향)

  • Hwang, Hui-Dong;Gu, Chi-Wuk;Chung, Kyung-Jae;Choe, Jae-Myung;Kim, Gon-Ho;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.6
    • /
    • pp.504-509
    • /
    • 2011
  • The conducting current of non-uniform plasma immersed electrode consists of ion current and secondary electron emission current caused by the impinging ion current. The ion current is determined by the ion dose passing through the sheath in front of electrode and the ion distribution in front of the electrode plays an important role in the secondary electron emission. The investigation of the distributed plasma and secondary electron effect on electrode ion current was carried out as the stainless steel electrode plugged with quartz tube was immersed in the inductively coupled Ar plasma using the antenna powered by 1 kw and the density profile was measured. After that, the negative voltage was applied by 1 kV~6 kV to measure the conduction current for the analysis of ion current.

Effect of Incident Ion Beam Energy on Microstructure and Adhesion Behavior of TiN Thin Films (TiN 박막의 미세조직 및 밀착력에 미치는 입사이온빔 에너지의 효과)

  • Baeg, C.H.;Hong, J.W.;Wey, M.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.18 no.4
    • /
    • pp.229-234
    • /
    • 2005
  • Effect of incident ion beam energy on microstructure and adhesion behavior of TiN thin films were studied. Without ion beam assist, TiN film showed (111) growth mode which was thought to have the lowest deformation energy. As the ion beam assist energy increased, TiN film growth mode was changed from (111) to (200) mode. On the Si(100) substrate the critical incident energy for growth mode change was 100 eV/atom, however the critical assist energy was 121 eV/atom on the STD61 substrate. Grain size of TiN films increased with the assist ion beam energy. Finally, adhesion strength of TiN films bombarded above the critical ion assist energy showed 4~5 times higher values than that with lower bombard ion energy.

MD simulation of structural change of polyethylene induced by high energy ion bombardment

  • Kim, Chan-Soo;Ahmed, Sk. Faruque;Moon, Myoung-Woon;Lee, Kwang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.358-358
    • /
    • 2010
  • Ion beam bombardment at low energy forms nanosize patterns such as ripples, dots or wrinkles on the surface of polymers in ambient temperature and pressure. It has been known that the ion beam can alter the polymer surface that induces skins stiffer or the density higher by higher compressive stress or strain energies associated with chain scissions and crosslinks of the polymer. Atomic scale structure evolution in polymers is essential to understand a stress generation mechanism during the ion beam bombardment, which governs the nanoscale surface structure evolution. In this work, Molecular Dynamics (MD) simulations are employed to characterize the phenomenon occurred in bombardment between the ion beam and polymers that forms nanosize patterns. We investigate the structure evolution of Low Density Polyethylene (LDPE) at 300 K as the polymer is bombarded with Argon ions having various kinetic energies ranging from 100 eV to 1 KeV with 50 eV intervals having the fluence of $1.45\;{\times}\;1014 #/cm2$. These simulations use the Reactive Force Field (ReaxFF), which can mimic chemical covalent bonds and includes van der Waals potentials for describing the intermolecular interactions. The results show the details of the structural evolution of LDPE by the low energy Ar ion bombardment. Analyses through kinetic and potential energy, number of crosslinks and chain scissions, level of local densification and motions of atoms support that the residual strain energies on the surface is strongly associated with the number of crosslinks or scissored chains. Also, we could find an optimal Ar ion beam energy to make crosslinks well.

  • PDF

Calculation of Sputter Yield using Monte Carlo Techniques (몬테카를로 방식에 의한 스퍼터율 계산에 관한 연구)

  • 반용찬;이제희;원태영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.12
    • /
    • pp.59-67
    • /
    • 1998
  • In this paper, a rigorous three-dimensional Monte Carlo approach to simulate the sputter yield as a function of the incident ion energy and the incident angle as well as the atomic ejection distribution of the target is presented. The sputter yield of the target atom (Cu, Al) has been calculated for the different species of the incident atoms with the incident energy range of 10 eV ~ 100 KeV, which coincides with the previously reported experimental results. According to the simulation results, the calculated sputter yield tends to increase with the amount of the energy of the incident atoms. Our simulation revealed that the maximum sputter yield can be obtained for the incident atom with 10 KeV for the heavy ion, while the maximum sputter yield for the light ion is for the incident atoms with an energy less than 1 KeV. The sputter yield increases with angle of incidence and seems to have the maximum value at 68$^{\circ}$. For angular distributions of the sputtered particle, the atoms in the direction normal to the surface increase with angle of incidence. Furthermore, we has conducted the parallel computation on CRAY T3E supercomputer and built a GUI(Graphic User Interface) system running the sputter simulator.

  • PDF

Fluorometric Quantitative Analysis of Al(III) Ion Using 5-Methoxy-2-phenyliminomethylphenol

  • Kim, Sun-Deuk;Lee, Hye-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1026-1030
    • /
    • 2009
  • A novel Schiff base ligand (N, O system) 5-methoxy-2-phenyliminomethylphenol ($5-CH_3O-PMP$) was synthesized. Using the synthesized ligand as a fluorescent reagent, a fluorometric method was developed for the quantitative analysis of Al(III) ion. The quantitative analysis of Al(III) ion was performed by making the complex compound between Al(III) ion and $5-CH_3O-PMP$ in ethanol-water solution (85/15, v/v, pH 6.2). The excitation wavelength (${\lambda}em$) of the complex compound was 397 nm while the emmision wavelength (${\lambda}em$) was 498 nm. The quantitative analysis of Al(III) ion was carried out by estimating the fluorescence intensity. The various calibration curves were used for the quantitative analysis in the range of 0.27$\sim$27 ng/mL Al(III) ion concentrations. The detection limit was 0.027 ng/mL. Using the fluorometric method developed in this study, satisfying results were obtained from various samples such as tap water, hot spring water, river water, sea water and waste water, which contained considerable amounts of interfering ions.

Room-Temperature Luminescence from Ion Beam or Atmospheric Pressure Plasma-Treated SrTiO3

  • Song, J.H.;Choi, J.M.;Cho, M.H.;Choi, E.J.;Kim, J.;Song, J.H.
    • Applied Science and Convergence Technology
    • /
    • v.23 no.5
    • /
    • pp.261-264
    • /
    • 2014
  • $SrTiO_3$ (STO) single crystal irradiated with a 3-MeV proton beam exhibits blue and green mixed luminescence. However, the same proton beam when used to irradiate STO with a very thin layer of deposited Pt does not show any luminescence. This Pt layer prevents any damage which may otherwise be caused by arcing, which stems from the accumulated surface voltage of tens of kV due to the charge induced by secondary electrons on the surface of the insulator during the ion beam irradiation process. Hence, the luminescence of ion-irradiated STO originates from the modification of the STO surface layer caused by arcing rather than from any direct ion beam irradiation effect. STO treated with atmospheric-pressure plasma, a simple and cost-effective method, also exhibits the same type of blue and green mixed luminescence as STO treated with an ion beam, as the plasma also creates a layer of surface damage due to arcing.

The Characteristic Study on the Extraction of a Co Ion in the Metal Ion Implanter (금속이온 주입기에서의 Co 이온의 인출 특성 연구)

  • Lee, Hwa-Ryun;Hong, In-Seok;Trinh, Tu Anh;Cho, Yong-Sub
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.236-243
    • /
    • 2009
  • Proton Engineering Frontier Project (PEFP) has supplied the metal ions to users by using an installed metal ion implanter of 120 keV. At present a feasibility study is being performed for a cobalt ion implantation. For a cobalt ion extraction we studied to sustain the high temperature($648^{\circ}C$) for metal ions vaporization from a cobalt chloride powder by using an alumina crucible in the ion source. The temperature condition of the crucible was satisfied with the plasma generation at the arc current of 120V and EHC power of 250W. The extracted beam current of $Co^+$ ions was dependent on the arc current in the plasma. The maximum beam current was $100{\mu}A$ at 0.18A of the arc current. The 3 peak currents of the extracted ions such as $Co^+$, $CoCl^+$ and $Cl^+$ were obtained by adjusting a mass analyzing magnet and the $Co^+$ ion beam peak current fraction as around 70% in the sum of the peak currents. The fluence of the implanted cobalt ions at the $10{\mu}A$ of the beam current and 90 minutes of the implantation time into an aluminum sample as measured around $1.74{\times}10^{17}#/cm^2$ by a quantitative analysis method of RBS (Rutherford Backscattering Spectrometry).

Electrochemical Behaviors of Sparteine-Copper (II) Dihalide

  • Sung-Nak Choi;Jin-Hyo Park;Young-In Kim;Yoon-Bo Shim
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.3
    • /
    • pp.276-281
    • /
    • 1991
  • Electrochemical behaviors of optically active sparteine-Cu(II) dihalide complexes were investigated by polarography and cyclic voltammetry (CV). These Cu(II) complexes are rather easier to be reduced to Cu(I) states when comparison is made with other nonplaner copper complexes, We have assigned the CV peaks and polarographic waves related to the redox processes for these complexes. We could also observe the exchange reaction of Cu(II) ion in the complex with mercury metal in the cell having mercury pool. The redox mechanism of these complelxes is as follows; The 1st wave appeared at +0.47 V/+0.65 V corresponds to the reaction of $SpCuX_2+ e{\rightleftarrow}SpCuX_{2^-}$ and the 2nd one at +0.26 V/+0.21 V does the reaction of $SpCuX_{2 ^-} +e{\rightleftarrow}SpCuX_2^{2-}$. The 3rd one at -0.35 V/-0.27 V is dueto the reduction of mercury complex formed via exchange reaction. Where, X is chloride ion.

The Adsorption and Elution Characteristics of Copper Ions in Electrochemical Ion Exchange Electrode Fabricated by the Compressed Diecasting (압착성형법으로 제작된 전기화학적 이온교환 전극에서 구리이온의 흡착과 용출특성)

  • Park, Sei-Yong;Kim, Lae-Hyun;Joe, Young-Il
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.574-578
    • /
    • 1998
  • Electrochemical Ion Exchang(EIX) electrode containing Amberlite IRP-64 as a cation ion exchange resin and Stylene-Buthylene-Rubber(SBR) as a binder was fabricated by the compressed diecasting method. The adsorption and elution characteristics in copper sulfate solution were investigated at the various electrode potentials and electrolyte pHs. In the adsorption process, it was found that the maximum adsorption rate of copper was obtained at -1800 mV and the ratio of adsorption was 92% during 90 min. In the elution process, the elution rate of copper was increased in proportion to anodic potential in the present experimental range and the ratio of elution was 88% during 50 mins at 3600 mV. The adsorption and elution processes were significantly affected by the variation of local pH in the vicinity of electrochemical ion exchange electrode. The higher performances of adsorption and elution were elution were obtained at basic and acidic eletrolytes.

  • PDF

The Effect of Ion Implantation on the Barrier Height in PtSi-nSi Schottky Diode (PtSi-nSi 쇼트키 다이오드에서 이온 주입이 장벽높이의 변화에 미치는 영향)

  • Lee, Yong Jae;Lee, Moon Key;Kim, Bong Ryul
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.5
    • /
    • pp.712-718
    • /
    • 1986
  • A shallow n+ layer of implanted phosphorus was used to lower the barrier height of PtSinSi schottky diodes. The reduction of barrier height of the forward turn-on voltages from 400mV to 180mV of the forward was followed by implantation of phosphorus at 35KeV with an ion dose of 8.0x10**12 atoms/cm\ulcornerand was activated at 925\ulcorner for 30min in dry O2. The test result showed that, as the ion-implanted dose increased, the forward turn-on voltage and reverse breakdown voltage were linearly decreased, but the saturation current and ideality factor(n) were linearly increased.

  • PDF