• Title/Summary/Keyword: Artifacts

Search Result 1,666, Processing Time 0.026 seconds

An Analysis on the Archivist's Perception of the Artifacts Management in Korean Central Governments (중앙행정부처 기록관리요원의 행정박물관리에 대한 인식 분석)

  • Cho, In-Sook;Kim, Hyung-Joo
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.23 no.3
    • /
    • pp.177-191
    • /
    • 2012
  • The purpose of this study is to suggest some guidelines for improving the management of administrative artifacts based on the analysis on archivist's perception. The study investigated the current state of record centers and the archivist's perception in 15 ministries of Korean central government, most of the central ministries did not enact the administrative artifacts management rule. Also it isn't done correctly unlike perception of need to manage administrative artifacts. It is necessary to educate about administrative artifacts management regularly and to develop central ministries collection.

Conservation of Bronze Artifacts from Kimhae Yangdong-ri Site (김해 양동리 출토 유물 보존처리)

  • Eun, Yu-Jae;Kang, Hyung-Tae
    • 보존과학연구
    • /
    • s.16
    • /
    • pp.18-40
    • /
    • 1995
  • Twelve bronze artifacts and silver earring from Kimhae Yangdong-ri Site were treated by B.T.A(Benzotriazole) for the stabilization of copper alloys and impregnated with Incralac for consolidation. Bronze artifacts were analyzed qualitatively by X-rayfluorescence. It was found that elemental composition of bronze artifacts were Cu-Sn-Pbsystem wint some impurities such as Bi, As, Fem Sb, and Ag.

  • PDF

The elimination of the linear artifacts by the metal restorations in the three dimensional computed tomographic images using the personal computer and software (개인용 컴퓨터와 소프트웨어를 이용한 3차원 전산화단층영상에서의 금속 수복물에 의한 선상 오류의 제거)

  • Park Hyok;Lee Hee-Cheol;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.33 no.3
    • /
    • pp.151-159
    • /
    • 2003
  • Purpose: The purpose of this study is to evaluate the effectiveness and usefulness of newly developed personal computer-based software to eliminate the linear artifacts by the metal restorations. Materials and Methods: A 3D CT image was conventionally reconstructed using ADVANTAGE WINDOWS 2.0 3D Analysis software (GE Medical System, Milwaukee, USA) and eliminated the linear artifacts manually. Next, a 3D CT image was reconstructed using V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea) and the linear artifacts eliminated manually in the axial images by a skillful operator using a personal computer. A 3D CT image was reconstructed using V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea) and the linear artifacts were removed using a simplified algorithm program to eliminate the linear artifacts automatically in the axial images using a personal computer, abbreviating the manual editing procedure. Finally, the automatically edited reconstructed 3D images were compared to the manually edited images. Results and Conclusion: We effectively eliminated the linear artifacts automatically by this algorithm, not by the manual editing procedures, in some degree. But programs based on more complicated and accurate algorithms may lead to a nearly flawless elimination of these linear artifacts automatically.

  • PDF

Adaptive Deringing filter's Design and Performance Analysis on Edge Region Classification (윤곽 영역 분류에 기반한 적응형 디링잉 필터의 설계 및 성능 분석)

  • Cho Young;Park Chang-Han;Namkung Jae-Chan
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.10
    • /
    • pp.1378-1388
    • /
    • 2004
  • This paper proposes method to improve the image quality degradation that show when reconstructing compressed images at low bit rate by using wavelet transform. The image quality distortion is blocking artifacts and noise in DCT's compression but blocking artifacts of wavelet transform does not appear and ringing artifacts was appeared near the edge. This proposed technique is classified to part which is ringing artifacts of the edge vicinity appears which is not, apply adaptive filter to each region improved image. A edge region which is harsh to the eye is applied by Canny mask and finding strong edge region, search the neighborhood classify the flat region and the texture region, and apply to each region suitable filter, As experiment result, PSNR value of method that is proposed in that low bit rate compression image that ringing artifact appears became low about 0.05db, but 0.023db degree rose strong edge region and nat region's image. Also, showed picture quality improved more than ringing artifacts in nat region when see from subjective viewpoint of human.

  • PDF

A Change Tracking Technique for Maintaining Consistency of Game Design Artifacts (게임 기획 산출물의 일관성 유지를 위한 변경 추적 기법)

  • Park Jae-Hyun;Yi Du-Won;Rhew Sung-Yul
    • The KIPS Transactions:PartD
    • /
    • v.13D no.1 s.104
    • /
    • pp.103-110
    • /
    • 2006
  • The Game development process that the Korea Game Development Infinity researches and publishes has laid important groundwork for the game industry. However, the game design cannot guarantee a software quality because an artifact is made incorrect by a game planner's new idea and modification. In this paper theorized the system to maintain artifacts consistently that is generated in planning phase and make changed contents traceable. First, it defined an ACT graph to represent relation of between artifacts, a ACT table that traces and manages it changes and a table of artifacts change history. Also, it suggested the ACT process applying as we mentioned above. Then we worked a case study to verify the change tracking technique which is presented. In a case study, we find game designer is capable to grip and modify a change of artifacts when it occurs a change of game design artifacts. As a result of that, we can save the time and effort to maintain the consistency among game design artifacts.

Manufacturing Techniques and Alloying Compositions of Metal Decorative Artifacts in 18th Century, Myanmar

  • Lee, Jae Sung;Win, Yee Yee;Lee, Bonnie;Yu, Jae Eun
    • Journal of Conservation Science
    • /
    • v.36 no.4
    • /
    • pp.296-305
    • /
    • 2020
  • Konbaung Dynasty was the last unified dynasty that ruled Myanmar from 18th to 19th century. During this time Buddhist art flourished in Myanmar due to the interest of the rulers toward their traditional culture. Metal decorative artifacts in the 18th century are classified into structures and Buddha statues. They are further subdivided into gilt-bronze and bronze objects, depending on their material component. Three-dimensional gilt-bronze decorative artifacts were cast with a brass alloy of Cu-Zn-Sn-Pb and their surfaces were gilded with extremely thin gold leaves (less than 1 ㎛ in thickness). The gilded layer approximately comprised 10 wt% silver in addition to the main element, gold. The lack of Hg in the gilded layer, indicated that the amalgam gilding technique was not applied. The analysis results indicated that the lacquered gilding technique was applied to the objects. Bronze decorative artifacts without gilding were cast with materials containing Cu-Sn-Pb. The bronze pavilions and bronze Buddha staues were crafted using the same alloy of high-tin bronze, which approximately contained 20 wt% Sn. No heat treatment was applied to reduce the brittleness of the objects after they were cast with a large amount of Sn. The most significant difference between the gilt-bronze and bronze decorative artifacts lie in their elemental compositions. The gilt-bronze decorative artifacts with their gilded surface were manufactured using brass containing zinc, while the unplated bronze decorative artifacts were composed of bronze containing tin. Artifacts of the same type and size are classified differently depending on the materials utilized in the surface treatment such as gilding.

Image Calibration Techniques for Removing Cupping and Ring Artifacts in X-ray Micro-CT Images (X-ray micro-CT 이미지 내 패임 및 동심원상 화상결함 제거를 위한 이미지 보정 기법)

  • Jung, Yeon-Jong;Yun, Tae-Sup;Kim, Kwang-Yeom;Choo, Jin-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.11
    • /
    • pp.93-101
    • /
    • 2011
  • High quality X-ray computed microtomography (micro-CT) imaging of internal microstructures and pore space in geomaterials is often hampered by some inherent noises embedded in the images. In this paper, we introduce image calibration techniques for removing the most common noises in X-ray micro-CT, cupping (brightness difference between the periphery and central regions) and ring artifacts (consecutive concentric circles emanating from the origin). The artifacts removal sequentially applies coordinate transformation, normalization, and low-pass filtering in 2D Fourier spectrum to raw CT-images. The applicability and performance of the techniques are showcased by describing extraction of 3D pore structures from micro-CT images of porous basalt using artifacts reductions, binarization, and volume stacking. Comparisions between calibrated and raw images indicate that the artifacts removal allows us to avoid the overestimation of porosity of imaged materials, and proper calibration of the artifacts plays a crucial role in using X-ray CT for geomaterials.

The Periodic Moving Average Filter for Removing Motion Artifacts from PPG Signals

  • Lee, Han-Wook;Lee, Ju-Won;Jung, Won-Geun;Lee, Gun-Ki
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.6
    • /
    • pp.701-706
    • /
    • 2007
  • The measurement accuracy for heart rate or $SpO_2$ using photoplethysmography (PPG) is influenced by how well the noise from motion artifacts and other sources can be removed. Eliminating the motion artifacts is particularly difficult since its frequency band overlaps that of the basic PPG signal. Therefore, we propose the Periodic Moving Average Filter (PMAF) to remove motion artifacts. The PMAF is based on the quasi-periodicity of the PPG signals. After segmenting the PPG signal on periodic boundaries, we average the $m^{th}$ samples of each period. As a result, we remove the motion artifacts well without the deterioration of the characteristic point.

A Study on Measurement of Capacitive Electrode Motion Artifact (용량성 전극의 동잡음 측정 장치 연구)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.137-141
    • /
    • 2017
  • The indirect-contact bio-electric measurements using capacitive electrodes show large motion artifacts in comparison with conventional direct-contact measurements. It is necessary to measure the motion artifacts quantitatively, for the researches of reducing the motion artifacts. In this study, a device for quantitative measurement of motion artifacts was built. Using the device, an electrode was rubbed against some cloth(cotton) and the voltage variation of the electrode was measured as motion artifact in several environmental conditions(temperature and relative humidity). The measured waveforms agreed with that expected by the triboelectricity and the prior observations of the motion artifacts. Therefore, the results demonstrated the usability of the measurement system built in this study. The measurement system will be a great contribution to future research for reducing motion artifact.

Design of Filter to Reject Motion Artifacts of PPG Signal by Using Two Photosensors

  • Lee, Ju-Won;Nam, Jae-Hyun
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.1
    • /
    • pp.91-95
    • /
    • 2012
  • The photoplethysmography (PPG) signal measured from a mobile healthcare device contains various motion artifacts occurring from a patient’s movements. Recently, to reject the motion artifacts, the method of using an acceleration sensor was suggested, but such sensors are very expensive. Therefore, this study deals with a novel sensor device to replace the acceleration sensor, and evaluated the performance of the proposed sensor experimentally. In the results of the experiments, it is shown that the proposed sensor device can reconstruct the PPG signal despite the occurrence of motion artifacts, and also that the variation rate in heart rate analysis was 1.22%. According to the experimental results, the proposed method can be applied to design a low-cost device.