• 제목/요약/키워드: Array Probe

검색결과 218건 처리시간 0.024초

아연결핍된 단핵구 U937 Cell Line에 있어서의 유전자 발현 탐색 : cDNA Microarray 기법 이용 (Gene Expression in Zn-deficient U937 Cell Line : Using cDNA Microarray)

  • Beattie, John H.;Trayhurn, Paul
    • Journal of Nutrition and Health
    • /
    • 제35권10호
    • /
    • pp.1053-1059
    • /
    • 2002
  • In post-genome period, the technique for identifying gene expression has been changed to high throughput screening. In the field of molecular nutrition, the need for this technique to clarify molecular function of the specific nutrient is essential. In this study, we have tested the zinc-regulated gene expression in zinc-deficient U937 cells, using cDNA microarray which is the cutting-edge technique to screen large numbers of gene expression simultaneously. The study result can be used for the preliminary gene screening data for clarifying, using monocyte U937 cell line, molecular Zn aspect in atherosclerosis. U937 cells were cultured in Zn-adequate (control, 12 $\mu$M Zn) or Zn-deficient (experimental, 0 $\mu$M Zn) ESMI media during 2 days, respectively. Cells were harvested and RNA was extracted. Total RNA was reverse-transcriptinized and synthesized cDNA probe labeled with Cy-3. fluorescent labeled cDNA probe was applied to microarray slide for hybridization slide, and after then, the slide was scanned using fluorescence scanner. ‘Highly expressed genes’ in Zn-deficient U937 cells, comparing to Zn-adequate group, are mainly about the genes for motility protein, immune system protein, oncogene and tumor suppressor and ‘Less highly expressed genes’ are about the genes for transcription, apoptosis associated protein, cell cycle, and several basic transcription factors. The results of this preliminary study imply the effectiveness of cDNA microarray for expression profiling of a singly nutrient deficiency, specially Zn. Furthur study, using tailored-cDNA array and capillary endothelial cell lines, would be beneficial to clarify molecular Zn function, more in detail.

유방암 진단용 광음향 영상 시스템 개발 (Development of Photoacoustic System for Breast Cancer Detection)

  • 이순혁;지윤서;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제24권3호
    • /
    • pp.183-190
    • /
    • 2013
  • 광 음향 영상 장치는 최근 들어 연구와 개발이 활발히 진행 중이며 암을 조기 진단할 수 있는 장치로서의 가능성을 보이고 있다. 본 연구에서는 유방암 조기 진단을 위하여 광 음향 단층촬영 방식의 영상 장치를 개발하고 팬텀을 이용하여 그 유용성을 평가하고자 한다. 튜브 팬텀과 닭 가슴살 팬텀을 제작하고 이동 평균 필터와 3~6 MHz의 대역폭을 갖는 대역 통과 여파기를 설계하여 잡음을 제거하고 시간 지연 빔 형성(delay-and-sum beamforming) 알고리즘을 이용하여 광음향 영상을 재구성 하였다. 연구 결과 영상의 재구성에 있어서 빔 형성 알고리즘을 적용하기 전에 대역 통과 여파기와 같은 신호 처리가 효과적임을 보였다.

삼차원 좌표 측정을 위한 부피 간섭계의 오차분석 및 성능평가 (Error analysis and performance test of the volumetric interferometer for three dimensional coordinate measurements)

  • 이혁교;주지영;김승우
    • 한국광학회지
    • /
    • 제13권6호
    • /
    • pp.521-529
    • /
    • 2002
  • 본 연구에서는 삼차원 공간상에서 절대 좌표를 측정하기 위한 부피 간섭계의 오차원인을 분석하고 각 오차원인이 최종 결과에 미치는 영향을 계산했다. 계산결과 광검출기 배열의 비선형성, 압전소자의 비선형성, 광섬유 내부의 온도변화 둥이 오차의 주요 원인임을 알 수 있다. 제안된 간섭계의 성능을 실험적으로 검증하기 위해 분해능 측정 및 이차원 광학식 스케일과의 비교를 수행했다. 또한 간섭계의 성능을 좀 더 엄밀하게 검증하기 위해 자가보정법을 적용해서 공간상에서 간섭계가 갖는 계통오차를 추출했으며 60mm$\times$60mm$\times$20mm공간에서 최대오차 1 $\mu\textrm{m}$ 이하를 얻었다.

THE PROCESSING OF CLUMPY MOLECULAR GAS AND STAR FORMATION IN THE GALACTIC CENTER

  • LIU, HAUYU BAOBAB;MINH, YOUNG CHOL;MILLS, ELISABETH
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.133-137
    • /
    • 2015
  • The Galactic center uniquely provides opportunities to resolve how star clusters form in neutral gas overdensities engulfed in a large-scale accretion flow. We have performed sensitive Green Bank 100m Telescope (GBT), Karl G. Jansky Very Large Array (JVLA), and Submillimeter Array (SMA) mapping observations of molecular gas and thermal dust emission surrounding the Galaxy's supermassive black hole (SMBH) Sgr $A^{\ast}$. We resolved several molecular gas streams orbiting the center on ${\gtrsim}10$ pc scales. Some of these gas streams appear connected to the well-known 2-4 pc scale molecular circumnuclear disk (CND). The CND may be the tidally trapped inner part of the large-scale accretion flow, which incorporates inflow via exterior gas filaments/arms, and ultimately feeds gas toward Sgr $A^{\ast}$. Our high resolution GBT+JVLA $NH_3$ images and SMA+JCMT 0.86 mm dust continuum image consistently reveal abundant dense molecular clumps in this region. These gas clumps are characterized by ${\gtrsim}100$ times higher virial masses than the derived molecular gas masses based on 0.86 mm dust continuum emission. In addition, Class I $CH_3OH$ masers and some $H_2O$ masers are observed to be well associated with the dense clumps. We propose that the resolved gas clumps may be pressurized gas reservoirs for feeding the formation of 1-10 solar-mass stars. These sources may be the most promising candidates for ALMA to probe the process of high-mass star-formation in the Galactic center.

전립선암의 온열치료를 위한 초음파변환기 개발에 관한 연구 (A study for implementation of ultrasonic transducer in the prostate cancer hyperthermia)

  • 박문규;노시철;박재현;최흥호
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.377-384
    • /
    • 2009
  • The ultrasonic hyperthermia for oncology has been developed and studied. The HIFU(high intensity focused ultrasound) is the most recent method to treat the tumor by using ultrasound. In this study, an insertion-type transducer for treating a prostate cancer, which can focus the ultrasonic beam mechanically and electrically, was designed and developed. The developed transducer was composed of three arrays, and each array has 32 elements. For the purpose of the mechanical focusing, both side arrays are slanted to the center array by $15^{\circ}$. With this structure, NFL(near field length) was set up as 30 mm. The PZT-4 and two matching layers were used, and the backing layer was excepted to prevent energy losses. The acoustic field analysis and the heating test were performed to evaluate the performance of developed transducer. The shape of an acoustic field, peak pressure, and acoustic pressure distribution were compared with numerical simulation. The NFL was 32 mm, the beam width was 5 mm, focal area was $40\;mm^2$, and peak pressure was 5.5 MPa. With heating by using developed transducer, the temperature increased up to $33^{\circ}C$ at focal zone. As a result of this study, the usefulness of suggested transducer for prostate cancer hyperthermia was confirmed by the acoustic field analysis and the heating test with TMM(tissue mimicking) phantom.

신경정신 의학분야의 방사성동위원소 표지 cDNA 마이크로어레이 (Radioactive cDNA microarray in Neurospsychiatry)

  • 최재걸;신경호;이민수;김명곤
    • 대한핵의학회지
    • /
    • 제37권1호
    • /
    • pp.43-52
    • /
    • 2003
  • Microarray technology allows the simultaneous analysis of gene expression patterns of thousands of genes, in a systematic fashion, under a similar set of experimental conditions, thus making the data highly comparable. In some cases arrays are used simply as a primary screen loading to downstream molecular characterization of individual gene candidates. In other cases, the goal of expression profiling is to begin to identify complex regulatory networks underlying developmental processes and disease states. Microarrays were originally used with ceil lines or other simple model systems. More recently, microarrays have been used in the analysis of more complex biological tissues including neural systems and the brain. The application of cDNA arrays in neuropsychiatry has lagged behind other fields for a number of reasons. These include a requirement for a large amount of input probe RNA In fluorescent-glass based array systems and the cellular complexity introduced by multicellular brain and neural tissues. An additional factor that impacts the general use of microarrays in neuropsychiatry is the lack of availability of sequenced clone sets from model systems. While human cDNA clones have been widely available, high qualify rat, mouse, and drosophilae, among others are just becoming widely available. A final factor in the application of cDNA microarrays in neuropsychiatry is cost of commercial arrays. As academic microarray facilitates become more commonplace custom made arrays will become more widely available at a lower cost allowing more widespread applications. in summary, microarray technology is rapidly having an impact on many areas of biomedical research. Radioisotope-nylon based microarrays offer alternatives that may in some cases be more sensitive, flexible, inexpensive, and universal as compared to other array formats, such as fluorescent-glass arrays. In some situations of limited RNA or exotic species, radioactive membrane microarrays may be the most practical experimental approach in studying psychiatric and neurodegenerative disorders, and other complex questions in the brain.

PAUT-based defect detection method for submarine pressure hulls

  • Jung, Min-jae;Park, Byeong-cheol;Bae, Jeong-hoon;Shin, Sung-chul
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권2호
    • /
    • pp.153-169
    • /
    • 2018
  • A submarine has a pressure hull that can withstand high hydraulic pressure and therefore, requires the use of highly advanced shipbuilding technology. When producing a pressure hull, periodic inspection, repair, and maintenance are conducted to maintain its soundness. Of the maintenance methods, Non-Destructive Testing (NDT) is the most effective, because it does not damage the target but sustains its original form and function while inspecting internal and external defects. The NDT process to detect defects in the welded parts of the submarine is applied through Magnetic particle Testing (MT) to detect surface defects and Ultrasonic Testing (UT) and Radiography Testing (RT) to detect internal defects. In comparison with RT, UT encounters difficulties in distinguishing the types of defects, can yield different results depending on the skills of the inspector, and stores no inspection record. At the same time, the use of RT gives rise to issues related to worker safety due to radiation exposure. RT is also difficult to apply from the perspectives of the manufacturing of the submarine and economic feasibility. Therefore, in this study, the Phased Array Ultrasonic Testing (PAUT) method was applied to propose an inspection method that can address the above disadvantages by designing a probe to enhance the precision of detection of hull defects and the reliability of calculations of defect size.

Trans-Cinnamaldehyde가 Lipopolysaccharide로 처리된 BV-2 cell에 미치는 항염증 기전 연구: Microarray 분석 (The Effect of Trans-cinnamaldehyde on the Gene Expression of Lipopolysaccharide-stimulated BV-2 Cells Using Microarray Analysis)

  • 선영재;최영곤;정미영;황세희;이제현;조정희;임사비나
    • 대한한의학회지
    • /
    • 제30권4호
    • /
    • pp.13-27
    • /
    • 2009
  • Objectives: Trans-cinnamaldehyde (TCA) is the main component of Cinnamomi Ramulus and it has been reported that TCA inhibits inflammatory responses in various cell types. Inflammation-mediated neurological disorders induce the activation of macrophages such as microglia in brain, and these activated macrophages release various inflammation-related molecules, which can be neurotoxic if overproduced. In this study, we evaluated gene expression profiles using gene chip microarrays in lipopolysaccharide (LPS)-stimulated BV-2 cells to investigate the antiinflammatory effect of TCA on inflammatory responses in brain microglia. Methods: A negative control group was cultured in normal medium and a positive control group was stimulated with $1{\mu}g/ml$ in the absence of TCA. TCA group was pretreated with $10{\mu}g/ml$ before $1{\mu}g/ml$ LPS stimulation. The oligonucleotide microarray analysis was performed to obtain the expression profiles of 28,853 genes using gene chip mouse gene 1.0 ST array in this study. Results: In positive control group, 1522 probe sets were up-regulated in the condition of the cutoff value of 1.5-fold change and 341 genes with Unigene ID were retrieved. In TCA group, 590 probe sets were down-regulated from among 1522 probe sets and 33 genes with Unigene ID were retrieved, which included 6 inflammation-related genes. We found out that Id3 gene is associated with transforming growth factor-${\beta}$ (TGF-${\beta}$) signaling pathway and Klra8 gene is related to natural killer cell-mediated cytotoxicity pathway. Conclusions: The results mean that TCA inhibits inflammatory responses through down-regulating the expressions of inflammation-related genes in LPS-stimulated BV-2 cells.

  • PDF

Deducing Isoform Abundance from Exon Junction Microarray

  • Kim Po-Ra;Oh S.-June;Lee Sang-Hyuk
    • Genomics & Informatics
    • /
    • 제4권1호
    • /
    • pp.33-39
    • /
    • 2006
  • Alternative splicing (AS) is an important mechanism of producing transcriptome diversity and microarray techniques are being used increasingly to monitor the splice variants. There exist three types of microarrays interrogating AS events-junction, exon, and tiling arrays. Junction probes have the advantage of monitoring the splice site directly. Johnson et al., performed a genome-wide survey of human alternative pre-mRNA splicing with exon junction microarrays (Science 302:2141-2144, 2003), which monitored splicing at every known exon-exon junctions for more than 10,000 multi-exon human genes in 52 tissues and cell lines. Here, we describe an algorithm to deduce the relative concentration of isoforms from the junction array data. Non-negative Matrix Factorization (NMF) is applied to obtain the transcript structure inferred from the expression data. Then we choose the transcript models consistent with the ECgene model of alternative splicing which is based on mRNA and EST alignment. The probe-transcript matrix is constructed using the NMF-consistent ECgene transcripts, and the isoform abundance is deduced from the non-negative least squares (NNLS) fitting of experimental data. Our method can be easily extended to other types of microarrays with exon or junction probes.

Silicon Nitride Cantilever Arrays Integrated with Si Heater and Piezoelectric Sensors for SPM Data Storage Applications

  • Nam, Hyo-Jin;Jang, Seong-Soo;Kim, Young-Sik;Lee, Caroline-Sunyong;Jin, Won-Hyeog;Cho, Il-Joo;Bu, Jong-Uk
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제5권1호
    • /
    • pp.24-29
    • /
    • 2005
  • Silicon nitride cantilevers integrated with silicon heaters and piezoelectric sensors were developed for the scanning probe microscope (SPM) based data storage application. These nitride cantilevers are expected to have better mechanical stability and uniformity of initial bending than the previously developed silicon cantilevers. Data bits of 40 nm in diameter were recorded on PMMA film and the sensitivity of the piezoelectric sensor was 0.615 fC/nm, meaning that indentations less than 20 nm in depth can be detected. For high speed operation, $128{\times}128$ cantilever array was developed.