• Title/Summary/Keyword: Arrangement number

Search Result 773, Processing Time 0.029 seconds

Consequential Change of Wind Environment in Building Arrangements (건물배치에 따른 풍환경 변화)

  • Lee, Sun-Young;Kim, Sang-Jin
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.117-124
    • /
    • 2012
  • The purpose of this study is to investigate the change of wind environment for different building arrangement. In this study, we analyze outdoor wind environment on different building arrangement that take same floor area ratio using the CFD (Computational Fluid Dynamics) method. We do not consider the effect of temperature. Building arrangements of low density, different hight and a lot of green area will change the effect of wind environment. The eight different arrangements of buildings are studied in this paper. In these calculations, we know the different arrangement of buildings change outdoor wind environments. Especially, reducing the number of building and crossing the different height of buildings have a good kind of wind environment at the same floor ratio. We know that these arrangement of buildings to reduce the heat island phenomena on city plan.

An Algorithm Solving SAT Problem Based on Splitting Rule and Extension Rule

  • Xu, Youjun
    • Journal of Information Processing Systems
    • /
    • v.13 no.5
    • /
    • pp.1149-1157
    • /
    • 2017
  • The satisfiability problem is always a core problem in artificial intelligence (AI). And how to improve the efficiency of algorithms solving the satisfiability problem is widely concerned. Algorithm IER (Improved Extension Rule) is based on extension rule. The number of atoms and the number of clauses affect the efficiency of the algorithm IER. DPLL rules are helpful to reduce these numbers. Then a complete algorithm CIER based on splitting rule and extension rule is proposed in this paper in order to improve the efficiency. At first, the algorithm CIER (Complete Improved Extension Rule) reduces the scale of a clause set with DPLL rules. Then, the clause set is split into a group of small clause sets. In the end, the satisfiability of the clause set is got from these small clause sets'. A strategy MOAMD (maximum occurrences and maximum difference) for the algorithm CIER is given. With this strategy, a better arrangement of atoms could be got. This arrangement could make the number of small clause sets fewer and the scale of these sets smaller. So, the algorithm CIER will be more efficient.

A Study on "New Chronological Book Number" ("새 연대순 도서기호법"에 관한 연구)

  • Kim Sung-Won
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.31 no.2
    • /
    • pp.79-93
    • /
    • 1997
  • The Book number, which used to distinguish an individual book from every other book in the same class for easy arrangement and retrieval, can be classified into accession order book number, alphabetical book number. and chronological book number. Nowdays' incredible developing speed of knowledge change the standard of information value, the newest is the best, and user behavior, to seek the newest first. To deal with these changes, libraries need to classify the newest information into the same place. Hoping this system can be adopted in the korean libraries, I introduce the characteristics and structures of $\ulcorner$New Chronological Book Number$\lrcorner$ which was designed to deal with library's need and examine the features of alphabetical arrangement of it.

  • PDF

A Basic Study for Development of Automatic Arrangement Algorithm of Tower Crane using drawing recognition (도면인식을 이용한 타워크레인 위치선정 자동화 알고리즘 개발 기초연구)

  • Lim, Chaeyeon;Lee, Donghoon;Han, Kyung Bo;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.64-65
    • /
    • 2015
  • As construction projects have increased in size and height recently, lifting accounts for increasingly greater portion and tower cranes are used more frequently. At present, the selection and arrangement of tower crane are depend on the experience of experts. However, since the number of experts is fairly limited and a database for tower cranes regarding lifting capacity, operation properties, rent, etc has not been widely employed, tower cranes are often not effectively selected and arranged which can cause cost overruns and delays in the lifting work. To address such issues, this study attempts to perform a basic study for development of automatic arrangement algorithm of tower crane using drawing recognition. If relevant database is established and the algorithm suggested in this study is refined more systematically, even beginning level engineers will be able to plan tower crane arrangement in a way comparable to experienced experts.

  • PDF

Method of 3D Body Surface Segmentation and 2D Pattern Development Using Triangle Simplification and Triangle Patch Arrangement (Triangle Simplification에 의한 3D 인체형상분할과 삼각조합방법에 의한 2D 패턴구성)

  • Jeong, Yeon-Hee;Hong, Kyung-Hi;Kim, See-Jo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.9_10 s.146
    • /
    • pp.1359-1368
    • /
    • 2005
  • When we develop the tight-fit 2D pattern from the 3D scan data, segmentation of the 3D scan data into several parts is necessary to make a curved surface into a flat plane. In this study, Garland's method of triangle simplification was adopted to reduce the number of data point without distorting the original shape. The Runge-Kutta method was applied to make triangular patch from the 3D surface in a 2D plane. We also explored the detailed arrangement method of small 2D patches to make a tight-fit pattern for a male body. As results, minimum triangle numbers in the simplification process and efficient arrangement methods of many pieces were suggested for the optimal 2D pattern development. Among four arrangement methods, a block method is faster and easier when dealing with the triangle patches of male's upper body. Anchoring neighboring vertices of blocks to make 2D pattern was observed to be a reasonable arrangement method to get even distribution of stress in a 2D plane.

Effects of Bearing Arrangement on the Dynamic Characteristics of High-speed Spindle (베어링 배열방식이 고속 스핀들의 동특성에 미치는 영향)

  • Hong, Seong-Wook;Choi, Chun-Seok;Lee, Chan-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.8
    • /
    • pp.854-863
    • /
    • 2013
  • High-speed spindle systems typically employ angular contact ball bearings, which can resist both axial and radial loading, and exhibit high precision and durability. We investigated the effects of the arrangement of the angular contact ball bearings on the dynamics of high-speed spindle systems. The spindle dynamics were studied with a number of spindle-bearing models, and the location of the bearings was varied, along with the rotational speed and the preload. A finite element spindle model and a bearing model were used, and simulated data showed that the bearing arrangement significantly affected the spindle dynamics. Furthermore, the main effects were due to the cross coupling terms between the transverse and rotational motions of the ball bearings. The coupling stiffness terms were found to influence the spindle dynamics, depending on the mode shapes. An extensive discussion is provided on the effects of the bearing arrangement on the dynamics of the spindle.

An Experimental Study on Heat Transfer Characteristics of Arrangement Chips by Swirl Jet Impingement (선회충돌제트에 의한 배열 칩의 열전달 특성에 관한 실험적 연구)

  • 최재욱;전영우;정인기;박시우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.624-631
    • /
    • 2004
  • The experimental study on heat transfer characteristics of protruding heated block array as conducted to investigate and to compare the performance of impinging single circular jet in fully developed tube with a twisted tape as a swirl generator. The effects of jet Reynolds number(Re=8700, 13800, 20000. 26500), dimensionless jet-to-block distance(H/d=1. 3, 5. 7) and swirl number(S=0.11, 0.23, 0.30) of the swirl jet on the average Nusselt number for each block and all blocks have been examined. Measurements of heat transfer rate on block surfaces were used naphthalene sublimation technique. Mean velocity and turbulence intensity of the jet along the axis were measured. Potential core length of the jet was 5 times of nozzle diameter because it was fully developed and initially turbulent. With the twisted tape in the nozzle, heat transfer coefficients were higher than those without the twisted tape. which are mainly caused with increasing the jet Reynolds number and swirl number.

The Development of Leaves in Amaranthus retroflexus and Chenopodium album Represented by the Plastochron(I. The Derivation of the Plastochron Index) (Plastochron 에 의한 Amaranthus retroflexus 와 Chenopodium album 의 잎의 성장 해석 1. Plastochron Index 의 유도)

  • Park, Bong-Kyu;Joung-Hee Kim
    • The Korean Journal of Ecology
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 1985
  • The plastochron index (PI) provides possibility on studies of the effects of various environmental factors on morphological and physiological development of plants. The PI of Erickson and Michemlini(1957) could be used merely when leaf n is longer an leaf n+1 is smaller than the references length at any time. If both the lengths of leaf n and n+1 are smaller or longer than the reference length, it could not estimated. In this study, the PI of Erickson and Michelini was complemented and the linear patterns according to leaf arrangement was represented, PI is n-(lnLR-lnLn)/(lnLn-lnLn+1). And when both the lengths of leaf n and n+1 are longer than the length of reference, PI is n+1+(ln Ln+1-lnLR)/(lnLn-lnLn+1). The linear model of PI is changed by the various environmental factors and the linear patterns are different according to leaf arrangement. According to leaf arrangement, the equation of the general regression lines is Yin-(i-j)=a-(n-1)(q1+...+qi-1)-(q1+...+qj-1)+rt+$\varepsilon$. Where Y:the logarithmic of the leaf length in question, i:leaf number hang on the one node, n:the number counting from base, q:spacing on the Y-axis, j:0, 1, 2, ..., r:slope, t:time, $\varepsilon$:error.

  • PDF

Characteristics of Flow over a Pair of Circular Cylinders in a Side-by-Side Arrangement (나란히 배열된 한 쌍의 원형실린더를 지나는 유동 특성)

  • Kang, Sang-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.909-919
    • /
    • 2003
  • Two-dimensional flow over a pair of circular cylinders in a side-by-side arrangement at low Reynolds numbers has been numerically investigated in this study Numerical simulations are performed, using the immersed boundary method, for the ranges of 40$\leq$Re$\leq$160 and $g^{*}$<5, where Re and $g^{*}$ are, respectively, the Reynolds number and the spacing between the two cylinder surfaces divided by the cylinder diameter. Results show that a total of six kinds of wake patterns are observed over the ranges: antiphase-synchronized, inphase-synchronized, flip-flopping, single bluff-body, deflected, and steady wake patterns. It is found that the characteristics of the flow significantly depends both on the Reynolds number and gap spacing, with the latter much stronger than the former. Instantaneous flow fields, time traces, flow statistics and so on are presented to identify the wake patterns and then to understand the underlying mechanism. Moreover, the bifurcation phenomenon where either of two wake patterns can occur is found at certain flow conditions.ons.

Effects of Thermoelectric Module Arrangement on the Performance of a Thermoelectric Air-Cooling System (열전모듈 냉방기에서 열전모듈의 개수 및 전원배열이 시스템의 성능에 미치는 영향)

  • Hwang, Jun;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.162-168
    • /
    • 2007
  • This paper presents the effects of thermoelectric module arrangement on the cooling performance of an air conditioner using thermoelectric module. A prototype of air cooling system, employing several thermoelectric modules, has been designed and built. The evaporative cooling technique is adopted for hot side of the module. The number of thermoelectric module in the system has been varied in the range of $2{\sim}8$. The optimal operation conditions, such as input power to the thermoelectric module, fans and pump, have been determined for each arrangement of the system and the cooling performance has been compared under the optimal operation. It is found that both cooling capacity and COP are increased as the number of thermoelectric module increased. It is also found that cooling capacity can be improved by connecting the thermoelectric modules in series than in parallel, while the COP is little affected.