• 제목/요약/키워드: Arc test

검색결과 715건 처리시간 0.031초

음향방출법에 의한 SM490A강의 복합용접성 평가 (1) (The Evaluation of Mixed-welded SM 490A Steel by Acoustic Emission (1))

  • 이장규;우창기;박성완;김봉각;윤종희;인승현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.170-173
    • /
    • 2002
  • The object of this study is to investigate the effect of compounded welding through the AE (Acoustic Emission) characteristics on static tensile test. This study was carried out a SM 490A, high tension steel using the low hydrogen type E4316 of electronic shield metal arc welding and compound wire of $CO_2$gas arc welding. $CO_2$welding, weak in the intensity of HAZ (Heat Affected Zone), can be improved by being combined with coated arc welding, Coated arc welding, weak in the intensity of the bead, can be improved by being combined with $CO_2$welding. Especially, electronic coated arc welding and $CO_2$welding complement the mechanical intensity of HAZ and the bead with each other. So, compounded welding increases the intensity in the special parts and enhances the quality of goods.

  • PDF

EMTP를 이용한 아크 사고의 모의 (Simulation of Fault-Arc using EMTP)

  • 변성현;최해술;채종병;김철환;한경남;김일동;김영한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.850-852
    • /
    • 1996
  • High impedance fault (HIF) is defined as fault that general overcurrent relay can't detect or interrupt, Especially when HIF occur under 15 kV, energized high voltage conductor results in fire hazard, equipment damage or personal threat. Because most HIF occur arc, HIF detection using arc is to increase. Numerical arc model can be applied in an electromagnetic transients program (EMTP) to reproduce the dynamic and random characteristic of arcs for any insulator arrangement, current and system voltage. It allows the representation of any network configuration to be investigated, so the digital simulation of arc faults through air can be substitute for demanding power arc test.

  • PDF

순티타늄의 교류 불꽃 양극산화층 미세조직에 미치는 양극산화공정변수 및 대기산화온도의 영향 (The Effects of Anodizing Process Parameters and Oxidation Temperature under Atmospheric Environment on Morphology of the Pure Titanium by Alternating Current Arc-anodizing)

  • 양학희;박종성
    • 한국표면공학회지
    • /
    • 제41권1호
    • /
    • pp.16-22
    • /
    • 2008
  • Anodizing to form oxide layers on the pure titanium was performed in the electrolyte containing 1.5M $H_2SO_4$, 0.2M $H_3PO_4$, and 2.5wt.% $CuSO_4$ using the ac-biased arc anodizing technique. Titanium oxide layers anodized with different applied voltages, voltage-elevating rates, and anodizing times were investigated. In addition, thermal oxidation test under an atmospheric environment for the arc-anodized specimens was carried out. The thickness of oxide layers were not affected by the voltage-elevating rates, but increased slightly with the increase of anodizing times. The thickness of oxide layers were increased with the increase of voltages, and increased remarkably in the condition of 200V. The size and number of the pore observed in the center of the porous cell were decreased with increase of applied voltage. From the result of thermal oxidation test, it revealed that oxide layer formed by arc anodizing more effective to prevent oxidation of pure titanium.

절연체의 내아크성 평가를 위한 안테나 기법의 적용에 관한 연구 (Study on the application of antenna method for the criterion test of insulator arc resistance)

  • 이강원;김명룡;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.57-60
    • /
    • 2004
  • Electrical arc is the final stage of insulation breakdown and has high current density which cause heat and light in insulator. Insulator under electrical arc lost its insulating strength and eternal damages. Conventional criterion of electrical arc resistance in Standards have depended on the change of sound pressure and light color after damages on insulator by electrical arc. The recognition of these changes is done by human himself which was very subjective and resulted in some error to judge whether insulator has damages or not. This paper has shown that antenna method is the appropriate measure to judge electrical arc resistance for insulator. Antenna measures the electromagnetic waves radiated from tungsten electrodes with 6mm gap regulated by KSC2130. Applied voltage cross two tungsten electrodes have two different methods such as 1/8 10 and continuous 10mA. Signal amplitudes obtained by antenna has diminished after the damage of insulator, which will provide objective and good way to judge the electrical arc resistance.

  • PDF

TIG클래딩 공정에 대한 품질 모니터링기법의 개발 (Development of Welding Quality Monitoring Method for TIG Cladding)

  • 조상명;박정현;손민수
    • Journal of Welding and Joining
    • /
    • 제31권6호
    • /
    • pp.90-95
    • /
    • 2013
  • Pipe inside clad welding is mainly used to the flow pipe of sub-sea or chemical plant. For the inside clad welding to the medium pipe with the diameter of about 12", TIG welding is frequently applied with filler metal. In this case, the clad welding has the very broad weld area over $10m^2$. And, the non-destructive test (NDT) such as ultrasonic test (UT) or radiographic testing (RT) should be conducted on the broad weld area, and it costs very high due to the time-consuming work. Therefore, the present study investigated the variation of arc voltage to develop the in-line quality monitoring system for the pipe inside TIG cladding. The 4 experimental parameters (current, arc length, wire feed position, and shield gas flow rate) varied to observe the change of arc voltage and to establish the model for the monitoring. The arc voltage was decreased when the wire was fed to the backward eccentric position(over 2mm), and the shield gas flow rate was insufficient under 10L/min. In the case of the backward eccentric position over 2mm, the bead appearance was not good and the dilution ratio was increased due to deep penetration. When the shield gas flow rate was lower than 10L/min, the bead surface was oxidized.

$CO_2$아크 스폿 용접법에 의한 조립보의 굽힘강도에 관한 연구 (A Study on the Bending Strength of a Built-up Beam Fabricated by the $CO_2$ Arc Spot Welding Method)

  • 한명수;한종만;이준열
    • Journal of Welding and Joining
    • /
    • 제15권4호
    • /
    • pp.143-153
    • /
    • 1997
  • In this study, bending test was performed on the real-scale, built-up beam test model fabricated by the $CO_2$ arc spot welding to evaluate the applicability of the welding method to the production of the stiffened plate in car-carrying ship. The built-up beam models which were fixed at both ends in longitudinal direction or simply supported to the rigid foundation, depending on the restraint condition of the corresponding car decks considered, were subjected to simulated design vehicle loads or concentrated point loads. During the test, the central deflection and the longitudinal bending stresses were measured from several points on the longitudinal flange face to predict the section properties of the built-up beams. The longitudinal bending stress on each spot weld were also measured to calculate the average horizontal shear force subjected to spot welds. Test results revealed that the shear strength of spot welds with their current weld nugget size and welding pitch was adequate enough to withstand the horizontal shear forces under the design vehicle loads. Although the built-up beam fabricated by the arc spot welding was a discontinuous beam, its mechanical behavior was well explained by the continuous beam theory using the effective breadth of plate. Based on test results, the criterion for the size of spot weld of which the average shear stress might meet the allowable stress requirement of AWS Code could be established.

  • PDF

Analysis of Arc Tube Properties by Degradation in Ceramic Metal Halide Lamp

  • Yang, Jong-Kyung;Jang, Hyeok-Jin;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.123-127
    • /
    • 2011
  • To clarify the relations of optical properties to the main factors responsible for the loss and damage of luminous efficacy, a 20 min turn-on/turn-off test for 2,000 h for a ceramic metal halide lamp is conducted. The corrosion rates of the arc tube wall and electrode are estimated based on thermal stress. Wall blackening is attributed to the tungsten being transported from the hot electrode tips to the relatively cold arc tube wall. Furthermore, the grain boundaries of the arc tube are changed by the degradation. Distortion of the electrode is observed, and the ignition and the driving voltage of the load both increase. Finally, the color rendering index and the color coordinates are changed after the degradation. The luminous flux and the intensity of the luminous distribution are decreased significantly.

직렬아크 방전의 주파수 스펙스럼 분석

  • 김선재;정광석;박대원;길경석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.24-24
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of electromagnetic waves which is generated by series arc discharges to develop a condition monitoring technique in a closed-distribution board. We fabricated an arc generator specified in UL1699 to simulate series arc discharge. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of a Ultra Log Antenna and a EMI Test Receiver. The results showed that the frequency spectrum during series arc discharges was distributed in ranges of 30~500 [MHz], and the peak values were existed at 40 [Mhz] and 80 [MHz].

  • PDF

방사전자파의 주파수분석에 의한 배전반 진단기술 (Diagnostic Technique of a Switchboard by Frequency Analysis of Radiated Electromagnetic Wave)

  • 박대원;김선재;정광석;길경석;조은제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.41-45
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic waves generated by series arc- and corona- discharges as a basic study to develop an online diagnostic technique for power facilities installed inside switchboards. To simulate corona and series arc discharges, an arc generator specified in UL1699 and a corona generator were fabricated. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an Ultra Log Antenna and an EMI Test Receiver. The frequency spectrum exists in ranges from 30 to 500 [MHz] for series arc discharge and 30 [MHz] to 2 [GHz] depending on defects for corona discharge. The peak frequency of series arc discharge and corona were 40 [MHz], 80 [MHz] and 35 [MHz]~160 [MHz], respectively.

  • PDF

Analysis of the Fume Generation Rates in the Flux Cored Arc welding

  • Chae, H.B.;Kim, J.H.;Yang, S.C.
    • International Journal of Korean Welding Society
    • /
    • 제1권1호
    • /
    • pp.71-77
    • /
    • 2001
  • The characteristics of the fume generation in a flux cored arc welding were investigated using the fume collection chamber developed. The Korean Standard concerning the method for the evaluation of the fume generation rate(FGR) was updated by the evaluation method obtained through this study. It was found that the effect of humidity in the test environment should be considered and the automatic welding method had to be employed for the purpose of the exact evaluation of the fume generation rate. The results showed that the fume generation rate was influenced by the welding parameters. The important factors were the welding current arc voltage, travel speed, and contact tip to work distance(CTWD) that affected the heat input as well as the torch angle and the shielding gas flow rate that influenced the shielding effect. The fume generation rate increased as the heat input increased and the shielding effect decreased. It was also observed that the effect of the welding current is much grater than the other welding parameters.

  • PDF